Search PubMed⌕ Search

Biomedical subjects

J W Moses

Publications and source records attributed to J W Moses.

At least 37 records · Page 2Linked to original sources

Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study.

BACKGROUND: Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone. METHODS AND RESULTS: The CRUISE (Can Routine Ultrasound Influence Stent Expansion) study, a multicenter study IVUS substudy of the Stent Anti-thrombotic Regimen Study, was designed to assess the impact of IVUS on stent deployment in the high-pressure era. Nine centers were prospectively assigned to stent deployment with the use of ultrasound guidance and 7 centers to angiographic guidance alone with documentary (blinded) IVUS at the conclusion of the procedure. A total of 525 patients were enrolled with completed quantitative coronary angiography, quantitative coronary ultrasound, and clinical events adjudicated at 9 months for 499 patients. The IVUS-guided group had a larger minimal lumen diameter (2.9+/-0.4 versus 2.7+/-0. 5 mm, P<0.001) by quantitative coronary angiography and a larger minimal stent area (7.78+/-1.72 versus 7.06+/-2.13 mm(2), P<0.001) by quantitative coronary ultrasound. Target vessel revascularization, defined as clinically driven repeat interventional or surgical therapy of the index vessel at 9 month-follow-up, occurred significantly less frequently in the IVUS-guided group (8.5% versus 15.3%, P<0.05; relative reduction of 44%). CONCLUSIONS: These data suggest that ultrasound guidance of stent implantation may result in more effective stent expansion compared with angiographic guidance alone.

Aspirin↗

Procedural costs of digital vs. analog archiving of diagnostic cardiac catheterizations.

The use of digital technology in the cardiac catheterization laboratory is expanding at a rapid pace. The cost-effectiveness of this new technology is yet to be proven. The aims of this study were to determine the direct cost differences of digital versus analog media (CDs) for the storage of diagnostic cardiac catheterizations and to explore the factors influencing these differences. Procedural costs of all diagnostic angiograms (n = 109), from three physicians, performed in an analog catheterization laboratory (room A) and a digital catheterization laboratory (room C) were compared during a 9-month period. The mean procedural cost was higher in room A than in room C ($1,102 vs. $1,087, P < 0.001). This cost difference was eliminated when recording media costs were excluded from analysis ($1,079 vs. $1,080, P = 0.931). Therefore, we conclude there is a procedural cost savings in a cardiac catheterization room that uses digital CDs versus cineangiogram film as the archival media. Cathet. Cardiovasc. Intervent. 49:246-250, 2000.

Cardiac Catheterization↗

The skirt technique: A stenting technique to treat a lesion immediately proximal to the bifurcation (pseudobifurcation).

We report a new stenting technique employed in 10 patients to treat lesions immediately proximal to a bifurcation (pseudobifurcation). A stent is mounted on two balloon catheters and advanced into the lesion immediately proximal to the bifurcation until the distal portion of the balloon catheters enters each branch at the bifurcation. This is followed by kissing balloon inflation for stent deployment. In all 10 cases, the final angiogram showed a good result at the lesion site and no ostial compromise of any of the branches. Cathet. Cardiovasc. Intervent. 51:347-351, 2000.

Aged↗

Endoluminal reconstruction of the arterial wall with endothelial cell/glue matrix reduces restenosis in an atherosclerotic rabbit.

OBJECTIVES: The objectives of this study were 1) to improve the attachment of reimplanted endothelial cells (EC) using a fibrin glue, and 2) to assess the impact of endothelial reseeding on restenosis eight weeks after balloon angioplasty. BACKGROUND: A possible mechanism contributing to restenosis after balloon angioplasty is the loss of the EC lining. Previous attempts to reseed EC had little effect due to rapid loss of the seeded cells. METHODS: Twelve atherosclerotic rabbits were subjected to angioplasty of iliac arteries and reseeding procedure. One iliac artery was subjected to EC/glue reconstruction and a contralateral site to EC seeding without glue. The animals were sacrificed after 4 h. In another series 12 rabbits were treated in the same fashion and were restudied at eight weeks. Additionally, in 10 animals one iliac was subjected to glue treatment, and another served as control. RESULTS: Histological examination demonstrated the ability of this method to reattach the EC/glue matrix circumferentially to 68.0 +/- 6.7% of the arterial wall in comparison with 13.5 +/- 3.9% reattachment after EC seeding. Morphometry at eight weeks showed that the lumen area was significantly greater in the EC/glue group (1.23 +/- 0.35 mm2) than in the EC seeding alone (0.65 +/- 0.02 mm2) and 0.72 +/- 0.41 mm2 in the glue group. This was principally accounted for by the statistically significant differences in the intimal area (0.76 +/- 0.18 mm vs. 1.25 +/-0.26 mm2 and 1.01 +/- 0.53 mm2, respectively). CONCLUSIONS: The attachment of EC after angioplasty can be greatly improved with fibrin glue matrix. The near 70% endothelial coverage achieved by this method resulted in a significant reduction of restenosis in atherosclerotic rabbit.

Angioplasty, Balloon↗

Low-power laser irradiation increases cyclic GMP synthesis in penile smooth muscle cells in vitro.

OBJECTIVE: The objective of the present study was to determine the effect of low-power laser irradiation (LPLI) on cyclic guanosine monophosphate (cGMP) produced by human corpus cavernosum smooth muscle cells (HCC SMC) in vitro. BACKGROUND DATA: Numerous reports suggest that LPLI is capable of affecting cellular processes in the absence of significant thermal effect METHODS: HCC SMC cultures were irradiated with single-dose LPLI using a He-Ne continuous wave laser (632 nm) with different energy densities (0.52-2.1 J/cm2). Assessment of effect on cell viability was performed utilizing Alamar Blue assay. Effect of LPLI on cGMP production was studied by radioimmunoassay. RESULTS: We observed that: (1) LPLI of HCC SMC results in a statistically significant increase of cGMP synthesis in culture and is dose dependent (maximal effect was observed with LPLI irradiance of 1.57 J/cm2. (2) There were no changes in Normalized Viability Index (NVI) immediately after and 24 h following laser irradiation. CONCLUSION: Our studies demonstrate that LPLI irradiation stimulates elevation of cGMP in vitro.

Adult↗

Photoactivation of vascular iNOS and elevation of cGMP in vivo: possible mechanism for photovasorelaxation and inhibition of restenosis in an atherosclerotic rabbit models.

Recently, intravascular low-power red laser light (LPRLL) therapy has been proposed for the prevention of postangioplasty restenosis due to the observed inhibition of experimental neointimal formation. The objective of this study was to determine the impact of endoluminal LPRLL on vascular levels of inducible nitric oxide synthase (iNOS) and cyclic guanosine monophosphate (cGMP) to help define the mechanism of this effect. Eight atherosclerotic male adult New Zealand White rabbits weighing 4-6 kg were used in these studies. The iliac arteries were treated in separate zones with: (1) balloon inflation only; (2) laser illumination only; and (3) balloon inflation + laser illumination. An uninjured zone of the iliac artery served as a control. Laser irradiation (630 nm) was delivered to the vessel wall via a Cold laser Illuminator (Cook, Inc., Bloomington, IN), with a 3 mm-diameter balloon. Experiments demonstrated that vascular cGMP levels obtained immediately following treatment in the balloon only group was the lowest (0.29 +/- 0.05 pmol/mg protein) and significantly lower compared with the uninjured controls (1.01 +/- 0.07 pmol/ mg protein) (P < 0.001). In the laser only treated group cGMP levels were significantly increased (2.87 +/- 0.12 pmol/mg protein) compared with the uninjured control (P < 0.001) and the balloon only group (P < 0.001). Vascular cGMP levels in the balloon + laser group (2.09 +/0.07 pmol/mg protein) was also increased compared to the balloon only (P < 0.001) and control (P < 0.001) groups. Qualitative analysis of Western blot demonstrated that laser illumination induces iNOS. In contrast balloon dilatation did not induce iNOS. Balloon + laser treatment, however, tended to restore the expression of iNOS. Our study demonstrated that intravascular low dose laser irradiation induces iNOS and elevates vascular cGMP in an in vivo atherosclerotic rabbit model.

Angioplasty, Balloon↗

Effectiveness of clopidogrel and aspirin versus ticlopidine and aspirin in preventing stent thrombosis after coronary stent implantation.

BACKGROUND: Ticlopidine has been shown to reduce the incidence of stent thrombosis compared with warfarin, but it may cause serious hematological side effects. Clopidogrel, a new thienopyridine derivative, may be a safe alternative to ticlopidine. The aim of this study was to compare the safety and efficacy of clopidogrel and aspirin with those of ticlopidine and aspirin in patients undergoing coronary stent implantation. METHODS AND RESULTS: The population of this study consisted of 2 groups: patients who underwent coronary stenting and were treated with ticlopidine and aspirin (TA group, n=1406), and patients who underwent coronary stenting followed by treatment with clopidogrel and aspirin (CA group, n=283). At 1-month follow-up, there was no difference in stent thrombosis (1.5% versus 1.4%, P=1.0) or major adverse cardiac events (3.1% versus 2.4%, P=0. 85) between the TA and CA groups, respectively. The probability of any side effect (neutropenia, diarrhea, rash) was significantly higher in the TA group (10.6% versus 5.3%, P=0.006; relative risk, 0. 53; CI, 0.32 to 0.86). CONCLUSIONS: These data suggest that clopidogrel may be an effective pharmacological regimen after coronary stent implantation. Furthermore, the simpler dosing regimen, the absence of neutropenia, and the lower frequency of other side effects make it a safe alternative to ticlopidine.

Aged↗

Risk of distal embolization and infarction with transluminal extraction atherectomy in saphenous vein grafts and native coronary arteries. NACI Investigators. New Approaches to Coronary Interventions.

Lower success rates have been reported when treating high-risk lesions in saphenous vein grafts (SVGs) and native coronary arteries with balloon angioplasty. The transluminal extraction atherectomy catheter (TEC) has been proposed to reduce the incidence of distal embolization (DE) in subsets of high-risk lesions. To define the utility of TEC in reducing the incidence of DE, all patients who were enrolled in the New Approaches to Coronary Interventions (NACI) Registry and had TEC planned as the sole treatment were studied (329 patients with 381 lesions). Of the lesions treated, 75.9% were in SVGs; 37.5% were thrombotic; and 15% were total occlusions. Adjunctive percutaneous transluminal coronary angioplasty (PTCA) was performed in 87.4% of lesions. Multivariate predictors of DE were: noncardiac disease, stand alone TEC, thrombus, and larger vessel size. DE was associated with an 18.5% in-hospital mortality vs. 3.0% without DE (P < 0.01) and a 25.9% MI rate vs. 5.0% without DE (P < 0.01). In conclusion, in this high-risk subset of patients, TEC is associated with an 8.3% incidence of DE with thrombotic and SVGs lesions. DE associated with TEC appears to carry high morbidity and mortality. Additional techniques to control DE are needed to reduce the frequency of complications in these patients.

Aged↗

Use of the Shinobi wire in chronic coronary occlusions.

Occlusion angioplasty has represented a challenge since the introduction of the procedure. We report the successful use of a new, stiff, highly torquable, Teflon-coated wire, the Shinobi wire, in nine coronary occlusions and have included the detailed description of three representative cases. In the discussion we have reviewed the current literature on devices used in coronary occlusions. Cathet. Cardiovasc. Intervent. 48:100-104, 1999.

Angioplasty, Balloon, Coronary↗

Outpatient carotid artery stenting: a case report.

PURPOSE: To report a case of carotid artery stenting for asymptomatic carotid restenosis performed in an outpatient setting. METHODS AND RESULTS: A 68-year-old man with right carotid restenosis after repeat carotid endarterectomy underwent carotid angioplasty and stenting on an ambulatory basis. The procedure to implant a Smart stent required 45 minutes; the femoral access site was closed with a puncture closure device. The patient experienced no sequelae to this procedure and is well 6 months after treatment. CONCLUSIONS: Outpatient delivery of percutaneous carotid stenting may be feasible in appropriately selected patients.

Aged↗

Randomized, placebo-controlled trial of platelet glycoprotein IIb/IIIa blockade with primary angioplasty for acute myocardial infarction. ReoPro and Primary PTCA Organization and Randomized Trial (RAPPORT) Investigators.

BACKGROUND: The benefit of catheter-based reperfusion for acute myocardial infarction (MI) is limited by a 5% to 15% incidence of in-hospital major ischemic events, usually caused by infarct artery reocclusion, and a 20% to 40% need for repeat percutaneous or surgical revascularization. Platelets play a key role in the process of early infarct artery reocclusion, but inhibition of aggregation via the glycoprotein IIb/IIIa receptor has not been prospectively evaluated in the setting of acute MI. METHODS AND RESULTS: Patients with acute MI of <12 hours' duration were randomized, on a double-blind basis, to placebo or abciximab if they were deemed candidates for primary PTCA. The primary efficacy end point was death, reinfarction, or any (urgent or elective) target vessel revascularization (TVR) at 6 months by intention-to-treat (ITT) analysis. Other key prespecified end points were early (7 and 30 days) death, reinfarction, or urgent TVR. The baseline clinical and angiographic variables of the 483 (242 placebo and 241 abciximab) patients were balanced. There was no difference in the incidence of the primary 6-month end point (ITT analysis) in the 2 groups (28.1% and 28.2%, P=0.97, of the placebo and abciximab patients, respectively). However, abciximab significantly reduced the incidence of death, reinfarction, or urgent TVR at all time points assessed (9.9% versus 3.3%, P=0.003, at 7 days; 11.2% versus 5.8%, P=0.03, at 30 days; and 17.8% versus 11.6%, P=0.05, at 6 months). Analysis by actual treatment with PTCA and study drug demonstrated a considerable effect of abciximab with respect to death or reinfarction: 4.7% versus 1.4%, P=0.047, at 7 days; 5.8% versus 3.2%, P=0.20, at 30 days; and 12.0% versus 6.9%, P=0.07, at 6 months. The need for unplanned, "bail-out" stenting was reduced by 42% in the abciximab group (20.4% versus 11.9%, P=0.008). Major bleeding occurred significantly more frequently in the abciximab group (16.6% versus 9.5%, P=0.02), mostly at the arterial access site. There was no intracranial hemorrhage in either group. CONCLUSIONS: Aggressive platelet inhibition with abciximab during primary PTCA for acute MI yielded a substantial reduction in the acute (30-day) phase for death, reinfarction, and urgent target vessel revascularization. However, the bleeding rates were excessive, and the 6-month primary end point, which included elective revascularization, was not favorably affected.

Abciximab↗

Relation between single tomographic intravascular ultrasound image parameters and intracoronary Doppler flow velocity in patients with intermediately severe coronary stenoses.

BACKGROUND: Intravascular ultrasound (IVUS) imaging parameters have been suggested as criteria to determine coronary lesion significance before intervention. However, there has not been a systematic examination of combined anatomic and physiologic data in the same patients with coronary artery disease. METHODS AND RESULTS: To examine the relation between coronary flow reserve and IVUS parameters, 41 patients with intermediately severe coronary artery stenoses had measurements of coronary flow velocity (0.014-inch Doppler flow wire), coronary flow velocity reserve (CVR) (hyperemic/basal mean flow), IVUS imaging (2.9F, Cardiovascular Imaging Systems, Inc.), and quantitative coronary angiography before intervention. Correlations between physiologic and anatomic parameters were performed by simple regression. Results were also examined by patient subgroups with CVR > 1.8 or < 1.8 to assess differences in IVUS parameters. The angiographic percent diameter stenosis was 52% +/- 17% (range 18% to 95%). Mean CVR was 1.88 +/- 0.56 (range 0.9 to 3.18). IVUS minimal luminal diameter (r = 0.312, p = 0.047) and angiographic percent stenosis (r = 3.05, p = 0.052) were weakly related to poststenotic CVR. Comparing patients with CVR < 1.8, IVUS reference segment area, IVUS lumen area, and angiographic percent diameter stenosis was higher (17.7 +/- 0.3 vs 12.9 +/- 4.4 mm2, p < 0.05; 6.20 +/- 3.76 vs 4.34 +/- 2.00 mm2, p < 0.05; and 60% +/- 14% vs 46% +/- 17%, p < 0.01, respectively) than in the group with CVR > 1.8. CONCLUSIONS: Despite a precise determination of cross-sectional vessel areas and absolute dimensions by IVUS, single tomographic measurements did not correlate well with coronary physiologic responses. These data suggest that the physiologic data may be complementary to anatomic quantitative IVUS, enhancing information for coronary interventional decision making.

Blood Flow Velocity↗

Influence of gender on in-hospital clinical and angiographic outcomes and on one-year follow-up in the New Approaches to Coronary Intervention (NACI) registry.

Higher complication rates and lower success rates for treatment of women compared with men have been reported in prior studies of coronary angioplasty and in most early reports of outcome with new coronary interventional devices. In multivariate analysis this has been attributed largely to older age and other unfavorable clinical characteristics. These results are reflected in the current guidelines for coronary angioplasty. Women in prior studies have also had different distributions of vessel and lesion characteristics, but the influence of these differences on the outcome of new-device interventions have not been adequately evaluated. This article evaluates the influence of gender on clinical and angiographic characteristics, interventional procedure and complications, angiographic success, and clinical outcomes at hospital discharge and 1-year follow-up, as observed in the New Approaches to Coronary Intervention (NACI) registry. The NACI registry methodology has been reported in detail elsewhere in this supplement. This study focuses on the 90% of patients-975 women and 1,880 men-who had planned procedures with a single new device and also had angiographic core laboratory readings. Women compared with men were older, had more recent onset of coronary ischemic pain that was more severe and unstable, and had more frequent histories of other adverse clinical conditions. The distributions of several but not all angiographic characteristics before intervention were considered more favorable to angioplasty outcome in women. Differences were observed in device use and procedure staging. Angiographically determined average gain in lumen diameter after new-device intervention, with or without balloon angioplasty, was significantly less in women (1.38 mm) than in men (1.53 mm; p < 0.001); this 0.15 mm difference is consistent with the 0.16-mm smaller reference vessel lumen diameter of women. However, final percent diameter stenoses and TIMI flow and lesion compliance characteristics were similar. Among procedural complications, only treatment for hypotension, blood transfusion, and vascular repair occurred more often in women. More women than men were clinically unstable (2.1% vs 1.1%) or went directly to emergent coronary artery bypass graft surgery (CABG; 1.2% vs 0.6%) on leaving the interventional laboratory. However, in-hospital death (1.4% vs 1.1%), Q-wave myocardial infarction (MI) (0.9% vs 1.1%), and emergent CABG (1.5% vs 1.0%, for women and men, respectively) were not significantly different. Nonemergent CABG was more frequent in women (1.8% vs 0.9%; p < 0.05) and length of hospital stay after device intervention was longer (4.4 days vs 3.8 days in men; p < 0.01). In both univariate and multivariate analyses gender did not emerge as a significant variable in relation to the combined endpoint, death, Q-wave MI, or emergent CABG at hospital discharge. At 1-year follow-up more women than men reported improvement in angina (70% vs 62%) and fewer women than men had had repeat revascularization (32% vs 36%). Similar proportions were alive and free of angina, Q-wave MI and repeat revascularization (46% of women vs 45% of men). Although several procedure-related complications were more frequent in women than men after coronary interventions with new devices, no important disadvantages were observed for women in the rates of major clinical events at hospital discharge and at 1-year clinical follow-up. Additional studies are needed to evaluate the complex interplay of clinical, vessel, and lesion characteristics on success and complications of specific interventional techniques and to determine whether gender, per se, is a risk factor and whether gender specific interventional strategies may be beneficial.

Aged↗

High-speed rotational atherectomy of human coronary stenoses: acute and one-year outcomes from the New Approaches to Coronary Intervention (NACI) registry.

High-speed rotational atherectomy (RA) is a new percutaneous procedure for treatment of coronary stenoses that operates by the unique mechanism of plaque abrasion. This article reports acute (in-hospital) outcomes and 1-year follow-up in a large cohort of patients treated with this device by NACI investigators. A total of 525 patients with 670 lesions treated with RA form the substrate of this report. Patients tended to be older (mean age 64.8 years) than those in previously reported series of percutaneous transluminal coronary angioplasty (PTCA), with more extensive disease and more complex lesions. Calcification was present in 54% of lesions, and eccentricity in 41%. Balloon angioplasty postdilation was performed after RA in 88% of cases. Angiographic and procedural success (angiographic success without death, Q-wave myocardial infarction [MI] or emergency coronary artery bypass graft [CABG] surgery) rates were 89% and 88%, respectively. Acute in-hospital events included 4 deaths (1%) and 1 emergency CABG surgery (0.4%). MI occurred in 6% of patients, consisting predominantly of non-Q-wave MI (5%). After RA, angiographic complications included coronary dissection (12%), abrupt closure (5%), side branch occlusion (3%), and distal embolization (3%). Most of these were resolved after postdilation except for coronary dissection, which was present in 15% of lesions treated. Mean length of stay was 3 days. At 1-year follow-up, 27% of patients required target lesion revascularization and 30% had experienced death, Q-wave MI, or target lesion revascularization. Preprocedural characteristics that independently predicted 1-year death, Q-wave MI, or target lesion revascularization were male gender, high risk for surgery, target lesions that were proximal to or in bifurcations, eccentric, long, or highly stenosed. RA, even when applied to lesions of traditionally unfavorable morphology, appears to provide reasonable procedural and angiographic success rates. Restenosis and progression of disease contribute to subsequent clinical and procedural events.

Aged↗