Search PubMed⌕ Search

Biomedical subjects

J V Hajnal

Publications and source records attributed to J V Hajnal.

At least 19 recordsLinked to original sources

Prediction of specific absorption rate in mother and fetus associated with MRI examinations during pregnancy.

There is uncertainty regarding the risk posed by magnetic resonance imaging (MRI) examinations to pregnant patients. The most frequently used methods, such as single-shot fast spin echo (ssFSE), often require operation at the specific absorption rate (SAR) limits imposed by safety guidelines. With the introduction of higher-field systems, such limits will be even more significant for fetal imaging. An electromagnetic solver based on the time domain finite integration technique (FIT) was used to predict SAR in an anatomically realistic model of a pregnant patient (28 weeks' gestation) associated with the radiofrequency (RF) fields from birdcage body coils typical of 1.5 T and 3 T MRI systems (i.e., operating at approximately 64 and 127 MHz, respectively). The results suggest that 1) the highest local SAR is in the mother, with the fetus being exposed to a peak of approximately 40-60% of that value at 64 MHz, increasing to approximately 50-70% at 127 MHz; 2) compliance with U.S. Food and Drug Administration (FDA) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines requires control of SAR values averaged over 1 g or 10 g of tissue, respectively; and 3) compliance with Medical Device Agency (MDA) guidelines requires control of the maximum SAR(10g) within the fetus.

Absorption↗

Technical report: Magnetic resonance direct thrombus imaging at 3 T field strength in patients with lower limb deep vein thrombosis: a feasibility study.

AIM: To investigate the feasibility of imaging lower limb deep vein thrombosis using magnetic resonance imaging (MRI) at 3.0 T magnetic field strength with an optimized a T1 magnetization prepared rapid gradient echo technique (MP-RAGE) in patients with normal volunteers as controls. MATERIALS AND METHODS: Patients with deep vein thrombosis (n = 4), thrombophlebitis (n = 2) and healthy volunteers (n = 9) were studied. MRI of the distal thigh and upper calf was performed at 3.0 T with MP-RAGE using two pre-pulses to suppress blood and fat (flip angle 15 degrees, echo time 5 ms, and repetition time 10 ms). A qualitative analysis was performed for detection of thrombi and image quality. Contrast-to-noise ratios were determined in thrombosed and patent veins. RESULTS: Thrombi were clearly visible as high-signal intensity structures with good suppression of the anatomical background. A blinded reader accurately diagnosed 15 out of 16 cases. The contrast-to-noise ratio measurements showed a positive contrast of thrombus over background muscle 16.9 (SD 4.3, 95% CI: 12.5-21.3) and a negative contrast of the lumen to muscle in patent veins of normal volunteers -7.8 (SD 4.3, 95% CI: -11.1 to -4.5), with p = 0.0015. CONCLUSION: Thrombi generate high signal intensity at 3.0 T allowing for their direct visualization if flowing blood, stationary blood and fat are sufficiently suppressed. This preliminary data supports the development of these techniques for other vascular applications.

Adult↗

Interpolation artefacts in non-rigid registration.

Voxel based non-rigid registration of images involves finding a similarity maximising transformation that deforms a source image to the coordinate system of a target image. In order to do this, interpolation is required to estimate the source intensity values corresponding to transformed target voxels. These interpolated source intensities are used when calculating the similarity measure being optimised. In this work, we compare the extent and nature of artefactual displacements produced by voxel based non-rigid registration techniques for different interpolators and investigate their relationship to image noise and global transformation error. A per-voxel similarity gradient is calculated and the resulting vector field is used to characterise registration artefacts for each interpolator. Finally, we show that the resulting registration artefacts can generate spurious volume changes for image pairs with no expected volume change.

Algorithms↗

Schizophrenia syndromes associated with changes in ventricle-to-brain ratios: a serial high-resolution three-dimensional magnetic resonance imaging study in first-episode schizophrenia patients using subvoxel registration and semiautomated quantification.

A cohort of patients with first-episode schizophrenia was dichotomised into two age- and sex-matched groups of clinical syndromes, the active and withdrawn, and underwent high-resolution three-dimensional magnetic resonance imaging at baseline and 8 months later. A cohort of age- and sex-matched normal controls was also imaged at the same time intervals. The application of subvoxel registration and semiautomated quantification techniques demonstrated a significantly different outcome in ventricular changes between the two groups of patients. Compared with the controls, the withdrawn patients showed progressive ventricular enlargement, with an increase in ventricle-to-brain volume ratio, whereas the active group showed a reduction in ventricle-to-brain volume ratio, with a change opposite in sign and smaller in magnitude. These findings lend further support for the aetiological validity of this syndromal model of schizophrenia and are likely to be of importance in furthering our understanding of its pathogenesis and in the development of suitable therapeutic strategies.

Adult↗

A comparison of MR cholangiopancreatography at 1.5 and 3.0 Tesla.

Clinical MR systems operating at 3.0 Tesla have the potential to significantly improve spatial resolution due to the boost in intrinsic signal to noise ratio. However, body imaging at these field strengths presents a number of technical challenges. We performed a prospective pilot study in which 10 patients underwent an MR cholangiopancreatography (MRCP) examination consecutively on 1.5 and 3.0 Tesla systems (both Philips Intera). An axial half Fourier segmented turbo spin echo (HASTE) sequence and a coronal thick-slab 2D turbo-spin echo (TSE) sequence were compared on both systems. A reader measured the signal intensity (SI) ratios of common bile duct (CBD): liver, and CBD: fat on HASTE images and CBD: liver on the TSE images. A second reader performed a qualitative analysis of the intrahepatic and extrahepatic biliary anatomy. Quantitative data was compared using the paired t-test and qualitative data with the paired Wilcoxon signed rank test with p < 0.05. The quantitative analysis of the HASTE sequences showed a slightly higher signal intensity ratio (CBD:liver) at 3.0 Tesla compared with 1.5 Tesla (8.1 vs 5.6, p = 0.002). No significant difference was found between the SI ratios of (CBD:fat) on HASTE images or (CBD:liver) on TSE images. The qualitative analysis showed superior image quality of 3.0 Tesla over 1.5 Tesla images on both HASTE (31 vs 25, p = 0.032), and TSE sequences (34 vs 28, p = 0.043). This pilot study shows that MRCP is feasible at 3.0 Tesla with some improvement in image quality and signal characteristics. Further development may be achieved with sequence optimization and improved coil design.

Adult↗

Spatial transformation of motion and deformation fields using nonrigid registration.

In this paper, we present a technique that can be used to transform the motion or deformation fields defined in the coordinate system of one subject into the coordinate system of another subject. Such a transformation accounts for the differences in the coordinate systems of the two subjects due to misalignment and size/shape variation, enabling the motion or deformation of each of the subjects to be directly quantitatively and qualitatively compared. The field transformation is performed by using a nonrigid registration algorithm to determine the intersubject coordinate system mapping from the first subject to the second subject. This fixes the relationship between the coordinate systems of the two subjects, and allows us to recover the deformation/motion vectors of the second subject for each corresponding point in the first subject. Since these vectors are still aligned with the coordinate system of the second subject, the inverse of the intersubject coordinate mapping is required to transform these vectors into the coordinate system of the first subject, and we approximate this inverse using a numerical line integral method. The accuracy of our numerical inversion technique is demonstrated using a synthetic example, after which we present applications of our method to sequences of cardiac and brain images.

Algorithms↗

Fatigue and primary biliary cirrhosis: association of globus pallidus magnetisation transfer ratio measurements with fatigue severity and blood manganese levels.

BACKGROUND AND AIM: Fatigue is the commonest symptom in primary biliary cirrhosis (PBC), affecting individuals at all stages of disease. The pathogenesis of fatigue in PBC is unknown although rat models suggest a central nervous system (CNS) cause. We examined the hypothesis that a CNS abnormality related to cholestasis, rather than cirrhosis per se, underlies this symptom. PATIENTS AND METHODS: Fourteen patients with precirrhotic PBC (stage I-II disease), four patients with stage III-IV PBC, and 11 healthy women were studied using cerebral magnetisation contrast imaging and proton magnetic resonance spectroscopy (MRS). RESULTS: The globus pallidus magnetisation transfer ratio (MTR), a quantifiable tissue characteristic that may be abnormal in the presence of normal magnetic resonance imaging, was significantly reduced in precirrhotic PBC patients compared with healthy controls. These measurements correlated with blood manganese levels and were more abnormal in the more fatigued subjects. There were no differences in MRS measurements between the three study groups, suggesting that the abnormal MTR was not related to hepatic encephalopathy. CONCLUSION: This study suggests that impairments in liver function in PBC may adversely affect the brain long before the development of cirrhosis and hepatic encephalopathy, possibly as a result of altered manganese homeostasis within the CNS.

Adult↗

SMASH navigators.

The additional data acquired when using multiple receiver coils is commonly used to improve SNR or reduce acquisition times. It may also be used to remove image artifacts by selectively replacing corrupt data. In the present study, a correction scheme is presented based on simultaneous acquisition of spatial harmonics (SMASH) that enables detection and correction of motion artifacts caused by 2D translations. Newly measured data is compared with predictions from previously measured data by making negative and positive spatial harmonics. Differences are attributed to motion occurring in the interval between the acquisition of separate phase encode lines and correction parameters are determined. Two types of rigid body motion are considered: 1) object and coil array move, and 2) object only moves, since each causes different phase errors in k-space. Simulation, phantom, and volunteer experiments demonstrate the validity of the technique.

Artifacts↗

Combination of signals from array coils using image-based estimation of coil sensitivity profiles.

It is well established that the optimal unbiased way to combine image data from array coils is a pixel-by-pixel sum of coil signals, with each signal weighted by the individual coil sensitivity at the location of the pixel. A pragmatic alternative combines the images from the coils as the square root of the sum of squares (SOS), which can reduce the signal-to-noise ratio (SNR) and introduce bias. This work describes how to replace coil sensitivity by an image-derived quantity that enables close to optimal signal combination up to a global intensity scaling. Typical scaling is by an individual coil sensitivity or a linear or SOS combination of the sensitivities of some or all of the coils in the array. The method decreases signal bias, improves SNR when coils have unequal noise levels, and can reduce image artifacts. It can produce phase-corrected data, which eliminates bias completely. In addition, the method allows images from arrays that include highly localized coils, such as a prostate coil and external pelvic array, to be combined with near-optimal SNR and an intensity modulation that makes them easier to view.

Equipment Design↗

Detection and elimination of motion artifacts by regeneration of k-space.

A method has been developed using techniques from partially parallel imaging (PPI) to detect localized inconsistencies in k-space that are caused by certain types of motion. The inconsistent data are discarded and consistent data regenerated from the remaining data using PPI techniques. The price is a small decrease in signal-to-noise ratio (SNR) and additional postprocessing. An iterative scheme is presented which does not require separately acquired coil sensitivity information for the PPI reconstructions. This method has been found to reduce artifact levels in phantom and in vivo test studies.

Artifacts↗

Relative increase in choline in the occipital cortex in chronic fatigue syndrome.

OBJECTIVE: To test the hypothesis that chronic fatigue syndrome (CFS) is associated with altered cerebral metabolites in the frontal and occipital cortices. METHOD: Cerebral proton magnetic resonance spectroscopy (1H MRS) was carried out in eight CFS patients and eight age- and sex-matched healthy control subjects. Spectra were obtained from 20 x 20 x 20 mm3 voxels in the dominant motor and occipital cortices using a point-resolved spectroscopy pulse sequence. RESULTS: The mean ratio of choline (Cho) to creatine (Cr) in the occipital cortex in CFS (0.97) was significantly higher than in the controls (0.76; P=0.008). No other metabolite ratios were significantly different between the two groups in either the frontal or occipital cortex. In addition, there was a loss of the normal spatial variation of Cho in CFS. CONCLUSION: Our results suggest that there may be an abnormality of phospholipid metabolism in the brain in CFS.

Adult↗

Subvoxel image registration of multislice (2D) magnetic resonance images in patients with high-grade gliomas of the brain.

AIMS: To implement a multislice two-dimensional (2D) T2-weighted sequence suitable for subvoxel image registration and to assess its usefulness in detecting change in high-grade intracranial gliomas. MATERIALS AND METHODS: Twenty patients with high-grade gliomas were studied on two or more occasions. T2-weighted multislice pulse sequences with a Gaussian slice profile, 50% overlapping slices and nearly isotropic voxels were acquired. The images were registered and subtraction images were produced. The images were compared with three-dimensional (3D) T1-weighted registered images and conventional unregistered T2-weighted images. All images were scored for changes in the lesions and ventricular system. RESULTS: The 2D and 3D registered subtraction images were the most sensitive for detecting changes in both the lesions and other regions in the brain. The mean rank scores were significantly higher for the lesions (chi2=86.742; df=5, n=38, P<0.0001) and for the ventricles (chi2=63.837; df=5, n=35, P<0.0001) compared with the unregistered and registered anatomical images. The subtraction images were also most sensitive for detecting signal intensity changes irrespective of the direction of change. CONCLUSION: Rigid body subvoxel registration can be successfully performed with both multislice 2D and 3D imaging. In principle, virtually all forms of clinical MR images of the brain can be accurately registered and subtracted.

Adult↗

Magnetic resonance imaging in preeclampsia and eclampsia complicated by visual disturbance and other neurological abnormalities.

This study describes magnetic resonance imaging findings in women presenting with neurological complications associated with preeclampsia and eclampsia. One eclamptic and two preeclamptic women were studied after presenting with postpartum neurological events. In two women the brain increased in size on the initial follow-up images, following the same pattern seen in normal pregnancy. In the other woman, the brain was decreased in size at 13 days postpartum but increased in size at six weeks postpartum. This initial reduction in brain size may reflect the resolution of cerebral oedema resulting from underlying pathological processes.

Journal Article↗

Serial brain MRI at 3-6 month intervals as a surrogate marker for Alzheimer's disease.

A surrogate marker is needed for Alzheimer's disease (AD) both to aid diagnosis and to assess interventions. Despite widespread use, brain imaging markers have largely been confounded by overlap with "normal" ageing. 39 elderly subjects completed up to four serial volumetric brain MRI scans with intervals from 2.5 months to 7 months. By National Institute of Neurological and Communicative Disorders and Stroke (NINCDS) criteria, five subjects had probable AD, two possible AD and 32 were negative for AD, although this group included memory-impaired subjects. Total brain and ventricular volumes were measured for each scan, and rates of change for each interval calculated. The rate of change in ventricle-to-brain ratio was 15.6% per year (standard deviation (SD) 2.8%) for probable AD compared with 4.3% per year (SD 1.1%) for negative AD (p<0.001). There was no significant difference between these groups' mean ventricle-to-brain ratios measured at a single time point (p=0.25). Rates of change in brain or ventricular volume over time also differed between the two groups (p<0.001). Power calculations reveal that to detect a 20% reduction in the excess rate of atrophy of a probable AD cohort in just 6 months, with 90% power, 135 subjects would be required in each arm of a randomized placebo controlled trial. For a 30% reduction in the excess rate of atrophy, 61 subjects would be required. Rate of change analysis makes serial brain MRI a valuable surrogate marker for Alzheimer's disease. Since only 6 months or less is required between scans, this procedure has both clinical relevance and potential for monitoring interventions.

Aged↗

Magnetic resonance: magic angle imaging of the Achilles tendon.

Tendons do not normally produce detectable signals with conventional magnetic-resonance techniques and are recognised as dark signal voids. However, if tendons are examined at 55 degrees to the static magnetic field (the "magic angle"), signals become detectable and the tendons can become the brightest structure on the image. We have used this approach to establish tendon relaxation times and magnetisation transfer ratios and to show contrast enhancement. We have also shown more detail of acute and chronic tendon rupture by this method compared with images made with the tendon parallel to the static magnetic field.

Achilles Tendon↗

MRI changes in multiple sclerosis following treatment with lofepramine and L-phenylalanine.

As part of a large, randomized placebo-controlled trial of inpatients with multiple sclerosis (MS), a subsample of 15 underwent cerebral MRI at baseline and 6-months (eight on lofepramine and l-phenylalanine; seven on placebo). Unlike the placebo group, the active group showed a significant reduction in lesion number visible on T1-weighted scans (p < 0.05). The lateral ventricular volume increased, on average, by 1020 mm3 in the untreated group and 600 mm3 in the treated group. In the treated patients the ventricular size change correlated with both change in Gulick MS-related symptoms scale scores (rs = 0.71, p = 0.07) and Gulick MS-related activities of daily living scale scores (rs = -0.83, p = 0.02). It is concluded that treatment with lofepramine and l-phenylalanine is associated with significant MRI changes.

Adult↗

A comparison of (18)F-dopa PET and inversion recovery MRI in the diagnosis of Parkinson's disease.

OBJECTIVE: To quantify structural changes in the substantia nigra of patients with PD with inversion recovery MRI and to compare these with striatal dopaminergic function measured with (18)F-dopa PET. METHODS: The authors studied 10 patients with PD and eight age-matched control subjects with a combination of MR sequences previously reported to be sensitive to nigral cell loss. Striatal regions of interest were defined on T1-weighted MRI coregistered to (18)F-dopa PET in all subjects. RESULTS: Discriminant function analysis of the quantified MR nigral signal correctly classified 83% of the combined PD patient/control group; three of 10 PD cases were incorrectly classified as "normal" (Wilks' lambda = 0.724, p > 0.05). Discriminant function analysis correctly classified 100% of PD patients and control subjects with (18)F-dopa PET based on mean caudate and putamen K(i) values (Wilks' lambda = 0.065, p < 0.001). Correlations between mean putamen K(i) and rostral and caudal nigral MR signal changes and mean caudate K(i) and caudal nigral MR signal changes were found (r = -0.76, -0.69, -0.80, p < 0.05). CONCLUSION: (18)F-dopa PET is more reliable than inversion recovery MRI in discriminating patients with moderately severe PD from normal subjects. However, the structural changes detected within the substantia nigra of patients with PD found using inversion recovery MRI correlate with measures of striatal dopaminergic function using (18)F-dopa PET.

Brain↗