Fusion of respiration-correlated PET and CT scans: correlated lung tumour motion in anatomical and functional scans.

Lower lobe lung tumours in particular can move up to 2 cm in the cranio-caudal direction during the respiration cycle. This breathing motion causes image artefacts in conventional free-breathing computed tomography (CT) and positron emission tomography (PET) scanning, rendering delineation of structures for radiotherapy inaccurate. The purpose of this study was to develop a method for four-dimensional (4D) respiration-correlated (RC) acquisition of both CT and PET scans and to develop a framework to fuse these modalities. The breathing signal was acquired using a thermometer in the breathing airflow of the patient. Using this breathing signal, the acquired CT and PET data were grouped to the corresponding respiratory phases, thereby obtaining 4D CT and PET scans. Tumour motion curves were assessed in both image modalities. From these tumour motion curves, the deviation with respect to the mean tumour position was calculated for each phase. The absolute position of the centre of the tumour, relative to the bony anatomy, in the RCCT and gated PET scans was determined. This 4D acquisition and 4D fusion methodology was performed for five patients with lower lobe tumours. The peak-to-peak amplitude range in this sample group was 1-2 cm. The 3D tumour motion curve differed less than 1 mm between PET and CT for all phases. The mean difference in amplitude was less than 1 mm. The position of the centre of the tumour (relative to the bony anatomy) in the RCCT and gated PET scan was similar (difference <1 mm) when no atelectasis was present. Based on these results, we conclude that the method described in this study allows for accurate quantification of tumour motion in CT and PET scans and yields accurate respiration-correlated 4D anatomical and functional information on the tumour region.

Algorithms↗

Field size reduction enables iso-NTCP escalation of tumor control probability for irradiation of lung tumors.

PURPOSE: With the mean lung dose (MLD) as an estimator for the normal tissue complication probability (NTCP) of the lung, we assessed whether the probability of tumor control of lung tumors might be increased by dose escalation in combination with a reduction of field sizes, thus increasing target dose inhomogeneity while maintaining a constant MLD. METHODS AND MATERIALS: An 8-MV AP-PA irradiation of a lung tumor, located in a cylindrically symmetric lung-equivalent phantom, was modeled using numerical simulation. Movement of the clinical target volume (CTV) due to patient breathing and setup errors was simulated. The probability of tumor control, expressed as the equivalent uniform dose (EUD) of the CTV, was assessed as a function of field size, under the constraint of a constant MLD. The approach was tested for a treatment of a non-small cell lung cancer (NSCLC) patient using the beam directions of the clinically applied treatment plan. RESULTS: In the phantom simulation it was shown that by choosing field sizes that ensured a minimum dose of 95% in the CTV ("conventional" plan) taking into account setup errors and tumor motion, an EUD of the CTV of 43.8 Gy can be obtained for a prescribed dose of 44.2 Gy. By reducing the field size and thus shifting the 95% isodose surface inwards, the EUD increases to a maximum of 68.3 Gy with a minimum dose in the CTV of 55.2 Gy. This increase in EUD is caused by the fact that field size reduction enables escalation of the prescribed dose while maintaining a constant MLD. Further reduction of the field size results in decrease of the EUD because the minimum dose in the CTV becomes so low that it has a predominant effect on the EUD, despite further escalation of the prescribed dose. For the NSCLC patient, the EUD could be increased from an initial 62.2 Gy for the conventional plan, to 83.2 Gy at maximum. In this maximum, the prescribed dose is 88.1 Gy, and the minimum dose in the CTV is 67.4 Gy. In this case, the 95% isodose surface is conformed closely to the "static" CTV during treatment planning. CONCLUSIONS: Iso-NTCP escalation of the probability of tumor control is possible for lung tumors by reducing field sizes and allowing a larger dose inhomogeneity in the CTV. Optimum field sizes can be derived, having the highest EUD and highest minimum dose in the CTV under condition of a constant NTCP of the lungs. We conclude that the concept of homogeneous dose in the target volume is not the best approach to reach the highest probability of tumor control for lung tumors.

Humans↗

Planning, computer optimization, and dosimetric verification of a segmented irradiation technique for prostate cancer.

PURPOSE: To develop and verify a multisegment technique for prostate irradiation that results in better sparing of the rectal wall compared to a conventional three-field technique, for patients with a concave-shaped planning target volume (PTV) overlapping the rectal wall. METHODS AND MATERIALS: Five patients have been selected with various degrees of overlap between PTV and rectal wall. The planned dose to the ICRU reference point is 78 Gy. The new technique consists of five beams, each having an open segment covering the entire PTV and several smaller segments in which the rectum is shielded. Segment weights are computer-optimized using an algorithm based on simulated annealing. The score function to be minimized consists of dose-volume constraints for PTV, rectal wall, and femoral heads. The resulting dose distribution is verified for each patient by using point measurements and line scans made with an ionization chamber in a water tank and by using film in a cylindrical polystyrene phantom. RESULTS: The final number of segments in the five-field technique ranges from 7 to 9 after optimization. Compared to the standard three-field technique, the maximum dose to the rectal wall decreases by approximately 3 Gy for patients with a large overlap and 1 Gy for patients with no overlap, resulting in a reduction of the normal tissue complication probability (NTCP) by a factor of 1.3 and 1.2, respectively. The mean dose to the PTV is the same for the two techniques, but the dose distribution is slightly less homogeneous with the five-field technique (Average standard deviation of five patients is 1.1 Gy and 1.7 Gy for the three-field and five-field technique, respectively). Ionization chamber measurements show that in the PTV, the calculated dose is in general within 1% of the measured dose. Outside the PTV, systematic dose deviations of up to 3% exist. Film measurements show that for the complete treatment, the position of the isodose lines in sagittal and coronal planes is calculated fairly accurately, the maximum distance between measured and calculated isodoses being 4 mm. CONCLUSIONS: We developed a relatively simple multisegment "step-and-shoot" technique that can be delivered within an acceptable time frame at the treatment machine (Extra time needed is approximately 3 minutes). The technique results in better sparing of the rectal wall compared to the conventional three-field technique. The technique can be planned and optimized relatively easily using automated procedures and a predefined score function. Dose calculation is accurate and can be verified for each patient individually.

Algorithms↗

Set-up verification using portal imaging; review of current clinical practice.

In this review of current clinical practice of set-up error verification by means of portal imaging, we firstly define the various types of set-up errors using a consistent nomenclature. The different causes of set-up errors are then summarized. Next, the results of a large number of studies regarding patient set-up verification are presented for treatments of patients with head and neck, prostate, pelvis, lung and breast cancer, as well as for mantle field/total body treatments. This review focuses on the more recent studies in order to assess the criteria for good clinical practice in patient positioning. The reported set-up accuracy varies widely, depending on the treatment site, method of immobilization and institution. The standard deviation (1 SD, mm) of the systematic and random errors for currently applied treatment techniques, separately measured along the three principle axes, ranges from 1.6-4.6 and 1.1-2.5 (head and neck), 1.0-3.8 and 1.2-3.5 (prostate), 1.1-4.7 and 1.1-4.9 (pelvis), 1.8-5.1 and 2.2-5.4 (lung), and 1.0-4.7 and 1.7-14.4 (breast), respectively. Recommendations for procedures to quantify, report and reduce patient set-up errors are given based on the studies described in this review. Using these recommendations, the systematic and random set-up errors that can be achieved in routine clinical practice can be less than 2.0 mm (1 SD) for head and neck, 2.5 mm (1 SD) for prostate, 3.0 mm (1 SD) for general pelvic and 3.5 mm (1 SD) for lung cancer treatment techniques.

Breast Neoplasms↗

Partial irradiation of the lung.

Many factors like fractionation, overall treatment time, and patient specific aspects are important when studying and quantifying the effects of partial lung irradiation. The local reactions of lung tissue to irradiation are described with regard to the dose-volume effect. Different models that are used to predict the incidence of radiation pneumonitis and the influence of irradiation on the overall lung function are discussed. The easy-to-calculate mean lung dose (MLD) and the volume irradiated to 20 Gy (V20) can both be used to predict the incidence of radiation pneumonitis. These parameters represent 2 extremes in underlying local dose-effect relations for radiation pneumonitis. However, clinically applied treatment plans show a high correlation between the V20 and the MLD, so that the decision for the "best" underlying local dose-effect relation should be based on the analysis of additional patient data. Dose-escalation studies and multi-center co-operation will create more possibilities to investigate all confounding factors concerning lung irradiation.

Dose-Response Relationship, Radiation↗

Changes in local pulmonary injury up to 48 months after irradiation for lymphoma and breast cancer.

PURPOSE: To assess the recovery from early local pulmonary injury after irradiation and to determine whether regional differences exist. METHODS: For 110 patients treated for breast cancer or malignant lymphoma, single photon emission computed tomography (SPECT) perfusion and ventilation scans and CT scans were made before, 3, 18, and 48 months after radiotherapy. Dose-effect relations for changes in local perfusion, ventilation, and density were determined for each individual patient using spatially correlated SPECT and CT data sets, for each follow-up period. Average dose-effect relations for both subgroups were determined, as well as dose-effect relations for different regions. RESULTS: In general, partial improvement of local pulmonary injury was observed between 3 and 18 months for each of the three endpoints. After 18 months, no further improvement was seen. Patients with breast cancer and malignant lymphoma showed a similar improvement (except for the perfusion parameter), which was attributed to a recovery from the early radiation response and could not be explained by contraction effects of fibrosis of lung parenchyma. No regional differences in radiosensitivity 18 months after treatment were observed, except for the dorsal versus ventral region. This difference was attributed to a gravity-related effect in the measuring procedure. CONCLUSION: For all patients, a partial recovery from early local perfusion, ventilation, and density changes, was seen between 3 and 18 months after radiotherapy. After 18 months, local lung function did not further improve (lymphoma patients).

Adolescent↗

The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy.

PURPOSE: To provide an analytical description of the effect of random and systematic geometrical deviations on the target dose in radiotherapy and to derive margin rules. METHODS AND MATERIALS: The cumulative dose distribution delivered to the clinical target volume (CTV) is expressed analytically. Geometrical deviations are separated into treatment execution (random) and treatment preparation (systematic) variations. The analysis relates each possible preparation (systematic) error to the dose distribution over the CTV and allows computation of the probability distribution of, for instance, the minimum dose delivered to the CTV. RESULTS: The probability distributions of the cumulative dose over a population of patients are called dose-population histograms in short. Large execution (random) variations lead to CTV underdosage for a large number of patients, while the same level of preparation (systematic) errors leads to a much larger underdosage for some of the patients. A single point on the histogram gives a simple "margin recipe." For example, to ensure a minimum dose to the CTV of 95% for 90% of the patients, a margin between CTV and planning target volume (PTV) is required of 2.5 times the total standard deviation (SD) of preparation (systematic) errors (Sigma) plus 1.64 times the total SD of execution (random) errors (sigma') combined with the penumbra width, minus 1.64 times the SD describing the penumbra width (sigma(p)). For a sigma(p) of 3.2 mm, this recipe can be simplified to 2.5 Sigma + 0.7 sigma'. Because this margin excludes rotational errors and shape deviations, it must be considered as a lower limit for safe radiotherapy. CONCLUSION: Dose-population histograms provide insight into the effects of geometrical deviations on a population of patients. Using a dose-probability based approach, simple algorithms for choosing margins were derived.

Algorithms↗

Radiation dose-effect relations and local recovery in perfusion for patients with non-small-cell lung cancer.

PURPOSE: To determine local dose-effect relations for lung perfusion and density changes due to irradiation for patients with non-small-cell lung cancer (NSCLC) and to quantify the effect of reperfusion. METHODS AND MATERIALS: For 25 NSCLC patients and a reference group of 81 patients with healthy lungs, registered single photon emission computed tomography (SPECT) lung perfusion and CT scans were made, before and after radiotherapy. Average dose-effect relations for perfusion and CT-density changes were calculated and compared with the dose-effect relation of the reference group. On the basis of these dose-effect relations, the post-RT perfusion was predicted for each patient and compared to the measured post-RT perfusion. RESULTS: Well-perfused lung regions of the NSCLC patients showed the same dose-effect relation as the reference patients. By comparing predicted and measured post-treatment perfusion scans, regions of reperfusion could be determined for 18 of 25 NSCLC patients but for none of the reference patients. CONCLUSION: Well-perfused lung tissue of patients with NSCLC behaves like healthy lung tissue with respect to radiation. The dose-effect relation for perfusion and CT density was extended for doses up to 80 Gy. Radiation damage in poorly perfused lung regions was less than predicted as a consequence of local reperfusion.

Algorithms↗

Primary axillary radiotherapy as axillary treatment in breast-conserving therapy for patients with breast carcinoma and clinically negative axillary lymph nodes.

BACKGROUND: The objective of the current study was to evaluate the effectiveness and morbidity of primary axillary radiotherapy in breast-conserving therapy for postmenopausal, clinically axillary lymph node negative patients with early stage breast carcinoma. METHODS: Between 1983-1997, 105 patients with clinically negative axillary lymph nodes and breast carcinoma were treated with wide local excision followed by radiotherapy to the breast, and axillary and supraclavicular lymph node areas. Adjuvant treatment with tamoxifen was given to 75 patients. The median follow-up of patients still alive was 41 months (range, 8-137 months). Fifty-five patients with no evidence of disease at last follow-up were examined prospectively with respect to late functional damage. RESULTS: The mean age of the patients was 64 years. Three patients developed a local recurrence. No isolated axillary lymph node recurrence was observed. In two patients, axillary recurrence was accompanied by distant metastases. The 5-year disease free interval and the overall survival were 82% (standard error [SE], 6%) and 83% (SE, 6%), respectively. In five patients, arm edema was reported and impaired shoulder function was reported in seven patients. Prospectively scored, arm edema was reported subjectively by the patient in 4% and objectively measured in 11% of cases. Impaired shoulder function was reported subjectively in 35% and objectively measured in 17% of cases. No brachial plexus neuropathy was noted. CONCLUSIONS: Primary axillary radiotherapy for postmenopausal women with clinically lymph node negative, early stage breast carcinoma was found to result in low axillary lymph node recurrence rates with only limited late complications. Therefore, primary axillary radiotherapy should be considered as axillary treatment in selected patients as an alternative to axillary lymph node dissection.

Aged↗

3-D portal image analysis in clinical practice: an evaluation of 2-D and 3-D analysis techniques as applied to 30 prostate cancer patients.

PURPOSE: To investigate the clinical importance and feasibility of a 3-D portal image analysis method in comparison with a standard 2-D portal image analysis method for pelvic irradiation techniques. METHODS AND MATERIALS: In this study, images of 30 patients who were treated for prostate cancer were used. A total of 837 imaged fields were analyzed by a single technologist, using automatic 2-D and 3-D techniques independently. Standard deviations (SDs) of the random, systematic, and overall variations, and the overall mean were calculated for the resulting data sets (2-D and 3-D), in the three principal directions (left-right [L-R], cranial-caudal [C-C], anterior-posterior [A-P]). The 3-D analysis included rotations as well. For the translational differences between the three data sets, the overall SD and overall mean were computed. The influence of out-of-plane rotations on the 2-D registration accuracy was determined by analyzing the difference between the 2-D and 3-D translation data as function of rotations. To assess the reliability of the 2-D and 3-D methods, the number of times the automatic match was manually adjusted was counted. Finally, an estimate of the workload was made. RESULTS: The SDs of the random and systematic components of the rotations around the three orthogonal axes were 1. 1 (L-R), 0.6 (C-C), 0.5 (A-P) and 0.9 (L-R), 0.6 (C-C), 0.8 (A-P) degrees, respectively. The overall mean rotation around the L-R axis was 0.7 degrees, which deviated significantly from zero. Translational setup errors were comparable for 2-D and 3-D analysis (ranging from 1.4 to 2.2 mm SD and from 1.5 to 2.5 mm SD, respectively). The variation of the difference between the 2-D and 3-D translation data increased from 1.1 mm (SD) for zero rotations to 2.7 mm (SD) for out-of-plane rotations of 3 degrees, due to a reduced 2-D registration accuracy for large rotations. The number of times the analysis was not considered acceptable and was manually adjusted was 44% for the 2-D analysis, and 6% for the 3-D analysis. CONCLUSION: True 3-D analysis of setup errors for a group of 30 patients with prostate cancer demonstrated that setup rotations are rather small. The deformation of the projected anatomy in portal images caused by out-of-plane rotations leads to a reduced 2-D registration accuracy. For rotations larger than 3 degrees this effect can be quite pronounced, making 3-D registration the preferred method. Furthermore, the automatic 3-D registration has a higher success rate, most likely because this technique uses more information compared to the 2-D method.

Feasibility Studies↗

A treatment planning method to correct dose distributions distorted by setup verification fields.

PURPOSE: Portal images of conformal treatment fields are often not suitable for setup verification purposes because they contain insufficient bony structures. Therefore, additional rectangular fields are frequently applied for setup verification purposes. It is the aim of this study to reduce the dose distortions induced by these extra fields by appropriately adjusting the beam weights and wedge angles of the treatment fields. METHODS AND MATERIALS: A second treatment plan for the setup verification session is generated, with an identical beam setup as the original plan, but which also includes two orthogonal setup verification fields. An algorithm has been developed, based on vector analysis methods, that adjusts the beam weights and wedge angles of the treatment fields in such a way that both the dose at the isocenter and the dose homogeneity over the planning target volume (PTV) are conserved. RESULTS: The algorithm has been applied to three clinical cases. The number of MUs for the setup verification fields, using a liquid-filled electronic portal imaging device, varied between 16 MU in the head and neck region up to 34 MU for lateral images in the pelvic region. In all cases, the method yielded a treatment plan including two orthogonal setup verification fields with a similar dose distribution over the PTV as the original treatment plan without the setup verification fields. CONCLUSION: The dose distortions resulting from the acquisition of orthogonal verification imaging can be neutralized by modifying the original beam weights and wedge angles of the treatment fields.

Algorithms↗

Cardiac and lung complication probabilities after breast cancer irradiation.

PURPOSE: To assess for locoregional irradiation of breast cancer patients, the dependence of cardiac (cardiac mortality) and lung (radiation pneumonitis) complications on treatment technique and individual patient anatomy. MATERIALS AND METHODS: Three-dimensional treatment planning was performed for 30 patients with left-sided breast cancer and various breast sizes. Two locoregional techniques (Techniques A and B) and a tangential field technique, including only the breast in the target volume, were planned and evaluated for each patient. In both locoregional techniques tangential photon fields were used to irradiate the breast. The internal mammary (IM)-medial supraclavicular (MS) lymph nodes were treated with an anterior mixed electron/photon field (Technique A) or with an obliquely incident mixed electron/photon IM field and an anterior electron/photon MS field (Technique B). The optimal IM and MS electron field dimensions and energies were chosen on the basis of the IM-MS lymph node target volume as delineated on CT-slices. The position of the tangential fields was adapted to match the IM-MS fields. Dose-volume histograms (DVHs) and normal tissue complication probabilities (NTCPs) for the heart and lung were compared for the three techniques. In the beam's eye view of the medial tangential fields the maximum distance of the heart contour to the posterior field border was measured; this value was scored as the Maximum Heart Distance. RESULTS: The lymph node target volume receiving more than 85% of the prescribed dose was on average 99% for both locoregional irradiation techniques. The breast PTV receiving more than 95% of the prescribed dose was generally smaller using Technique A (mean: 90%, range: 69-99%) than using Technique B (mean: 98%, range: 82-100%) or for the tangential field technique (mean: 98%, range: 91-100%). NTCP values for excess cardiac mortality due to acute myocardial ischemia varied considerably between patients, with minimum and maximum values of 0.1 and 7.5% (Technique A), 0.1 and 5.8% (Technique B) and 0.0 and 6.1% (tangential tech.). The NTCP values were on average significantly higher (P<0.001) by 1.7% (Technique A) and 1.0% (Technique B) when locoregional breast irradiation was given, compared with irradiation of the left breast only. The NTCP values for the tangential field technique could be estimated using the Maximum Heart Distance. NTCP values for radiation pneumonitis were very low for all techniques; between 0.0 and 1.0%. CONCLUSIONS: Technique B results in a good coverage of the breast and locoregional lymph nodes, while Technique A sometimes results in an underdosage of part of the target volume. Both techniques result in a higher probability of heart complications compared with tangential irradiation of the breast only. Irradiation toxicity for the lung is low in all techniques. The Maximum Heart Distance is a simple and useful parameter to estimate the NTCP values for cardiac mortality for tangential breast irradiation.

Breast Neoplasms↗

Dose-wall histograms and normalized dose-surface histograms for the rectum: a new method to analyze the dose distribution over the rectum in conformal radiotherapy.

PURPOSE: To develop an accurate method to generate a dose-volume histogram (DVH) of the rectum wall, solely based on the outer contours of the rectum wall. METHODS AND MATERIALS: A mathematical model for the rectum wall is developed, incorporating the stretching of the rectum wall due to variable rectal filling and neighboring structures. The model is based on the assumption that the amount of intersected rectum wall tissue normal to the central axis of the rectum is constant. The main objective of the model is to determine the thickness of the rectum wall in each wall element. Two approaches are described, each yielding a DVH of the rectum wall, based only on the delineated outer contours of the rectum. In the first approach, the model is used to create a set of inner contours out of the axial outer contours. Both sets of contours are used to derive a dose-wall histogram (DWH) of the rectum. In the second approach, the model is used to generate a normalized 2D sampling space, which is subsequently binned into a normalized dose-surface histogram (NDSH). The model is verified using 20 sets of CT data (5 patients x 4 scans) in which both outer and inner contours of the rectum are carefully delineated. The DWHs and NDSHs are compared with DVHs of the rectum wall, which require contouring of the outer and inner surfaces of the rectum wall, and with DVHs of the total rectum (including rectal filling). The variation between DWHs, NDSHs, and DVHs is investigated using normal tissue complication probability (NTCP) calculations. RESULTS: The local wall thickness of the rectum as outlined on CT data was in conformity with the described rectum model. The amount of rectum wall tissue per unit length rectum varied considerably between patients (27%, 1 SD). In all analyzed patients, the DWHs and NDSHs corresponded well to the DVHs of the rectum wall. Much more discrepancies were observed between the DVHs of the total rectum and the DVHs of the rectum wall. CONCLUSION: The applied methods yield accurate dose distributions of the rectum wall, without delineating the inner surface of the rectum. This reduces both the workload and variations due to inaccurate delineation of the rectum wall. The DWH and NDSH are effective tools to evaluate 3D dose distributions of the rectum wall and to estimate the complication probability of the rectum in high-dose conformal radiotherapy.

Humans↗

Comparison of prostate cancer treatment in two institutions: a quality control study.

PURPOSE: To minimize differences in the treatment planning procedure between two institutions within the context of a radiotherapy prostate cancer trial. PATIENTS AND METHODS: Twenty-two patients with N0 M0 prostate cancer underwent a computed tomography (CT) scan for radiotherapy treatment planning. For all patients, the tumor and organs at risk were delineated, and a treatment plan was generated for a three-field technique giving a dose of 78 Gy to the target volume. Ten of the 22 cases were delineated and planned in the other institution as well. The delineated volumes and dose distributions were compared. RESULTS: All treatments fulfilled the trial criteria. The mean volume ratio of the gross tumor volumes (GTVs) in both institutions was 1.01, while the mean volume ratio of the planning target volumes (PTVs) was 0.88. The three-dimensional (3D) PTV difference was 3 mm at the prostate apex and 6-8 mm at the seminal vesicles. This PTV difference was mainly caused by a difference in the method of 3D expansion, and disappeared when applying an improved algorithm in one institution. The treated volume (dose > or =95% of isocenter dose) reflects the size of the PTV and the conformity of the treatment technique. This volume was on average 66 cm3 smaller in institution A than in institution B; the effect of the PTV difference was 31 cm3 and the difference in technique accounted for 36 cm3. The mean delineated rectal volume including filling was 112 cm3 and 125 cm3 for institution A and B, respectively. This difference had a significant impact on the relative dose volume histogram (DVH) of the rectum. CONCLUSION: Differences in GTV delineation were small and comparable to earlier quantified differences between observers in one institution. Different expansion methods for generation of the PTV significantly influenced the amount of irradiated tissue. Strict definitions of target and normal structures are mandatory for reliable trial results.

Humans↗

Beam intensity modulation to reduce the field sizes for conformal irradiation of lung tumors: a dosimetric study.

PURPOSE: In conformal radiotherapy of lung tumors, penumbra broadening in lung tissue necessitates the use of larger field sizes to achieve the same target coverage as in a homogeneous environment. In an idealized model configuration, some fundamental aspects of field size reduction were investigated, both for the static situation and for a moving tumor, while maintaining the dose homogeneity in the target volume by employing a simple beam-intensity modulation technique. METHODS AND MATERIALS: An inhomogeneous phantom, consisting of polystyrene, cork, and polystyrene layers, with a 6 x 6 x 6 cm3 polystyrene cube inside the cork representing the tumor, was used to simulate a lung cancer treatment. Film dosimetry experiments were performed for an AP-PA irradiation technique with 8-MV or 18-MV beams. Dose distributions were compared for large square fields, small square fields, and intensity-modulated fields in which additional segments increase the dose at the edge of the field. The effect of target motion was studied by measuring the dose distribution for the solid cube, displaced with respect to the beams. RESULTS: For the 18-MV beam, the field sizes required to establish a sufficient target coverage are larger than for the 8-MV beam. For each beam energy, the mean dose in cork can significantly be reduced (at least a factor of 1.6) by decreasing the field size with 2 cm, while keeping the mean target dose constant. Target dose inhomogeneity for these smaller fields is limited if the additional edge segments are applied for 8% of the number of monitor units given with the open fields. The target dose distribution averaged over a motion cycle is hardly affected if the target edge does not approach the field edge to within 3 mm. CONCLUSIONS: For lung cancer treatment, a beam energy of 8 MV is more suitable than 18 MV. The mean lung dose can be significantly reduced by decreasing the field sizes of conformal fields. The smaller fields result in the same biological effect to the tumor if the mean target dose is kept constant. Intensity modulation can be employed to maintain the same target dose homogeneity for these smaller fields. As long as the target (with a 3 mm margin) stays within the field portal, application of a margin for target motion is not necessary.

Film Dosimetry↗

Definition of the prostate in CT and MRI: a multi-observer study.

PURPOSE: To determine, in three-dimensions, the difference between prostate delineation in magnetic resonance (MR) and computer tomography (CT) images for radiotherapy treatment planning. PATIENTS AND METHODS: Three radiation oncologists, considered experts in the field, outlined the prostate without seminal vesicles both on CT, and axial, coronal, and sagittal MR images for 18 patients. To compare the resulting delineated prostates, the CT and MR scans were matched in three-dimensions using chamfer matching on bony structures. The volumes were measured and the interscan and interobserver variation was determined. The spatial difference between delineation in CT and MR (interscan variation) as well as the interobserver variation were quantified and mapped three-dimensionally (3D) using polar coordinates. A urethrogram was performed and the location of the tip of the dye column was compared with the apex delineated in CT and MR images. RESULTS: Interscan variation: CT volumes were larger than the axial MR volumes in 52 of 54 delineations. The average ratio between the CT and MR volumes was 1.4 (standard error of mean, SE: 0.04) which was significantly different from 1 (p < 0.005). Only small differences were observed between the volumes outlined in the various MR scans, although the coronal MR volumes were smallest. The CT derived prostate was 8 mm (standard deviation, SD: 6 mm) larger at the base of the seminal vesicles and 6 mm (SD 4 mm) larger at the apex of the prostate than the axial MRI. Similar figures were obtained for the CT and the other MRI scans. Interobserver variation: The average ratio between the volume derived by one observer for a particular scan and patient and the average volume was 0.95, 0.97, and 1.08 (SE 0.01) for the three observers, respectively. The 3D pattern of the overall observer variation (1 SD) for CT and axial MRI was similar and equal to 3.5 to 2.8 mm at the base of the seminal vesicles and 3 mm at the apex. CONCLUSION: CT-derived prostate volumes are larger than MR derived volumes, especially toward the seminal vesicles and the apex of the prostate. This interscan variation was found to be larger than the interobserver variation. Using MRI for delineation of the prostate reduces the amount of irradiated rectal wall, and could reduce rectal and urological complications.

Aged↗