A helium-ion beam for stereotactic radiosurgery of central nervous system disorders.

A new radiation beamline configuration for stereotactic heavy-ion Bragg peak radiosurgery of patients with intracranial deep arteriovenous malformations, including carotid-cavernous fistulas, has been developed using the 230 MeV/u helium ion beam at the 184-in. Synchrocyclotron at the University of California, Berkeley. The modified beam has five characteristics: uniform field between 10 and 40 mm in diameter; variable depth of penetration between 40 and 140 mm; stopping region for primary ions that can be broadened up to 40 mm; sharply defined lateral and distal borders; and dose rate greater than 2 Gy/min. It is adapted to the ISAH (irradiation stereotactic apparatus for humans) at the 184-in. Synchrocyclotron, with effective stereotactic localization of defined volumes within the brain, and is designed to reach all intracranial targets. It has proven suitable for all patients with intracranial vascular disorders treated with stereotactic radiosurgery at our laboratory.

Biophysical Phenomena↗

Sensitivity of helium beam-modulator design to uncertainties in biological data.

The goal in designing beam-modulating devices for heavy charged-particle therapy is to achieve uniform biological effects across the spread-peak region of the beam. To accomplish this, the linear-quadratic model for cell survival has been used to describe the biological response of the target cells to charged-particle radiation. In this paper, the sensitivity of the beam-modulator design in the high-dose region to the values of the linear-quadratic variables alpha and beta has been investigated for a 215-MeV/u helium beam, and implications for higher LET beams are discussed. The major conclusions of this work are that, for helium over the LET range of 2 to 16 keV/mu, uncertainties in measuring alpha and beta for a given cell type which are of the order of 20% or less have a negligible effect on the beam-modulator design (i.e., on the slope of the spread Bragg peak); uncertainties less than or equal to 10% in the dose-averaged LET at each depth are unimportant; and, if the linear-quadratic variables for the tumor differ from those used in the beam-modulator design by a constant factor between about 0.5 and 3, then the resultant nonuniformity in the photon-equivalent dose delivered to the tumor is within +/- 25%. It is also shown that for any ion, if the nominal values of alpha or beta used by the beam-modulator design program differ from their actual values by a constant factor, then the maximum errors possible in the beam-modulator design may be characterized by two limiting depth-dose curves such that the ratio of the dose at the proximal end of the spread Bragg curve to the dose at the distal end of the spread peak is given by alpha distal/alpha prox for the steepest curve, and square root of beta distal/beta prox for the flattest curve.

Cell Survival↗

Design of beam-modulating devices for charged-particle therapy.

The computer modeling program used to design beam-modulating devices for charged-particle therapy at Lawrence Berkeley Laboratory has been improved to allow a more realistic description of the beam. The original program used a single calculated Bragg peak to design the spread Bragg peak. The range of this curve was shifted so that Bragg curves of varying ranges could be superimposed. The new version of the program allows several measured Bragg curves with different ranges to be used as input, and interpolates between them to obtain the required data for the superposition calculation. The experimental configuration for measuring these input curves simulated therapy conditions. Seven beam-modulating propellers with spread Bragg-peak widths ranging from 2.2 to 14.4 cm were designed and constructed for a 215-MeV/u helium beam using this new design program. Depth-dose distributions produced by these new propellers were in good agreement with predicted distributions, and these propellers are currently being used clinically.

Equipment Design↗