Search PubMed⌕ Search

Biomedical subjects

J T Stewart

Publications and source records attributed to J T Stewart.

At least 73 records · Page 4Linked to original sources

Quantitation of promethazine enantiomers in human serum using a chiralcel OJ-R column and mixed-mode disc solid-phase extraction.

A liquid chromatographic method was developed for the assay of R(+)- and S(-)-promethazine enantiomers from human serum. The method involves the use of the mixed mode disc solid-phase extraction technique for sample clean-up. Chromatographic resolution of the enantiomers was performed on a reversed-phase cellulose-based chiral column (Chiralcel OJ-R) under isocratic conditions using a mobile phase consisting of 0.5 M aqueous sodium perchlorate/acetonitrile (63:37, v/v) at a flow rate of 0.5 ml min-1. Recoveries in the range of 97-99% at 20 ng ml-1 levels were obtained for both promethazine enantiomers. Intra-day and inter-day precision calculated as R.S.D.% was in the 3-8% ranges for both enantiomers. Intra-day and inter-day accuracy calculated as percent error was in the 0-10 and 1-7% ranges for both enantiomers, respectively. Linear calibration curves were obtained for each enantiomer in serum in the concentration range 5-90 ng ml-1. The limit of quantitation of each enantiomer was 10 ng ml-1. The detection limit for each enantiomer in serum using UV detection at 249 nm was 2 ng ml-1 (S/N = 2).

Anti-Allergic Agents↗

Supercritical fluid extraction of 13-cis retinoic acid and its photoisomers from selected pharmaceutical dosage forms.

13-Cis retinoic acid (Accutane) was extracted from a cream, gel, capsule and beadlet dosage from using supercritical carbon dioxide modified with 5% methanol as the mobile phase. The pump pressure and the extraction chamber and restrictor temperature were experimentally optimized at 325 atm and 45 degrees C, respectively. A 2.5-min static and 5-min dynamic extraction time were used. The supercritical fluid extraction (SFE) eluent was trapped in methanol, injected into the high-performance liquid chromatographic (HPLC) system, and quantitated by ultraviolet detection at 360 nm. Application of the SFE method to spiked placebo dosage forms gave 13-cis retinoic acid recoveries of 98.8, 98.9, 98.8 and 100% for the cream, gel, capsule and beadlet, respectively, with R.S.D.s in the range 0.6-0.9% (n = 4). Inter-day percent error and precision of the extraction were 1.1-2.0 and 0.2-2.4% (n = 3), respectively, and intra-day percent error and precision were 1.0-3.0 and 0.3-2.1% (n = 8), respectively. Percent error and precision data for spiked celite samples in the 0.05-1.0 microgram ml-1 range were 0.59-4.75 and 1.8-2.1% (n = 3), respectively. The extraction method was applied to commercial 13-cis retinoic acid dosage forms and the results compared to unextracted samples. Linear regression analysis of concentration versus peak height gave a correlation coefficient of 0.9991 with a slope of 7.468 and a y-intercept of 0.1923. The percent error and precision data were 1.3-5.3 and 0.2-1.5% (n = 4), respectively. The photoisomers of 13-cis retinoic acid were also extracted with the method and recoveries of 90.4-92.4% with R.S.D.s of 1.5-3.4% were obtained (n = 4).

Capsules↗

Stereoselective determination of apomorphine enantiomers in serum with a cellulose-based high-performance liquid chromatographic chiral column using solid-phase extraction and ultraviolet detection.

A novel and rapid method for the separation and determination of R-(-)- and S-(+)-enantiomers of apomorphine in serum by high-performance liquid chromatography with UV detection is reported. The method involved a solid-phase extraction of the R-(-)- and S-(+)-enantiomers of apomorphine and the internal standard R-(-)-propylnorapomorphine from serum using a C8 Bond-Elut column. The HPLC system consisted of a reversed-phase cellulose-based chiral column (Chiralcel OD-R, 250 x 4.6 mm I.D.) with a mobile phase of 35:65 (v/v) acetonitrile-0.05 M sodium perchlorate (pH 2.0, adjusted with 60-62% perchloric acid) at a flow-rate of 0.5 ml/min with UV detection at 273 nm. The detection and quantitation limits were 10 ng/ml for each enantiomer using 1 ml of serum. Linear calibration curves from 10 to 1000 ng/ml for both R-(-)- and S-(+)-enantiomers show coefficient of determination of more than 0.9995. Precision calculated as %R.S.D. and accuracy calculated as % error were 0.2-4.7 and 3.1-6.9%, respectively, for the R-(-)-enantiomer and 1.3-4.2 and 0.3-6.8%, respectively, for the S-(+)-enantiomer.

Animals↗

Stability of thiopental sodium and propofol in polypropylene syringes at 23 and 4 degrees C.

The stability of thiopental sodium and propofol in an admixture stored in polypropylene syringes at room temperature and under refrigeration was studied. Propofol injection 10 mg/ mL and thiopental sodium 25 mg/mL were mixed to final concentrations of 5 and 12.5 mg/mL, respectively. The admixture was put into 60-mL polypropylene syringes, and two syringes were stored at 23 degrees C and two at 4 degrees C. For solutions stored at 23 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, 240, and 264 hours, and for samples stored at 4 degrees C, samples were taken at 0, 4, 8, 24, 48, 72, 120, 168, 216, and 312 hours. Drug concentrations were determined by high-performance liquid chromatography. Thiopental sodium and propofol retained > 90% of their initial concentrations for up to 312 hours at 4 degrees C. At 23 degrees C, > 90% of the initial concentration was retained by propofol for up to 120 hours and by thiopental sodium for up to 240 hours. No visual changes or significant change in pH occurred in any sample. When mixed and stored in polypropylene syringes, propofol 5 mg/mL and thiopental sodium 12.5 mg/mL were stable for up to 312 hours at 4 degrees C and for up to 120 hours at 23 degrees C.

Anesthetics, Intravenous↗

Determination of fenbufen and its metabolites in serum by reversed-phase high-performance liquid chromatography using solid-phase extraction and on-line post-column ultraviolet irradiation and fluorescence detection.

An improved analytical method for the detection and quantification of fenbufen and its two major metabolites is described. The assay consists of reversed-phase high-performance liquid chromatography and post-column irradiation with ultraviolet light and fluorescence detection. A highly selective chromatography separation was established on a cyanopropyl column at ambient temperature with a flow-rate of 0.5 ml/min. The analytes of interest were isolated from serum using a Bond-Elut CIN column with high recovery and selectivity. The fluorescence response of all three analytes upon UV irradiation was investigated. The post-column UV irradiation was optimized and the effect of irradiation time on the fluorescence response was determined for all three analytes. The detection limits were 10 ng/ml for each analyte using 1 ml of serum. Linear calibration curves from 50 to 375 ng/ml for all three analytes show coefficients of determination of 0.99. Precision and accuracy of the method were within 3.9-6.5 and 5.1-7.4% for fenbufen, 3.5-6.4 and 4.9-6.3% for metabolite II (expressed as lactone III) and 5.4-7.4 and 2.6-7.4% for metabolite IV, respectively.

Anti-Inflammatory Agents, Non-Steroidal↗

Stereoselective determination of R(-)- and S(+)-prilocaine in human serum using a brush-type chiral stationary phase, solid-phase extraction and UV detection.

A chiral HPLC method was developed for the quantitation of R(-)- and S(+)-prilocaine in human serum. The method involves sensitive and selective detection of R(-)- and S(+)-prilocaine using normal-phase chiral HPLC on a pirkle-type naphthyl ethylamine stationary phase (Sumichiral OA-4700, 250 mm x 4 mm i.d.) at ambient temperature with a flow rate of 0.8 ml min-1. A sample clean-up procedure was used for isolation of the analytes of interest from human serum using Bond-Elut C18 columns with high recovery and selectivity. The detection limits were 4 ng ml-1 for R-prilocaine and 5 ng ml-1 for S-prilocaine. The limits of quantitation were 10 ng ml-1 for both enantiomers. Linear calibration curves in the 10-1000 ng ml-1 range showed good coefficients of determination > 0.999 (n = 3). Precision and accuracy of the method were within 4-5.8% and 1.5-4.8% respectively for R(-)-prilocaine, and 2.8-5.7% and 3.2-5.2% respectively for S(+)-prilocaine.

Anesthetics, Local↗

Determination of sulindac and its metabolites in human serum by reversed-phase high-performance liquid chromatography using on-line post-column ultraviolet irradiation and fluorescence detection.

On irradiation with ultraviolet light, the antiinflammatory agent sulindac and its two metabolites sulindac sulfone and sulindac sulfide form highly fluorescent derivatives. This reaction was exploited for the sensitive and selective detection of these compounds in serum using reversed-phase high-performance liquid chromatography on a Ultrasphere octylsilane column (150 x 4.6 mm I.D.) at ambient temperature with a flow-rate of 0.5 ml/min. The analytes of interest were isolated from serum using a Bond-Elut C2 column with satisfactory recovery and selectivity. The detection limits were 10 ng/ml for each of the three analytes using 1 ml of serum and the limit of quantitation was 50 ng/ml. Linear calibration curves from 50 to 1000 ng/ml for all three analytes show coefficients of determination of 0.9999. The post-column ultraviolet irradiation was optimized and the effect of irradiation time on the fluorescence response was determined for all three analytes. Precision and accuracy of the method were 0.4-5.6 and 1.6-4.5% for sulindac, 2.3-5.6 and 1.4-5.3% for sulindac sulfone and 2.5-4.3 and 0.8-2.8% for sulindac sulfide, respectively.

Anti-Inflammatory Agents, Non-Steroidal↗

Determination of metronidazole in vaginal tissue by high-performance liquid chromatography using solid-phase extraction.

A sensitive high-performance liquid chromatographic (HPLC) method for the determination of metronidazole in vaginal tissue is reported. The method uses a Zorbax SB phenyl column with a 0.01 M aqueous monobasic potassium phosphate buffer (pH 4.0)-absolute methanol (85:15, v/v) as mobile phase at a flow-rate of 1.0 ml/min and detection at 313 nm. Tinidazole was used as the internal standard. The method employed homogenization of tissue followed by solid-phase extraction. The quantitation was achieved within 30 min with sensitivity in the ng/g range. Metronidazole was linear in the 100-2000 ng/g range. The accuracy and precision were in the 1-4% range for the drug and the limit of detection was approximately 100 ng/g based on a signal-to-noise ratio of 3 and a 1009-microliters injection.

Animals↗

High-performance liquid chromatographic analysis of pindolol enantiomers in human serum and urine using a reversed-phase cellulose-based chiral column.

Simple, sensitive and reliable high-performance liquid chromatographic methods are reported for the determination of pindolol enantiomers in human serum and urine. The methods involved a solid-phase extraction of serum and a direct injection of urine samples. The separation of R(+)- and S(-)-pindolol was accomplished on a reversed-phase cellulose-based chiral column with a mobile phase of 40:60 (v/v) acetonitrile-0.3 M aqueous sodium perchlorate at a flow-rate of 0.5 ml/min. The detection was achieved by monitoring the fluorescence emission of pindolol enantiomers at 310 nm with excitation at 270 nm. The limits of detection were 1.2 ng/ml of R(+)- and 4.3 ng/ml of S(-)-pindolol in serum, and 21 ng/ml of R(+)- and 76 ng/ml of S(-)-pindolol in urine. The external standard method was used for quantitation. The methods have been applied to the analysis of human serum and urine samples in a pharmacokinetic study.

Adrenergic beta-Antagonists↗

Acute changes in atrial natriuretic peptide, insulin-like growth factor-1, and lactate levels during left anterior descending coronary artery angioplasty.

This study examines acute changes in circulating levels of atrial natriuretic peptide (ANP) and insulin-like growth factor (IGF-1) during short periods of myocardial ischemia experienced at coronary angioplasty. Ten patients (mean age 55.7 +/- 3.9 years, nine men) undergoing angioplasty to the left anterior descending coronary artery were studied. Angioplasty of the left anterior descending coronary artery was performed with the balloon inflations maintained at 6 to 10 atm for 20 to 90 seconds. Blood was sampled from the coronary sinus for ANP, IGF-1 (both total and free), and lactate levels at (1) after catheterization of the coronary sinus, (2) after the initial left coronary angiography, (3) immediately after balloon deflation, and (4) 5 minutes after deflation. ANP levels (pmol/L +/- SEM) rose significantly at the end of balloon deflation (13.4 +/- 2.8; p < 0.01) compared with baseline levels (8.8 +/- 1.9). This rise was sustained for at least 5 minutes after balloon deflation (13.7 +/- 3.1; p < 0.01). ANP levels were not affected by the injections of angiographic contrast media. Free IGF-1 levels rose after injections of radiographic contrast but not after balloon inflation or deflation. Total IGF-1 levels did not change significantly at any of the sampling times. Lactic acid (mmol/L) levels rose at the end of balloon inflation (2.66 +/- 0.6) compared with baseline (2.13 +/- 0.7; p < 0.05) but returned to normal within 5 minutes of balloon deflation. Neither lactic acid levels nor release of ANP or IGF-1 correlated with the initial left ventricular end-diastolic pressure or the degree of electrocardiographic ST depression during the procedure.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

A liquid chromatographic method for the determination of promethazine enantiomers in human urine and serum using solid-phase extraction and fluorescence detection.

A LC method was developed for the concurrent assay of R(+) and S(-) promethazine from human urine and serum. The method involves the use of solid-phase extraction for sample clean-up. Chromatographic resolution of the enantiomers was performed under isocratic conditions using a mobile phase of hexane-1,2-dichlorethane-absolute ethanol-trifluoroacetic acid (400:150:100:1, v/v/v/v) at a flow rate of 1 ml min-1 on a brush-type column KK-CARNU. The enantiomers were detected by fluorescence using an excitation wavelength of 250 nm and a 280 nm emission cutoff filter. Chlorpromazine was used as the internal standard for urine analysis. Standard addition was used for promethazine analysis from serum. Drug to internal standard ratios were linear from 0.25 to 10 micrograms ml-1 in urine. Serum levels were linear from 2 to 10 ng ml-1.

Chlorpromazine↗

A supercritical fluid chromatographic method using packed columns for phenylbutazone and oxyphenbutazone in serum, and for phenylbutazone in a dosage form.

The separation of phenylbutazone (PB) and its major metabolite oxyphenbutazone (OPB) using supercritical fluid chromatography (SFC) has been investigated. The separations were studied on octadecylsilane, silica and cyano packed columns with 5% methanol in carbon dioxide as mobile phase and detection at 240 nm. The octadecylsilane column showed the most favourable chromatographic parameters for the analysis of the analytes. Recoveries of PB and OPB from spiked human serum were in the 82-83% range using solid phase extraction on an ODS cartridge. Limits of detection of the SFC assay were 0.1 microgram ml-1 for PB and 1.0 microgram ml-1 for OPB. Accuracy and precision of the method were in the 0.24-4.94% range for PB and OPB. The SFC method was directly comparable to an HPLC assay of the same analytes. The SFC method was also applied to a commercial 100 mg dosage form of PB with good recovery of PB.

Capsules↗