Comparative contraceptive efficacy of the female condom and other barrier methods.

Because the research design for the clinical trial establishing the contraceptive efficacy of the female condom--a six-month life-table probability of failure of 15% (12% in the United States vs. 22% in Latin America)--did not include randomization with another method of contraception, no definite conclusion about its comparative efficacy is possible. Comparisons using other female barrier methods as historical controls, however, provide evidence that, among women in the United States, the contraceptive efficacy of the female condom during typical use is not significantly different from that of the diaphragm, the sponge or the cervical cap. The six-month probability of failure during perfect use of the female condom is 2.6% among U.S. women, similar to rates for the diaphragm and the cervical cap but significantly lower than that for the sponge. Meaningful comparisons with the male condom are not possible because of the lack of data from carefully controlled prospective clinical trials. Extrapolations from the results on contraceptive efficacy suggest that perfect use of the female condom may reduce the annual risk of acquiring the human immunodeficiency virus by more than 90% among women who have intercourse twice weekly with an infected male.

Clinical Trials as Topic↗

Contraceptive efficacy of the diaphragm, the sponge and the cervical cap.

A reanalysis of data from two clinical studies--in which 1,439 women were randomly assigned to use either the contraceptive sponge or the diaphragm and 1,394 women were randomly assigned to use either the cervical cap or the diaphragm--found first-year probabilities of failure during typical use of 17% for the sponge, 18% for the cervical cap and 13-17% for the diaphragm. The first-year probabilities of failure during perfect use are 11-12% for the sponge, 10-13% for the cervical cap and 4-8% for the diaphragm. The probability of failure during perfect use is significantly higher among women who have given birth than among those who have not for users of the sponge (19-21% vs. 9-10%) and users of the cervical cap (26-27% vs. 8-10%), but not for users of the diaphragm.

Contraceptive Devices, Female↗

Medical care cost savings from adolescent contraceptive use.

An analysis of the economic benefits of adolescent contraceptive use utilizes information from a national private payer database and from the California Medicaid program to compare private- and public-sector costs and savings. The study estimates the costs of acquiring and using 11 contraceptive methods appropriate for adolescents, treating associated side effects, providing medical care related to an unintended pregnancy during method use and treating sexually transmitted diseases (STDs) and compares them with the costs of using no method. The average annual cost per adolescent at risk of unintended pregnancy who uses no method is $1,267 ($1,079 for unintended pregnancy and $188 for STDs) in the private sector and $677 ($541 for unintended pregnancy and $137 for STDs) in the public sector under the most conservative assumptions. At one year of use, private-sector savings from adolescent contraceptive use range from $308 for the implant to $946 for the male condom; public-sector savings rise from $60 for the implant to $525 for the male condom. Both the use of male condoms with another method and the advance provision of backup emergency contraceptive pills provide additional savings.