Search PubMed⌕ Search

Biomedical subjects

J Troccaz

Publications and source records attributed to J Troccaz.

29 records · Page 2Linked to original sources

Computer assisted pericardial puncture: work in progress.

Until now, computer assisted surgery has focused primarily on surgical procedures involving rigid anatomical structures. Because soft tissues can be highly mobile and deformable, they may require specific imaging devices, suitable modeling tools, and guiding systems. Percutaneous pericardial puncture is a good clinical target for computer assisted surgery; this procedure is often performed without direct visualization and is dangerous even though echographic control is used. Computer assistance can greatly improve this technique and will allow accurate puncture of preplanned targets. This paper describes a new approach for computer assisted pericardial punctures (CASPER) and describes a first feasibility analysis of CASPER demonstrated with anesthetized animals. The approach is based on the use of echographic data localized in space, from which an optimal strategy is defined. Because of the specificity of the pericardial effusion, a stable target can be selected despite the heart motions. A passive guiding system is used. We have demonstrated the feasibility of the approach.

Animals↗

Computer assisted spine surgery.

When inserting screws into a vertebral pedicle, the surgeon usually exposes the back part of the vertebra and uses his or her anatomic knowledge to align the drill in the proper direction. A slight error in direction may result in an important error in the position of the tip of the screw. This is done with no direct visibility of crucial structures (spinal cord, pleura, vessels). Statistical analysis of a series of surgical procedures has shown that 10% to 40% of the screws are not installed correctly. To reduce the risk of complication, a computer assisted method is proposed that enables the surgeon to place a screw at a position preoperatively defined in 3 dimensions using computed tomography images. This allows the surgeon to align a standard surgical drill with the optimal position and direction. The depth of the pilot hole during drilling also is monitored by the system to prevent penetration of the anterior cortex of the vertebral body. Using this procedure, in vitro tests were performed and showed that an accuracy of less than 1 mm can be obtained. Clinical trials were done in 10 patients who suffered severe scoliosis or spondylolisthesis. The trajectory of the holes drilled in L2, L3, L4, and L5 vertebrae were checked for all clinical tests. Postoperative radiographs and computed tomography scans showed that the screws were well inserted in each plane for each pedicle. This technique also can be used to perform osteosynthesis at the thoracic and cervical levels.

Adult↗

Virtual echography. The simulation of ultrasonographic examination.

We present a Virtual Echographic System. Because this examination is particularly difficult, developing a simulator is very useful to give students some common databases of pathological samples on which they could experiment image acquisition and evaluate their understanding of clinical cases. We have applied our method to the simulation of thigh ultrasonographic examination for thrombosis diagnosis. A preliminary system, focusing on image generation, has been developed. Virtual echographic slices are generated using a particular interpolation technique and a deformation model of significant structures. Resulting images have a visual quality similar to usual ones.

Computer Simulation↗

Computer-assisted spine surgery: a technique for accurate transpedicular screw fixation using CT data and a 3-D optical localizer.

The computer-assisted spine surgery system presented in this paper follows the basic ideas which have been developed for computer-assisted medical interventions (CAMI) in our lab since 1985. There are three steps to insert a linear tool inside vertebral pedicles. First, the surgeon defines an optimal trajectory on pre-operative computed tomography. Second, this trajectory is reported in the operating room coordinate system using an intra-operative sensor and a registration algorithm. Third, a guiding system helps the surgeon follow the selected trajectory. In this paper, we present an implementation of this method that uses only a 3-dimensional optical localizer. Results on cadaver specimens and on the first seven patients are presented.

Bone Screws↗

Patient setup optimization for external conformal radiotherapy.

The aim of conformal radiotherapy is to deliver precisely a specific dose of radiation to a planning target volume, concurrently radiating as little healthy tissue and organs as possible. This can be accomplished only with the accurate positioning of the patient with respect to the radiotherapy system. In this paper, we describe a system to achieve a higher overall accuracy in the delivery of a prostatic radiation boost for treatment of carcinoma of the prostate. The system is based on the use of ultrasound images for measuring the actual position of the patient's prostate just before the radiation. Since these images are registered with pretreatment computed tomography or magnetic resonance imaging, the position and orientation of the planning target volume are computed with respect to the radiotherapy system and can be corrected as needed. This system is under clinical evaluation.

Computer Simulation↗

Building a hybrid patient's model for augmented reality in surgery: a registration problem.

In the field of Augmented Reality in Surgery, building a hybrid patient's model, i.e. merging all the data and systems available for a given application, is a difficult but crucial technical problem. The purpose is to merge all the data that constitute the patient model with the reality of the surgery, i.e. the surgical tools and feedback devices. In this paper, we first develop this concept, we show that this construction comes to a problem of registration between various sensor data, and we detail a general framework of registration. The state of the art in this domain is presented. Finally, we show results that we have obtained using a method which is based on the use of anatomical reference surfaces. We show that in many clinical cases, registration is only possible through the use of internal patient structures.

Algorithms↗

Conformal external radiotherapy of prostatic carcinoma: requirements and experimental results.

The aim of conformal radiotherapy is to deliver, with high precision, a specific dose (which may be a high dose) to a planning target volume, concurrently with irradiating as little as possible healthy tissue and organs at risk. Radiation therapy may suffer from a number of problems that result in both over- or under-sizing the irradiation fields, making over-rough simplifications of the irradiation ballistics and delivering an insufficient tumoral dose (to spare critical organs and reduce toxicity). One of these problems lies in the accurate positioning of the planning target volume with respect to the irradiation system, thence in the correct execution of the ballistics. In this paper, we describe a system aiming at achieving a higher overall accuracy in the delivery of prostatic boost for carcinoma of the prostate. The system is based on the use of ultrasonic images for measuring the actual position of the prostate just before irradiation. Since these images are registered with pre-operative (CT or MR) images, the position and orientation of the planning target volume is computed with respect to the irradiation system, and can be corrected accordingly. First experiments have been performed on dummies, and the results are discussed.

Humans↗

Pre- and intra-irradiation multimodal image registration: principles and first experiments.

Accurately repositioning the patient with respect to CT or MR images is essential for high precision radiotherapy. We show that portal images may be automatically registered with 3D pre-session data (typically morphological images like CT or MR images), thus enabling an automatic adjustment of the planned strategy to the actual position of the patient. Based on computer vision techniques, the principles of this new method of multimodal image registration are presented, and the first experiments with a phantom are analysed.

Humans↗