Search PubMed⌕ Search

Biomedical subjects

J V Hajnal

Publications and source records attributed to J V Hajnal.

At least 19 recordsLinked to original sources

SMASH navigators.

The additional data acquired when using multiple receiver coils is commonly used to improve SNR or reduce acquisition times. It may also be used to remove image artifacts by selectively replacing corrupt data. In the present study, a correction scheme is presented based on simultaneous acquisition of spatial harmonics (SMASH) that enables detection and correction of motion artifacts caused by 2D translations. Newly measured data is compared with predictions from previously measured data by making negative and positive spatial harmonics. Differences are attributed to motion occurring in the interval between the acquisition of separate phase encode lines and correction parameters are determined. Two types of rigid body motion are considered: 1) object and coil array move, and 2) object only moves, since each causes different phase errors in k-space. Simulation, phantom, and volunteer experiments demonstrate the validity of the technique.

Artifacts↗

Combination of signals from array coils using image-based estimation of coil sensitivity profiles.

It is well established that the optimal unbiased way to combine image data from array coils is a pixel-by-pixel sum of coil signals, with each signal weighted by the individual coil sensitivity at the location of the pixel. A pragmatic alternative combines the images from the coils as the square root of the sum of squares (SOS), which can reduce the signal-to-noise ratio (SNR) and introduce bias. This work describes how to replace coil sensitivity by an image-derived quantity that enables close to optimal signal combination up to a global intensity scaling. Typical scaling is by an individual coil sensitivity or a linear or SOS combination of the sensitivities of some or all of the coils in the array. The method decreases signal bias, improves SNR when coils have unequal noise levels, and can reduce image artifacts. It can produce phase-corrected data, which eliminates bias completely. In addition, the method allows images from arrays that include highly localized coils, such as a prostate coil and external pelvic array, to be combined with near-optimal SNR and an intensity modulation that makes them easier to view.

Equipment Design↗

Detection and elimination of motion artifacts by regeneration of k-space.

A method has been developed using techniques from partially parallel imaging (PPI) to detect localized inconsistencies in k-space that are caused by certain types of motion. The inconsistent data are discarded and consistent data regenerated from the remaining data using PPI techniques. The price is a small decrease in signal-to-noise ratio (SNR) and additional postprocessing. An iterative scheme is presented which does not require separately acquired coil sensitivity information for the PPI reconstructions. This method has been found to reduce artifact levels in phantom and in vivo test studies.

Artifacts↗

Relative increase in choline in the occipital cortex in chronic fatigue syndrome.

OBJECTIVE: To test the hypothesis that chronic fatigue syndrome (CFS) is associated with altered cerebral metabolites in the frontal and occipital cortices. METHOD: Cerebral proton magnetic resonance spectroscopy (1H MRS) was carried out in eight CFS patients and eight age- and sex-matched healthy control subjects. Spectra were obtained from 20 x 20 x 20 mm3 voxels in the dominant motor and occipital cortices using a point-resolved spectroscopy pulse sequence. RESULTS: The mean ratio of choline (Cho) to creatine (Cr) in the occipital cortex in CFS (0.97) was significantly higher than in the controls (0.76; P=0.008). No other metabolite ratios were significantly different between the two groups in either the frontal or occipital cortex. In addition, there was a loss of the normal spatial variation of Cho in CFS. CONCLUSION: Our results suggest that there may be an abnormality of phospholipid metabolism in the brain in CFS.

Adult↗

Subvoxel image registration of multislice (2D) magnetic resonance images in patients with high-grade gliomas of the brain.

AIMS: To implement a multislice two-dimensional (2D) T2-weighted sequence suitable for subvoxel image registration and to assess its usefulness in detecting change in high-grade intracranial gliomas. MATERIALS AND METHODS: Twenty patients with high-grade gliomas were studied on two or more occasions. T2-weighted multislice pulse sequences with a Gaussian slice profile, 50% overlapping slices and nearly isotropic voxels were acquired. The images were registered and subtraction images were produced. The images were compared with three-dimensional (3D) T1-weighted registered images and conventional unregistered T2-weighted images. All images were scored for changes in the lesions and ventricular system. RESULTS: The 2D and 3D registered subtraction images were the most sensitive for detecting changes in both the lesions and other regions in the brain. The mean rank scores were significantly higher for the lesions (chi2=86.742; df=5, n=38, P<0.0001) and for the ventricles (chi2=63.837; df=5, n=35, P<0.0001) compared with the unregistered and registered anatomical images. The subtraction images were also most sensitive for detecting signal intensity changes irrespective of the direction of change. CONCLUSION: Rigid body subvoxel registration can be successfully performed with both multislice 2D and 3D imaging. In principle, virtually all forms of clinical MR images of the brain can be accurately registered and subtracted.

Adult↗

Serial brain MRI at 3-6 month intervals as a surrogate marker for Alzheimer's disease.

A surrogate marker is needed for Alzheimer's disease (AD) both to aid diagnosis and to assess interventions. Despite widespread use, brain imaging markers have largely been confounded by overlap with "normal" ageing. 39 elderly subjects completed up to four serial volumetric brain MRI scans with intervals from 2.5 months to 7 months. By National Institute of Neurological and Communicative Disorders and Stroke (NINCDS) criteria, five subjects had probable AD, two possible AD and 32 were negative for AD, although this group included memory-impaired subjects. Total brain and ventricular volumes were measured for each scan, and rates of change for each interval calculated. The rate of change in ventricle-to-brain ratio was 15.6% per year (standard deviation (SD) 2.8%) for probable AD compared with 4.3% per year (SD 1.1%) for negative AD (p<0.001). There was no significant difference between these groups' mean ventricle-to-brain ratios measured at a single time point (p=0.25). Rates of change in brain or ventricular volume over time also differed between the two groups (p<0.001). Power calculations reveal that to detect a 20% reduction in the excess rate of atrophy of a probable AD cohort in just 6 months, with 90% power, 135 subjects would be required in each arm of a randomized placebo controlled trial. For a 30% reduction in the excess rate of atrophy, 61 subjects would be required. Rate of change analysis makes serial brain MRI a valuable surrogate marker for Alzheimer's disease. Since only 6 months or less is required between scans, this procedure has both clinical relevance and potential for monitoring interventions.

Aged↗

Magnetic resonance: magic angle imaging of the Achilles tendon.

Tendons do not normally produce detectable signals with conventional magnetic-resonance techniques and are recognised as dark signal voids. However, if tendons are examined at 55 degrees to the static magnetic field (the "magic angle"), signals become detectable and the tendons can become the brightest structure on the image. We have used this approach to establish tendon relaxation times and magnetisation transfer ratios and to show contrast enhancement. We have also shown more detail of acute and chronic tendon rupture by this method compared with images made with the tendon parallel to the static magnetic field.

Achilles Tendon↗

MRI changes in multiple sclerosis following treatment with lofepramine and L-phenylalanine.

As part of a large, randomized placebo-controlled trial of inpatients with multiple sclerosis (MS), a subsample of 15 underwent cerebral MRI at baseline and 6-months (eight on lofepramine and l-phenylalanine; seven on placebo). Unlike the placebo group, the active group showed a significant reduction in lesion number visible on T1-weighted scans (p < 0.05). The lateral ventricular volume increased, on average, by 1020 mm3 in the untreated group and 600 mm3 in the treated group. In the treated patients the ventricular size change correlated with both change in Gulick MS-related symptoms scale scores (rs = 0.71, p = 0.07) and Gulick MS-related activities of daily living scale scores (rs = -0.83, p = 0.02). It is concluded that treatment with lofepramine and l-phenylalanine is associated with significant MRI changes.

Adult↗

A comparison of (18)F-dopa PET and inversion recovery MRI in the diagnosis of Parkinson's disease.

OBJECTIVE: To quantify structural changes in the substantia nigra of patients with PD with inversion recovery MRI and to compare these with striatal dopaminergic function measured with (18)F-dopa PET. METHODS: The authors studied 10 patients with PD and eight age-matched control subjects with a combination of MR sequences previously reported to be sensitive to nigral cell loss. Striatal regions of interest were defined on T1-weighted MRI coregistered to (18)F-dopa PET in all subjects. RESULTS: Discriminant function analysis of the quantified MR nigral signal correctly classified 83% of the combined PD patient/control group; three of 10 PD cases were incorrectly classified as "normal" (Wilks' lambda = 0.724, p > 0.05). Discriminant function analysis correctly classified 100% of PD patients and control subjects with (18)F-dopa PET based on mean caudate and putamen K(i) values (Wilks' lambda = 0.065, p < 0.001). Correlations between mean putamen K(i) and rostral and caudal nigral MR signal changes and mean caudate K(i) and caudal nigral MR signal changes were found (r = -0.76, -0.69, -0.80, p < 0.05). CONCLUSION: (18)F-dopa PET is more reliable than inversion recovery MRI in discriminating patients with moderately severe PD from normal subjects. However, the structural changes detected within the substantia nigra of patients with PD found using inversion recovery MRI correlate with measures of striatal dopaminergic function using (18)F-dopa PET.

Brain↗

A serial longitudinal quantitative MRI study of cerebral changes in first-episode schizophrenia using image segmentation and subvoxel registration.

Lateral ventricular enlargement is the most consistently replicated brain abnormality found in schizophrenia. This article reports a first episode, longitudinal study of ventricular volume using high-resolution serial magnetic resonance imaging (MRI) and recently developed techniques for image registration and quantitation. Baseline and follow-up (on average 8 months later) MRI scans were carried out on 24 patients and 12 controls. Accurate subvoxel registration was performed and subtraction images were produced to reveal areas of regional brain change. Whereas there were no differences between patients and controls with respect to the mean change in ventricular volume, the patients were much more variable in this respect and showed larger increases and decreases. The percentage increase in ventricular size was greater than one standard deviation of control values for 14 patients and the percentage decrease exceeded one standard deviation in eight patients. Although the finding of progressive ventricular enlargement in a proportion of patients supports other studies indicating an ongoing neuropathological process in the early stages of schizophrenia, the reduction of ventricular size in the remaining patients is more difficult to explain. It is suggested that this may reflect improvement in nutrition and hydration following treatment.

Adult↗

Microstructured magnetic materials for RF flux guides in magnetic resonance imaging.

Magnetic resonance imaging and spectroscopy systems use coils, either singly or as arrays, to intercept radio-frequency (RF) magnetic flux from regions of interest, often deep within the body. Here, we show that a new magnetic material offers novel possibilities for guiding RF flux to the receiver coil, permitting a clear image to be obtained where none might otherwise be detectable. The new material contains microstructure designed according to concepts taken from the field of photonic band gap materials. In the RF range, it has a magnetic permeability that can be produced to specification while exhibiting negligible direct-current magnetism. The latter property is vital to avoid perturbing the static and audio-frequency magnetic fields needed to obtain image and spectral data. The concept offers a new paradigm for the manipulation of RF flux in all nuclear magnetic resonance systems.

Humans↗

Use of multicoil arrays for separation of signal from multiple slices simultaneously excited.

Increased acquisition efficiency has been achieved by exciting several slices simultaneously. The mixed data were unfolded to produce separate slices using the spatial encoding information inherent in a multicoil receiver system. Each coil yields a linear combination of signals from all excited slices weighted by the sensitivity of each coil. A matrix inversion provides a solution to unfold these images.

Equipment Design↗

An investigation into the use of sensitivity-encoded techniques to increase temporal resolution in dynamic contrast-enhanced breast imaging.

Gadolinium-enhanced dynamic magnetic resonance (MR) imaging is playing an increasingly important diagnostic role in patients with breast cancer. Because of the multi-focal nature of the disease, it is mandatory to cover all of both breasts, not only in the initial scan, but also at subsequent follow-up. This requires volume acquisitions with a temporal resolution limited to 60-80 seconds, which is insufficient to clearly discriminate malignant from benign rates of contrast uptake. In this work, we performed sensitivity-encoded imaging using a commercially available four-channel breast coil (MRI Devices Corporation) on a commercial 0.5-T scanner with moderate gradient performance to give increased temporal resolution in these dynamic contrast-enhanced scans. A two-fold increase in temporal resolution was readily achievable with this coil. Image reconstruction was robust and image quality was assessed qualitatively to be good. We also investigated higher speed-up factors using two directions of sensitivity-encoded reduction and discussed some of the potential artifacts associated with such imaging.

Artifacts↗

FLAIR imaging using nonselective inversion pulses combined with slice excitation order cycling and k-space reordering to reduce flow artifacts.

High-signal artifacts produced by cerebrospinal fluid (CSF) flow can adversely affect fluid-attenuated inversion recovery (FLAIR) imaging of the brain and spinal cord. This study explores the use of a nonslice-selective inversion pulse to eliminate CSF flow artifacts together with a technique called "K-space Reordered by Inversion-time for each Slice Position" (KRISP) to achieve constant contrast in a multislice acquisition. Theory shows that with this method the CSF point spread function (PSF) has a minimum at the center and attenuated side lobes, providing CSF suppression, but residual edge signals remain. The PSF for brain is only mildly attenuated and signals for extended regions are not attenuated. KRISP FLAIR sequences were assessed in 15 patients (10 brain and five spinal cord cases). The images showed reduced CSF and blood flow artifacts and higher conspicuity of the cortex, meninges, ventricular system, brainstem, and cerebellum when compared with conventional FLAIR sequences.

Adult↗

Diffusion-weighted imaging of the spine using radial k-space trajectories.

INTRODUCTION: Diffusion-weighted MR imaging (DWI) of the spine requires robust imaging methods, that are insensitive to susceptibility effects caused by the transition from bone to soft tissue and motion artifacts due to breathing, swallowing, and cardiac motion. The purpose of this study was to develop a robust imaging method suitable for DWI of the spine. METHODS AND SUBJECTS: A radial k-space spin echo sequence has been implemented, which is self-navigating because each acquisition line passes through the origin of k-space. Influence of cardiac motion and associated flow of cerebrospinal fluid is minimized by cardiac gating with a finger photoplethysmograph. The sequence has been tested on a 1.5T system. Diffusion-weighted images of six normal volunteers were acquired in the sagittal plane with 4 b values between 50 and 500 s mm(-2). Because of the symmetries of the cord, diffusion measurements in the head-foot (HF) or left-right (LR) directions were sufficient to measure the dominant effects of anisotropy. RESULTS: The apparent diffusion coefficients (ADCs) measured, respectively, in the LR and HF directions were (0.699+/-0.050)x10(-3) and (1.805+/-0.086)x10(-3) mm(2) s(-1) in the spinal cord, (1.588+/-0.082)x10(-3) and (1.528+/-0.052)x10(-3) mm(2) s(-1) in the intervertebral disks, and (0.346+/-0.047)x10(-3) and (0.306+/-0.035)x10(-3) mm(2) s(-1) in the vertebrae of the cervicothoracic spine. CONCLUSION: Diffusion-weighted spin echo sequences with radial trajectories in k-space provide a means of achieving robust, high quality diffusion-weighted imaging and measuring ADCs in the spine. The application of the diffusion-weighting gradients in different directions allows diffusion anisotropy to be measured.

Humans↗

How to perform diffusion-weighted imaging.

Diffusion-weighted imaging (DWI) has become an invaluable tool in the management of patients with stroke. DWI relies on detecting the random diffusion of water molecules. In normal tissues this movement may be restricted by the presence of cellular structures, which provide a barrier to free movement. This occurs in myelinated white matter, where movement is restricted more across than along fibres. This directional dependence is termed anisotropic restricted diffusion. The diffusion of water molecules can be made the dominant contrast mechanism within an image by applying large magnetic field gradients. The pulsed gradient spin echo (PGSE) sequence provides sensitivity to diffusion with gradient pulses either side of the 180 degrees refocusing pulse. This sequence is generally heavily T2 weighted. In order to detect normal anisotropic properties within the different components of the medullary core, association, commissural and projection fibres, DWI must be performed with sensitisation in at least three directions. PGSE sequences have been used to obtain the diffusion coefficient (D*), a measure of mobility at the molecular level within tissue. In acute infarction D* is increased; in brain death it is decreased. Diffusion contrast needs to be optimised in relation to the highly T2-dependent nature of PGSE sequences. This also requires a more detailed knowledge of how D* changes in disease, but information on nonischaemic neurological conditions is still very limited.

Adult↗

Associations between central and peripheral measures of phospholipid breakdown revealed by cerebral 31-phosphorus magnetic resonance spectroscopy and fatty acid composition of erythrocyte membranes.

1. Abnormal neuronal membrane phospholipid metabolism is increasingly recognized as being of central importance to a number of neuropsychiatric disorders. Currently, two important indices of membrane phospholipid metabolism tend to be measured: the ratio of the areas of the phosphomonoester (PME) and phosphodiester (PDE) peaks from in vivo cerebral phosphorus magnetic resonance spectroscopy (31P MRS) studies; and erythrocyte membrane fatty acid concentrations. Thus far, there have been no studies comparing these two indices to ascertain the extent to which they agree. 2. The authors measured these indices in nine normal adults. Spectral localization was achieved using four-dimensional chemical shift imaging methods and erythrocyte membrane fatty acid concentrations (from blood samples taken at the time of scanning) were measured using gas liquid chromatography. 3. Levels of PDE (an index of phospholipid catabolism), measured using cerebral 31P MRS, were significantly correlated with reduced concentrations of the highly unsaturated fatty acids docosahexaenoic acid (DHA) (r = -0.68, p < 0.05) and eicosapentaenoic acid (EPA) (r -0.78, p < 0.02). No significant correlations were found between peripheral concentrations of any highly unsaturated fatty acids and PME levels, nor between their essential fatty acid precursors and either PDE or PME levels. Other 31-phosphorus metabolites also showed no significant correlations with the blood fatty acid measures. 4. The correlations between central measures of PDE and peripheral measures of DHA and EPA provide validation of cerebral 31P MRS as a non-invasive technique for the study of membrane phospholipid metabolism in vivo.

Adult↗

Contributions of an adiabatic initial inversion pulse and K-space re-ordered by inversion-time at each slice position (KRISP) to control of CSF artifacts and visualization of the brain in FLAIR magnetic resonance imaging.

AIM: The aim of this study was to compare the performance of three fluid attenuated inversion recovery (FLAIR) pulse sequences for control of cerebrospinal fluid (CSF) and blood flow artifacts in imaging of the brain. The first of these sequences had an initial sinc inversion pulse which was followed by conventional k-space mapping. The second had an initial sinc inversion pulse followed by k-space re-ordered by inversion time at each slice position (KRISP) and the third had an adiabatic initial inversion pulse followed by KRISP. MATERIALS AND METHODS: Ten patients with established disease were studied with all three pulse sequences. Seven were also studied with the adiabatic KRISP sequence after contrast enhancement. Their images were evaluated for patient motion artifact, CSF and blood flow artifact as well as conspicuity of the cortex, meninges, ventricular system, brainstem and cerebellum. The conspicuity of lesions and the degree of enhancement were also evaluated. RESULTS: Both the sinc and adiabatic KRISP FLAIR sequences showed better control of CSF and blood flow artifacts than the conventional FLAIR sequence. In addition the adiabatic KRISP FLAIR sequence showed better control of CSF artifact at the inferior aspect of the posterior fossa. The lesion conspicuity was similar for each of the FLAIR sequences as was the degree of contrast enhancement to that shown with a T(1)weighted spin echo sequence. CONCLUSION: The KRISP FLAIR sequence controls high signal artifacts from CSF flow and blood flow and the adiabatic pulse controls high signal artifacts due to inadequate inversion of the CSF magnetization at the periphery of the head transmitter coil. The KRISP FLAIR sequence also improves cortical and meningeal definition as a result of an edge enhancement effect. The effects are synergistic and can be usefully combined in a single pulse sequence. Curati, W. L.et al. (2001)Clinical Radiology56, 375-384

Adult↗