Visualization of brainstem perfusion using a high spatial resolution SPECT system.

The authors explored the high spatial resolution of a three-head rotating SPECT system, equipped with lead super-fine fanbeam collimator. The brainstem was high-lighted in a three-dimensional reconstruction, showing perfusion small structures such as mesencephalon, pons, and medulla oblongata. The visualization of brainstem perfusion sets new landmarks in functional neuroimaging and, moreover, was obtained with a commercially available three-head SPECT system.

Brain Stem↗

Performance of a single crystal digital gamma camera for first pass cardiac studies.

First pass radionuclide angiocardiography (FPRNA) has gained increasing interest because of the development of new 99Tcm-labelled perfusion agents and of new 191Os/191Irm generator systems. The aim of the study was to evaluate the performance capacities of a small field of view single crystal digital gamma camera for 99Tcm and 191Irm at high count rates. The camera dead time for 99Tcm (window 30%) was well corrected up to 300 kcps in fast acquisition mode using the relative decrease of a small shielded reference source. Using the decaying activity method for 191Irm the non-linearity response of the gamma camera was corrected by an 191Os reference soruce up to 210 kcps at 70 keV, 75 kcps at 129 keV and 320 kcps including both peaks. Saturation count rates were respectively 270 kcps, 150 kcps and 420 kcps and high count rate resolution (FWHM) 9.0, 7.3 and 10.3 mm. Since the accuracy of first pass measurements is more sensitive to count rate than to spatial resolution the 50-150 keV window was chosen for clinical studies. In data obtained from 32 ECG gated FPRNA patient studies, the whole field of view count rate during the left ventricular phase ranged from 100 to 250 kcps with 80 to 120 mCi (2960-4400 MBq) of 191Irm and 100 to 180 kcps with 20 to 25 mCi (750-925 MBq) of 99Tcm red blood cells permitting for both tracers accurate non-linearity correction.

Evaluation Studies as Topic↗

Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

Aged↗

Evaluation of reproducibility of solid-phase gastric emptying in healthy subjects.

Radionuclide gastric emptying studies are performed as a matter of clinical routine. Our aim was to evaluate the inter- and intra-individual variability and the reproducibility of gastric emptying studies in healthy young male volunteers using a single solid-phase, standard meal. The meal consisted of a pancake (500 KJ) tagged with technetium 99m sulphur colloid and no additional liquid. Continuous acquisitions of gastric activity in anterior projection were taken during 90 min, starting from the onset of the meal. Gastric emptying was evaluated three times in a 3-week period. Five different parameters were evaluated. Our results show that there is important inter- and intra-individual variability in normal volunteers. In spite of this variability, no significant difference between the different series of gastric emptying studies was observed.

Adult↗

Effect of mild mental stress on solid phase gastric emptying in healthy subjects.

Radionuclide gastric emptying studies are performed in clinical routine but the possible influence of the mental state of the patient is never taken into account. We wanted to evaluate the effect of a mild psychological stress on solid phase gastric emptying in healthy young male volunteers. The standard meal consisted of a pancake (500 kJ) without additional liquid. Simultaneous dynamic acquisitions of gastric activity in anterior and posterior projection were taken during 90 min starting from the onset of the meal. Gastric emptying was evaluated three times in basal conditions and once under mental stress. Stress was induced by means of a dichotomous listening test, lasting for 30 min, starting at the end of the meal. The results of rest and stress studies were compared. Mild mental stress has a significant influence on gastric emptying. The lag phase increased from 11 +/- 3 min to 36 +/- 10 min (mean +/- S.D.) (p less than 0.005) and the gastric emptying rate from 79 +/- 13%/hour to 100 +/- 31%/hour (mean +/- S.D.) (not significant). During a stress period gastric emptying as a whole is delayed but this is mainly due to the prolongation of the lag phase. Our data also suggest that during the stress period gastric emptying is interrupted and reactivated once the stress period has ended.

Adult↗

A porcelain gallbladder affecting the assessment of bone mineral content.

Dual-photon absorptiometry is a reliable method for the assessment of bone mineral content (BMC). The presence of focal bone disease, degenerative joint disease, or aortic calcifications may complicate the evaluation of BMC and may lead to erroneous findings. The misleading effect of a porcelain gallbladder is described.

Absorptiometry, Photon↗

Continuous anterior acquisitions in gastric emptying: comparison with the mean.

Depth correction is necessary when gastric emptying is studied by means of a labeled meal. In this study continuous anterior images were acquired from the onset of the food ingestion. Differences in depth were measured using a left lateral view. A minimal and crude depth correction was performed. The results obtained with this correction method were compared with those obtained using the depth correction technique of the mean. The results obtained in the anterior projection without any depth correction were also compared with those obtained using the method of the mean. The results obtained with both correction techniques were identical in 18 gastric emptying studies. This approach also permits the creation of a time-activity curve over the duodenum in the anterior projection. In this way the lag phase can easily be assessed.

Adult↗

Clinical usefulness of ultrashort-lived iridium-191m from a carbon-based generator system for the evaluation of the left ventricular function.

Ultrashort-lived 191mIr (4.96 sec; 63-74 and 129 keV photons) is potentially advantageous for first-pass radionuclide angiocardiography, offering the opportunity to perform repeat studies with very low absorbed radiation dose to the patient. Left ventricular (LV) first-pass studies were performed in 72 patients with 191mIr from a new bedside 1.3 Ci (48.1 GBq) 191Os/191mIr generator system using an activated carbon support that offers high 191mIr yields (15-18%) and consistent low 191Os breakthrough (2-4 x 10(-4)%/bolus). Using a single crystal digital gamma camera, uncorrected end-diastolic counts in the left ventricular representative cycle ranged from 10 up to 30 k counts. The reproducibility of repeated LV ejection fraction (LVEF) determination at 2-min intervals in 50 patients was r = 0.97, mean diff. = 2.08 +/- 1.55 EF units. Comparison between 191mIr (80-120 mCi; 2,960-4,400 MBq) and 99mTc (20-25 mCi; 750-925 MBq) LV count rates indicates a 3 wk useful shelf life of this new generator system for cardiac studies. Iridium-191m determined LVEF correlated closely with 99mTc determined LVEF in 32 patients (r = 0.96, mean diff. = 1.87 +/- 1.23 EF units). Parametric images for LV wall motion analysis were comparable with both isotopes. We conclude that rapid, repeat, and reproducible high count rate first-pass left ventricular studies can be obtained with 191mIr from this new 191Os/191mIr generator system using a single crystal digital gamma camera.

Adult↗

Assessment of vertebral mineral content by means of a single-crystal scintillation camera.

Increasing interest in bone mass has led to dedicated commercial dual photon absorptiometry (DPA) instruments. We describe a method for the measurement of the mineral content of the lumbar spine using a scintillation camera. The most appropriate source(s) and collimator were investigated. An especially constructed arm placed the sources in the focal point of a converging collimator. Two single-peak sources, 99Tcm and 241Am, were used instead of dual-peak 153Gd source. Phantom studies showed no degradation of the results in water depths of up to 26 cm. Acquiring 10 Mcounts per image over a 300 cm2 field, a coefficient of variation (c.v.) of 1.7% was obtained. Reducing the total counts per image to 1 Mcount gave rise to a c.v. of 6.2%. Long-term measurements showed a c.v. of 1.1% for density, with a mean value of 0.98 gHa cm-2 compared to 0.90 for a commercial DPA instrument. Repeated measurements of the lumbar spine on 10 patients with a 2 week interval showed a c.v. of 5%. Comparative measurements were made between the scintillation camera and a commercial DPA instrument on six volunteers. Systematic higher results, similar to those observed with the phantom, were obtained with the scintillation camera. The reproducibility on a phantom and in patients is in the same range as commercial DPA instruments. The low cost related to the use of standard nuclear medicine equipment and to inexpensive radioactive sources represent definite advantages.

Humans↗

Hemodynamic effects of nebivolol in men: comparison of radionuclide angiocardiography with systolic time intervals.

In a subacute experiment the authors studied the effects of a fourteen -day treatment with nebivolol, 5 mg once a day, in 10 healthy male volunteers with a mean age of thirty-one, twenty-five to thirty-nine years, by comparing the results of the resting ratio of the preejection period (PEP) to the left ventricular ejection time (LVET), as measured by systolic time intervals (STI), with the results obtained by equilibrium radionuclide angiocardiography (ERNA), using technetium 99m-labeled autologous red blood cells as a marker. A submaximal treadmill exercise test performed before and during treatment demonstrated that nebivolol significantly (p less than 0.01) reduced peak exercise heart rate and systolic blood pressure from a mean value of 158 +/- 5.4 bpm to 131 +/- 4.3 bpm and from 171 +/- 4.9 mmHg to 144 +/- 4.5 mmHg respectively. The data from the STI and ERNA were calculated and analyzed independently by two observers. A highly significant (r = 0.8182, p = 0.0038) correlation was found between the changes of stroke volume (SV) and PEPc/LVETc during treatment with nebivolol. Furthermore end-diastolic volume significantly(p = 0.03) increased from a mean value of 177 +/- 10.1 ml to 198 +/- 6 ml and stroke volume significantly (p = 0.01) increased from 120 +/- 6.8 ml to 136 +/- 6.3 ml. Systemic vascular resistance tended to decrease from a mean value of 11.4 +/- 1.28 units to 10.6 +/- 1.10 units. No changes could be observed either in ejection fraction or in cardiac output.(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Antagonists↗

Ventilation-perfusion patterns in lung diseases (with reference to those observed in pulmonary embolism).

The frequency distributions of ventilation-perfusion (V-P) patterns in various lung diseases were compared to those observed in pulmonary embolism in order to determine whether the specific V-P patterns for pulmonary embolism constituted a frequent finding in these disorders. The results showed that a segmental or lobar perfusion defect with normal ventilation, was associated with a high probability of thromboembolic lung disease, and was not present in any of the other lung diseases studied.

Humans↗

Amplitude distribution in the right ventricle.

Amplitude distribution in the right ventricle obtained from ECG-gated ventriculography has been reviewed and six amplitude distribution patterns were identified. Homogeneous distribution was rarely observed even in patients without any cardiac or pulmonary diseases. Furthermore, there was no difference in frequency distribution of the amplitude distribution patterns between the control group, patients with coronary diseases, and those with recent inferior myocardial infarction. It was concluded that amplitude distribution could not be used to detect hypokinetic areas in the right ventricle.

Angina Pectoris↗

Effect of fenoterol on small airways and regional lung function in asymptomatic asthma.

Lung function tests for small airways were performed before and after inhalation of fenoterol by 11 young asymptomatic asthmatics and in 8 control subjects. In the asthmatics, minimal impairment in the tests was found except for increased expansion of the lower part of the lung (133Xe regional lung volumes) and an "abnormal" distribution pattern of a bolus of Xe inhaled from the residual volume. This suggests enhanced airway closure, especially in the lower area of the lung. Usual therapeutic doses of fenoterol (0.4 to 0.6 mg in puffs) could not correct these abnormalities, but 1.2 mg given to 2 patients resulted in changes similar to those observed in normals. The results suggest that small airway impairment in asymptomatic asthmatics is not only related to enhanced bronchomotor tone, but also to anatomical changes located especially at the base of the lung.

Adult↗

The evaluation of right ventricular performance using krypton-81m.

The availability of krypton-81m suitable for intravenous injection provides an easy means for assessing right ventricular function. The superimposition of the other heart chambers does not constitute a problem. The activity in the left heart is negligible and the study can be performed in the right anterior oblique position to obtain optimal separation between the right atrium and the right ventricle. Lung activity is quite high and should be corrected before computing the right ventricular ejection fraction. This correction can be accomplished by performing Tc-99m MAA perfusion scintigraphy. The measurement of the right ventricular ejection fraction appears to be reproducible with very small inter-and intraobserver variability. Good quality phase and amplitude images can be obtained with such high count rates.

Cardiac Output↗