Search PubMed⌕ Search

Biomedical subjects

J W Hall

Publications and source records attributed to J W Hall.

At least 127 records · Page 7Linked to original sources

The status of state-wide policies for neonatal hearing screening.

During the process of establishing follow-up procedures for our neonatal hearing program, we became interested in the current status of screening programs nationwide. Fifty states and the District of Columbia were surveyed to determine the extent and content of legislatively mandated neonatal hearing screening programs. Fourteen states have legislative mandates for screening and, at this point, approximately 50 percent of the states have no state-wide policy regarding neonatal hearing screening. Among the various state-wide protocols two basic approaches emerged: (1) the high-risk register and (2) in-hospital screening. In addition, information was obtained on screening methods, the level of program implementation, and some of the pros and cons for mandating neonatal hearing screening.

Audiology↗

The masking-level difference in children.

The masking-level difference (MLD) was investigated in children aged 3.9 to 9.5 years and in an adult control group in order to examine the development of the MLD with age. A three-alternative forced-choice adaptive tracking procedure was used for all listeners. MLDs were determined for a 500-Hz pure-tone signal presented in a 300-Hz-wide masking noise centered on 500 Hz, where both interaural time and amplitude cues were present, and in 40-Hz-wide maskers centered on 500 Hz, where either amplitude (MLD delta a) or time (MLD delta t) cues were present. The masking noise level was fixed at 60 dB/Hz SPL. For the 300-Hz-wide masker, the MLDs of the children increased in magnitude up until the age of 5 or 6 years. For the 40-Hz-wide maskers, the MLDs of the 5- and 6-year-old children were still somewhat below adult values. It is possible that these differences between adults and children are related to the development of the peripheral/brainstem auditory system. By this interpretation, the MLD might be small in young listeners because the interaural time and amplitude cues underlying the MLD are coded with relatively poor precision. However, it is perhaps more likely that these differences are coded precisely in the peripheral auditory system, but that more central auditory processes are relatively inefficient in extracting the interaural information.

Acoustic Stimulation↗

A simplified technique for transtympanic electrocochleography.

Recently, electrocochleography (ECochG) has enjoyed a resurgence in clinical use, particularly in the preoperative and intraoperative evaluation of Meniere's disease patients. With a transtympanic electrode, large amplitude, repeatable waveforms can be easily recorded. Despite this fact, transtympanic ECochG has not been widely adopted in the United States, primarily because of the technical difficulties in securing the electrode and then delivering a stimulus. We have developed a simplified transtympanic electrode placement, using a standard subdermal needle held in place by a foam plug earphone. The foam plug earphone not only secures the electrode, but also delivers the stimulus. We have used this technique in a series of cases, both intraoperatively as well as in the outpatient clinic. The advantages of this approach are discussed and illustrated with individual and group data.

Adult↗

Comodulation masking release using SAM tonal complex maskers: effects of modulation depth and signal position.

The purpose of this investigation was to examine two stimulus parameters that were reasoned to be of importance to comodulation masking release (CMR). The first was the degree of fluctuation, or depth of modulation, in the masker bands, and the second was the temporal position of the signal with respect to the modulations of the masker. The investigation began by demonstrating the efficacy of sinusoidally amplitude-modulated (SAM) tonal complex maskers in eliciting CMR. "Nine-band" maskers, 650 ms in duration, were constructed by adding together nine SAM tones spaced at 100-Hz intervals from 300 to 1100 Hz. The rate of modulation for each SAM tone was 10 Hz, and the depth of modulation was 100%. Using such maskers, it was shown that when the on-frequency SAM tone had a modulation depth of 100%, the threshold for a 250-ms, 700-Hz tone improved monotonically as the modulation depths of the flanking SAM tones increased from 0% to 100%. When the on-frequency SAM tone had a modulation depth of 63%, some listeners performed optimally when the flanking SAM tones also exhibited a modulation depth of 63%, whereas others performed best when the flankers had modulation depths of 100%. With regard to signal position, a typical CMR effect was observed when the signal, consisting of a train of three 50-ms, 700-Hz tone bursts, was placed in the dips of the on-frequency masker. However, when the signal was placed at the peaks of the envelope, an increase in masking was observed for a comodulated masker.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Spectrotemporal analysis and cochlear hearing impairment: effects of frequency selectivity, temporal resolution, signal frequency, and rate of modulation.

The detection of 500- or 2000-Hz pure-tone signals in unmodulated and modulated noise was investigated in normal-hearing and sensorineural hearing-impaired listeners, as a function of noise bandwidth. Square-wave modulation rates of 15 and 40 Hz were used in the modulated noise conditions. A notched noise measure of frequency selectivity and a gap detection measure of temporal resolution were also obtained on each subject. The modulated noise results indicated a masking release that increased as a function of increasing noise bandwidth, and as a function of decreasing modulation rate for both groups of listeners. However, the improvement of threshold with increasing modulated noise bandwidth was often greatly reduced among the sensorineural hearing-impaired listeners. It was hypothesized that the masking release in modulated noise may be due to several types of processes including across-critical band analysis (CMR), within-critical band analysis, and suppression. Within-band effects appeared to be especially large at the higher frequency region and lower modulation rate. In agreement with previous research, there was a significant correlation between frequency selectivity and masking release in modulated noise. At the 500-Hz region, masking release was correlated more highly with the filter skirt and tail measures than with the filter passband measure. At the 2000-Hz region, masking release was correlated more with the filter passband and skirt measures than with the filter tail measure. The correlation between gap detection and masking release was significant at the 40-Hz modulation rate, but not at the 15-Hz modulation rate. The results of this study suggest that masking release in modulated noise is limited by frequency selectivity at low modulation rates, and by both frequency selectivity and temporal resolution at high modulation rates. However, even when the present measures of frequency selectivity and temporal resolution are both taken into account, significant variance in masking release still remains unaccounted for.

Acoustic Stimulation↗

Gap detection as a function of stimulus bandwidth with fixed high-frequency cutoff in normal-hearing and hearing-impaired listeners.

Gap detection was measured as a function of noise bandwidth with constant high-frequency cutoff in both normal-hearing and cochlear-impaired listeners. Band-widening functions were measured in a low-frequency region (0.6-kHz upper cutoff) and a high-frequency region (2.2-kHz upper cutoff). Measures of frequency selectivity were also obtained in the two frequency regions. The results for the normal-hearing listeners indicated that, on a double logarithmic scale, gap thresholds improved more steeply with increasing bandwidth in the higher frequency region than in the lower. However, performance at the narrow bandwidths was independent of frequency region. For the cochlear-impaired listeners, gap thresholds were generally longer than normal in both frequency regions. However, in the higher frequency region, progressively more listeners approached normal values as bandwidth was increased. The elevated gap thresholds were due in part to the higher absolute thresholds and in part to poor ability to process stimulus fluctuation. No correspondence was found between gap detection performance and frequency selectivity.

Acoustic Stimulation↗

Hypo- and hyperthermia in clinical auditory brain stem response measurement: two case reports.

Two case reports are presented to highlight the important effects of body temperature in clinical auditory brain stem response (ABR) measurement. Case 1 is an 11 year old boy in coma secondary to severe head injury. High dose barbiturate therapy suppressed brain stem neurologic signs and the ABR was relied on as a monitor of CNS status. Hypothermia during this period of intensive care was a crucial factor for meaningful interpretation of ABR findings. The second case was a 26 year old male undergoing hyperthermic therapy for advanced cancer. As body temperature increased from 38 to 42 degrees Centigrade (107.6 degrees Fahrenheit), there was a systematic decrease in latency for waves III and V. An overall hyperthermia-related decrease in the wave I-V latency interval of 0.5 to 0.6 milliseconds was observed on two test dates. ABR results for these two cases are discussed in the context of basic knowledge on body temperature and auditory electrophysiology.

Adult↗

Comodulation masking release for multicomponent signals.

Detection of signals composed of one, two, or three pure-tone components was examined in comodulated and noncomodulated masking noises. The masking noise was either a single 30-Hz-wide narrow band of noise, two narrow bands of noise, or three narrow bands of noise. Comodulation masking release (CMR) was greatest when (1) the signal was a single pure tone; (2) the masker was composed of three noise bands (as opposed to two); and (3) at least one flanking band was lower in frequency than the signal. Substantial CMRs did occur, however, for two- and three-component signals presented in two- and three-component maskers, respectively. The results of the present experiments did not support a "dip listening" hypothesis, nor models based strictly on across-frequency differences in stimulus envelope pattern or correlation. The results were more consistent with a model of CMR in which across-frequency envelope difference is coded by subtracting the envelope at the signal frequency from the envelope at a flanking frequency.

Acoustic Stimulation↗

The effect of masker interaural phase on the detection of a monaural signal.

The masking-level difference (MLD) for a 500-Hz monaural pure-tone signal was examined as a function of the interaural phase shift of a 100-Hz-wide noise band centered on 500 Hz. Results indicated that the MLD decreased in magnitude as the interaural phase shift of the masker increased. In a second experiment, the 100-Hz-wide noise band was used as both the masker and the signal in order to examine the detection cues of interaural time difference and interaural level difference separately. Again, the interaural phase of the masker was varied, and an Sm signal was presented. Results indicated that the MLD decreased as a function of increasing masker interaural temporal difference for the time cue, but that the MLD did not change systematically for the level cue. The deterioration of binaural detection as a function of increasing masker interaural phase difference was not as great as that which has been reported in localization and lateralization experiments.

Auditory Perception↗

Combined monaural and binaural masking release.

Stimulus conditions were examined where both across-frequency [comodulation masking release (CMR)] and across-ear [binaural masking-level difference (BMLD)] cues were available, as well as conditions where only one of these cue types was available. The main goal of the study was to determine how the two types of cues combine. The effects of comodulation were assessed either by modulating a masking noise and manipulating its bandwidth (experiment 1) or by using two comodulated narrow bands of noise separated in frequency (experiment 2). The masker was always No, and the 500-Hz pure-tone signal was either So or S pi. The effect of the frequency of modulation was examined either by changing the frequency of the modulating stimulus (experiment 1) or by changing the bandwidth of the comodulated narrow-band noise (experiment 2). Four of six subjects showed greater masking release when both BMLD and CMR cues were available than for either type of cue alone, whereas the other two subjects did not show an ability to combine the two cues for additional advantage. For the subjects who were able to combine the two types of cue, the additional advantage was greater for low frequencies of modulation. The results indicate that one component of CMR may be based upon across-frequency envelope comparisons at a stage of processing after binaural analysis.

Adolescent↗

Spectro-temporal analysis in normal-hearing and cochlear-impaired listeners.

Detection thresholds for a 1.0-kHz pure tone were determined in unmodulated noise and in noise modulated by a 15-Hz square wave. Comodulation masking release (CMR) was calculated as the difference in threshold between the modulated and unmodulated conditions. The noise bandwidth varied between 100 and 1000 Hz. Frequency selectivity was also examined using an abbreviated notched-noise masking method. The subjects in the main experiment consisted of 12 normal-hearing and 12 hearing-impaired subjects with hearing loss of cochlear origin. The most discriminating conditions were repeated on 16 additional hearing-impaired subjects. The CMR of the hearing-impaired group was reduced for the 1000-Hz noise bandwidth. The reduced CMR at this bandwidth correlated significantly with reduced frequency selectivity, consistent with the hypothesis that the across-frequency difference cue used in CMR is diminished by poor frequency selectivity. The results indicated that good frequency selectivity is a prerequisite, but not a guarantee, of large CMR.

Adult↗

Comodulation masking release: evidence for multiple cues.

Signal detection was determined in conditions where the masker was a 10-Hz-wide noise band centered on the signal, and in conditions where either a comodulated or noncomodulated noise band (centered at 0.8 times the signal frequency) was also present. Signal frequencies of 500 or 2000 Hz were investigated. In one condition of the first experiment, the signal was exactly the same 10-Hz-wide noise band as the masker, added to the masker in phase. This condition was designed to limit the availability of cues based upon dip listening, suppression, beating, or across-frequency differences in noise envelope correlation, but to afford a cue based upon across-frequency envelope amplitude difference. The narrow-band noise signal resulted in approximately the same magnitude of comodulated masking release (CMR) as was found for a pure-tone signal. This result suggested that one important cue for CMR is an across-frequency difference in envelope amplitude. Stimulus conditions in the second experiment were intended to disrupt cues of across-frequency envelope amplitude difference, but to afford cues based upon across-frequency differences in noise envelope correlation. In this experiment, cues based upon envelope amplitude were impoverished by randomly varying the level of the flanking band from interval to interval, and by adjusting the level in the on-signal band to be the same in the nonsignal intervals as the level of noise plus signal in the signal interval. Again, substantial CMRs occurred, suggesting that another cue for CMR may be envelope pattern or correlation. The results of these experiments indicated that CMR is probably based upon more than one stimulus variable.

Adult↗

Binaural hearing after middle ear surgery. Masking-level difference for interaural time and amplitude cues.

Previous investigations have shown that binaural hearing is often abnormal in patients having conductive hearing losses, and even in patients who have had hearing thresholds corrected by middle ear surgery. The present study assessed further the masking-level difference (MLD) in patients who had previously undergone middle ear surgery. The stimuli were chosen such that the sensitivity to interaural time difference cues and to interaural amplitude difference cues could be assessed independently. Results indicated that the MLD is abnormal in more than a third of 15 patients, even after surgery has restored normal hearing at the frequency of the test. The MLD is more likely to be reduced for the cue of interaural time difference than for interaural amplitude difference. Subjects who had lesions of long duration, early onset, and large asymmetry were particularly likely to have reduced MLDs.

Adolescent↗

Relationships between age, body weight, and season of the year and the incidence of sudden death syndrome in male broiler chickens.

The aim of this study was to examine relationships between the incidence of sudden death syndrome (SDS) in male broiler chickens and age, body weight, and season of the year. The data used were from 23 experiments conducted from July 1982 to June 1987 involving a total of 89,988 chickens aged 1-day to a maximum of 70 days. All chickens that died during the experiments were necropsied and the incidence of SDS noted. Incidence of death from SDS as a percentage of mortality ranged from 1.31 to 9.62% among experiments. Death rate from SDS showed a significant increase with body weight. The SDS mortality rate reached a maximum when birds were between 21 and 27 days of age. Death rate from SDS increased up to about 21 days and remained between 80 and 86/100,000 chickens per day to 39 days, with a gradual decline to the end of the observation period (63 days), when it was 54/100,000 per day. Death rate from SDS may be related to the month in which the experiment started, with the highest mortality occurring in January and the lowest in July. Correlations between death rates from SDS and other causes were not significant.

Age Factors↗

Auditory evoked responses in the management of acutely brain-injured children and adults.

In recent years, the role of auditory evoked responses (AERs) in the intensive care unit (ICU) setting has expanded dramatically for both pediatric and adult brain-injured patient populations. AERs have unique value in early identification and evaluation of peripheral auditory dysfunction that can result directly from head trauma or as a consequence of intensive medical therapy (such as prolonged intubation and ototoxic drugs). AERs can also be applied in evaluating and monitoring neurologic status during the acute period following a severe brain injury, similar to their common intraoperative use as a neurophysiologic monitor. This paper reviews factors influencing measurement of AERs in the ICU, including the effect of (1) intensive medical therapy (e.g., neuromuscular blockers, sedatives, barbiturates, aminoglycosides, and loop diuretics); (2) coma; and (3) computed tomography confirmed temporal bone fracture. The rationale for monitoring neurologic status with AERs in this setting is presented and supported with original group data. Important points are illustrated with selected case reports.

Adolescent↗

Unusual complications of temporal bone fractures.

Eighty-two temporal bone fractures were diagnosed in 75 patients with high-resolution computed tomographic scanning. Excluding six gunshot injuries, 55 (72%) of the fractures were oblique, 11 (15%) were longitudinal, and ten (13%) were transverse. Facial paresis or paralysis occurred in 45 patients (60%), hemotympanum occurred in 67 (89%), and cerebrospinal fluid otorrhea occurred in 19 (25%). Among 66 patients in whom audiometry was performed, 20 (30%) had conductive hearing loss, nine (14%) had sensorineural loss, and 36 (55%) had mixed hearing loss. Vestibular symptoms were present in 23 patients (30%). Other unusual complications of temporal bone fractures were observed: bilateral abducens paralysis, three patients (4%); unilateral abducens paralysis, two (2.67%); trigeminal paralysis, one (1.33%); and aseptic sigmoid sinus thrombosis, one (1.33%).

Abducens Nerve Injury↗