Search PubMed⌕ Search

Biomedical subjects

J T Payne

Publications and source records attributed to J T Payne.

At least 37 records · Page 2Linked to original sources

Transcutaneous oxygen monitoring for predicting skin viability in dogs.

Transcutaneous oxygen (PO2-TC) monitoring is commonly used in human medicine for evaluating skin viability. The application of transcutaneous monitoring for evaluating skin viability in dogs was investigated. The changes in PO2-TC values were measured from 16 avascular skin flaps created along the lateral hemithoraces of 4 dogs. Transcutaneous oxygen values were serially recorded from the vascular base and avascular apex of each flap for 12 hours after surgery. A single transcutaneous measurement was obtained from each flap base and apex 24 hours after surgery. Serial arterial blood gas analyses were obtained to compare central oxygen values with PO2-TC values. Full-thickness skin biopsy specimens were harvested from the base and apex of each flap 24 hours after surgery. The flaps were observed for 4 days and then excised for histologic examination. A subjective grading scale was used to assess histologic changes. Throughout the 12-hour period and at 24 hours, a statistically significant difference was found between the PO2-TC values for apices and bases of the flaps. The mean PO2-TC for all bases was 90.9 mm of Hg +/- 3.3 SEM, and the mean PO2-TC for all apices was 21.2 mm of Hg +/- 1.8 SEM. The mean regional perfusion index (apex PO2-TC/base PO2-TC) was 0.23 +/- 0.02. The subjective numbers assigned to the biopsy specimens were statistically evaluated by using a paired Student's t test and a Wilcoxon signed-rank test. A significant difference was found between the numbers for the collective bases and apices with both tests.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Evaluation of skin viability in dogs, using transcutaneous carbon dioxide and sensor current monitoring.

Transcutaneous oxygen monitoring is commonly used in human beings to assess skin viability. Little attention has been directed toward the use of transcutaneous carbon dioxide (PCO2-TC) monitoring for the same purpose. The application of PCO2-TC monitoring for evaluating skin viability in dogs was investigated. The changes in PCO2-TC and local power reference (LPR) values were measured from 16 skin flaps created along the lateral hemithoraces of 4 dogs. Transcutaneous PCO2 and LPR values were serially recorded from the base and apex of each flap for 12 hours. A single measurement was obtained from each flap base and apex 24 hours after surgery. Arterial blood gas analyses were obtained to compare central PCO2 values with peripheral skin PCO2 values. The flaps were observed for 4 days and then harvested for histologic examination. Full-thickness skin biopsy specimens were obtained 24 hours after surgery and when the flaps were harvested to evaluate the viability of the apex and base of the flaps. A subjective grade was assigned to all skin biopsy specimens during histologic examination. For all measurements, a significant difference was found between the PCO2-TC values for apices and bases of the flaps. The mean PCO2-TC for all bases was 52.66 mm of Hg +/- 2.24 (SEM), and the mean PCO2-TC for all apices was 106.4 mm of Hg +/- 2.44. The regional carbon dioxide index (apex PCO2-TC/base PCO2-TC) was 2.02. A significant difference was not found between the LPR values for bases and apices.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Evaluation of the caudoventral portion of the mandible as a donor site for corticocancellous bone for periodontal surgery in dogs.

Corticocancellous bone graft was obtained from the caudoventral portion of the mandible of 8 dogs. The recipient site was an alveolar jugal and alveolar defect from vital root amputation of the mesiobuccal root of the maxillary fourth premolar. Anatomic observations of 20 canine cadavers indicated that guidelines for harvesting bone from the caudoventral portion of the mandible of dogs were the mesial aspect of the masseteric fossa, the distal aspect of the roots of the first mandibular molar, and the ventral aspect of the mandibular canal. The mean weight of corticocancellous bone harvested was 0.4 +/- 0.1 g. Harvested corticocancellous bone was adequate to fill recipient sites measuring a mean volume of 105.0 +/- 28.5 mm3. Histologic evaluation of the recipient site revealed progressive osseous integration of the bone-graft site during a mean follow-up period of 3.5 +/- 1.9 months. There was normal bone healing of the donor site without adverse effects on the mandibular molars or neurovascular structures of the mandibular canal. Vital amputation sites receiving silver amalgam had evidence of plasmacytic/lymphocytic inflammation associated with residual silver amalgam in the bone-graft area. The caudoventral portion of the mandible may be used as a donor site for autogenous corticocancellous bone in periodontal surgery of dogs.

Animals↗

Escherichia coli bacteremia associated with hypertrophic osteodystrophy in a dog.

Escherichia coli bacteremia was detected in a dog that had hypertrophic osteodystrophy. The dog improved after treatment with cephalothin sodium, iv fluid therapy, and cage rest. The cause of hypertrophic dystrophy has not been determined, although an infectious cause has been suggested. Dogs that are suspected of having hypertrophic osteodystrophy should be monitored closely for evidence of septicemia, and the administration of prophylactic antibiotics may be advisable.

Animals↗

Thoracolumbar vertebral osteochondroma in a young dog.

Osteosarcoma was diagnosed in a 7-month-old female German Shepherd Dog with hind limb paresis. Radiography revealed a circumscribed calcified mass in the dorsal vertebral lamina at T13-L1 resulting in extradural compression of the spinal cord. Surgical excision of the mass resulted in gradual return to normal neurologic function. Four weeks after surgery, the dog became severely atactic after rolling onto its back. A chip fracture of T13 was identified, and the dog was euthanatized at the owners' request.

Animals↗

Effect of left hepatic vein ligation on hepatic circulation, function, and microanatomy in dogs.

Eighteen healthy dogs were allotted to 3 groups (n = 6 dogs each). All dogs were evaluated at the beginning of the study by complete physical examination; total and differential WBC counts; serum biochemical analysis (alanine transaminase and alkaline phosphatase activities and bilirubin and albumin concentrations); sulfobromophthalein excretion, ammonia tolerance, and glucagon response testing; portal and intraparenchymal pressure determinations; operative mesenteric portography; and histologic assessment of hepatic biopsy specimens. The left hepatic vein was ligated completely in dogs of groups 1 and 2. Group-3 (control) dogs had a ligature placed loosely around the left hepatic vein. Dogs of groups 1 and 3 were reevaluated 24 hours after surgery by use of the aforementioned hematologic and biochemical tests. Group-1 dogs were reevaluated by use of portal and intraparenchymal pressure determinations, jejunal vein portography, and complete necropsy at 48 hours after surgery. At 4 weeks after surgery, dogs of groups 2 and 3 were reevaluated by use of all aforementioned tests. Results indicated transient hepatic congestion, which resolved by the fourth postoperative week. Longstanding effect on hepatic structure, circulation, or function was not found. We concluded that left hepatic vein ligation in clinically normal dogs does not cause severe or permanent liver damage.

Alanine Transaminase↗

Axial pattern flap based on the caudal auricular artery in dogs.

An axial pattern flap that was based on the sternocleidomastoideus branches of the caudal auricular artery and vein was developed. Control flaps, which included ligation and division of the caudal auricular artery and vein, were similarly developed on the contralateral aspect of the neck. Mean survival of caudal auricular artery axial pattern flaps (85.2%), compared with control flaps (63.9%), was significantly different (P less than 0.05). On the basis of results of this study, an axial pattern flap based on the sternocleidomastoideus branches of the caudal auricular artery and vein may be a source of skin for reconstructive procedures of the head and neck.

Animals↗

Bone healing.

Bone is a tissue composed of organic (cells and matrix) and inorganic (mineral) components. When the mechanical strength of bone is exceeded, fracture occurs. Healing progresses through inflammatory, reparative, and remodeling phases similar to other tissues, but, unlike other tissues, bone possesses the unique capability to completely regenerate and return to pre-injury strength. The bone healing process is influenced by many factors, including mechanical stress, biochemical mediators, bioelectric and piezoelectric properties, and neural and endocrine influences. In short, any factor capable of altering the metabolism of osteogenic cells can influence bone healing.

Animals↗

Predicting brain tumor histology: change of effective atomic number with contrast enhancement.

Thirty-eight enhancing intracranial neoplasms were evaluated with a dual kilovoltage technique to measure the change of effective atomic number (delta Z), and linear attenuation coefficients with the use of iodinated contrast material. The change of effective atomic number was found to separate intracranial neoplasms into three major groups: gliomas, meningiomas, and metastases. Other parameters, including linear attenuation coefficients and CT numbers, varied from less accurate to inaccurate. The change of effective atomic number with contrast enhancement not only predicted the appropriate histologic group of the neoplasm, but also aided in the differential diagnosis of neoplasms without a characteristic delta Z value.

Adult↗

Protocol for a computed tomography scanner performance repository.

An argument is presented for organization of a Computed Tomography Scanner Performance Repository. Performance data on CT scanners would be distributed in statistical form to the radiological community. A Protocol is presented for the uniform collection of data. Results of exposure, resolution and visibility measurements made by the authors are presented for the EMI 5005/U, Pfizer 0200 FS and General Electric CT/T scanners.

Humans↗

Effective atomic number and electron density as measured with a computed tomography scanner: computation and correlation with brain tumor histology.

The mathematical basis and methodology for determining the effective atomic number and electron density of a tissue are presented. Cranial computed tomography (CT) scanning is performed at two different energy levels, both with and without contrast enhancement. The histology of 15 brain tumors has been correlated with the effective atomic number and electron density of the tumor, with parameters of the linear attenuation coefficient, and with statistical values of the CT numbers. The most useful value in separating gliomas from meningiomas from metastases appears to be the percentage change of effective atomic number following contrast enhancement.

Absorptiometry, Photon↗

CT determination of parameters for inhomogeneity corrections in radiation therapy of the esophagus.

Accurate dose prediction for megavoltage photon therapy of carcinoma of the esophagus requires information on tumor depth, lung thickness, and lung density. The authors found that CT localization of internal and external contours is accurate within +/- 1 mm. Lung density can be measured with an error of less than 0.02 g/cm3 in the range 0.25-1.00 g/cm3. Variance between predicted and measured dosage was less than 3% in all patients and in most RANDO phantom measurements. Accurate radiation therapy planning is possible with CT information from a commercial scanner.

Computers↗

Patient dosage in computed tomography.

The maximum surface dosage in most clinical CT scans seems to range from 2-10 rads/study but much larger dose per study values seem possible with both rotate-translate and rotary geometry designs. The CT scanner type in itself does not significantly reduce doses. Secondary radiation dose values were measured for critical organs and indicate that dosage from secondary radiations may be reduced significantly by external shielding. Dose values in the vicinity of most CT scanners are typically 1-2 mrad/scan at 1 meter at the parameters of a typical clinical scan.

Female↗

The nonspecificity of absorption coefficients in the differentiation of solid tumors and cystic lesions.

Eleven lesions of the brain were analyzed and compared; they had absorption coefficients uniformly at the cerebrospinal fluid (CSF) level following contrast enhancement, and ranged from benign to malignant and solid to cystic. Grossly solid tumors may have absorption coefficients on the CT scan equal to CSF even after contrast enhancement. Absorption coefficients are misleading as histological indicators and in diagnosis; it is impossible to separate cystic from non-cystic, benign from malignant, and neoplastic from non-neoplastic lesions by absorption coefficients alone.

Absorption↗

Performance evaluation and quality assurance of computed tomography scanners, with illustrations from the EMI, ACTA, and Delta scanners.

Performance evaluation of equipment for computed tomography (CT) involves the integration of: (a) establishing performance criteria; (b) designing and implementing test procedures; and (c) reconciling test results in terms of desired performance. Precision (noise), contrast scale, linearity, accuracy, spatial independence, spatial resolution, artifacts, reproducible performance, and patient exposure are several parameters discussed, as are problems of measurement with regard to non-water bath scanners. Performance and quality control tests for the ACTA, Delta, and EMI scanners are outlined. Guidance for the prospective purchaser of CT equipment is presented as a summary of the ideas discussed.

Computers↗