Search PubMedSearch

Biomedical subjects

J W Martin

Publications and source records attributed to J W Martin.

At least 19 recordsLinked to original sources

An acrylic resin core for processing silicone facial prostheses.

A technique is presented for making an acrylic resin core for processing silicone facial prostheses. This technique ensures a durable core that can be used to make multiple prostheses. The core resists fungal growth during storage and creates a smooth, easily cleanable internal surface for a facial prosthesis. The core also permits a controllable thickness and therefore a lighter prosthesis.

Acrylic Resins

A flasking technique for microwave processing of silicone prostheses.

Polyvinylchloride plumbing parts provide a readily available source of material to use in making facial prostheses. Inexpensive pipe fittings (end cap attachments and closet flanges) can be combined to provide a durable container for stone molds that can be tightened in a strong curing press. The entire unit can be cured in a microwave oven in 30 minutes.

Dental Prosthesis Design

Modified technique for preparing a polyurethane lining for facial prostheses.

A simplified technique for preparing, under a vacuum, a polyurethane lining for a facial prosthesis is described. A previously presented technique strengthened the prosthesis and allowed it to be attached with a water-based adhesive. This technique eliminates wrinkling, simplifies bonding, allows multiple linings to be made at the same time, conserves time and cost, and improves predictability of the results.

Ear, External

Postoperative blood retrieval and transfusion in cementless total knee arthroplasty.

Postoperative wound drainage was aspirated, collected, and transfused in 197 patients undergoing unilateral or bilateral cementless knee arthroplasty using the Solcotrans or the Constavac Blood Conservation blood-retrieval devices. Operative technique, method of hemostasis, and postoperative management were identical in all patients. Drainage-tube suction pressure was minimized, and the duration of drainage collection was less than 8 hours in all patients. In the 153 patients who underwent unilateral total knee arthroplasty (TKA), the amount of blood retrieved and transfused averaged 829 cm3 (59% of total blood lost). For the 44 patients who underwent bilateral procedures, 1,131 cm3 of blood was salvaged (56% of total blood lost). Transfused banked blood averaged 1.7 units (25% homologous) in unilateral cases, while bilateral procedures required 3.0 units (35% homologous). Complications (4%) included wound hematomata in five patients and deep venous thrombosis in two. Transient chills, fever, or tachycardia were seen in four patients at the time of transfusion. Transfusion requirements of banked blood appeared to be significantly reduced, especially in simultaneous bilateral knee arthroplasty, when compared to previous experience in patients who did not undergo postoperative blood retrieval.

Blood Transfusion, Autologous

Varied presentations and responses to treatment of infections caused by Mycobacterium haemophilum in patients with AIDS.

We describe three patients with AIDS who developed clinically significant infection with Mycobacterium haemophilum. One patient had skin and bone involvement and suspected laryngeal involvement; the second had extensive abdominal adenopathy with partial bowel obstruction; and the third presented with limited skin involvement. Each patient responded transiently to antimycobacterial therapy, but disease recurred and progressed in all three cases. Recovery of M. haemophilum requires a high level of clinical suspicion and special handling of mycobacterial cultures by the microbiology laboratory, including cultivation on enriched chocolate agar or heme-supplemented media and incubation at 30 degrees C for up to 8 weeks. Characteristic patterns of drug susceptibility for this organism have been only partially defined. Reported responses to antimycobacterial therapy in AIDS patients with M. haemophilum infection have been poor, and the optimal therapeutic regimen is not yet known. The prognosis for recovery appears to depend heavily on host-related factors, particularly the degree of immunosuppression.

Acquired Immunodeficiency Syndrome

Extraoral retention of an obturator prosthesis.

In this study, a technique is described by which large obturators can be retained with an acrylic resin head plate. The technique entails attaching the prosthesis to an acrylic resin plate with a 2-mm-diameter wire and then attaching the plate to the patient's forehead with skin tape.

Aged

Multidisciplinary teamwork in the treatment and rehabilitation of the head and neck cancer patient.

The advantages of multidisciplinary treatment planning of head and neck cancer patients is described. Planning rehabilitation concurrently with curing the malignancy results in the most effective application of treatment modalities coordinated with rehabilitative care. Concentrated multidisciplinary treatment reduces post treatment morbidity by shortening recovery and rehabilitation time.

Head and Neck Neoplasms

An analysis of screw fixation of the femoral component in cementless hip arthroplasty.

A cementless hip stem that allows screw fixation of the collar to cortical bone in the calcar region was found to achieve enhanced rotational stability when implanted in preserved cadaveric human femora. Although the implants with screws showed less tendency for subsidence than the implants without screws, rotational micromotion was not found to be statistically different under light loading conditions. When implanted in composite bone, the addition of screws in the configuration tested was associated with significant metal-on-metal wear during combined compression and rotational cyclic loading. This finding is of concern due to potential wear particle toxicity and possible lowered fatigue life of the prosthesis. Therefore, specific design changes are recommended.

Biomechanical Phenomena

Determination of organic contaminants in residential indoor air using an adsorption-thermal desorption technique.

This field study evaluated the ability of a multi-sorbent sampling tube/thermal desorption technique to identify and to provide quantitative data on volatile organic contaminants in indoor air. Air samples, from 12 Canadian homes, were collected on multilayer sorbent cartridges and analyzed using Adsorption/Thermal Desorption coupled with Gas Chromatography/Mass Spectrometry. The study included the identification and quantitation of 23 target compounds. Analysis of sorbent tubes fortified with these target compounds indicated that recoveries were greater than 70 percent and the precision was usually better than 15 percent. These organic compounds were found to be stable on the sorbent tubes for at least seven days. With some exceptions, the target compounds were usually detected at 1 to 10 micrograms/m3 in indoor air samples; other organics identified qualitatively were saturated hydrocarbons, unsaturated hydrocarbons, cyclic hydrocarbons, substituted aromatics, oxygenates, some halogenates and cyclic species such as camphenes/pinenes and carenes.

Adsorption

Oral complications associated with cancer therapy. An M. D. Anderson Cancer Center experience.

Oral complications associated with cancer therapy may not be inevitable. The intensity and duration can be prevented or alleviated by correcting existing oral-dental pathology and maintaining meticulous oral care. Microbial (bacterial, fungal and viral) assessment not only allows appropriate documentation of mucositis versus mucosal infection but directs therapeutic treatment.

Bacterial Infections

The influence of joint line position on knee stability after condylar knee arthroplasty.

Using a special knee-testing device, ten knees obtained at autopsy were subjected to varus-valgus, anterior-posterior, and flexion-rotation analysis in the intact state and after total knee arthroplasty. The ten knees showed no significant change in stability after knee replacement when the joint line was maintained in its natural position. When the femoral component was repositioned 5 mm proximally and 5 mm anteriorly, a significant increase in laxity occurred during midflexion. When the joint line was shifted 5 mm distal and 5 mm posterior to its anatomic location, significant tightening occurred in midrange of motion. Coupled rotation of the tibia with knee flexion was decreased after surgery in all knees with no specific relationship to joint line position. Coupled rotation with varus-valgus testing, however, remained within the normal range through the first 30 degrees of flexion only when the joint line was restored to its normal anatomic position. Stability in condylar knee arthroplasty is in part dependent on position of the joint line. Surgical techniques that rely on restoring the flexion and extension gap without regard to joint line position may result in alteration of varus-valgus or anterior-posterior displacement in midrange flexion.

Biomechanical Phenomena

Electrotherapy and hyperbaric oxygen: promising treatments for postradiation complications.

Electrotherapy and hyperbaric oxygen therapy have been added to physical therapy to treat patients with postsurgery and radiation sequelae. Problems of reduced oral opening and range of head movement, soft tissue necrosis, osteoradionecrosis, and delayed wound healing were addressed in 37 patients over a 3-year period. Of this group, 16 irradiated maxillary resection patients were specifically followed up to determine the effectiveness of the new modalities on improving reduced oral opening. Although healing and the quality of the soft tissues showed marked improvement there was no significant improvement in oral opening.

Acupuncture Therapy

The labial plate major connector in the partial mandibulectomy patient.

The indications, design, and advantages of the labial plate major connector as compared with the labial and lingual bar major connector are reviewed. The mechanical principles of increased rigidity and strength are discussed. The article suggests that the labial plate major connector may have an advantage over the labial bar major connector and should be considered when a labial connector is indicated.

Denture Design

A32390A, a new biologically active metabolite. II. Isolation and structure.

An inhibitor of dopamine-beta-hydroxylase, designated A32390A, was isolated from the culture broth of a Pyrenochaeta species. The inhibitor showed antimicrobial activity against fungi and gram-positive bacteria. Spectroscopic analysis and chemical degradation studies indicated that the structure was 1,6-di-O-(2-isocyano-3-methylcrotonyl)-D-mannitol.

Animals

Pedi-pack transfusion in a newborn intensive care unit.

Two hundred and ninety-one transfusions using 221 pediatric frozen red blood cell packs (Pedi-Packs) were given to 141 newborn babies and infants in the newborn intensive care unit. In 18 patients, 47 transfusions were studied for transfusion and clinical characteristics. Two possible hemolytic episodes are described in detail and remain unexplained. Blood loss for laboratory tests was found to average 3.1 ml/kg per day spent in the newborn intensive care unit. The rise in hematocrit was found to be excellent. Overall, the transfusion of thawed pediatric red blood cell packs was found to be convenient, safe and effective. Because of pretesting possibilities with the use of this source of red blood cells, one of the problems associated with a walking donor program is eliminated.

Anemia