Search PubMed⌕ Search

Biomedical subjects

J T Bryant

Publications and source records attributed to J T Bryant.

At least 37 records · Page 2Linked to original sources

Gender differences in performance of a selection test using the incremental lifting machine.

The purpose of the study was twofold: (1) to examine any gender differences in the performance of a pre-employment selection test using the incremental lifting machine (ILM); and (2) to formulate recommendations regarding analyses of selection fairness in studies of pre-employment screening tests and devices. Data were collected in a series of studies designed to permit analyses of: (1) dynamic measures derived for a 1.8 m maximum ILM strength test; (2) relationships between ILM test scores and performance of a maximal box-lifting task using three different protocols; (3) the impact of anthropom trie measures on performance of both test and task; (4) prediction of actual task performance; and (5) accuracy of the ILM screening test for three different cut-off standards. Results revealed that females differed significantly from males in their performance of a 1.8 m maximum ILM strength test in terms of timing, displacement, velocity, acceleration, force and power. Maximum ILM scores attained by females were poorly correlated with maximum box-lifting scores, but they were significantly related to body weight. Also, regression analyses based on ILM scores and associated dynamic parameters accounted for twice as much variance in box-lifting scores for males than for females. Furthermore, the use of cut-off standards of 22.7 kg and 27.3 kg produced a percentage of false negative results for females (12% and 32% respectively), but not for males. Also, for the cut-off level of 27.3 kg, female selection rates were only 56% of the selection rates for males. Issues for future investigation are recommended.

Journal Article↗

A new in vitro measurement technique for small three-dimensional joint motion and its application to the sacroiliac joint.

A new experimental technique for the measurement of three-dimensional (3-D), six degrees of freedom motion of a human joint is described. The apparatus consists of a solid cube and an orthogonal frame. Six spring-loaded linear variable differential transformers (LVDTs) are held by the frame in contact with three adjacent orthogonal surfaces of the cube. Three of the six LVDTs are positioned non-colinearly in contact with the first surface of the cube, two with the second surface, and one with the third surface. With the cube mounted on one of the moving bodies of a joint and the frame on the other one relative 3-D motion of the joint can be obtained from the six LVDT measurements based on the rigid body kinematics. An algorithm was developed to compute three Euler rotation angles and the 3-D translational components of a reference point on the body segment. The system was calibrated and applied to an in vitro study of sacroiliac joint motion. It has a rotational accuracy of 0.04 degree (with a S.D. of 0.07 degree) and a translational accuracy of 0.01 mm (with a S.D. of 0.01 mm). The possibility of adding a redundant seventh LVDT has also been explored and improvements in accuracy are reported. The main advantages of this technique are its compact size, accuracy, and low overall cost.

Biomechanical Phenomena↗

Validation of a 3D optoelectronic motion analysis system for the wrist joint.

OBJECTIVE: A study was undertaken to determine the experimental accuracy of a non-invasive optoelectonic 3-dimensional tracking system in assessing wrist joint motion. DESIGN: This was an in vivo experimental study involving volunteer subjects performing prescribed wrist motions. BACKGROUND: Current clinical practice does not include routine kinematic analysis for evaluating arthritic disease state, although motion disorders are common. METHODS: Surface markers were applied to 24 subjects assigned two hand postures in a test-retest factorial design for the expected range of motion. The marker positions were measured optoelectronically and using calibrated stereoradiography, to determine the positions of the surface markers and of key bone landmarks. Alignment and motion were compared for the three measurement techniques. Standard kinematic analyses were performed to extract Euler angles and equivalent screw displacement axes for paired postures. RESULTS: The three measurement techniques were highly correlated for wrist flexion-extension. Uncertainties were less than 6 degrees, similar to uncertainties from bone landmark identification errors when implanted markers cannot be used. Measures of motion exhibited higher correlations than those for alignment. Equivalent screw displacement axis orientations had poor intraclass correlations, reflecting sensitivity to coordinate system definitions. CONCLUSIONS: For motion analysis in the wrist in vivo, a non-invasive optoelectronic measurement system is as accurate as stereoradiographic analysis of bone segments.

Journal Article↗

A quantitative technique for reporting surface degradation patterns of UHMWPE components of retrieved total knee replacements.

A quantitative method of reporting surface degradation of the ultra-high molecular weight polyethylene (UHMWPE) tibial component from retrieved total knee replacements (TKR) was developed. Specific features include a qualitative assessment expressing the patterns in which the damage was detected as well as a quantitative summary of the observed degradation mechanisms. In addition, a method of measuring lower limb alignment changes with time is described and related to the observed damage patterns. Two case studies are presented. One case illustrated that changes in alignment resulted from factors other than wear. The damage observed on the tibial plateau appeared to occur subsequent to the changes in alignment. The second case illustrated that the wear of the UHMWPE tibial insert lead to the changes in the overall lower limb alignment. The methods described provide additional information regarding TKR failure mechanisms compared to reporting methods currently available. In particular, the collection of temporal alignment data at clinical follow-up visits enhanced the assessment of the retrieved TKR.

Biocompatible Materials↗

Compressive stress relaxation behavior of irradiated ultra-high molecular weight polyethylene at 37 degrees C.

The preconditioned stress relaxation behavior of irradiated ultra-high molecular weight polyethylene (UHMWPE), a commonly used bearing surface in total joint replacements (TJR), was modelled in uniaxial compression at 37 degrees C. Twenty cylindrical specimens (10 mm dia. x 27 mm length) were machined from a compression molded plate of medical grade UHMWPE and gamma-irradiated to a minimum dose of 2.5 Mrad. At an initial strain rate 1000%/s, five specimens were each tested at constant strains of 1, 2, 5, and 10%. The modified superposition principle provided a good agreement of the nonlinear viscoelastic (stress relaxation) behavior of UHMWPE (standard error of 0.0753 MPa).

Biocompatible Materials↗

Development of physical fitness standards for Canadian Armed Forces older personnel.

The purpose of the study was to develop a minimum physical fitness standard for Canadian Forces personnel, 35 years and older, based on common criteria for physically demanding tasks. A random sample of 100 men and 76 women performed the Exercise Prescription (EXPRES) test and five physically demanding tasks that simulate common military tasks, while restricted, for safety reasons, to 90% maximal predicted heart rate. Results indicated poor predictive power, as variances ranged from 5 to 55% between EXPRES fitness scores and task performance. With approval from an expert panel, the 75th percentile score for each task was selected as the cutting criterion. The passing-group data were converted to Z-scores in order to determine the 5th percentile from each EXPRES item: these scores became the EXPRES fitness standard. The minimum fitness standard had a greater impact on women than on men but was representative of the passing groups for both sexes.

Adult↗

Stereoradiogrammetric technique for estimating alignment of the joints in the hand and wrist.

A method and apparatus for quantitative measurement of the alignment and motion of the joints of the hand in three dimensions has been developed using stereoradiogrammetric principles. Alignment in planes of flexion-extension and radial-ulnar deviation can be determined to within 2.5 degrees; rotation about the long axis of the metacarpals or phalanges is more difficult to determine, and can be measured to within 7 degrees. Stereo views subtending angles in the range of 40 degrees were found to optimize the total system accuracy.

Calibration↗

Optimized 3D coordinate reconstruction from paired stereographs using a calibrated phantom.

A refinement to a previously described three-dimensional reconstruction algorithm based on point identification in calibrated non-orthogonal radiograms (stereo-pairs) is described. The modification involves a computation of the focal point magnitude of the point in three dimensions, analogous to focusing in two dimensions, as well as the most likely location of the target point in 3-space; the focal point magnitude may be thought of as the precision of the point identification. Multiple observer studies of the same stereopair can be used to estimate three-dimensional reconstruction accuracy by providing an average location and a mean distance from average. Both measures are useful parameters for initial selection of bone landmark references and for error propagation studies.

Algorithms↗

Precision and accuracy of bone landmarks in characterizing hand and wrist position.

Characterization of the motion of the hand and wrist requires reference to the underlying bones which, for three-dimensional analyses, are assumed to be rigid bodies. Stereoradiogrammetric techniques involving the identification of prominent bone landmarks have been used as the standard against which surface markers used for in vivo testing have been evaluated. The precision and accuracy with which the 3D positions of bone landmarks in the hand and wrist could be determined was evaluated in a small inter-observer and inter-cadaver study and compared to the precision and accuracy with which implanted lead markers could be located. A subset of landmarks suitable for evaluating wrist and metacarpal-phalangeal joint motion was identified; the mean precision for identifying these points was better than 1.1 mm in all hand positions with a mean inter-observer accuracy of 2.3 mm. These values show that the average uncertainty in locating bone landmarks is at best roughly twice that for implanted markers.

Bone and Bones↗

A kinematic technique for describing wrist joint motion: analysis of configuration space plots.

This paper describes an experimental method for determining the minimum number of degrees of freedom of a human joint. Application of this technique to the wrist suggests that the normal, intact wrist joint uses only two degrees of freedom to move in a plane that is not aligned with the anatomic planes. The technique may be useful in identifying emerging joint pathologies and in simplifying kinematic models of joint function.

Biomechanical Phenomena↗

Rationalization of kinematic descriptors for three-dimensional hand and finger motion.

Modelling joint motion in three dimensions is often based on techniques taken from classical dynamics, each analysis resulting in a set of six parameters describing the relative motion between two body segments. The literature on joint kinematics has been difficult to compare due to use of different anatomical landmarks, axis nomenclature, and analytical methods. It is here shown that with care in sequence definition, the three alignment-based systems (Euler, Cardan, floating axis) give identical results for angular parameters. While the equivalent screw displacement axis system can be related simply to the other methods only if the functional axis of motion is aligned with a coordinate axis, the basic matrix for relating rigid body positions before and after a motion can always be reconstructed. Therefore the changes in alignment angles may be obtained from screw displacement parameters, permitting the results of different analyses to be compared. Translation parameters are most difficult to interpret in any system. Examples of the way in which simple planar motions are characterized by the various analytical methods are given.

Biomechanical Phenomena↗

Development of physical fitness standards for Canadian Armed Forces younger personnel.

The purpose of this study was to develop minimum physical fitness standards based on common task criteria for personnel younger than 35 years of age in the Canadian Armed Forces. A random sample of 66 men and 144 women performed the Exercise Prescription (EXPRES) test and five physically demanding tasks that simulated common military tasks. Common cutting scores were selected as the point at which 75% of the total weighted sample passed each task. Since there were significant differences between the sexes in task performance and technique execution, the groups were analyzed separately. Results indicated a range in variance of 14 to 48% between military task performance and physical fitness test score, thus suggesting that fitness measures are a poor predictor of task performance. Because of the low variance observed the passing group of each task was treated as a representative sample of subjects whose fitness profiles were indicative of those able to meet task criteria. The 5th percentile fitness scores of the passing group were proposed as the minimum fitness standard. These conditions resulted in fitness standards that were physically more demanding for women than for men.

Adult↗

Generalized oddity performance in preschool children: a bimodal training procedure.

Oddity performance requires relational discriminative responding, which typically is difficult to establish in children with MAs below five. In Experiment 1, a combination intrasubject reversal and multiple baseline across subjects design was used to establish the internal validity of a bimodal intervention in establishing generalized oddity performance. Six of seven children demonstrated oddity responding when presented with stimuli that instantiated the oddity relation in the visual and auditory modalities simultaneously. Oddity performance was evaluated with both reversal assessments and assessments with new sets of stimuli. The newly acquired oddity performance was durable; the six children continued to respond discriminatively when returned to a visual-only task on which they previously had been unsuccessful. Utilizing a reversal assessment more stringent than that of Experiment 1, Experiment 2 replicated this effect. The present studies are the first to demonstrate the utility of bimodal training in establishing oddity performance. The bimodal procedure is discussed with respect to the theoretical positions of Gibson, Dinsmoor, and Dixon.

Attention↗

A quantitative approach to radiography of the lower limb. Principles and applications.

A method is described which provides standardised reproducible radiographic images of the lower limb. Anteroposterior and lateral radiographs are digitised and processed by computer to provide graphic/numeric displays of angles and linear measurements, relating the centre points of the hip, knee, and ankle. Two cases illustrate how surgical planning is facilitated when standardised data are available. These data confirm the close relationship between postoperative limb alignment and positioning of prosthetic elements.

Aged↗

Single camera photogrammetric technique for restricted 3D motion analysis.

The purpose of this study was to use a single camera to determine the true elbow flexion angle with the arm plane oriented arbitrarily with respect to the camera. A mathematical theory was developed and a mechanical arm model was constructed to validate the theory. A static weightlifting skill was analysed to investigate the viability of the technique on the human subject. The validation of the theory showed the error associated with the elbow flexion angle was reduced from as high as 108 degrees when uncorrected to within 3 degrees when corrected by the technique. The elbow flexion angle of the human arm can be calculated to within 6 degrees of error for static weightlifting skill analysis.

Algorithms↗

Effects of grid dimensions on finite element models of an articular surface.

Recent activity in finite element analysis of articular joints has emphasized refinements in geometry and material properties. In the implementation of such models, it is necessary to ensure that grid dimensions are optimal for suitable solutions of displacements, strains and stresses. A method of grid optimization was developed to ensure that for typical material properties, finite element models of an articular surface agree with known analytical solutions. The layered axisymmetric model presented by Askew and Mow (J. biomech. Engng 100, 105-115, 1978) was used as a reference. From this reference, an STZ of 0.2 mm, middle and deep zones of 0.8 mm and tidemark region of 0.2 mm were chosen. Cancellous bone was an infinite elastic half space under these layers. Loading was a parabolic distribution over a 10 mm radius having a peak of 1 MPa. Agreement was obtained between analytical solutions and finite element solutions when the finite element model had a radial boundary of 30 mm radius and a bone depth of 32 mm. These results suggested that in models of real joints, care must be taken to ensure the boundaries are reasonably represented and that sufficient bone is modelled for adequate solutions.

Biomechanical Phenomena↗