Search PubMed⌕ Search

Biomedical subjects

J Ty Hopkins

Publications and source records attributed to J Ty Hopkins.

3 recordsLinked to original sources

Intrasession and intersession reliability of the quadriceps Hoffmann reflex.

The Hoffmann reflex (H-reflex) is a resting electromyographic (EMG) measurement of motoneuron pool recruitment. While the soleus H-reflex has been studied extensively, the study of the quadriceps H-reflex has been limited for various reasons. To date no data exist regarding the reliability of this measurement within and between sessions over an extended period of time. The purpose of this study was to establish quadriceps H-reflex reliability over a four-week period consisting of 6 testing sessions. Eleven neurologically sound volunteers (age: 20 +/- 2 yr, height: 181.9 +/- 9.9 cm; mass: 84.2 +/- 17.8 Kg) participated in this study. Subjects were prepared for EMG surface electrodes over the vastus medialis and medial malleolus (ground). A stimulating bar electrode was placed over the femoral nerve, and a stimulus was delivered at 20 sec intervals with increasing amplitude to obtain a peak quadriceps H-reflex. Ten peak H-reflex measurements were recorded for each session. The stimulator amplitude was increased further to obtain the peak efferent motor response (M-response) for normalization of peak H-reflex measurements. The procedure was repeated at 1 hr, 24 hr, 1, 2, and 3 weeks following the initial session. Intraclass correlation coefficients (ICC (2.1) and ICC (3.1)) were calculated using normalized peak H-reflex measurements. Strong reliability was detected within a session (10 trials ICC (2.1) = 0.957, ICC (3.1) = 0.970; 5 trials ICC (2.1) = 0.961, (ICC (3.1) = 0.970). ICC (2.1) calculations yielded strong reliability between the first and second (1 hr) session (0.956) but moderate reliability between days 1 and 2 (0.787) and between all session over 4 weeks (0.756). ICC (3.1) calculations were also computed to determine the reliability for the fixed selection of sessions. This calculation yielded strong reliabilities between days 1 and 2 (0.969) and between all sessions over 4 weeks (0.911). Within a measurement session quadriceps H-reflex measurements are very reliable, and we recommend 5 trials to establish a measurement. Between measurement sessions these data provide evidence of strong reliability for these fixed sessions (ICC (3.1)), and generalized evidence for moderate reliability over a 4-week period has also been provided (ICC (2.1)). These data provide valuable information for the researcher and practitioner as to the reliability of this measurement in detecting changes in the neuromuscular system.

Adult↗

Ankle cryotherapy facilitates soleus function.

STUDY DESIGN: A 2-factor (group and time) experimental design with repeated measures on time. OBJECTIVES: To determine the effects of ankle cryotherapy on voluntary and resting motor function of the soleus over a 60-minute period. To determine if a relationship exists between changes in torque production and Hoffmann reflex (H-reflex) following ankle joint cryotherapy treatment. BACKGROUND: Controversy surrounds the use of cryotherapy prior to activity and rehabilitation. While cooling muscle may have a deleterious effect on motor function, cooling the joint may enhance motor function around the joint. The H-reflex is a good resting measure of motoneuronal activity. However, its relationship to voluntary activity is unknown. METHODS AND MEASURES: Thirty subjects were pretested (baseline) for normalized H-reflex (defined as the ratio of maximum H-reflex [Hmax] to maximum direct motor response [Mmax]) and peak plantar flexion torque. A crushed ice bag was placed over the ankle of 15 subjects for 30 minutes. H-reflex and torque measurements were collected immediately following the cryotherapy treatment at 30, 60, and 90 minutes. Surface temperatures were recorded from the ankle and electrode site with each measurement interval. RESULTS: Both peak H-reflex and plantar flexion torque at 30, 60, and 90 minutes increased relative to baseline measurements. Each measurement was also greater than the corresponding control at 30, 60, and 90 minutes. A weak correlation (r = 0.38; P = 0.036) existed between changes in H-reflex and plantar flexion torque at 30 minutes. CONCLUSIONS: The soleus motoneuron pool is facilitated following a 30-minute crushed ice application to the ankle and over a 60-minute postcooling period. These data support the use of joint cooling prior to activity and rehabilitation.

Adolescent↗

A joint dilemma.

Explore the source record for details and available documents.

Anterior Cruciate Ligament↗