Search PubMed⌕ Search

Biomedical subjects

J Thouvenot

Publications and source records attributed to J Thouvenot.

At least 37 records · Page 2Linked to original sources

[Incidences of resistance capacity (RC) and of electrode-interval enlargement on the gastro-intestinal electrical activity of the awake dog (author's transl)].

By the use of differents resistance capacity (RC) values (0,3, 0,7, 1, 3, 6 and 7 s.) during bipolar recordings of digestive electromyogramme in chronically implanted dogs, it has been shown that the RC incidences were:--an increase of the slow wave potential amplitude, the optimale value of the RC was 3 sec;--the detection with long RC (1, 3, 6 and 7 S.) of a slow post-potential at the antral level. But there is no effect of the RC on the slow wave duration and on the spikes potentials caracteristics (amplitude-duration number). When the interval between the two active electrodes is increased (0,5 to 63 cm) the slow wave amplitude is enlarged; the best results on the slow wave amplitude are obtained with an electrode-interval of 7 to 8 cm. In cases of an important interval between two active electrodes (8, 16, 32, 63, 190 cm), the slow wave frequency at an intestinal level is dependent of the upward electrode. The spikes potentials are affected by electrode interval enlargement, and are dependent of the contractil events which can appear under each separated electrode.

Action Potentials↗

[Automatic analysis of gastrographies by means of optical digital equipment (author's transl)].

The present paper is concerned with problems of automatic analysis of radiograms, specially cinegastrographies. This study is connected with the utilisation of an interactive system including optical digitizer with its units of control and visualization. This system can explore the radiologic film in its current size of 30 X 40 cm. The particular interest of this application is extracting several parameters characterizing the size and the shape of the stomach. A middle axis can be extracted by computing, from this one a spatio-temporal diagram can be obtained. From this methodology of representation, several states of gastric motility could be characterized.

Analog-Digital Conversion↗

[Exploration of digestive electrophysiology using a new technic : electrointraperitoneography (EIG)].

A new and simple method, the electrointraperitoneography (E.I.G.) is described and used for the recording of the digestive motility in conscious dogs and in anesthetized rabbits and rats. With the E.I.G. method, we have found the two types of potentials which characterise the electrical activity of the small intestine : the basic electrical rhythm (B.E.R.) and the action potentials (spikes).

Anesthesia, General↗

[Experimental stomach cancerization in the rat].

Simulated gastric cancers in rats have been realised by implantation of walker tumour with three different methods. The best results are obtained with the injection of 0,1 ml of tumour cells suspension in the antral wall. With this method, no important trauma is done to the antral wall, and percentage of tumour implantation in antral wall is high (84%).

Animals↗