Search PubMed⌕ Search

Biomedical subjects

J Tall

Publications and source records attributed to J Tall.

2 recordsLinked to original sources

Lag phase quantification for solid gastric emptying studies.

UNLABELLED: This study compared the different calculation methods of the solid gastric emptying lag phase and evaluated the effect of the temporal sampling interval on the calculated value using the modified power exponential (MPE) method. METHODS: Twenty normal control subjects and 42 patients had anterior and posterior image acquisition on a multihead gamma camera, one frame per minute x 90. ROIs were selected for the stomach, gastric antrum and small bowel. Time-activity curves (TACs) were generated for anterior, posterior and geometric mean data. The lag phase was calculated using various methods such as transition point, starting index, first appearance of bowel activity (FABA), MPE and antral peak filling time. To determine the importance of the temporal sampling rate on the calculation of the lag phase by the MPE, intervals between 1 and 20 min were analyzed. RESULTS: The transition point, starting index and FABA correlated extremely high (r = > or = 0.92) in normal control subjects and patients. Normal lag phase values were mean 22-24 +/- 10 min for transition point, starting index and FABA compared with 47 +/- 18 min for the MPE method (p < 0.0001). The MPE correlated poorly with the other method (r = 0.74). Antral peak filling time correlated poorly (r = 0.47) with transition point, starting index and FABA, but somewhat better with the MPE (r = 0.70). Comparing 15-min versus 1-min sampling intervals using the MPE, 35% of subjects had values that differed by > or = 7.5 min and 10% had values differing by > or = 15 min. CONCLUSION: The lag phase calculated by the MPE correlated poorly with other methods, and its accuracy was limited by the rate of the temporal sampling. The transition point, starting index and FABA all highly correlated with each other; the latter is a particularly reliable physiological indicator and is easily quantified using a small-bowel TAC.

Adolescent↗

Diurnal rhythmicity and Air Force flight accidents due to pilot error.

In order to evaluate the possible role of an endogenous rhythmic factor in Air Force flight accidents a retrospective study was carried out. The study included all Air Force (aircraft) flying accidents which have been attributed to pilot's error and which occurred, in peace time missions, over a period of 12 years (1968-1980). The frequency of hourly accidents was computed separately, for each year, for each month, for each day of the week, and for each calendar day. Identical computations were carried out for the frequency of hourly flights. When the hourly ratios of these two parameters were computed, by dividing the value of one parameter to the other at each hour, a rhythmic (rather than constant) diurnal pattern was obtained. The pattern was defined as the "Hourly Accident Coefficient (HAC)". The HAC values ranged from 1.58 to 0.68 (pooled data for all surveyed aircrafts) and from 4.12 to 0.74 (data for fighter planes). The pattern, which exhibited a diurnal rhythm, was independent of the frequency of flights and appeared to be related to the sleep-wake cycle of the pilots, especially to the time of waking from the night sleep. The results are used as a directive for a progressive study aimed at evaluating the practical implications of the presented observations.

Accidents, Aviation↗