DNA analysis of peripheral blood mononuclear cells for early detection of hepatic graft rejection.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to J Taki.
Explore the source record for details and available documents.
High-resolution three-headed single photon emission computed tomography (SPET) equipped with fan-beam collimators was applied to myocardial perfusion imaging in infants aged from 1 to 11 months (n = 5). A tabletop designed specifically for infants was fixed on the SPET couch to reduce the radius of camera rotation to 13.2 cm. Significant improvement in resolution was achieved with the fan-beam collimators compared to parallel-hole high-resolution collimators. With the administration of approximately 37 MBq (26-44 MBq) 201Tl, 5 min acquisition time was possible for SPET imaging, which provided good image quality in all patients. Thus, a smaller administration dose is possible within a practical short acquisition time. High-resolution fan-beam SPET imaging can be a routine diagnostic method for heart disease in newborn babies and infants.
Characteristics of the myocardial distribution of 99mTc-MIBI and 99mTc-Teboroxime was compared with the myocardial distribution of 201Tl. We made summed myocardial images, in which central three short-axis SPECT slices were added. Rectangular region of interest (ROI) was set on each myocardial segment, and mean counts of each myocardial region was obtained using summed short-axis images. The ratio of inferior-to-anterior mean counts (I/A) was 0.69 +/- 0.20 in 99mTc-MIBI and 0.62 +/- 0.16 in 201Tl. The ratio of inferior-to-lateral mean counts was 0.70 +/- 0.18 and 0.65 +/- 0.13, respectively. Both ratios in 99mTc-MIBI were significantly higher than those in 201Tl (p less than 0.05). 201Tl to 99mTc-MIBI ratios of these two values were 1.11 +/- 0.17 (I/A) and 1.08 +/- 0.16 (I/L). The ratios of I/A and I/L of 99mTc-MIBI were about 10 percent higher than those of 201Tl. 99mTc-Teboroxime dynamic short-axis SPECT images of every three-minute were obtained. The ratios of counts in each wall were calculated similarly. After about 8 minutes, gradual increase in hepatic activity can be a cause of quantitative error in the assessment of SPECT images. We obtained the data with a human cardiac phantom. The myocardial phantom filled with 99mTc or 201Tl was placed in the mediastinal portion that is surrounded by the lung (saw dust) and vertebra (plastic bar). The ratio of I/A was 0.79 and I/L was 0.85 in 201Tl. The I/A ratio was 0.93 and I/L was 0.97 in 99mTc. Both ratios in 99mTc were about 15 percent higher than those in 201Tl.(ABSTRACT TRUNCATED AT 250 WORDS)
The response of left ventricular function during exercise and recovery after exercise was assessed in 35 patients with coronary artery bypass grafting before and after the operation by means of a continuous ventricular function monitor, which records serial beat-to-beat radionuclide data and calculates left ventricular ejection fractions every 20 seconds. The mean ejection fraction decreased with graded bicycle exercise from 48% +/- 9% to 41% +/- 11% (p less than 0.001) before operation but increased with exercise from 50% +/- 9% to 55% +/- 11% (p less than 0.001) after operation. Cardiac response was divided into four types with respect to the profiles of the ejection fractions during exercise. Type A continued to increase; type B initially increased but then decreased in late exercise stages; type C did not change significantly; type D continued to decrease. Most patients had type C or D responses before operation but type A after operation. Seven patients with occluded grafts or ungrafted coronary arteries had type B or D responses. Three patients with complete revascularization, including an internal thoracic artery and saphenous vein grafts, had type B responses. Three patients with extensive infarction and poor left ventricular function showed type C. In the early recovery period after exercise, most patients had an "overshoot" elevation of ejection fraction. The mean value increased from 59% +/- 10% before operation to 64% +/- 11% after operation (p less than 0.01). The recovery time after exercise was reduced from 2.8 minutes before operation to 1.8 minutes after operation (p less than 0.001). The continuous ventricular function monitor elucidated changes in left ventricular function both during exercise and recovery after exercise, as well as unmasking abnormalities in left ventricular function after coronary bypass operation.
Data acquisition in SPECT assumes that there is no change in radionuclide distribution during data collection. However, this assumption is not valid in radiopharmaceuticals with rapid temporal changes in radioactivity. Artifacts and quantitative errors are studied using phantom studies, mathematical models, and clinical myocardial data. Projection data of each model were sequentially multiplied by weighting coefficients that varied mono-exponentially with time, and the SPECT images were reconstructed. A long data acquisition time in comparison to the clearance of the tracer can be a significant cause of artifact. When the myocardial septum-to-lateral count ratio is used as an index of distortion, a shorter acquisition time than the effective half-life of the tracer is required to reduce the error of the septum-to-lateral count ratio to within 10%. Since 180 degrees rotation acquisition causes artifacts depending on the direction of rotation, 360 degrees acquisition is preferable. Continuous repetitive rotation acquisition is a suitable method for dynamic SPECT to reduce quantitative errors and artifacts.
99mTc teboroxime is a new myocardial imaging agent that has characteristics of high accumulation in the heart and rapid clearance. We performed tomographic teboroxime study and compared the findings with that of 201Tl. Myocardial teboroxime clearance was calculated by dynamic single photon emission computed tomography (SPECT) using continuous repetitive rotation acquisition method. Teboroxime SPECT image was reconstructed by the three-minute data started from 4 minutes after injection. In 45 myocardial regions (15 patients), complete agreement between 201Tl and 99mTc teboroxime was obtained in 33 regions (73%), when the findings were classified as normal, ischemia and infarction. Significant delay in clearance was seen in the region of coronary stenosis (greater than or equal to 75%) compared with that in the control region (p = 0.0087 at rest, and p = 0.0385 at peak exercise by paired T test). Septum-to-lateral ratios of the clearance and myocardial initial count showed positive correlation (r = 0.743). Further clinical application of this radiopharmaceutical is expected as a new myocardial imaging agent.
A continuous ventricular function monitor with a miniature cadmium telluride detector was evaluated and applied to patients with coronary bypass surgery (CABG). Ejection fraction (EF) at rest and change in EF from rest to exercise and postexercise (Y) measured with the device correlated with that of the gamma camera (X) (Y = 0.86x + 6.8(%), r = 0.87, n = 110, p less than 0.001, and Y = 0.96x + 0.4(%), r = 0.90, n = 37, p less than 0.001 respectively). Left ventricular function during and after supine ergometer exercise was monitored in 54 patients before and after CABG. The EF change from baseline to peak exercise improved from -5.9% +/- 8.9% before CABG to 7.2% +/- 7.9% after CABG (p less than 0.001). In all patients but two, a rapid EF increase just after exercise over baseline EF was observed. This EF "overshoot" during recovery increased from 11.5% +/- 6.5% to 16.4% +/- 6.0% (p less than 0.001) after CABG. The time from the cessation of exercise to EF overshoot decreased from 153 +/- 80 sec to 76 +/- 49 sec (p less than 0.001) after CABG. The continuous ventricular function monitor with a miniature cadmium telluride detector is able to measure EF reliably. Following successful aortocoronary bypass, EF response during exercise improved and the EF overshoot in the recovery phase became faster and higher.
Serial changes in left ventricular function during exercise were assessed by radionuclide continuous ventricular function monitoring in 80 patients undergoing coronary artery bypass surgery before and after operation. This monitor records serial beat by beat radionuclide and electrocardiographic data and calculates the left ventricular ejection fraction every 20s. The profiles of ejection fractions during graded bicycle exercise were divided into 4 types. In type A, the ejection fraction continued to increase. In type B, the ejection fraction initially increased but decreased in late exercise. In type C, the ejection fraction did not change. In type D, the ejection fraction continued to decrease. Type A is considered to be the normal response to exercise and types B, C and, D are considered to be abnormal responses. Before operation, 8 patients showed type A, 21 type B, 13 type C, and 38 type D. After operation, 53 patients showed type A, 16 type B, 8 type C, and 3 type D. The mean ejection fraction decreased with exercise from 53% +/- 11% to 47% +/- 11% before surgery, but increased with exercise from 55% +/- 10% to 64% +/- 14% after surgery. During postoperative exercise, no patient developed chest pain but 19 patients showed a decrease in the ejection fraction in early or late exercise. A decrease in the ejection fraction is an earlier indicator of myocardial ischaemia than angina or electrocardiographic changes. Silent left ventricular dysfunction during postoperative exercise was considered to reflect myocardial ischaemia resulting from occluded grafts, ungrafted coronary arteries, or inadequate perfusion by arterial grafts. The radionuclide continuous ventricular function monitor can detect silent left ventricular dysfunction after coronary artery bypass surgery.
201Tl SPECT was performed to detect mediastinal involvement in 80 patients with lung cancer who underwent surgery within a week after the SPECT study. Out of 29 patients with mediastinal involvement 16 (55%) were positive on the 201Tl early scan at 15 min postinjection and 22 (76%) were positive on the delayed scan at 3 h. These metastatic lymph nodes tended to be visualized much better on the delayed scan. In all patients with true positive results on the delayed scan, the mediastinal lymph nodes were plural, with a lesion of more than 14 mm in size. Seven false negative cases were found to have metastatic lesions less than 12 mm in size. Both the early and delayed scans showed false positive accumulation in six of 51 patients without mediastinal involvement (specificity 88%). Thus the overall accuracy for the delayed scan was 84%. The 201Tl delayed SPECT is thought to be a good noninvasive method for assessing mediastinal lymph node metastases from lung cancer.
Thallium-201 planar and SPECT studies were performed in 38 children with congenital heart disease using high-resolution three-headed SPECT. The 201Tl total or average right ventricular-to-left ventricular (RV/LV) count ratios were measured by summed short-axis images. In the planar study, the RV/LV systolic pressure ratio correlated with 201Tl RV/LV average count ratio (r = 0.91) better than that in the SPECT study (r = 0.78). However, in the SPECT study, patients with atrial septal defect (n = 9), ventricular septal defect (n = 13), tetralogy of Fallot and double outlet right ventricle (n = 6) showed a characteristic distribution in the plot of RV/LV pressure ratio versus 201Tl RV/LV total count ratio. A prospective study showed that the RV/LV average count ratio was a good predictor of RV/LV pressure ratio (n = 19, r = 0.91). Three-headed SPECT is useful for pediatric cardiac studies, and the overload types found in congenital heart disease seemed to be differentiated by the SPECT study.
A case of radiologically occult lung cancer is presented in which 201TI SPECT of the chest clearly delineated the involved area. A 66-yr-old man underwent chest screening examinations for asymptomatic smokers and presented a positive sputum cytology for lung cancer. Conventional chest x-ray, tomography of computed radiography, and a CT scan failed to locate the lesion in the lung. Thallium-201 SPECT, however, was successful in depicting the area of the involvement.
Cardiac response to exercise was evaluated with continuous ventricular function monitor (VEST) with cadmium telluride detector. Thirty-nine patients (30 male and 9 female, aged 57 +/- 8, 23 had old myocardial infarction) were monitored with VEST during and after supine ergometer exercise before and 4 weeks after coronary artery bypass grafting (CABG). Left ventricular ejection fraction (EF) responses were classified into 4 types; type A showed EF increase greater than 5% till end of exercise, type B demonstrated initial increase followed by decrease in EF, type C revealed no significant EF change, type D showed continuous EF decrease. Before CABG, each EF response type A, B, C, and D consisted of 4, 2, 12, 21 patients respectively and after CABG each type included 18, 10, 9, 2. The EF change from rest to peak exercise (delta EF-Ex) improved from -6.4 +/- 8.8% to 5.0 +/- 7.4% (p less than 0.001) after CABG. All patients showed rapid EF increase after exercise or "EF overshoot" (EF-OS). After CABG, the EF change from rest to EF-OS (delta EF-OS) and time to EF-OS (T-OS) were improved from 9.9 +/- 5.2% to 14.9 +/- 5.3% (p less than 0.001) and 162 +/- 86 sec to 80 +/- 48 sec (p less than 0.001) respectively. Type A, B patients showed higher delta EF-OS and shorter T-OS than type C, D patients, suggesting EF overshoot was contingent upon cardiac function during exercise. After CABG, in patients with myocardial infarction, T-OS shortened but delta EF-OS showed less improvement than patients without infarction, suggesting loss of myocardium hampered EF-OS.
Twenty-four-hour delayed imaging after stress thallium-201 scintigraphy was assessed for more accurate detection of viable myocardium. Thirty-two patients with coronary artery disease who showed fixed perfusion abnormality (FPA) at 3 hr imaging after stress Tl study were evaluated with 24 hr delayed imaging. Of 37 areas with FPA, 19 areas (51%) showed redistribution (RD) at 24 hr imaging. After successful coronary artery bypass grafting (n = 19) or transluminal coronary angioplasty (n = 3), stress Tl scintigraphy was performed. Of 13 areas with RD at 24 hr imaging, 12 revealed improvement of Tl uptake after revascularization. On the other hand, of 12 areas with FPA until 24 hr, 8 showed no improvement. In conclusion, conventional stress Tl-201 scintigraphy underestimates myocardial viability, and additional 24 hr imaging permits more accurate assessment of myocardial viability.
A radionuclide imaging with Tc-99m HMPAO labeled leukocyte was performed in order to determine its clinical usefulness in inflammatory disease. The mixed leukocyte isolated from 40 ml of whole blood containing 5 ml of acid citrate dextrose A and 7 ml of 6% hydroxyethyl starch was incubated with 370 MBq (10 mCi) of Tc-99m HMPAO at 37 degrees C for 30 minutes. Because the labeling efficiency of Tc-99m HMPAO labeled leukocyte was 60.2 +/- 6.3%, the procedure of washing Tc-99m, leukocyte with 5 ml of physiological saline was necessary before intravenous injection, in order to remove the unlabeled Tc-99m HMPAO. The recoveries of Tc-99m leukocyte in the blood after intravenous injection were 41.1 +/- 6.7% at 5 minutes, 33.4 +/- 2.1% at 30 minutes, and 27.2 +/- 3.4% at 2 hours after injection. Moreover, the labeled leukocyte was not stained with trypan blue. Therefore, the biological activity of the Tc-99m leukocyte was maintained as that of In-111 oxine labeled leukocyte. In the 39 patients with clinical suspicion of inflammatory disease including 15 patients with acute and chronic infectious disease where both Tc-99m leukocyte and Ga-67 citrate imagings were performed, the sensitivity, specificity and accuracy for infectious disease were 47%, 100% and 79% with Tc-99m leukocyte, and 67%, 79% and 74% with Ga-67 citrate. These results suggest that Tc-99m HMPAO labeled leukocyte imaging is promising for evaluating inflammatory disease because of the much higher specificity, the ready availability of Tc-99m HMPAO, the good image quality, and the lower radiation dose to the patient.
The reliability of a new ambulatory ventricular function monitor (VEST) with cadmium telluride (Cd-Te) detector was validated. No counting loss was observed under 20 kcps. In phantom study, more than 200 ml with 6 cm distance from the detector and more than 300 ml with 6-12 cm distance, underestimation of volume was observed. Ejection fraction (EF) calculated in phantom study showed close value to the true EF in 50-400 ml of end-diastolic volume. In 10 patients, 1-2 cm detector shift toward right upper, upper and left showed underestimation of EF. Good correlation of gamma camera EF (X) and VEST EF (Y) was obtained (Y = 0.96X + 3.6(%), n = 37, r = 0.93, p less than 0.001). EF change from rest values, obtained from each comparable exercise and post exercise stage by gamma camera (X) and VEST (Y), showed good correlation (Y = 0.95X + 0.8, n = 20, r = 0.85, p less than 0.001). In conclusion Cd-Te VEST was considered as a reliable EF measurement technique similar to gamma camera.
The sequential change of left ventricular function during exercise and recovery after exercise was assessed in 50 patients who had undergone coronary bypass surgery before and after the operation by means of continuous ventricular function monitoring system (VEST). Cardiac response was divided into 4 types with respect to the profiles of the left ventricular ejection fraction during exercise. Type A continued to increase; type B initially increased but decreased in severe exercise stages; type C did not change during exercise; type D continued to decrease. Most patients showed type C or D before surgery but showed type A after surgery. 9 patients with occluded grafts or ungrafted coronary arteries showed type B, C or D. Two patients with extended infarction and poor left ventricular function showed type C after surgery. In recovery period after exercise, the ejection fraction showed an overshoot. The mean ratio of peak ejection fraction during recovery to ejection fraction at rest increased from +62 +/- 12% before operation to +68 +/- 16% after operation (p less than 0.05). The recovery time after exercise was decreased from 195 sec before operation to 98 sec after operation (p less than 0.01). VEST revealed response of left ventricular function during exercise and recovery after exercise as far as detail abnormalities.
The response of left ventricular function during exercise and recovery after exercise was assessed in 52 patients with coronary artery bypass surgery by means of a radionuclide continuous ventricular function monitor. This system consists of 2 radionuclide detectors, recorder and a computer. After the equilibration of 20 mCi technetium 99m-labeled autologaous red blood cells into the intravascular space, the beat by beat radionuclide data were summed for 20-sec intervals to measure left ventricular ejection fraction (EF). Before surgery, the mean EF decreased with exercise from 51 +/- 9% to 45 +/- 11% (p less than 0.001). Cardiac response was divided into 4 types according to the profiles of the EFs during exercise. In 6 patients, EF continued to increase until maximal exercise (type A). In 10 patients, EF initially increased and then decreased in late exercise stages (type B). In 9 patients, EF did not change significantly during exercise (type C). In 27 patients, EF decreased throughout exercise (type D). After surgery, the mean EF increased with exercise from 53 +/- 10% to 60 +/- 13% (p less than 0.001). Thirty-five patients showed type A, 9 type B, 5 type C, and 3 type D. Two type D and 5 type B patients had occluded grafts or ungrafted coronary arteries. Four patients with complete revascularization including an internal thoracic artery and saphenous vein grafts showed type B. Three patients with extensive infarction and poor left ventricular function showed type C.(ABSTRACT TRUNCATED AT 250 WORDS)
Changes in ventricular function caused by activities of daily living, including standing, walking, stair climbing, and mental stress, were evaluated using a radionuclide device that recorded left ventricular function on a beat-by-beat basis. The ambulatory monitor was positioned over the patient's left ventricle after a gated blood pool scan. Monitoring revealed a 10% increase of left ventricular ejection fraction from baseline to brisk walking, an 18% increase during stair climbing, and a 6% increase with mental stress. In some subjects, however, the increase in ejection fraction during mental stress exceeded that during exercise.