Search PubMed⌕ Search

Biomedical subjects

J T Barr

Publications and source records attributed to J T Barr.

At least 19 recordsLinked to original sources

American translation, modification, and validation of the St. George's Respiratory Questionnaire.

BACKGROUND: The St. George's Respiratory Questionnaire (SGRQ) is a 50-item health status survey specific for chronic obstructive pulmonary disease (COPD) and other respiratory diseases that is available in British English but not American English. The SGRQ's symptom-reporting component requires a 1-year reporting period, which may be too long for reliable and accurate patient recall. OBJECTIVES: The objectives of the present study were to translate the SGRQ from British to American English, modify the reporting period of the symptom-reporting component from 1 year to 1 month, and assess the reliability, validity, and sensitivity to change of this translated modified version in a sample of patients with COPD. METHODS: Based on input from American patients with COPD and health professionals, the SGRQ was translated into American English (SGRQ-A) and then translated back to British English. For SGRQ-A reliability and validity studies, patients were asked to report symptoms experienced over 1 year (reporting period in the original SGRQ) and 1 month (modification made to SGRQ-A). We evaluated 102 patients with COPD (50% female; mean age, 68 years; mean forced expiratory volume in 1 second [FEV1], 1.01 L) at an administrative session before and after completion of a pulmonary rehabilitation program. The SGRQ-A, Chronic Respiratory Disease Questionnaire (CRQ), 36-Item Short Form Health Survey (SF-36), 6-minute walk (6MW), Medical Research Council (MRC) Dyspnea scale, and pulmonary function tests (FEV1 and % predicted FEV1) were used in the assessment battery. RESULTS: The SGRQ-A showed good agreement with the original SGRQ when translated back to British English. Internal reliability (Cronbach alpha) was > 0.70 for all SGRQ-A components except the 1-year symptom-reporting component. Test-retest intraclass correlations were 0.795 to 0.900. Construct validity was strengthened when all SGRQ-A components (except 1-year symptoms and most 1-month symptoms) correlated (P < or = 0.01) with the MRC Dyspnea scale, 6MW, all SF-36 concept scores, and 80% of CRQ domains (r = 0.30-0.72). Discriminate validity was demonstrated when all components of the SGRQ-A with the modified 1-month symptom-reporting period were shown to discriminate better between disease-severity groups (based on patient self-reports of disease severity) than did pulmonary function tests and the 6MW. Responsiveness of the SGRQ-A to change in health status was demonstrated when scores on the Symptoms-1 month and Total-1 month components detected significant improvements in patients' health status (P = 0.02 and P = 0.04, respectively). CONCLUSION: The SGRQ-A with a modified 1-month symptom-reporting period demonstrated reliability and validity in this sample of patients with COPD. Key words: chronic obstructive pulmonary disease, St. George's Respiratory Questionnaire, American translation, reliability, validity, symptom recall.

Adult↗

Factors associated with corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study.

PURPOSE: The multicenter Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a prospective, observational study of 1,209 keratoconus patients. We report on the factors associated with corneal scarring at baseline. METHODS: We defined corneal scarring as scars that had been detected both by the clinician examining the patient with the slit-lamp biomicroscope and by masked readers of corneal photographs at the CLEK Photography Reading Center. We investigated associations between corneal scarring and patient variables including gender, ethnicity, a family history of keratoconus, a history of ocular trauma, eye rubbing, contact lens wear, rigid contact lens fitting relationships, and corneal findings (such as curvature, Vogt's striae, Fleischer's ring, and central/apical staining). Multiple logistic regression analysis using generalized estimating equations to adjust for the correlation between eyes was used for analysis. RESULTS: The following factors were found to increase the odds of corneal scarring at baseline in the CLEK Study: corneal staining (odds ratios (OR) = 3.40, 95% confidence interval 2.53-4.59), contact lens wear (OR = 3.51, 95% confidence interval 2.27-5.45), Fleischer's ring (OR = 1.63, 95% confidence interval 1.11-2.40), steeper first definite apical clearance lens base curve radius (per diopter, OR = 1.29, 95% confidence interval 1.25-1.33), and age (per decade, OR = 1.54, 95% confidence interval 1.35-1.75). CONCLUSIONS: These baseline data suggest that corneal scarring in keratoconus is associated with corneal staining, contact lens wear, Fleischer's ring, a steeper cornea, and increasing age. The factors that imply added risk for corneal scarring that may be affected by practitioner intervention are staining of the cornea, contact lens wear, and the contact lens fitting relationship.

Adult↗

Corneal scarring and vision in keratoconus: a baseline report from the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study.

PURPOSE: The multicenter Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a prospective, observational study of 1,209 keratoconus patients. We report on the correlation of corneal scarring with clinical and patient-reported variables at the baseline visit. METHODS: Patients completed a questionnaire on their vision, effect of glare, contact lens wear, and work-related issues. Clinical examination included high- and low-contrast visual acuity, refraction, assessment of corneal scarring by the clinician and by photography, and measurement of corneal curvature. The correlation of central corneal scarring with visual acuity and patient-reported variables was analyzed using multiple regression analysis and generalized estimating equations. RESULTS: High- and low-contrast visual acuity with habitual and optimal correction is reduced in scarred eyes. Multiple regression analyses controlling for age, contact lens wear, and disease severity show that central scarring is associated with poorer visual acuity and increased patient-reported symptoms of glare. Restrictions on day-to-day activities do not appear to be associated with corneal scarring above and beyond the effects of keratoconus alone. CONCLUSIONS: Corneal scarring in keratoconus is significantly associated with decreased high- and low-contrast visual acuity.

Cicatrix↗

Overnight orthokeratology.

PURPOSE: Orthokeratology is defined as the temporary reduction in myopia by the programmed application of rigid gas-permeable contact lenses. New reverse geometry contact lens designs and materials have led to a renewed interest in this field. The purpose of this study is to assess visual, refractive, topographic, and corneal thickness changes in subjects undergoing overnight orthokeratology. METHODS: Ten myopic subjects (mean age, 25.9+/-3.9 years) were recruited for a 60-day trial of overnight orthokeratology using reverse geometry rigid contact lenses. After commencing lens wear, subjects were examined on days 1, 7, 14, 30, and 60 at several times throughout the day. High- and low-contrast logarithm of the minimum angle of resolution (logMAR) visual acuity, monocular subjective refraction, autorefraction, autokeratometry, corneal topography, corneal thickness, and slit lamp examinations were performed at each session. RESULTS: Eight subjects completed the study. Both high- and low-contrast uncorrected visual acuity improved significantly by day 7. The mean change in uncorrected high contrast visual acuity at day 60 was -0.55+/-0.20 logMAR (mean at day 60, -0.03+/-0.16; Snellen equivalent, 20/19). The mean change in uncorrected low-contrast visual acuity at day 60 was -0.48+/-0.26 logMAR (mean at day 60, +0.22+/-0.23; Snellen equivalent, 20/33). The mean subjective refraction and autorefraction were significantly reduced from baseline at day 60 (mean change in subjective refraction, +1.83+/-1.23 D; mean change in autorefraction, +0.64+/-0.52 D). Corneal topography showed significant central flattening (mean change in apical radius, +0.20+/-0.9 mm; mean change in shape factor, -0.11+/-0.18 at day 60). The central cornea also showed significant thinning (mean change, -12+/-11 microm at day 60). All visual, refractive, and topographic outcomes were sustained over the course of an 8-h day. CONCLUSIONS: Overnight orthokeratology is an effective means of temporarily reducing myopia. The possible mechanism of corneal remodeling through central corneal thinning is discussed.

Adult↗

Rigid contact lens fitting relationships in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group.

PURPOSE: Although the influence of flat-fitting contact lenses on corneal scarring in keratoconus is frequently debated, the current standard of care with regard to the apical fitting relationship in keratoconus remains undocumented. METHODS: Patients were examined at baseline in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study (N = 1209). Patients wearing a rigid contact lens in one or both eyes (N = 808) had their habitual rigid contact lenses analyzed, and the fluorescein patterns and base curves were compared to the first definite apical clearance lens (FDACL). The FDACL is the flattest lens in the CLEK Study trial lens set that exhibits an apical clearance fluorescein pattern. For patients wearing a rigid contact lens in both eyes, one eye was selected randomly for analysis. RESULTS: Twelve percent of the rigid contact lens-wearing eyes were wearing lenses fitted with apical clearance based upon the clinician's fluorescein pattern interpretation. The remainder (88%) was wearing lenses fitted with apical touch. For mild (steep keratometric reading <45 D) keratoconus corneas, the mean estimate of the base curve to cornea-fitting relationship was 1.18 D flat (SD +/- 1.84 D); moderate (steep keratometric reading: 45 to 52 D) corneas were fitted on average 2.38 D flat (SD +/- 2.56 D); and severe (steep keratometric reading > 52 D) corneas were fitted an average of 4.01 D flat (SD +/- 4.11 D). CONCLUSIONS: Despite the potential risk for corneal scarring imposed by flat-fitting rigid contact lenses, most CLEK Study patients wear flat-fitting lenses. Overall, rigid lenses were fitted an average of 2.86 D (SD +/- 3.31 D) flatter than the FDACL.

Contact Lenses↗

Corneal scarring in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study: baseline prevalence and repeatability of detection.

PURPOSE: The multicenter Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is a prospective, observational study of 1,209 keratoconus patients. We report on the prevalence of corneal scarring in these patients. We also report on the test-retest repeatability of corneal scar documentation at the slit-lamp biomicroscope by trained clinicians and by masked photograph readers and on the scarring-status agreement at baseline between clinicians and photograph readers. METHODS: Clinicians and masked photograph readers graded each cornea as to scarring status. Patients were examined by clinicians, and their corneas were photographed at baseline (2,297 nongrafted eyes of 1,209 patients) and at a repeated visit (258 nongrafted eyes of 138 patients). These photographs were evaluated by the masked readers at the CLEK Photography Reading Center (CPRC). Clinicians reported corneal scars in right eyes at baseline as "definitely not present" in 53.9%, "probably not present" in 8.4%, "probably present" in 8.2%, and "definitely present" in 29.4% of patients. A weighted kappa statistic of 0.83 (95% confidence interval from 0.78 to 0.88) indicates that agreement is excellent between baseline and repeated assessments for the presence of a corneal scar by clinicians. RESULTS: Agreement is very good between baseline and repeated photograph-reader assessments for the presence of a scar, with a weighted kappa of 0.77 (95% confidence interval, 0.72-0.82). The kappa statistic comparing photograph-reader scarring assessments with clinician results was 0.69 (95% confidence interval, 0.66-0.71). CONCLUSION: The data also suggest better agreement between clinicians and readers when Vogt's striae and corneal nerves were observed. The data also suggest better agreement when corneal staining was not observed by the photograph readers. The CLEK Study protocol for determining the presence of scars is highly repeatable.

Cicatrix↗

Is O-K okay?

Explore the source record for details and available documents.

Contact Lenses↗

Effect of topical anesthetic use on initial patient satisfaction and overall success with rigid gas permeable contact lenses.

BACKGROUND: Rigid gas permeable (RGP) contact lenses have numerous benefits; however, RGP lens use is not increasing in the United States. An important factor for this trend has been initial comfort. Studies have demonstrated that how RGPs are presented to patients, in addition to lens design, can play an important role in the initial comfort process. Another important factor could be the use of a topical anesthetic during the fitting and dispensing visits. The purpose of this study was to use a multicenter format to determine if topical anesthetic use increased the likelihood of patient satisfaction and success. METHODS: A total of 80 subjects, with no previous rigid lens wear experience, was entered into this 1-month study, including 20 subjects from each of 4 institutions. Subjects were randomly divided into the following two groups: (A) anesthetic or (B) placebo, with the former group receiving one drop of a topical anesthetic before lens insertion at both the diagnostic fitting and dispensing visits, whereas the latter group received a placebo. Subjects completed a questionnaire on their perception of rigid lens wear both immediately before fitting and at the 1-month visit. After diagnostic fitting with rigid lenses, subjects completed an adaptation questionnaire after 15 min, 1 week, 2 weeks, and 1 month of lens wear. RESULTS: Seventy of the 80 subjects completed the study and, of the 10 subjects who discontinued, 8 were in the placebo group. In all categories evaluated, the anesthetic group experienced a more optimum adaptation experience at each visit vs. the placebo group. Specifically, overall comfort was rated significantly higher at both dispensing and 2 weeks. In addition, the anesthetic group exhibited significantly greater overall satisfaction with rigid lens wear at 2 and 4 weeks. Also, the anesthetic group perceived their adaptation, sensitivity, and adaptation time to be significantly better at the 1-month visit. There was no significant difference in corneal staining between these two groups at each visit, with the exception of a greater amount of staining in the central quadrant for the placebo group at the 1-month visit. CONCLUSIONS: The use of a topical anesthetic at the fitting and dispensing visits for first-time wearers of RGP lenses resulted in significantly fewer dropouts, improved initial comfort, an enhanced perception of the adaptation process, and greater overall satisfaction after 1 month of lens wear as compared to the use of a nonanesthetizing placebo at those visits. This result, in combination with both presenting RGP lenses in a nonthreatening manner and optimizing the lens design and fitting relationship, should result in a positive adaptation process and successful wear of RGP contact lenses.

Adaptation, Physiological↗

Economic and outcome issues for therapeutic drug monitoring in medicine.

Outcome and economic studies pertaining to the use of therapeutic drug monitoring (TDM) are summarized. The studies were classified by a 2 x 2 matrix comprised of process, outcome, system-related variables, and patient-centered variables. Two hundred forty-seven studies conducted from 1974 to 1994, culled from eight summary sources, were reviewed. Almost 75% of the studies reported system-related, not patient-centered, measures for assessing the value of TDM; nearly the same percentage evaluated processes as opposed to outcome measures. Studies comparing TDM to non-TDM populations generally showed that TDM as an intervention reduced the rate of undesirable system-related variables by 50% and increased the rate of desirable system-related variables by 100%. For patient-centered variables, TDM was less dramatic, decreasing the rate of undesirable variables by 15% to 50%. Only 8% of the studies examined economic variables. TDM-influenced changes in process variables resulted in a projected mean annual savings of $37,000. The few studies available of cost-benefit analysis focused on aminoglycosides and showed that TDM yielded a range from 4:1 to 52:1 in benefit-to-cost ratio. Most studies have limitations that include small sample size, short study periods to predict long-term outcomes, no long-term follow-up, and designs for noncontrolled study.

Drug Monitoring↗

Total testing process applied to therapeutic drug monitoring: impact on patients' outcomes and economics.

The Total Testing Process (TTP) refers to the sequence of 11 steps of laboratory testing, beginning with a clinical question prompted by the patient-clinician encounter and concluding with the impact of the test result on patient care. TTP when applied to therapeutic drug monitoring (TDM) emphasizes that TDM must be considered a process involving a series of steps and interrelated activities and not viewed simply as a numerical value for a serum drug concentration. TTP is also an ideal format for organizing and identifying the system-related and patient-centered variables used in outcomes assessment of TDM, as well as providing a template for collecting the cost data needed for economic analyses. Examples are provided for improving application of TDM by practitioners, clinical laboratories, and educators.

Blood Chemical Analysis↗

Repeatability and agreement of two corneal-curvature assessments in keratoconus: keratometry and the first definite apical clearance lens (FDACL). CLEK Study Group. Collaborative Longitudinal Evaluation of Keratoconus.

PURPOSE: This study was conducted to determine the agreement and test-retest repeatability of two methods for measuring corneal curvature in keratoconus: keratometry and the First Definite Apical Clearance Lens (FDACL). Our interest in the FDACL procedure stems from the important contact lens-fitting information and documentation of disease progression provided by the FDACL trial lenses and observation of fluorescein patterns. METHODS: The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study is an observational study that has enrolled 1,209 keratoconus patients to characterize the progression of keratoconus, to determine factors associated with its progression, and to assess its impact on quality of life. Ten percent of the patients were randomly selected at baseline for a retest examination. The baseline examination, which included keratometry and FDACL, was repeated in this sample. The FDACL is the flattest lens in the standardized CLEK trial lens set that vaults the apex of the cone. FDACL provides an estimate of the sagittal height of the cone. RESULTS: The correlation of FDACL with the steep keratometric reading (r = 0.89; p = 0.0001) and the flat keratometric reading (r = 0.83; p = 0.0001) were high. Test-retest repeatability as measured by the intraclass correlation coefficient (ICC) was high: FDACL ICC, 0.97; steep keratometric reading ICC, 0.96; and flat keratometric reading ICC, 0.95. Test-retest repeatability of FDACL remained high in advanced disease. CONCLUSION: FDACL provides a repeatable new procedure for determining disease severity in keratoconus.

Adult↗

Baseline findings in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study.

PURPOSE: To describe the baseline findings in patients enrolled in the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study. METHODS: This is a longitudinal observational study of 1209 patients with keratoconus enrolled at 16 clinical centers. Its main outcome measures are corneal scarring, visual acuity, keratometry, and quality of life. RESULTS: The CLEK Study patients had a mean age of 39.29+/-10.90 years with moderate to severe disease, assessed by a keratometric-based criterion (95.4% of patients had steep keratometric readings of at least 45 D) and relatively good visual acuity (77.9% had best corrected visual acuity of at least 20/40 in both eyes). Sixty-five percent of the patients wore rigid gas-permeable contact lens, and most of those (73%) reported that their lenses were comfortable. Only 13.5% of patients reported a family history of keratoconus. None reported serious systemic diseases that had been previously reported to be associated with keratoconus. Many (53%) reported a history of atopy. Fifty-three percent had corneal scarring in one or both eyes. CONCLUSIONS: Baseline findings suggest that keratoconus is not associated with increased risk of connective tissue disease and that most patients in the CLEK Study sample represent mild to moderate keratoconus. Additional follow-up of at least 3 years will provide new information about the progression of keratoconus, identify factors associated with progression, and assess its impact on quality of life.

Adult↗

Rigid gas-permeable contact lenses in high and low humidity.

BACKGROUND: Contact lenses may alter tear film evaporation. Evaporation varies with respect to air temperature and relative humidity. Hence, tear evaporation may be a significant factor for many occupations, such as military pilots, in the arid environments in which they operate. METHODS: The study tested rigid gas-permeable (RGP) contact lens wearer comfort and corneal staining in lower and higher relative humidity environments. RESULTS: A trend was found that in a lower humidity environment, RGP contact lens comfort may decrease for some subjects. Corneal surface integrity was not compromised by the variation in relative humidity level, as determined by fluorescein dye analysis. CONCLUSION: Within the range of humidity tested, for normal successful RGP patients, drier environments do not substantially reduce lens comfort.

Adult↗

Biomicroscopic signs and disease severity in keratoconus. Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Study Group.

The Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Survey represents the largest sample of clinic-based keratoconus patients to date. Data were collected at 38 clinical centers on 1,579 keratoconus patients. This article reports demographic variable, ages, self-reported ages at diagnosis, keratometry, slit-lamp findings, systemic disease, family history of keratoconus, and best spectacle-corrected and contact lens-corrected visual acuity of this sample group. The average age of this clinic-based sample group was 37 years (range 10-89 years), with 84% between 20 and 49 years old. Thirteen percent of patients had unilateral keratoconus, defined as unilateral corneal irregularity. More advanced disease (steeper average keratometric reading) was associated with a greater likelihood of Vogt's striae, Fleischer's ring, and/or corneal scarring. Fifty-eight percent of the eyes in this group of patients had > or = 20/40 visual acuity with manifest refraction. Penetrating keratoplasty was reported in 12.3% of eyes. This prospective survey identifies the associates between the presence of Vogt's striae, Fleischer's ring, and/or corneal scarring and increasing steepness, as measured by keratometry.

Adolescent↗

Characteristics of corneal staining in hydrogel contact lens wearers.

Corneal fluorescein staining is widely used in clinical practice and research, but little information exists on the distribution of staining in a large group of asymptomatic contact lens wearers. This cross-sectional study took place at 3 centers, and investigated the pattern of corneal fluorescein staining in both eyes of 98 hydrogel contact lens wearers. We also investigated the strategies used by three experienced clinicians to grade corneal staining. Overall corneal staining was graded using a scale from 0 to 4 in one-half steps, and five corneal zones, superior, inferior, nasal, temporal, and central, were also graded. The average overall staining grade for both eyes of our subjects was 0.50, with an average of 0.57 for the right eye and 0.44 for the left. This difference between the eyes was statistically significant (p = 0.011). In addition, a comparison of the zones within each eye showed a significant difference (p = 0.0001) among the zones. Corneal staining between the two eyes was also positively and significantly correlated (r = 0.58; p = 0.0001). Grading strategies among clinical investigators were significantly different (p = 0.0001), indicating a potential source of bias in multi-centered studies. The difference in corneal staining between the eyes may represent a source of systematic bias, and could be due to grading the right eye before the left. The correlation in corneal staining between the eyes indicates that the two eyes of a subject cannot serve as independent data points. One-third of the subjects who participated in this study had notable corneal staining. This finding underlines the importance of regularly checking corneal staining in clinical practice.

Contact Lenses↗

Standardized rigid contact lens fitting protocol for keratoconus.

Keratoconus is typically managed by a variety of rigid contact lens fitting techniques and lens designs. The two most fundamental fitting techniques are apical corneal touch (including divided or three-point touch) and apical clearance. In the course of designing a multi-center study of keratoconus patients, a standardized keratoconus fitting protocol was developed. All contact lens parameter options are uniform except for base curve and secondary curve radii, which are determined by interpretation of fluorescein patterns using the CLEK Study trial lens set and protocol. The initial trial lens's base curve is the average keratometric reading; sequentially steeper lenses are applied until definite apical clearance is observed. We have evaluated the feasibility of this standardized fitting protocol on 30 keratoconus patients. Our results suggest that we have developed a standardized contact lens fitting set and fitting protocol to simplify contact lens management in patients with mild to moderate keratoconus.

Contact Lenses↗

Feasibility of fitting contact lenses with apical clearance in keratoconus.

Despite the wide variety of rigid contact lens fitting philosophies for the visual correction of keratoconus, questions remain, including which approach-flat, divided support, or steep-contributes the most toward the preservation of a clear cornea. One goal of the Collaborative Longitudinal Evaluation of Keratoconus (CLEK) Pilot Study was to determine the feasibility of managing early keratoconus patients with apical clearance rigid contact lenses. Of 30 keratoconus patients identified with at least 1 nonscarred cornea, 17 patients (30 eyes) were randomly assigned to a steep lens fitting protocol. After trial fitting with a standardized lens design demonstrating minimum apical clearance, lenses were dispensed whose base curve was 0.2 mm steeper than the minimum apical clearance lens. Patients were re-evaluated on a quarterly schedule concluding at 12 months. Changes in keratometry between baseline and 12 months identified unequal steepening of the flat and steep corneal curvatures, suggestive of corneal molding. Best corrected rigid lens visual acuity measures illustrated no significant changes over the course of the study. Clinically significant corneal compromise was transiently observed in some patients. Only 1 of 22 eyes completing the pilot study and fitted with apical clearance developed mild corneal scarring.

Adolescent↗