Search PubMedSearch

Biomedical subjects

J W Arndt

Publications and source records attributed to J W Arndt.

At least 19 recordsLinked to original sources

99mTc human immunoglobulin scintigraphy--a reliable method to detect joint activity in rheumatoid arthritis.

The ability of 99mtechnetium labelled nonspecific, polyclonal human immunoglobulin G (99mTc-IgG) scintigraphy to depict and quantify synovial inflammation was studied in 30 patients with rheumatoid arthritis (RA). All patients were injected with 350 MBq 99mTc-IgG and imaging was performed 4 h later. This resulted in excellent images of inflamed synovium. Scores for 99mTc-IgG joint scintigraphy correlated highly with scores for joint swelling and C-reactive protein levels, weakly with pain scores and not with radiographic scores of joint destruction. These results suggest that 99mTc-IgG joint scintigraphy may provide an objective test to detect synovitis and measure the activity of the disease.

Adult

A prospective comparison of 99mTc-labeled polyclonal human immunoglobulin and 111In granulocytes for localization of inflammatory bowel disease.

There is a need for an easily prepared radiopharmaceutical agent for the detection of inflammation and infection. In a group of 14 patients with inflammatory bowel disease (IBD), the detection of actively involved intestinal segments by nonspecific human polyclonal immunoglobulin (IgG) labeled with 99mTc was compared with that of 111In granulocytes. To determine the specificity of 99mTc-IgG scintigraphy, 8 control patients without clinical indications of intestinal inflammation were examined. 99mTc-IgG was found in the left colon in 8 and in the right colon in 7 of the 8 controls 4 hours after the injection. At that time of scintigraphy only 4 IBD patients exhibited a more intense accumulation at the site of the intestinal segments with active disease. In contrast, in a randomized comparison with 111In granulocytes scintigraphy was positive in 11 patients with the latter technique. Moreover, fewer diseased segments were seen in the 4 patients with positive 99mTc-IgG scintigraphy (6 versus 12 with 111In granulocytes). In view of the low sensitivity and specificity, it is concluded that 99mTc-IgG is not suitable for the scintigraphic staging of IBD patients.

Adolescent

Evaluation of the lymph flow with lymphoscintigraphy after rotationplasty for the treatment of bone tumors.

We studied the cases of eleven patients in whom a rotationplasty had been done after wide resection of the distal part of the femur. All patients had had a malignant tumor of bone, but none had the complication of edema or leakage of lymph after the rotationplasty. We made lymphoscintiscans soon after the operation in four patients and weeks or months later in all eleven patients. There was a delay in the flow of lymph in three of the four patients who were examined lymphoscintigraphically soon after the operation and there was obstruction of flow in the fourth patient, but there was evidence of a decreased rate of flow in only two of the eleven patients at the time of the later examination.

Adolescent

Measurement of synovial inflammation in rheumatoid arthritis with technetium 99m labelled human polyclonal immunoglobulin G.

The ability of technetium 99m labelled nonspecific, polyclonal human immunoglobulin G (99mTc-IgG) scintigraphy to depict and quantify synovial inflammation was studied in patients with rheumatoid arthritis (RA). Eight patients with clinically active synovitis were injected with 350 MBq 99mTc-IgG, and imaging took place 4 h later. This resulted in excellent images of inflamed synovium. Significant correlations were observed between individual joint uptake on the scan and scores for joint pain (n = 316, p less than 0.001), joint swelling (n = 300, p less than 0.001) or the average of pain and swelling (n = 300, p less than 0.001). These results suggest that 99mTc-IgG scintigraphy may provide an objective, non-invasive test to detect and measure synovitis.

Arthritis, Rheumatoid

Binding of 99mTc-labelled polyclonal human immunoglobulin to bacteria as a mechanism for scintigraphic detection of infection.

The aim of the present study was to determine whether 99mTc-labelled polyclonal human immunoglobulin (99mTc-HIG) binds to bacteria in vitro as well as in vivo. In vitro, the binding of 99mTc-HIG to various gram-positive and gram-negative bacteria was determined. In vivo, mice were infected with Staphylococcus aureus Cowan I (protein A rich) or S. aureus EMS (protein A deficient) in a thigh muscle and then 99mTc-HIG or 99mTc-labelled human serum albumin (99mTc-HSA) was administered; scintigrams were made 1, 4, and 18 h later. In vitro binding of 99mTc-HIG to bacteria was higher for gram-positive than for gram-negative forms. A positive correlation was found between the protein A content and the degree of binding to S. aureus. This was also found in vivo. The accumulation of 99mTc-HIG at the site of infection was significantly (P less than 0.01) higher than that of 99mTc-HSA, for both strains of S. aureus. It is concluded that vascular permeability cannot fully explain the accumulation of 99mTc-HIG at the site of infection and that binding of 99mTc-HIG to bacteria plays a role in this respect.

Animals

Effects of 5-hydroxytryptamine on capillary and arteriovenous anastomotic blood flow in the human hand and forearm and in the pig hind leg.

The effects of intraarterially infused serotonin (5-HT) on capillary and arteriovenous anastomotic (AVA) blood flow were investigated in the hand and forearm of 19 healthy volunteers, and in the hind leg of six anesthetized pigs using radioactive microspheres with a diameter of 15 microns. The 5-HT2-receptor antagonist ketan-serin was used in an attempt to identify the receptors involved. None of the drugs in the doses used induced systemic hemodynamic effects. Low doses of 5-HT significantly increased forearm blood flow with a maximum response at the dose of 1 ng/kg/min (68 +/- 14%, p less than 0.05), whereas only at the highest dose of 80 ng/kg/min was a net decrease in forearm blood flow measured (-28 +/- 6%, p less than 0.05). Conversely, finger blood flow was not influenced by the lower doses of 5-HT, whereas a major reduction was observed at the highest dose (-90 +/- 3%). Ketanserin increased both total forearm blood flow and AVA blood flow. The drug blunted the constrictor response to 5-HT in the forearm but only slightly attenuated this response in the finger. The percentage AVA blood flow in the human hand and forearm was not influenced by an infusion of 5-HT at 80 ng/kg/min alone. However, after pretreatment with ketanserin, which itself increased the AVA component, this dose of 5-HT significantly reduced AVA flow. In the pig, total femoral blood flow was not influenced by 5-HT, but AVA blood flow was significantly reduced and capillary skin blood flow increased.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

MR imaging and MIBG scintigraphy of pheochromocytomas and extraadrenal functioning paragangliomas.

To compare the potential of magnetic resonance (MR) imaging and scintigraphy performed with radiotracer-labeled metaiodobenzyl-guanidine (MIBG) in localization and characterization of functioning paragangliomas, the authors analyzed results of both modalities in 33 patients. Overall sensitivity for detection was 91% for MR imaging and 80% for MIBG scintigraphy. MR imaging demonstrated 100% of adrenal paragangliomas and 75% of extraadrenal paragangliomas, whereas MIBG scintigraphy revealed 75% and 88%, respectively. MIBG scintigraphy was more specific in the characterization of paragangliomas than MR imaging (100% vs 82%). However, MR imaging demonstrated nine other lesions not seen on scintigrams. On the basis of their results and other considerations, the authors believe MR imaging is the preferred initial technique when a functioning paraganglioma is suspected.

3-Iodobenzylguanidine

Detection of vertebral metastases: comparison between MR imaging and bone scintigraphy.

In a double-blind, prospective study, the authors analyzed bone scintigrams and magnetic resonance (MR) images of the spine in 71 patients with histologically proved skeletal metastases. Bone scintigrams and MR images were separately reviewed by four independent observers. Bone scintigraphy permitted identification of 499 abnormal vertebrae and MR imaging, 818 abnormal vertebrae. MR imaging depicted additional abnormal vertebrae in 49 patients. The authors conclude that MR imaging is more sensitive than bone scintigraphy in detection of vertebral metastases.

Adolescent

Detection of inflammatory lesions with radiolabelled immunoglobulins.

Previous reports on the use of radiolabelled immunoglobulins led us to undertake a pilot experiment in an animal model to investigate the potentials of Tc 99m-immunoglobulin scintigraphy in the detection of infectious foci. Mice infected in one leg with staphylococcus infection were injected with Tc 99m-immunoglobulin, Tc 99m-albumin or gallium citrate Ga 67. The results obtained by scintigraphy suggested a specific accumulation of radiolabelled immunoglobulin at the site of infection. Visualization of the infection and the image quality, especially the 6- and 24-h images, were clearly enhanced after the use of immunoglobulin preparations as compared with gallium.

Animals

Value of indium-111 tropolonate autologous granulocyte scintigraphy in the assessment of inflammatory bowel disease.

Indium-111 autologous leucocyte scanning is a non-invasive and reliable technique for the detection of abdominal abscesses. In the past decade several papers have been published concerning the use of this technique in the assessment of inflammatory bowel disease (IBD) with variable results. We conducted a prospective study of 62 patients with IBD attending the Leiden University Hospital, to assess the diagnostic value of indium-111 tropolonate autologous granulocyte scanning. Fifty-one patients had Crohn's disease (CD) (30 with involvement of the small bowel, 18 the colon only, and 3 patients had both localizations), and 11 had ulcerative colitis (UC). Twenty-one of 26 patients with evidence of active disease of the small intestine had a true-positive scan (sensitivity, 80%). However, accurate assessment of localization and extent of disease were often difficult. The other five patients had a false-negative scan. Seven patients had a true-negative scan. No false-positive scans were found. Thus, the diagnostic accuracy for small-intestinal Crohn's disease was 85%. In contrast, of 32 patients with colonic disease (CD and UC), 26 had a true-positive scan corresponding in localization and extent with standard investigations, 3 patients had a false-negative scan (sensitivity, 90%), and 3 had a true-negative scan (diagnostic accuracy, 91%). The patients' acceptability of this procedure was definitely superior to that for radiology and endoscopy. In conclusion, this technique has a definite place in evaluating localization and extent of active colonic disease and in severely ill patients in whom invasive techniques are contraindicated.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent

An antifibrin monoclonal antibody useful in immunoscintigraphic detection of thrombi.

Balb/c mice were immunized with human plasmin-generated fibrinogen degradation product Y. Spleen cells were fused with P3X63-Ag8.653 myeloma cells. A clone (Y22) was found that produces monoclonal antibodies (MoAbs) with a strong reactivity with human fibrin and only a weak reactivity with fibrinogen in an enzyme immunoassay (EIA). Y22 also reacts with fibrin of rabbits, rats, sheep, and dogs. The antibodies are of the IgG1 kappa-type and appear to be directed against a conformation-dependent epitope in the D-domain of fibrin. Experiments with 99mTc-labeled Y22 in vitro show that Y22 binds rapidly to forming clots. 99mTc-Y22 also binds to preformed plasma clots in a plasma milieu, even in the presence of high concentrations of heparin. Clot localization experiments in rabbits and rats confirm the high fibrin specificity and the potential of 99mTc-Y22 for thrombus imaging in vivo.

Abdomen

Image quality and radiopharmaceutical parameters of indium-111 granulocytes in scintigraphy of inflammatory bowel disease.

This study was undertaken to investigate the influence of various parameters of injected autologous 111In labelled granulocytes on scintigraphic image quality. Forty-two scintigrams of 37 patients with inflammatory bowel disease were evaluated. The images were divided into three groups according to quality: good, intermediate and poor. The relationships between image quality and such radiopharmaceutical parameters as injected dose of 111In, number of injected cells and specific activity were investigated. It appeared that in order to obtain interpretable images, a specific activity of at least 85 kBq 111In/million cells was necessary. The activity of the injected dose must exceed 7 MBq if poor quality images and very long acquisition times are to be avoided.

Cycloheptanes

The effects of diltiazem on cardiac function in silent ischemia after myocardial infarction.

In a total group of 56 patients with an acute myocardial infarction who were maximally exercised at predischarge, 20 patients (36%) showed greater than or equal to 1 mm asymptomatic ST-T segment depression during exercise. The site of the infarction was anterior in 12 patients and inferior in eight patients. All 20 patients underwent repeated exercise radionuclide angiography 2 days later, 2 hours following oral intake of 120 mg of diltiazem. Double product was not significantly different before and after diltiazem, both at rest and during exercise. Maximal ST-T depression after diltiazem was reduced from 2.3 +/- 0.8 to 0.7 +/- 0.6 mm (p less than 0.01). Left ventricular (LV) ejection fraction at rest before diltiazem was 54.4 +/- 8.7% and after diltiazem was 56.2 +/- 11.3% (p = NS). During exercise, LV ejection fraction improved after diltiazem from 43.2 +/- 12.2% to 49.8 +/- 10.5% (p less than 0.05). Regional wall motion score (1 = normal, 2 = hypokinetic, 3 = akinetic, 4 = dyskinetic) at rest before diltiazem was 9.6 +/- 2.0 and after diltiazem was 9.1 +/- 1.8 (p = NS). During exercise, regional wall motion score improved after diltiazem from 5.8 +/- 1.3 to 4.3 +/- 1.1 (p less than 0.02). We conclude that silent ischemia occurs in a substantial number of patients after myocardial infarction and that diltiazem has acute beneficial effects on asymptomatic ST-T depression and on global and regional LV function in post-infarction patients with silent ischemia.

Aged

Are activity indices helpful in assessing active intestinal inflammation in Crohn's disease?

We have investigated the correlation of 24 h and 48 h faecal Indium-111 excretion with each other and with several clinical activity indices for Crohn's disease (CD): Crohn's disease activity index (CDAI), activity index (AI), simple index (SI), Oxford score, and laboratory parameters, such as ESR, serum albumin, orosomucoid, C-reactive protein, alpha-l-antitrypsin (alpha 1-AT) faecal concentration, and alpha 1-AT clearance in 58 CD patients (37 with small bowel and 21 with colonic disease). A significant correlation was found between 24 and 48 h faecal Indium-111 excretion for small bowel (r = 0.708, p less than 0.0001) and colonic disease (r = 0.994, p less than 0.0001). The median faecal Indium-111 excretion for colonic involvement (4%; 0.15-50% median and range) was significantly (p less than 0.005) higher than that for small bowel disease (0.45%; 0.03-2.9%). No significant correlation was found between faecal Indium-111 excretion and any activity index in the patients with small bowel disease, while in the group of patients with colonic localisation only the AI showed a significant correlation (r = 0.593, p less than 0.02). Faecal Indium-111 excretion was significantly correlated with alpha 1-AT clearance (r = 0.712, p less than 0.0001) and faecal alpha 1-AT concentration (r = 0.750, p less than 0.0001) in small bowel and in colonic localisation (r = 0.530, p less than 0.02 and r = 0.444, p less than 0.05). Serum albumin was significantly correlated only in the group of patients with colonic disease (r = -0.593, p less than 0.05). The present study shows poor agreement between activity indices, serum parameters of activity and faecal Indium-111 excretion. As a good correlation was found with the alpha1-clearance, which reflects losses into the gut, these results may suggest that faecal Indium excretion does not only reflect activity of inflammation, but my relate to the extent of intestinal ulceration.

Adolescent

The acute effects of intravenous nisoldipine on left ventricular function 24 to 72 hours after uncomplicated acute myocardial infarction.

The acute effects on left ventricular function of nisoldipine were studied in six patients 56 +/- 12 hours (range 44 to 72 hours) after the onset of uncomplicated acute myocardial infarction. Nisoldipine was administered as a 4.5 micrograms/kg intravenous bolus over 3 minutes followed by an infusion of 0.2 microgram/kg during 60 minutes. Radionuclide angiography and two-dimensional echocardiography were performed before and during infusion with nisoldipine. The left ventricular ejection fraction increased significantly from 38% +/- 10% to 49% +/- 10% (P = 0.028) during nisoldipine infusion. Regional wall motion index was determined both by radionuclide and by two-dimensional echocardiography and showed a significant change during nisoldipine infusion from 1.9 +/- 0.3 to 1.5 +/- 0.3 (p = 0.028, radionuclide angiography) and from 0.7 +/- 0.2 to 0.3 +/- 0.2 (p = 0.043, two dimensional echocardiography). Heart rate increased significantly from 78 +/- 12 min-1 to 92 +/- 13 min-1 (p = 0.028), but mean double product did not change significantly during nisoldipine infusion. It is concluded that nisoldipine significantly improves global and regional left ventricular function in patients shortly after acute myocardial infarction. This beneficial effect may, however, be partially offset by an increase in heart rate. Since mean double product did not change, it is suggested that nisoldipine may improve coronary blood flow in patients with acute myocardial infarction.

Acute Disease

Is radiolabelled sucralphate scintigraphy of any use in the diagnosis of inflammatory bowel disease?

Previous optimistic reports led us to undertake a study to determine the value of 99Tcm-sucralphate scintigraphy in the assessment of localization and extent of active inflammatory bowel disease. Eight patients were studied; four had Crohn's disease (three small bowel and one colon localization) and four patients had ulcerative colitis. The results obtained by scintigraphy were compared with those obtained by diagnostic radiology and/or endoscopy. In five patients indium-111 granulocyte scintigraphy was also performed. 99Tcm-sucralphate scans showed total discrepancy with standard investigations in four patients and partial discrepancy in the other four. Furthermore, it was difficult from the images to decide whether the radiolabelled sucralphate indicated true inflammation or normal distribution of the radiopharmaceutical. Patient acceptability was very low due to frequent scanning times and the recommended purgation which was not well tolerated and is contraindicated in severely ill patients. We conclude that this technique is not a good screening test for diagnosing inflammatory bowel disease and we have, therefore, discontinued the study.

Adult

Value of indium-111 granulocyte scintigraphy in the assessment of Crohn's disease of the small intestine: prospective investigation.

The present study was undertaken to determine the value of indium-111 granulocyte scintigraphy in Crohn's disease of the small bowel by comparing the results with those of radiology, endoscopy and surgery. Twenty-one patients with Crohn's disease of the small bowel, 9 patients with Crohn's disease of the colon, 1 patient with both localizations and 8 with ulcerative colitis were studied by indium-111 granulocyte scanning. Eighteen patients had evidence of active small intestinal disease based on clinical, radiologic, and/or endoscopic, and/or histopathological features. Thirteen of them had a true positive scan (sensitivity 72%), but accurate assessment of localization and extent of disease was often difficult. Five patients had a false negative scan and 4 a true negative. No false positive scans were found. The diagnostic accuracy was 77%. In contrast, from 18 patients with colonic disease, 16 had a true positive scan corresponding in localization and extent with standard investigations, 1 patient had a false negative scan (sensitivity 94%), and 1 a true negative (diagnostic accuracy 95%). This study also showed that 3-5 h scanning after injection of indium-111-labeled granulocytes is the optimal timing for this test. The patient's acceptability of this procedure was definitely superior to radiology and endoscopy. In conclusion, this technique has a definite place in evaluating localization and extent of active colonic disease, but it does not replace good small bowel radiology and should not be recommended in the routine diagnostic workup of Crohn's disease of the small intestine.

Adolescent