Search PubMed⌕ Search

Biomedical subjects

J T Walker

Publications and source records attributed to J T Walker.

At least 19 recordsLinked to original sources

Surface decontamination of surgical instruments: an ongoing dilemma.

The issues of cross-infection and the survival of variant Creutzfeldt Jakob disease (vCJD) on surgical instruments have highlighted the importance of cleanliness of multiple-use surgical instruments. The aim of this study was to assess the levels of total protein contamination on a wide range of surgical instruments as an indication of the effectiveness of routine cleaning and disinfection in hospitals. Anonymized trays of wrapped and autoclaved instruments were supplied to two laboratories for analysis at the stage where they would normally be returned to operating theatres. Instruments were assessed for residual protein and total organic matter. Laboratory A showed that 17% (35/206) of instruments were above a threshold that equated to 200 microg. The worst examples, a McIvor gag, a Draffin rod (child) and a Yankaur sucker, had 1.028, 1.286 and 2.228 mg of extractable protein, respectively. The median (25th, 75th percentiles) amount of protein from instruments from different hospitals assessed in Laboratory B ranged from 8 (3, 30)mug (Hospital C) to 91 (35, 213) mug (Hospital D) (P=0.044). The residual matter washed from instruments varied from 0.62 (0.32, 0.81) mg (Hospital E) to 3.5 (3.5, 4.0) mg (Hospital A) (P=0.0001). In one case, 45 mg of residual organic matter was washed from an instrument (split stem). In conclusion, this study demonstrated that a proportion of instruments at the point of use show levels of protein that could pose a direct cross-infection risk via prion agents and other organic contamination that may reduce the effectiveness of cleaning/disinfection strategies targeted against either prions or traditional infectious agents.

Decontamination↗

Attitudes of general dental practitioners in Europe to the microbial risk associated with dental unit water systems.

UNLABELLED: Dental Unit Water Systems (DUWS) are used in dental practices to provide water for cooling of dental equipment and irrigation of the oral cavity. However, they have been demonstrated to be contaminated with micro-organisms. There are currently no European Union (EU) Commission guidelines for the microbial quality of water discharged by DUWS. This study was part of an EU research programme to investigate the microbial contamination of DUWS in general dental practice (GDP) in the UK, Denmark, Germany, The Netherlands, Ireland, Greece and Spain. OBJECTIVE: To undertake a questionnaire survey on the type of DUWS in use and determine the attitude of GDPs to the risk of microbial infection from DUWS. MATERIALS AND METHODS: The questionnaire was written and translated into the language of each country before being posted to each participating dentist. Dentists were asked to complete the questionnaire survey and return it by post. RESULTS AND CONCLUSIONS: The major findings were that the majority of dentists did not clean, disinfect or determine the microbial load of their DUWS, and that dentists would welcome regular monitoring and advice on maintaining their DUWS; the introduction of guidelines; and recommendations on controlling the microbial load of DUWS.

Attitude of Health Personnel↗

Comparison of the efficacies of disinfectants to control microbial contamination in dental unit water systems in general dental practices across the European Union.

Water delivered by dental unit water systems (DUWS) in general dental practices can harbor high numbers of bacteria, including opportunistic pathogens. Biofilms on tubing within DUWS provide a reservoir for microorganisms and should be controlled. This study compared disinfection products for their ability to meet the American Dental Association's guideline of <200 CFU x ml(-1) for DUWS water. Alpron, BioBlue, Dentosept, Oxygenal, Sanosil, Sterilex Ultra, and Ster4Spray were tested in DUWS (n = 134) in Denmark, Germany, Greece, Ireland, The Netherlands, Spain, and the United Kingdom. Weekly water samples were tested for total viable counts (TVCs) on yeast extract agar, and, where possible, the effects of products on established biofilm (TVCs) were measured. A 4- to 5-week baseline measurement period was followed by 6 to 8 weeks of disinfection (intermittent or continuous product application). DUWS water TVCs before disinfection ranged from 0 to 5.41 log CFU x ml(-1). Disinfectants achieved reductions in the median water TVC ranging from 0.69 (Ster4Spray) to 3.11 (Dentosept) log CFU x ml(-1), although occasional high values (up to 4.88 log CFU x ml(-1)) occurred with all products. Before treatment, 64% of all baseline samples exceeded American Dental Association guidelines, compared to only 17% following commencement of treatment; where tested, biofilm TVCs were reduced to below detectable levels. The antimicrobial efficacies of products varied (e.g., 91% of water samples from DUWS treated with Dentosept or Oxygenal met American Dental Association guidelines, compared to 60% of those treated with Ster4Spray). Overall, the continuously applied products performed better than those applied intermittently. The most effective products were Dentosept and Oxygenal, although Dentosept gave the most consistent and sustained antimicrobial effect over time.

Biofilms↗

Total viable counts, ATP, and endotoxin levels as potential markers of microbial contamination of dental unit water systems.

OBJECTIVES: To determine if either ATP or endotoxin concentrations in water supplied by dental unit water systems (DUWS) correlated with total viable counts (TVC), and therefore could be used as a rapid, chairside measure of levels of microbial contamination. DESIGN: A prospective trial. METHOD: Fifty-seven water samples were taken from the 'triple spray', air rotor and source water supplies from 25 dental units in eight practices. The samples were assayed for endotoxin concentration, total ATP and TVC. A pilot study was performed to assess the relationship between TVC and total cell counts, as determined by flow cytometry. RESULTS: ATP concentrations ranged from 22 to 958 relative light units (RLU) and free endotoxin ranged from 25 to 600 EU ml(-1). TVC varied from not detected to 2.16 x 10(4) CFU ml(-1). The ATP method proved to be a simple and rapid method that could be used at the chairside. However, there was no correlation between ATP or endotoxin concentrations and TVC in DUWS. TVC generally underestimated the total cell count by 50 to 500 fold. CONCLUSION: Half of the water samples from DUWS exceeded recommended levels of TVC. However, ATP and endotoxin concentrations in DUWS water samples did not correlate with these TVC data and therefore could not be recommended as an alternative assay to TVC for measuring bacterial contamination or for monitoring water treatment efficacy.

Adenosine Triphosphate↗

Microbiological evaluation of dental unit water systems in general dental practice in Europe.

A range of opportunistic pathogens have been associated with dental unit water systems (DUWS), particularly in the biofilms that can line the tubing. This study therefore aimed to assess the microbiology of DUWS and biofilms in general dental practices across seven European countries, including the United Kingdom (UK), Ireland (IRL), Greece (GR), Spain (ES), Germany (D), Denmark (DK) and the Netherlands (NL). Water supplied by 51% of 237 dental unit water lines exceeded current American Dental Association recommendations of < or = 200 colony-forming units (CFU) ml(-1). Microbiological loading of the source waters was between 0 (Denmark, the Netherlands and Spain) and 4.67 (IRL) log CFU ml(-1); water line samples from the DUWS ranged from 1.52 (ES) to 2.79 (GR) log CFU ml(-1); and biofilm counts ranged from 1.49 (GR) to 3.22 (DK) log CFU.cm(-2). Opportunistic pathogens such as legionellae (DK and ES), including Legionella pneumophila SG1 (DK and GR), and Mycobacterium spp. (DK, NL, GR, D and ES) were recovered occasionally. Presumptive oral streptococci (ES and NL), oral anaerobes (GR), Candida spp. (UK, NL and ES) and blood (GR and IRL) were detected at relatively low frequencies, but their presence indicated a failure of the 3-in-1 antiretraction valve, leading to back siphonage of oral fluids into the water and biofilm phase. These findings confirm that a substantial proportion of DUWS have high levels of microbial contamination, irrespective of country, type of equipment and source water. The study emphasizes the need for effective mechanisms to reduce the microbial burden within DUWS, and highlights the risk of occupational exposure and cross-infection in general dental practice.

Bacteria↗

Microbiological evaluation of a range of disinfectant products to control mixed-species biofilm contamination in a laboratory model of a dental unit water system.

Dental unit water system (DUWS) tubing harbors complex multispecies biofilms that are responsible for high microbial levels at the distal outlet. The aim of this study was to use an established biofilm laboratory model to simulate biofouling of DUWS to evaluate practical, cost-effective, and evidence-based methods of microbial decontamination. Reproducible biofilms were developed in the model over 14 days; decontamination was assessed using total viable counts (TVC) and microscopic-image analysis techniques to view the inner surface of tubing. Flushing did not reduce the biofilm coverage or TVC. Combizyme and ozone did not completely eliminate the viable bacteria (70 and 65% reduction in biofilm TVC, respectively), nor did they remove the biofilm (45 and 57% reduction in biofilm coverage, respectively). Chlorhexidine and Bio2000 (active agent: ethanol and chlorhexidine), Tegodor and Gigasept Rapid (aldehyde based), and Grotanol (hydroxide based) completely eliminated the TVC but did not completely remove biofilm (31, 53 33, 34, and 64.9% reduction of biofilm coverage, respectively). Other products including Grotanol Flussig (phenol based), Betadine (povidone-iodine based), Alpron (chlorite based), and the hydroxide-containing products Sporklenz, Sterilex Ultra, Dialox, Sterilox, Sanosil, Oxigenal, and Grotanat Bohrerbad resulted in a 100% reduction in the biofilm TVC and a >95% reduction in biofilm coverage. The study demonstrated that while many disinfectants achieve a sufficient reduction in TVC they may not necessarily remove unwanted biofilm from the tubing surfaces as tested in this laboratory-controlled biofilm model.

Bacteria↗

Hemoglobin adducts and sister chromatid exchanges in hospital workers exposed to ethylene oxide: effects of glutathione S-transferase T1 and M1 genotypes.

Ethylene oxide (EtO) is a genotoxic carcinogen with widespread uses as an industrial chemical intermediate and sterilant. We examined the effects of glutathione S-transferase T1 (GSTT1) and M1 (GSTM1) genotypes on the levels of N-(2-hydroxyethyl)valine (HEV) adducts in the erythrocytes and sister chromatid exchange (SCE) in lymphocytes from a group of 58 operators of sterilizers that used EtO and nonexposed workers from nine hospitals in the United States and one hospital in Mexico City. Cumulative exposure to EtO was estimated during the 4-month period before the collection of blood samples. Results showed that EtO exposure was significantly associated with the levels of HEV adducts and SCE after adjusting for cigarette smoking and other potential confounders. A significantly higher HEV adduct level (0.17 +/- 0.03 versus 0.08 +/- 0.01, mean +/- SE; P = 0.02) but lower SCE frequency (5.31 +/- 0.39 versus 6.21 +/- 0.17; P = 0.04) was observed in subjects with homozygous deletion of the GSTT1 gene (null genotype) as compared with those with at least one copy of the gene (positive genotype). In multiple regression analysis, the GSTT1-null genotype was associated with an increase in HEV adduct level (beta = 1.62; P = 0.02) and a decrease in SCE frequency (beta = -1.25; P = 0.003) after adjusting for age, gender, race, education, cigarette smoking, and EtO exposure status. The inverse SCE-GSTT1 relationship remained unchanged when SCE was further examined in relation to HEV adducts as an indicator of the internal EtO dose. The GSTM1 genotype was not associated with the level of either HEV adduct or SCE. These data indicate that the GSTT1-null genotype is associated with increased formation of EtO-hemoglobin adducts in relation to occupational EtO exposure, suggesting that individuals with homozygous deletion of the GSTT1 gene may be more susceptible to the genotoxic effects of ETO: The unexpected finding of decreased SCEs, which is less clear, may be attributed to the nonchemical specificity of this end point and the lack of expression of the GSTT1 enzyme in lymphocytes.

Adult↗

Validating the WWHLA growth model: a preliminary study utilizing serial height data of eight Zurich children.

In this study, we set out to validate the WWHLA growth model. We randomly selected eight children (four boys and four girls) who participated in the First Zurich Longitudinal Growth Study and fitted the model to their serial height growth data, using a computerized nonlinear least-squares technique. The results showed that the model provided an excellent fit to their data. The underlying trends of the height displacement, velocity, and acceleration curves were almost perfectly described, for the entire growth period from birth to maturity. The descriptive statistics obtained from fitting the model supported these results. In addition, student's t tests showed that all 14 model parameters differed from zero and were significant in describing the relationship between height and age in each child. From the growth curves of these children, we were able to easily discern and identify the six macroscopic growth processes (neonatal, infantile, early-childhood, mid-childhood, late-childhood, and pubertal) that were predicted by the model. The processes had properties that were similar to what we found in the earlier study. These are preliminary results, but they provide additional support for the WWHLA growth model and its use in describing linear growth curves in humans.

Body Height↗

Microbial aerosols in general dental practice.

OBJECTIVE: To measure the concentration of microbial aerosols in general dental practices and to use this information to carry out quantitative microbiological risk assessments. METHODOLOGY: Microbial air sampling was carried out continuously during 12 treatment sessions in 6 general dental practices in the South West of England. RESULTS: The microbial aerosol concentration in treatment rooms was generally less than 10(3) colony forming units per cubic metre of air (cfu x m(-3)). However, in 6 out of the 12 visits, at least one peak concentration with much higher numbers of bacteria was detected. The peak concentrations were associated with increased recoveries of presumptive oral streptococci suggesting these aerosols originated from the mouths of patients. These aerosol peaks dissipated within 30 minutes and no dissemination into waiting areas was detected. The peak concentrations were associated with mechanical scaling procedures (47% of procedures giving rise to a peak) and to a lesser extent by cavity preparation (11%). No aerosolised blood was detected. CONCLUSIONS: The data have been used to generate a framework for quantifying risk of exposure of staff to aerosolised microbial pathogens in general dental practice. For example, dentists and their assistants may have a slightly higher risk of exposure to Mycobacterium tuberculosis than the general public. The use of face seal masks that have been shown to protect against aerosolised micro-organisms may reduce this exposure.

Aerosols↗

Microbial biofilm formation and contamination of dental-unit water systems in general dental practice.

Dental-unit water systems (DUWS) harbor bacterial biofilms, which may serve as a haven for pathogens. The aim of this study was to investigate the microbial load of water from DUWS in general dental practices and the biofouling of DUWS tubing. Water and tube samples were taken from 55 dental surgeries in southwestern England. Contamination was determined by viable counts on environmentally selective, clinically selective, and pathogen-selective media, and biofouling was determined by using microscopic and image analysis techniques. Microbial loading ranged from 500 to 10(5) CFU. ml(-1); in 95% of DUWS water samples, it exceeded European Union drinking water guidelines and in 83% it exceeded American Dental Association DUWS standards. Among visible bacteria, 68% were viable by BacLight staining, but only 5% of this "viable by BacLight" fraction produced colonies on agar plates. Legionella pneumophila, Mycobacterium spp., Candida spp., and Pseudomonas spp. were detected in one, five, two, and nine different surgeries, respectively. Presumptive oral streptococci and Fusobacterium spp. were detected in four and one surgeries, respectively, suggesting back siphonage and failure of antiretraction devices. Hepatitis B virus was never detected. Decontamination strategies (5 of 55 surgeries) significantly reduced biofilm coverage but significantly increased microbial numbers in the water phase (in both cases, P < 0.05). Microbial loads were not significantly different in DUWS fed with soft, hard, deionized, or distilled water or in different DUWS (main, tank, or bottle fed). Microbiologically, no DUWS can be considered "cleaner" than others. DUWS deliver water to patients with microbial levels exceeding those considered safe for drinking water.

Bacteria↗

Efficacy of a contact lens cleaning device and its enhancement of the performance of contact lens care products.

BACKGROUND: Corneal infections due to contact lens contamination are risks associated with contact lens wear. Care systems which reduce these risks are desirable. METHODS: This study evaluated a contact lens cleaning device using normal saline initially and then four contact lens solutions. RESULTS: Using saline, six out of 10 tests resulted in complete removal of challenge organisms or showed reductions to 10 cfu/ml or <10 cfu/ml. Tests upon organism using multipurpose solutions showed >6 log reductions in 2-3 minutes. With laboratory made biofilms, similar results were obtained. CONCLUSIONS: This device improves lens cleaning and enhances lens care solutions. When used correctly it should lead to significant reductions in microbial keratitis associated with inadequate contact lens hygiene.

Bacteria↗

Cancer mortality among women employed in fast-growing U.S. occupations.

Our study examined cancer mortality before the age of 65 for women employed in the fastest growing and/or traditionally female occupations. Analysis of mortality data from 28 U.S. states for 1984-1995 revealed elevated proportionate cancer mortality ratios (PCMRs). The highest PCMRs observed were thyroid cancer among health aides, lymphatic and multiple myeloma among computer programmers, and brain cancer among actresses and directresses. Some of the excess mortality occurred for occupations that have been previously cited. These included elevated breast and ovarian cancer among teachers, Hodgkin's disease among hairdressers and cosmetologists, and thyroid cancer among health aides and therapists. A few of the associations were new, i.e., had not been previously observed. These included cancer of the connective tissue and lymphatic system among computer programmers, ovarian cancer and leukemia among secretaries, and lymphatic cancer and multiple myeloma among child care workers. These findings should be further investigated with epidemiologic and environmental studies.

Adult↗