Search PubMed⌕ Search

Biomedical subjects

J Taki

Publications and source records attributed to J Taki.

At least 37 records · Page 2Linked to original sources

[Improvement of 99mTc-pyrophosphate scintigraphy in detection of acute myocardial infarction: combined with 99mTc-tetrofosmin].

BACKGROUND: 201Tl and 99mTc-pyrophosphate (PYP) dual scintigraphy is daily used in the detection of acute myocardial infarction (AMI). However, 201Tl is not available on emergent situation. We proposed a new method for detection of AMI combined 99mTc-PYP with 99mTc-tetrofosmin (TF). METHODS: 99mTc-PYP (740 MBq) was administered to 25 patients with AMI, and 3.5 hours later, planar imaging (PYP planar) and SPECT were performed (PYP-SPECT). Immediately after cessation of PYP-SPECT, 99mTc-TF (370-740 MBq) was injected and 5 minutes later SPECT was performed in the same position (TF-SPECT). PYP-SPECT and TF-SPECT were reconstructed in the same geometric status to permit superimpose of PYP-SPECT and TF-SPECT images. Two experts and 2 beginners of nuclear medicine physician interpreted the images in three ways; PYP planar image only, PYP-SPECT, and PYP-SPECT with TF-SPECT. RESULTS: PYP-SPECT combined with TF-SPECT shows 100% detectability of the AMI lesions, which is significantly higher than other two methods in both experts and beginners. CONCLUSION: PYP-SPECT combined with TF-SPECT is a powerful method for detection of AMI.

Aged↗

Cardiac sympathetic activity in the asymmetrically hypertrophied septum in patients with hypertension or hypertrophic cardiomyopathy.

BACKGROUND: In patients with essential hypertension (HT), proportional (symmetric) left ventricular hypertrophy (LVH) is common. In contrast, hypertrophic cardiomyopathy (HCM) is characterized by disproportional LVH and, in particular, asymmetric septal hypertrophy (ASH); however, some hypertensive patients also develop ASH. It has not been determined whether such cases represent a distinct type of hypertensive LVH or HCM combined with hypertension. HYPOTHESIS: The study was undertaken to evaluate sympathetic activity in the interventricular septum in patients with HT and ASH or in patients with HCM. METHODS: The patients were evaluated by I-123 meta-iodobenzylguanidine (MIBG) and thallium-201 (201Tl) single-photon emission computed tomography (SPECT), respectively. They were divided into three groups: patients with essential HT and symmetric septal hypertrophy (Group A), patients with HT and ASH (Group B), and patients with HCM and ASH (Group C). RESULTS: Compared with the lateral wall, early uptake of MIBG in the septum was significantly higher in Group B than in Group A, but not significantly different between Groups A and C. Compared with the lateral wall, early uptake of 201Tl in the septum did not differ among the three groups. No significant difference in the MIBG clearance in the lateral wall was seen among the three groups. By contrast, MIBG clearances in the septum and apex were significantly greater in Group C than in Groups A and B. There was an inverse correlation between systolic thickening and MIBG clearance in the septum. CONCLUSION: These findings suggest that sympathetic activity in the septum differs between patients with HT and ASH and patients with HCM.

3-Iodobenzylguanidine↗

Gated SPET quantification of small hearts: mathematical simulation and clinical application.

Quantification of gated single-photon emission tomography (SPET) in small hearts has been considered to be inaccurate. To evaluate the validity of gated SPET in a small chamber volume, mathematical simulation and clinical application to paediatric patients were performed. Myocardium with various chamber sizes from 14 ml to 326 ml was generated assuming an arbitrary resolution (6.9-15.7 mm in full-width at half-maximum), noise and zooming factors. The cut-off frequency of the Butterworth filter for preprocessing was varied from 0.16 to 0.63 cycles/cm. The chamber volume was calculated by quantitative gated SPET software (QGS). The patients, aged 2 months to 19 years (n=27), were studied by gated technetium-99m methoxyisobutylisonitrile or tetrofosmin SPET. Image magnification as large as possible was performed during data acquisition to include the whole chest using 1.25-2.0 zooming. Based on the simulation study, an underestimation of the chamber volume occurred below a volume of 100 ml. The degree of underestimation for a 37-ml volume was 49% without zooming, but it improved to 3% with 2x zooming. Filters with a higher cut-off frequency, better system resolution and hardware zooming during acquisition improved quantitative accuracy in small hearts. For the subjects under 7 years old (n=7), quantification of volume and ejection fraction (EF) was possible in 72% of the patients. In those over 7 years old, gated SPET quantification was feasible in all cases. The correlation between gated SPET end-diastolic volume (SPET EDV) and both echocardiographic end-diastolic dimension (EDD) and echocardiographic EDV was good (r=0.84 between SPET EDV and echo EDD, r=0.85 between SPET EDV and echo EDV, P<0.0001 for both). The correlation between gated SPET EF and both echocardiographic fractional shortening (FS) and echocardiographic EF was fair (r=0.69 between SPET EF and echo FS, r=0.72 between SPET EF and echo EF, P<0.0001 for both). In conclusion, quantification of gated SPET of small hearts can be improved by means of a SPET filter with a high cut-off frequency, high system resolution and appropriate zooming. Gated SPET should be attempted not only in patients with small hearts but also in paediatric patients.

Adolescent↗

Peripheral sympathetic dysfunction in patients with Parkinson's disease without autonomic failure is heart selective and disease specific. taki@med.kanazawa-u.ac.jp.

UNLABELLED: The study was undertaken to investigate by means of iodine-123-labelled metaiodobenzylguanidine (MIBG) scintigraphy the peripheral sympathetic function in patients with Parkinson's disease (PD) without autonomic failure and in patients with related neurodegenerative diseases with parkinsonism. Seventy patients (33 men and 37 women, mean age 63+/-9.7 years) with parkinsonism and ten control subjects underwent MIBG scintigraphy. Of these 70 patients, 41 were diagnosed as having idiopathic PD, 9 multiple system atrophy (MSA), 6 progressive supranuclear palsy (PSP) and 2 corticobasal degeneration (CBD); the remaining 12 were diagnosed as having neurodegenerative disease with parkinsonism (P-nism) that did not meet the diagnostic criteria of any specific disease. Cardiac planar and tomographic imaging studies and subsequent whole-body imaging were performed 20 min and 3 h after the injection of 111 MBq MIBG. The early MIBG heart to mediastinum (H/M) ratio in PD (1.61+/-0.29) was significantly lower than that in the control group (2.24+/-0.14, P<0.01), P-nism (2.15+/-0.31, P<0.01), MSA (2.08+/-0.31, P<0.05) and PSP (2.30+/-0.24, P<0.01). The delayed H/M ratio in PD (1.47+/-0.34) was also significantly lower than that in the control group (2.37+/-0.14, P<0.01), P-nism (2.13+/-0.38, P<0.01), PSP (2.36+/-0.36, P<0.01) and MSA (2.17+/-0.36, P<0.01). In patients with PD, early and delayed H/M ratios were significantly decreased in disease stages I, II and III (established using the Hoehn and Yahr criteria) as compared with control subjects, and there were no significant differences among the stages. Only PD showed a significantly higher washout rate (WR) than that in the control subjects (27%+/-8.0% vs. 11%+/-4.2%, P<0.01). Early and delayed uptake ratios of the lung, parotid gland, thyroid gland, liver and femoral muscles in each of the patient groups were not significantly different from those in control subjects. Only the early and delayed uptake ratios of the lower leg muscles in MSA were significantly lower than those in the control group (P<0.05). IN CONCLUSION: In patients with PD without autonomic failure, only cardiac MIBG uptake was severely reduced in the earliest phase of the disease (stage I). Parkinsonian syndromes other than PD did not demonstrate significant reduction in MIBG uptake in any organs except for the lower legs in MSA. In patients with PD without autonomic failure, reduction in MIBG uptake occurs selectively in the heart; this is considered to be a specific finding for PD and useful for the differential diagnosis of the parkinsonian syndromes.

3-Iodobenzylguanidine↗

Left ventricular systolic dysfunction during exercise and dobutamine stress in patients with hypertrophic cardiomyopathy.

OBJECTIVES: We sought to characterize stress-induced left ventricular systolic dysfunction in patients with hypertrophic cardiomyopathy (HCM). BACKGROUND: Myocardial ischemia and diastolic dysfunction occur in patients with HCM. We hypothesized that, in the setting of transient myocardial ischemia, left ventricular systolic dysfunction occurs during exercise and dobutamine stress. METHODS: We studied 39 patients with HCM but without obstructive symptoms at rest or coronary artery disease. A continuous ventricular function monitor equipped with cadmium telluride detectors (VEST) was used to evaluate left ventricular function during supine bicycle ergometer exercise. Dobutamine stress echocardiography (DSE) was also performed. The left ventricular ejection fraction (LVEF) and regional wall motion were determined from echocardiographic images. RESULTS: Changes in the LVEF correlated between exercise and dobutamine stress (r = 0.643, p < 0.0001). The LVEF decreased more than 5% at peak exercise in 17 of patients (group II), while the other patients had normal responses (group I). New regional wall motion abnormalities during dobutamine infusion were detected in 18 of 110 (16.4%) segments in group I and 42 of 85 (49.4%) segments in group II. Decreased or unchanged regional wall motion occurred more frequently in hypertrophied segments than in nonhypertrophied segments (p < 0.0001). There were significant inverse correlations between the LVEF responses during both stresses and the number of abnormal segments noted during dobutamine stress in all patients (VEST: p < 0.005; DSE: p < 0.0005). Signs of left ventricular obstruction were observed in 11 of 39 patients during DSE. However, there was no significant correlation between the LVEF response and the dobutamine-induced left ventricular pressure gradient. CONCLUSIONS: Exercise-induced systolic dysfunction occurred in 50% of patients with HCM. In these patients, regional wall motion abnormalities were present in hypertrophied segments.

Adult↗

Exercise-induced ST-segment depression and systolic dysfunction in patients with nonobstructive hypertrophic cardiomyopathy.

BACKGROUND: ST-segment depression is common in patients with hypertrophic cardiomyopathy (HCM). However, it is not clear whether exercise-induced ST-segment depression in patients with HCM and patent coronary arteries is associated with changes in left ventricular function. METHODS: Left ventricular function was continuously evaluated in 53 patients with nonobstructive HCM during supine ergometer exercise with a radionuclide ventricular function monitor equipped with a cadmium telluride detector. On the basis of the ST-segment changes during exercise, the patients were divided into 2 groups: group N had no ST-segment depression, and group D had >/=0.1 mV ST-segment depression. RESULTS: Exercise duration, blood pressure, heart rate, and rate-pressure product during exercise did not differ between the 2 groups. End-diastolic volume at rest and at peak exercise did not differ between groups D and N. In contrast, the end-systolic volume in group N decreased during exercise, whereas in group D it increased. As a result, the left ventricular ejection fraction in group D decreased from 70% +/- 7% to 59% +/- 15% (P <.0001), whereas ejection fraction in group N increased from 65% +/- 8% to 71% +/- 11% (P =.0002). There was a strong correlation between exercise-induced ST-segment depression and changes in ejection fraction from rest to peak exercise (P <.0001). CONCLUSIONS: These results suggest that the exercise-induced ST-segment depression seen in patients with nonobstructive HCM is associated with systolic dysfunction during exercise.

Adolescent↗

Cardiac dysfunction and long-term prognosis in patients with nonobstructive hypertrophic cardiomyopathy and abnormal (123)I-15- (p-Iodophenyl)-3(R,S)-methylpentadecanoic acid myocardial scintigraphy.

To evaluate the relationship between myocardial scintigraphic abnormalities based on (123)I-radioiodinated 15-(p-iodophenyl)-3(R, S)-methylpentadecanoic acid (BMIPP) uptake and cardiac function and the relationship between these abnormalities and long-term prognosis in patients with hypertrophic cardiomyopathy (HCM), 27 patients with nonobstructive HCM underwent BMIPP myocardial scintigraphic study, echocardiography, and exercise radionuclide study. Based on the extent of BMIPP scintigraphic defects, the patients were divided into two groups: Group A (n = 19) patients had no or small defects, and group B (n = 8) patients had moderate to large defects. Cardiac events were recorded over an average period of 64 months. The left ventricular end-diastolic and end-systolic dimensions were significantly greater in group B than in group A. The fractional shortening in group B was less than in group A (p = 0.0002). The BMIPP score and fractional shortening at rest correlated significantly (p < 0.05). The BMIPP score and the change in ejection fraction between rest and peak exercise correlated significantly (p < 0.05). While only 1 cardiac event occurred in the 19 patients in group A during a mean follow-up period of 64 months, 6 cardiac events occurred in the 8 patients in group B. The 84-month event-free survival rate was 94.4% in group A and 14.6% in group B (p < 0.01). These results suggest that patients with HCM and moderate to large defects as assessed by BMIPP myocardial scintigraphy have decreased cardiac function and a poor prognosis.

Adult↗

[Measurement of myocardial blood flow increase rate at exercise with 99mTc-tetrofosmin radionuclide angiography].

UNLABELLED: We developed new method to calculate myocardial blood flow increase rate at exercise (MBF-IR) with 99mTc-tetrofosmin (TF) radionuclide (RN) angiography and myocardial perfusion SPECT and assessed its feasibility using clinical data. METHOD: Fifteen patients who were suspected to have coronary artery disease underwent TF RN angiography and SPECT at exercise and at rest. Seven patients had coronary stenosis and eight patients had no significant coronary stenosis in coronary angiography. MBF-IRs were calculated by the following equation: [formula: see text] where Cr = regional myocardial count at rest, Ce = regional myocardial count at exercise [formula: see text] = the area under ventricular time activity curve at rest and [formula: see text] = the area under ventricular time activity curve at exercise. RESULT: Rate pressure product (RPP) was similar in patients with and without coronary stenosis (24,509 +/- 6701.9 vs. 27,196 +/- 4862.4, p = 0.39). MBF-IR was 1.88 +/- 0.73 in the area covered by stenosed coronary artery, 2.53 +/- 0.75 in unstenosed coronary artery in patients who have significant coronary stenosis and 2.97 +/- 0.77 in normal coronary patients. MBF-IRs in the area covered by stenosed coronary arteries were significantly smaller than that of normal coronary artery patient (p = 0.037). Interobserver and intraobserber reproducibility were good (r = 0.96, 0.95 respectively). There was strong positive correlation between MBF-IR and RPP in normal patients (r = 0.69, p = 0.0018), suggesting MBF increase depends on the cardiac workload. CONCLUSION: MBF-IR can be estimated by the combination of TF RN angiography and SPECT at exercise and at rest.

Aged↗

[Nuclear medicine imaging for cardiomyopathy].

Nuclear medicine techniques have been applied to cardiomyopathy as well as in ischemic heart diseases. Various types of radiopharmaceutical including 201Tl and 99mTc-labeled perfusion tracers, 123I-labeled fatty acid(BMIPP), sympathetic function (MIBG) and tracers for myocardial injuries have been used. Perfusion imaging identifies stress-induced ischemia associated with myocardial damage. Recent application of gated SPECT enables simultaneous assessment of ventricular function. 123I-BMIPP and MIBG can detect metabolic abnormality, which has diagnostic and prognostic value for hypertrophic cardiomyopathy. The MIBG uptake index, heart-to-mediastinum ratio, is known to show good prognostic value for estimating dilated cardiomyopathy. Nuclear medicine plays unique roles for evaluating functional and metabolic derangement in cardiomyopathy.

Cardiomyopathy, Dilated↗

BMIPP compared with thallium redistribution.

I-123 labeled methyl-branched fatty acid, BMIPP, has been used mainly in Europe and Japan for the evaluation of various cardiac diseases. BMIPP uptake abnormality is usually more prominent tan perfusion, representing discordant BMIPP uptake less than thallium. This finding is observed in various cardiac disease conditions such as acute myocardial infarction, stable and unstable angina, hypertrophic and dilated cardiomyopathies. Many BMIPP studies combined stress thallium imaging in patients with coronary artery disease and hypertrophic cardiomyopathy demonstrated that such discordant BMIPP uptake less than thallium is related to stress-induced ischemia as evidenced by reversible thallium defect after exercise. BMIPP imaging is able to detect metabolic alteration in the heart which is not available by perfusion imaging alone.

Angina, Unstable↗

[Assessment of ECG-gated myocardial SPECT analysis program with cardiac phantom and clinical data].

PURPOSES: ECG-gated myocardial SPECT program (QGS) is coming into wide use. This program permits measurement of end-diastolic volume (EDV), and end-systolic volume (ESV) and ejection fraction (EF) by automatic detection of myocardial edges. We assessed the reproducibility, accuracy, factors that affect the measurement of these indices using a cardiac phantom and clinical data. METHODS: In the phantom study, we evaluated the effects of ventricular volume, location, absorption, acquisition time, enlarged acquisition and pre-filter on the calculated indices. In the clinical study using 99mTc-MIBI, reproducibility between 2 observers, comparison with left ventriculography and effects of pre-filter were assessed. In clinical cases of 201TI and 123I-BMIPP, left ventricular volume and EF were also analyzed by QGS with various pre-filters. RESULTS: Although the true phantom volumes (y) and calculated volumes (x) showed an excellent linear correlation (y = 0.94x - 13.8, r = 0.999), calculated volumes were significantly under-estimated by 14.5-33.8%. An absorbent material around the phantom caused reduction in calculated volumes by 4.1-9.1%. Duration of acquisition times, 3 to 60 seconds per projection, did not influence the calculation of the parameters. With enlarged data collection, calculated volume (37 ml) was larger than that of normal acquisition (33 ml). When the cut-off frequency of Butterworth filter was changed, these indices of volume and EF were almost stable over 0.41 cycle/cm. There was an excellent correlation in intra-observer measurements for EDV (r = 0.998, p < 0.0001), ESV (r = 0.998, p < 0.0001) and EF (r = 0.995, p < 0.0001). In comparison with left ventriculography, correlation of parameters was good in ESV (r = 0.91, p < 0.0001), EF (r = 0.88, p < 0.0001), but was fair in EDV (r = 0.78, p < 0.0001). The QGS program underestimated EDV, ESV and EF. CONCLUSION: QGS program with gated SPECT is useful to calculate relative volume and EF. However, to calculate absolute values, we should understand the various factors that affect the result of QGS.

Aged↗

[Assessment of regional myocardial function by ECG-gated myocardial SPECT].

PURPOSES: Regional myocardial functional parameters were assessed by ECG-gated myocardial SPECT analysis in normal subjects and ischemic heart diseases. METHODS: Normal subjects (13 male and 10 female) and 51 patients with chronic ischemic heart disease underwent ECG-gated myocardial SPECT. A dose of 740 MBq of 99mTc-MIBI was injected at rest, and gated SPECT was performed 60 min later. Wall motion (WM) and systolic wall thickening (WT), % tracer uptake were evaluated by quantitative gated SPECT program (QGS). Regional parameters were obtained in the 16 segments based on the functional polar map. In the normal group, standard values were evaluated in the lateral, septal, anterior and inferior regions both in male and female subjects. In the ischemic heart disease group, sensitivity and specificity of these parameters were assessed in each segment. To estimate the ability of WM and WT in detecting regional dysfunction, decreased perfusion area, which was defined as < mean - 2SD by the normal profile, was used as a standard. The receiver operating characteristics (ROC) area analysis was also performed. RESULT: In the normal profile, % tracer uptake was decreased in the anterior segments of female group, no significant difference was observed between male and female in WM and WT. WM was decreased in the septum and increased in the lateral segment. WT didn't show any difference regional difference. Sensitivity and specificity of WM were 56%/91% in the anterior, 0%/100% in the septum, 43%/87% in the inferior, 31%/85% in the lateral. WT were 67%/93% in the septum, 67%/79% in the inferior, and 59%/81% in the septum. The area under ROC curve was WM 0.63, WT 0.85 (p < 0.005 between WM and WT) in the septum, in inferior WM 0.77, WT 0.80 (p = 0.57), in anterior WM 0.86, WT 0.87 (p = 0.095), in lateral WM 0.68, WT 0.78 (p = 0.037). CONCLUSION: In normal profile, the % tracer uptake in the anterior wall decreased in females, but WM and WT did not show significant difference in each region affected this influence. The septal WM was decreased in the normal profile and ability to diagnose regional function was also decreased compared with WT. Thus, we can conclude that WT is preferable for detecting septal functional abnormality.

Aged↗

Preoperative assessment of residual hepatic functional reserve using 99mTc-DTPA-galactosyl-human serum albumin dynamic SPECT.

UNLABELLED: Preoperative assessment of residual hepatic functional reserve offers important strategic information for hepatic resection. To predict the postoperative residual liver function, we assessed the value of hepatic 99mTc-diethylenetriamine pentaacetic acid-galactosyl-human serum albumin (99mTc-GSA) clearance estimated by dynamic SPECT analysis. METHODS: We investigated 114 consecutive patients with liver disease, including 55 hepatectomy cases. One minute after injection of 185 MBq 99mTc-GSA, 15 serial dynamic SPECT images were obtained every minute. The initial five sets of SPECT images were analyzed by Patlak plot to estimate the sequential initial hepatic 99mTc-GSA clearance (mL/min) as an index of hepatic function. The sum of hepatic 99mTc-GSA clearance of the segments immune from resection was categorized as predicted residual 99mTC-GSA clearance. In the hepatectomy cases, scintigraphy was performed before and 37 +/- 10 d after the operation. RESULTS: Good correlation was observed between the total hepatic 99mTc-GSA clearance and conventional hepatic function tests: plasma retention rate of iodocyanine green (ICG) at 15 min (ICG R15), r = -0.600, P < 0.0001, n = 94; plasma disappearance rate of ICG (K ICG), r = 0.670, P < 0.0001, n = 83; cholinesterase, r = 0.539, P < 0.0001, n = 121; serum albumin, r = 0.421, P = 0.0001, n = 123; and hepaplastin test, r = 0.456, P < 0.0001, n = 120. There was good correlation between the predicted residual 99mTc-GSA clearance and the postoperative total hepatic 99mTc-GSA clearance in patients who underwent segmentectomy or lobectomy (r = 0.84, P < 0.0001, n = 28) and between the pre- and postoperative total hepatic 99mTc-GSA clearance in patients who underwent subsegmentectomy (r = 0.91, P < 0.0001, n = 25). Five patients who had postoperative complications due to hepatic insufficiency (2 patients died of postoperative hepatic failure within 2 mo after operation) showed significantly lower predicted residual 99mTc-GSA clearance compared with the patients without complications (90.3 +/- 37.2 versus 320.9 +/- 158.8 mL/min; P < 0.005). CONCLUSION: The total hepatic 99mTC-GSA clearance reflected hepatic function. In addition, preoperative predicted residual hepatic 99mTc-GSA clearance was a good indicator of postoperative hepatic function and early prognosis. 99mTc-GSA dynamic SPECT is assumed to be a useful method for determining the surgical strategy in patients with hepatic tumor and especially in patients with hepatic dysfunction.

Coloring Agents↗

Forward cardiac output measurement with first-pass technique using 99mTc-labeled myocardial perfusion imaging agents.

UNLABELLED: The aim of this study was to develop and validate a new first-pass method for the measurement of forward cardiac output (CO) using 99mTc-labeled myocardial perfusion imaging agents. METHODS: In protocol 1, to test the new method for measuring CO, the conventional method and the new method for CO measurement were performed in 1 d in 57 patients (32 men, 25 women; age 68 +/- 11 y). In the conventional method, radionuclide angiography (1 frame/s) with in vivo 99mTc labeling (110 MBq) of red blood cells was performed for 2 min in the left anterior oblique projection. Five minutes later, a 1-min equilibrium image was obtained, and a blood sample was taken for calculation of the distribution volume. To obtain data for the new method, further radionuclide angiography (1 frame/sec) with 99mTc labeling (600-740 MBq) of red blood cells was then performed in the anterior projection. CO was calculated using the following equation: CO = Cmax x V(LV)/integral of f(t)dt, where Cmax is the background-corrected peak count of the whole thorax during angiography, integral of f(t)dt is the area under the gamma variate-fitted left ventricular (LV) time-activity curve after background correction and V(LV) is the LV volume obtained by the area length method applied to the radionuclide angiography and myocardial tomography. In protocol 2, to evaluate the new method, 24 patients (16 men, 8 women; age 71 +/- 9.2 y) underwent radionuclide angiography with 99mTc-tetrofosmin (600-740 MBq), and the measured CO was compared with the CO obtained by the conventional method with 99mTc-labeled red blood cells. RESULTS: In protocol 1, good correlation was observed between the CO by the new method (Y) and the CO by the conventional method (X): Y = 1.0X + 57 mL/min and r = 0.95. There was good agreement between the two methods (mean difference -56 +/- 381 mL/min). Inter- and intraobserver correlation coefficients were 0.96 and 0.98, respectively. In protocol 2, the CO by the new method using 99mTc-tetrofosmin (Y) showed a good correlation with the CO by the conventional method (X): Y = 0.90X + 453 mL/min and r = 0.93. Good agreement between the two methods was observed (mean difference 73 +/- 390 mL/min). Inter- and intraobserver correlation coefficients were 0.95 and 0.98, respectively. CONCLUSION: This new method permits accurate forward CO measurement using the first-pass data with 99mTc-terofosmin, which is applicable to other 99mTc-labeled myocardial perfusion imaging agents.

Aged↗

[Assessment of regional quantitative analysis by ECG-gated myocardial SPECT after coronary artery bypass surgery].

PURPOSE: ECG-gated myocardial SPECT (G-SPECT) was performed before and after coronary artery bypass surgery (CABG) to investigate how this operation would affect the assessment of regional quantitative analyses. METHODS: Nineteen patients with coronary artery disease underwent G-SPECT before and 1 month after uncomplicated CABG. 99mTc-MIBI 740 MBq was injected at rest, then G-SPECT was performed 60 min later. Regional ejection fraction (rEF), wall motion (WM), systolic wall thickening (WT) and % tracer uptake were evaluated by quantitative gated SPECT program (QGS). Parameters were obtained quantitatively in 16 segments based on the functional bull's eye map. RESULTS: Percent tracer uptake increased in septum from 75 +/- 11% to 78 +/- 11% (p < 0.001), while WT did not change (40 +/- 19% to 41 +/- 20%) after CABG. However, in septum rEF decreased from 17 +/- 13% to 6 +/- 9% (p < 0.001) and WM decreased in septum from 1.6 +/- 1.1 mm to 0.6 +/- 0.9 mm (p < 0.001). CONCLUSION: Significant reduction of rEF and WM despite of no deterioration of WT and % tracer uptake suggested that rEF and WM were affected by pseudoparadoxical asynergy after uncomplicated CABG. For the evaluation of regional function after CABG by G-SPECT, WT might be the preferred parameter.

Aged↗

Value of iodine-123 metaiodobenzylguanidine scintigraphy in patients with vasospastic angina.

To assess the presence and location of presynaptic myocardial sympathetic abnormality in patients with vasospastic angina, iodine-123 labelled metaiodobenzylguanidine (MIBG) single-photon emission tomography (SPET) was performed. Fifty patients suspected of having vasospastic angina pectoris were enrolled in the study. All patients underwent a provocative test with intracoronary ergonovine infusion during coronary angiography, in which 99%-100% obstructive spasm was defined as a positive result. Twenty-five patients were diagnosed as having vasospastic angina based on a positive provocative test. MIBG SPET was performed at 20 min and 3 h after administration of 111 MBq or MIBG. On early images, only 5 of 25 patients with vasospastic angina showed a mild reduction in MIBG uptake, whereas 3-h delayed images demonstrated MIBG abnormality in 20 patients (80%). The location of the MIBG abnormality was completely or partially consistent with the spastic coronary territory in 18 patients. On the other hand, only 4 of 25 patients (16%) with negative provocative test demonstrated reduced MIBG uptake. Accordingly, positive and negative predictive values of MIBG SPET for the provocative test were 83% (20/24) and 81% (21/26) respectively. In conclusion, MIBG scintigraphy with SPET can permit the non-invasive detection and evaluation of suspected vasospastic angina.

3-Iodobenzylguanidine↗

Superiority of triple-detector single-photon emission tomography over single- and dual-detector systems in the minimization of motion artefacts.

A patient motion-related artefact is one of the most important artefacts in single-photon emission tomography (SPET) imaging. This study evaluated the effect of the number and configuration of SPET detectors on motion artefacts. The following acquisition conditions were simulated based on original 360 degrees projection images: (1) single-detector 180 degrees rotation (S180), (2) a dual-detector rectangular (L-shaped) 180 degrees acquisition (D180L), (3) dual-detector cameras mounted opposite each other with 360 degrees acquisition (D360) and (4) triple-detector 360 degrees acquisition (T360). The motion artefacts were introduced using a syringe and a myocardial phantom. Clinical cases with technetium-99m methoxyisobutylisonitrile and thallium-201 studies were analysed to confirm the validity of this phantom simulation. The effect of continuous alternate rotation acquisition and summing the projections on the reduction of motion artefacts was investigated in each model. The effect of motion depended on the number and the configuration of the SPET detectors. A 1-pixel (6.4 mm) motion in the S180, D180L and D360 models generated only slight artefacts, and a 2-pixel motion led to an apparent decrease in activity or created hot areas in the myocardium. On the other hand, a T360 rotation created few artefacts even with a 2-pixel motion of the last quarter of the projections. Despite the difference in attenuation with 201Tl and 99mTc, similar artefact patterns were observed with both radionuclides in selected patient model studies. Continuous alternate rotation could reduce artefacts caused by less than a 2-pixel motion. In conclusion, calculating the average of the sum of the projections of triple-detector 360 degrees rotations with alternate rotation is the best method to minimize motion artefacts. This "averaging" effect of motion artefacts is a key to this simulation.

Gamma Cameras↗

Effect of 360 degrees and 180 degrees rotation SPET acquisitions on myocardial polar map: comparison of 201Tl-, 99Tcm- and 123I-labelled radiopharmaceuticals.

Both 360 degrees and 180 degrees rotation acquisition methods have been used in myocardial single photon emission tomography (SPET) studies. We compared both methods using 201Tl, 99Tcm and 123I radiopharmaceuticals with phantoms and clinical models. Myocardial phantom studies with anterior and inferior defects were performed using 201Tl, 99Tcm and 123I. Clinical models of 14 typical situations, including normal subjects, patients with anterior or inferior defects and a high right hemi-diaphragm, were studied. The radiopharmaceuticals were 201Tl, 99Tcm-sestamibi, 123I-BMIPP and 123I-MIBG. Four sets of 180 degrees anterior rotation data with starting angles of (A) posterior, (B) LPO 30 degrees, (C) LPO 60 degrees and (D) left lateral direction were generated and compared with 360 degrees rotation SPET. A polar map display was used for quantification. In phantom studies, the defect contrast on the map was higher in the anterior defect with 180 degrees rotation than with 360 degrees rotation. However, it was decreased in the inferior defect, particularly with 201Tl, because of decreased wall activity around the defect. In the patient model with anterior or inferior defects, the defect contrast was improved with 180 degrees SPET by up to 10%. A slight decrease in the normal region was also noted in the 180 degrees reconstruction. The effect of diffuse liver activity on the inferior region depended on the rotation range. A patient with a high right hemi-diaphragm showed a lower inferior count with 360 degrees SPET. In conclusion, the 360 degrees acquisition was superior to the 180 degrees acquisition in the phantom with defects. Clinically, the quantitative differences in radionuclide types (99Tcm, 123I or 201Tl) were not significant for quantifying a moderate degree (50-60% of peak count) of defect. However, we note quantitative variation depending on the rotation range in the 180 degrees method.

3-Iodobenzylguanidine↗