Search PubMed⌕ Search

Biomedical subjects

J W Hall

Publications and source records attributed to J W Hall.

At least 91 records · Page 5Linked to original sources

Near-infrared spectroscopic determination of serum total proteins, albumin, globulins, and urea.

We have determined total protein, albumin, globulins, and urea in unmodified human serum using near-infrared (NIR) spectroscopy. The distinctive NIR spectrum of the individual protein fractions allowed unique spectroscopic models to be derived for each fraction using multiple linear least-squares regression (MLR). A more sophisticated partial least-squares (PLS) regression analysis was necessary to fully extract the relevant spectral information for urea. The serum protein data sets consisted of 235 calibration samples and 85 prediction samples. The total protein calibration yielded a multiple correlation coefficient (R) of 0.986 and a standard error of calibration (SEC) of 1.7 g/L. For the validation data set, a correlation coefficient (r) of 0.985 and standard error of prediction (SEP) of 1.7 g/L were obtained. For albumin, the values were R = 0.982 and SEC = 1.2 g/L for calibration and r = 0.984 and SEP = 1.1 g/L for prediction. Calibration results for globulins were R = 0.916 and SEC = 2.1 g/L; validation results were r = 0.885 and SEP = 2.2 g/L. The sum of the separately estimated albumin and globulin fractions agreed well with the total protein estimate. For urea, the calibration model (n = 422) provided an R = 0.994 and SEC = 0.7 mmol/L and the validation results (n = 208) were r = 0.993 and SEP = 0.8 mmol/L. The within-day and between-day precision values (CVs) were respectively, 1.2 and 1.3% for total protein, 1.7 and 1.1% for albumin, 1.5 and 1.3% for globulins, and 8.3 and 5.5% for urea.

Blood Proteins↗

The effect of otitis media with effusion on the masking-level difference and the auditory brainstem response.

This study investigated the masking-level difference (MLD) and auditory brainstem response (ABR) in a group of children with a history of otitis media with effusion (OME) and a control group of children with no known history of ear disease. All children had normal hearing at the time of testing. The main goal of the study was to determine whether there was an association between a reduced MLD in the OME children and an abnormal ABR (in terms of prolonged absolute or interwave intervals, or interaural differences in the ABR waveforms). The results indicated that the group of children having a history of OME had significantly reduced MLDs and had significantly prolonged waves III and V, and I-III and I-V interwave intervals. The correlations between MLD and delays in absolute wave or interwave intervals were not significant. However, some correlations between interaural asymmetries of the interwave intervals and the MLD were significant. The results suggest that the reduction in MLD found in children having a history of OME may be related to abnormal brainstem processing.

Audiometry, Pure-Tone↗

Temporal analysis in children.

This study investigated the development of temporal resolution as a function of frequency region using a modified masking period pattern paradigm. This paradigm also allowed age-dependent comparisons of within-channel (temporal resolution) versus across-channel (comodulation masking release [CMR]) processing of temporal information to be made in the same listeners. The results indicated that temporal resolution improves with age. At low frequencies, this improvement continues beyond 10 years of age, whereas at high frequencies performance approaches adult levels by about age 6. Although it is reasonable to expect an association between CMR and temporal acuity, the measure of CMR did not show a significant age effect. The possibility was raised that the poorer temporal resolution of children may not reflect simply a deficiency in peripheral processing of temporal information.

Adult↗

Influence of frequency selectivity on comodulation masking release in normal-hearing listeners.

Experiments 1 and 2 investigated the effect of frequency selectivity on comodulation masking release (CMR) in normal-hearing subjects, examining conditions where frequency selectivity was relatively good (low masker level at both low [500-Hz] and high [2500-Hz] signal frequency, and high masker level at low signal frequency) and where frequency selectivity was somewhat degraded (high masker level and high signal frequency). The first experiment investigated CMR in conditions where a narrow modulated noise band was centered on the signal frequency, and a wider comodulated noise band was located below the band centered on the signal frequency. Signal frequencies were 500 and 2000 Hz. The masker level and the frequency separation between the on-signal and comodulated flanking band were varied. In addition to conditions where the flanking band and on-signal band were presented at the same spectrum level, conditions were included where the spectrum level of the flanking band was 10-dB higher than that of the on-signal band, in order to accentuate effects of reduced frequency selectivity. Results indicated that CMR was reduced at the 2000-Hz region when masker level was high, when the frequency separation between on-signal and flanking band was small, and when a 10-dB level disparity existed between the on-signal and flanking band. In the second experiment, CMR was investigated for narrow comodulated noise bands, presented either without any additional sound or in the presence of a random noise background. CMR increased slightly as the masker level increased, except at 2500 Hz when the noise background was present. The decrease in CMR at 2500 Hz with the high masker level and with a noise background present could be explained in terms of reduced frequency selectivity. In a third experiment, we compared performance for equal absolute bandwidth maskers at a low (500-Hz) and a high (2000-Hz) stimulus frequency. Results here suggested that detection in modulated noise may be reduced due to a reduction in the number of quasi-independent auditory filters contributing temporal envelope information. The effects found in the present study using normal-hearing listeners under conditions of degraded frequency selectivity may be useful in understanding part of the reduction of CMR that occurs in cochlear-impaired listeners having reduced frequency selectivity.

Auditory Perception↗

Monaural envelope correlation perception in listeners with normal hearing and cochlear impairment.

Monaural envelope correlation perception was investigated in listeners with normal hearing and in listeners with cochlear hearing loss. Using a three-interval forced-choice procedure, the task of the subject was to identify the one interval out of three where the noise bands had correlated envelopes. Performance was determined as a function of the spectral separation between noise bands (delta f of 250, 500, or 1000 Hz) and the number of noise bands present (two, three, or five). Although individual differences existed, the results generally indicated better performance for the listeners with normal hearing when the delta f between bands was relatively small; however, there was no significant effect of hearing loss when the frequency separation between bands was greater than 250 Hz. The listeners with normal hearing generally showed decreased performance with increasing delta f, whereas the performance of many of the listeners with hearing impairment usually did not change appreciably with variation in delta f. Both groups of listeners showed improved performance with increasing number of noise bands present for the 500-Hz delta f. Only the listeners with hearing impairment showed significantly improved performance with increasing band number for the 250-Hz delta f; neither group showed improved performance with increasing band number for the 1000-Hz delta f. With five bands present, the performance of the listeners with hearing impairment did not differ significantly from that of the listeners with normal hearing, even for the 250-Hz delta f.(ABSTRACT TRUNCATED AT 250 WORDS)

Acoustic Stimulation↗

Comodulation masking release in subjects with unilateral and bilateral hearing impairment.

Three subjects with unilateral cochlear hearing loss and three subjects with bilateral cochlear hearing loss were tested in three experiments. In the first, their auditory filter shapes were measured for center frequencies of 700 and 2000 Hz, using the notched-noise method. The auditory filters were generally broader for the impaired than for the normal ears. In experiment 2, the threshold for detecting a 2000-Hz signal centered in a band of noise was measured as a function of the noise bandwidth for a Gaussian noise, and for that same noise multiplied (modulated) by a second noise low-pass filtered at 12.5 Hz. For the Gaussian noise, thresholds increased up to a certain noise bandwidth and then flattened off. This bandwidth was usually greater for the impaired than for the normal ears, consistent with the broader auditory filters of the impaired ears. For the modulated noise, thresholds tended to decrease when the noise bandwidth was increased beyond a certain value, indicating comodulation masking release (CMR). The decrease occurred at wider bandwidths for the impaired than for the normal ears. For the unilaterally impaired subjects, the amount of decrease was smaller for the impaired than for the normal ears when tested at equal SPL, but not when tested at equal SL. In experiment 3, the threshold for detecting a 700-Hz signal centered in a 20-Hz-wide band of noise (the on-frequency band, ONB) was measured in the presence of eight flanking bands (FBs) whose envelopes were either identical with that of the ONB (correlated condition) or were uncorrelated. CMR was defined as the difference in threshold between the correlated and uncorrelated conditions. The ONB and the FBs were presented either to the same ear (monaural condition) or to opposite ears (dichotic condition). CMRs tended to be greatest at high levels of the ONB and the FBs. CMRs in the monaural condition were smaller for hearing-impaired than for normal ears. However, at high levels, CMRs in the dichotic condition were similar for normal, bilaterally impaired, and unilaterally impaired subjects. In the latter case, CMRs were similar when the ONB was presented to the normal ear and to the impaired ear of each subject.(ABSTRACT TRUNCATED AT 400 WORDS)

Acoustic Impedance Tests↗

Comodulation masking release: is comodulation sufficient?

Common amplitude modulation across frequency facilitates comodulation masking release (CMR) and may also contribute to auditory grouping. The purpose of the present investigation was to determine whether there is an association between these two phenomena; that is, does the occurrence of CMR require that the comodulated noise bands making up the composite masker be grouped together? Three experiments were undertaken, each manipulating one variable designed to hinder the fusion of the comodulated noise bands. In experiment 1, the variable of onset/offset asynchrony was observed to have a marked effect: CMR could be completely abolished if the asynchrony between the on-signal band and the flanking bands was sufficiently great (> or = 50 ms). In experiment 2, an auditory streaming paradigm was employed and this was observed to disrupt CMR significantly. However, a substantial CMR remained. Experiment 3 attempted to hinder the fusion of the comodulated noise bands by drawing the various noise bands into separate harmonic series. However, the small effect observed did not appear to be due to a parsing of the fused image. Results from experiments 1 and 2 suggest that the CMR mechanism does not act in isolation from the processes that give rise to auditory object formation. In particular, the cue of onset/offset synchrony appears to be of paramount importance.

Acoustic Stimulation↗

Short-term and long-term effects on the masking level difference following middle ear surgery.

The masking-level difference (MLD) was measured in a group of adult listeners having unilateral otosclerosis before stapedectomy surgery, 1 month following surgery, and 1 year following surgery. The results indicated that the MLD in this group improved significantly over each of the sequential tests. In contrast, for a group of normal-hearing listeners, the MLD did not change significantly over sequential testing. The results support an interpretation that a period of exposure to abnormal binaural auditory input (as occurs in a unilateral conductive loss) can blunt sensitivity to binaural cues after normal binaural input has been restored in most adult listeners, however, there appears to be a relatively long-term readjustment or adaptation, such that the sensitivity to binaural cues recovers to a normal or near-normal level at the 1-year postsurgery retest. Two of eight listeners did not show recovery to a normal MLD value over this time period. The efficiency and rate of readjustment may differ among individuals.

Acoustic Stimulation↗

Dynamic sensorineural hearing loss: implications for audiologists: case reports.

Although many persons with sensorineural hearing loss (SNHL) seeking hearing care do not have active ear disease, audiologists must appreciate the potentially dynamic and treatable nature of some etiologies of SNHL. This is particularly important now as audiologists are increasingly employed in private practice or other clinical settings that may serve as the point of entry for hearing care. In this paper, we review a variety of clinical entities affecting newborn infants, children, and adults that are associated with dynamic SNHL. Using a case report format, we illustrate treatment-related changes in SNHL, emphasizing the audiologist's role in patient management.

Adult↗

Development of an expert system for pediatric auditory brainstem response interpretation.

Expert systems are computer programs which incorporate artificial intelligence technology and are created to emulate the decision-making abilities of human experts. The advantage of such systems lies in their ability to capture and model expert problem solving knowledge in a domain and make it available to an unlimited number of consumers in an economic and efficient way. The purpose of this project was to develop an expert system to interpret infant auditory brainstem response data as entered by the user. The resulting system provides diagnostic conclusions regarding hearing status, type of hearing loss, and brainstem function at an accuracy level equal to that of a human expert.

Artificial Intelligence↗

Audiologic and otolaryngologic findings in progeria: case report.

Progeria is a rare syndrome, with an estimated incidence of 1 per 250,000 births. Although children with progeria have the appearance of premature aging or senility, the term is misleading because reported cases of progeria have not manifested most physical or biochemical aspects of old age. Many children with progeria appear normal at birth and then progressively, and rather rapidly, develop the characteristic features during early childhood. Although first described in the 1880s, only approximately 100 cases of progeria are reported in the international literature. The single case study of hearing in progeria, which appeared in 1965, is limited to pure-tone and speech audiometry findings. We report the results of otolaryngologic examination and pure-tone, speech, immittance, and auditory brainstem response (ABR) audiometry for a 5-year-old female with progeria. The patient had a mild-to-moderate, bilateral, conductive hearing loss. Immittance measurements were consistent with fixation of the ossicular chain and this was confirmed surgically. Mildly prolonged ABR wave I-V latencies suggest possible auditory central nervous system involvement.

Acoustic Impedance Tests↗

Cryobiological preservation of Drosophila embryos.

The inability to cryobiologically preserve the fruit fly Drosophila melanogaster has required that fly stocks be maintained by frequent transfer of adults. This method is costly in terms of time and can lead to loss of stocks. Traditional slow freezing methods do not succeed because the embryos are highly sensitive to chilling. With the procedures described here, 68 percent of precisely staged 15-hour Oregon R (wild-type) embryos hatch after vitrification at -205 degrees C, and 40 percent of the resulting larvae develop into normal adult flies. These embryos are among the most complex organisms successfully preserved by cryobiology.

Animals↗

Masking release for gap detection.

In random noise, masking is influenced almost entirely by noise components in a narrow band around the signal frequency. However, when the noise is not random, but has a modulation pattern which is coherent across frequency, noise components relatively remote from the signal frequency can actually produce a release from masking. This masking release has been called comodulation masking release (CMR). The present research investigated whether a similar release from masking occurs in the analysis of a suprathreshold signal. Specifically, the ability to detect the presence of a temporal gap was investigated in conditions which do and do not result in CMR for detection threshold. Similar conditions were investigated for the masking level difference (a binaural masking release phenomenon). The results indicated that suprathreshold masking release for gap detection occurred for both the masking-level difference (MLD) and for CMR. However, masking release for gap detection was generally smaller than that obtained for detection threshold. The largest gap detection masking release effects obtained corresponded to relatively low levels of stimulation, where gap detection was relatively poor.

Acoustic Stimulation↗

Comodulation masking release for speech stimuli.

This study sought to determine whether speech recognition in a modulating noise background can be facilitated by a process attributable to comodulation masking release (CMR). Experiment 1 examined the masked identification of six filtered vowels as a function of the number of comodulated noisebands present. A benefit of increased number was observed, consistent with an interpretation in terms of CMR, although it could not be certain that the basis of the discrimination was word recognition in the semantic sense. Experiment 2 made use of a forced-choice rhyming test in which the response foils differed only in a single filtered consonant; again, the measure of interest was performance as a function of the number of comodulated noisebands present. No evidence for a suprathreshold CMR was observed. Experiment 3 made use of open-set sentence material and employed a different paradigm, which allowed a measure of CMR in terms of the difference between thresholds in correlated and uncorrelated noise to be determined. While a CMR for speech detection was observed, no CMR for speech recognition was found. It was concluded that CMR is most evident in masked detection tasks and that diminishing returns are encountered as the signal-to-masker ratio is raised.

Attention↗

The detection of temporal gaps as a function of frequency region and absolute noise bandwidth.

Temporal gap detection was measured as a function of absolute signal bandwidth at a low-, a mid-, and a high-frequency region in six listeners with normal hearing sensitivity. Gap detection threshold decreased monotonically with increasing stimulus bandwidth at each of the three frequency regions. Given conditions of equivalent absolute bandwidth, gap detection thresholds were not significantly different for upper cutoff frequencies ranging from 600 to 4400 Hz. A second experiment investigated gap detection thresholds at two pressure-spectrum levels, conditions typically resulting in substantially different estimates of frequency selectivity. Estimates of frequency selectivity were collected at the two levels using a notched-noise masker technique. The gap threshold-signal bandwidth functions were almost identical at pressure-spectrum levels of 70 dB and 40 dB for the two subjects in experiment II, while estimates of frequency selectivity showed poorer frequency selectivity at the 70-dB level than at 40 dB. Data from both experiments indicated that gap detection in bandlimited noise was inversely related to signal bandwidth and that gap detection did not vary significantly with changes in signal frequency over the range of 600 to 4400 Hz. Over the range of frequencies investigated, the results indicated no clear relation between gap detection for noise stimuli and peripheral auditory filtering.

Adult↗

Cochleovestibular nerve compression syndrome. I. Clinical features and audiovestibular findings.

Cochleovestibular nerve compression syndrome (CNCS) is the term used to describe a group of audiovestibular symptoms thought to be due to a vessel compressing the cochleovestibular nerve. These symptoms include recurrent vertigo, continuous disequilibrium and acquired motion intolerance. Recently, Moller reported that CNCS can be diagnosed based on abnormalities in the auditory brainstem response (ABR). After specifically excluding all other vestibular disorders, 63 patients with symptoms suggestive of CNCS were identified. These patients were systematically evaluated with a standard neurotologic test battery, and the results were reviewed retrospectively. Hearing loss was found in 51 (81%) of 63 cases, including 33 cases of unilateral high-frequency loss and 14 cases of middle-frequency loss. ABR data were interpreted with respect to Moller's criteria, and abnormal studies were found in 42 (75%) of 56 cases. Abnormal electronystagmograms were found in 57 (93%) of 61 cases. Thirteen of the patients subsequently underwent a posterior fossa procedure for vertigo and, vessels were found in contact with the cochleovestibular nerve in 11 of 13 cases. The results of this study suggest that the majority of CNCS patients have neurotologic test findings that suggest an abnormality of the cochleovestibular nerve. The results and their implications are discussed.

Acoustic Impedance Tests↗

Comparison of Etymotic insert and TDH supra-aural earphones in auditory brainstem response measurement.

There are few systematic comparisons of Etymotic ER-3A insert earphones versus supra-aural earphones in auditory brainstem response (ABR) measurement. We compared ER-3A insert earphones and two types of supra-aural earphones (TDH-39P and TDH-49P) in a group of normal hearing adults. Acoustic analyses revealed spectral and temporal differences among earphones. Behavioral and ABR thresholds to click stimuli were slightly elevated with the ER-3A compared to the TDH earphones. The ER-3A earphones produced a latency delay, relative to the TDH earphones, that varied from about 0.8 to 1.0 msec, and increased at lower stimulus intensity levels. In addition, ABR wave I amplitude was significantly reduced with the ER-3A earphone. Based on these data, we recommend collection of normative data with the ER-3A earphones prior to their use in ABR measurement.

Acoustic Stimulation↗