Search PubMed⌕ Search

Biomedical subjects

J Sundell

Publications and source records attributed to J Sundell.

At least 37 records · Page 2Linked to original sources

'EUROPART'. Airborne particles in the indoor environment. A European interdisciplinary review of scientific evidence on associations between exposure to particles in buildings and health effects.

The relevance of particle mass, surface area or number concentration as risk indicators for health effects in non-industrial buildings has been assessed by a European interdisciplinary group of researchers (called EUROPART) by reviewing papers identified in Medline, Toxline, and OSH. Studies dealing with dermal effects or cancer or specifically addressing environmental tobacco smoke, house dust-mite, cockroach or animal allergens, microorganisms and pesticides were excluded. A total of 70 papers were reviewed, and eight were identified for the final review: Five experimental studies involving mainly healthy subjects, two cross-sectional office studies and one longitudinal study among elderly on cardiovascular effects. From most studies, no definite conclusions could be drawn. Overall, the group concluded that there is inadequate scientific evidence that airborne, indoor particulate mass or number concentrations can be used as generally applicable risk indicators of health effects in non-industrial buildings and consequently that there is inadequate scientific evidence for establishing limit values or guidelines for particulate mass or number concentrations.

Air Pollution, Indoor↗

The effects of insulin and short-term hyperglycaemia on myocardial blood flow in young men with uncomplicated Type I diabetes.

AIMS/HYPOTHESIS: Insulin enhances coronary vasodilation in healthy subjects. We tested whether insulin is able to induce coronary vasodilation in Type I (insulin-dependent) diabetic mellitus patients. Additionally, the effect of short-term hyperglycaemia on myocardial perfusion was studied. METHODS: Myocardial blood flow was quantitated basally and during adenosine infusion (140 microg/kg per min i.v.) with or without simultaneous insulin infusion (1 mU/kg per min for 60 min) in nine non-smoking Type I diabetic males (HbA(1c) 7.4+/-1.0%) without diabetic complications and 10 healthy non-diabetic otherwise matched males using positron emission tomography and (15)O-water. Diabetic patients were studied on two occasions, once during normoglycaemia (plasma glucose ~6 mmol/l) and once during hyperglycaemia (approximately 10 mmol/l) induced by reducing the dose of insulin for two days. RESULTS: Resting myocardial blood flow was similar in the studied groups (NS). Hyperaemic adenosine stimulated flow was 23% lower in diabetic than in non-diabetic subjects (3.09+/-0.72 vs 4.0+/-1.13 ml x g(-1) x min(-1), p<0.05). Insulin increased significantly adenosine stimulated flow by 23% in diabetic and 17% in non-diabetic subjects (NS between the groups). Hyperglycaemia for two days had no effect on flow values when compared to the values during normoglycaemia (NS). CONCLUSION/INTERPRETATION: Insulin has similar vasodilative effects on coronary arteries in diabetic and non-diabetic subjects. Short-term hyperglycaemia does not alter myocardial blood flow or abolish insulin induced vasodilation in these patients. Insulin induced coronary vasodilation might contribute to the known beneficial effect of intensive insulin therapy on myocardial ischaemia in diabetic patients.

Adenosine↗

Subjective perceptions, symptom intensity and performance: a comparison of two independent studies, both changing similarly the pollution load in an office.

The present paper shows that introducing or removing the same pollution source in an office in two independent investigations, one in Denmark and one in Sweden, using similar experimental methodology, resulted in similar and repeatable effects on subjective assessments of perceived air quality, intensity of sick building syndrome symptoms and performance of office work. Removing the pollution source improved the perceived air quality, decreased the perceived dryness of air and the severity of headaches, and increased typing performance. These effects were observed separately in each experiment and were all significant (P < or = 0.05) after combining the data from both studies, indicating the advantages of pollution source strength control for health, comfort, and productivity.

Adult↗

Ventilation and health in non-industrial indoor environments: report from a European multidisciplinary scientific consensus meeting (EUROVEN).

Scientific literature on the effects of ventilation on health, comfort, and productivity in non-industrial indoor environments (offices, schools, homes, etc.) has been reviewed by a multidisciplinary group of European scientists, called EUROVEN, with expertise in medicine, epidemiology, toxicology, and engineering. The group reviewed 105 papers published in peer-reviewed scientific journals and judged 30 as conclusive, providing sufficient information on ventilation, health effects, data processing, and reporting, 14 as providing relevant background information on the issue, 43 as relevant but non-informative or inconclusive, and 18 as irrelevant for the issue discussed. Based on the data in papers judged conclusive, the group agreed that ventilation is strongly associated with comfort (perceived air quality) and health [Sick Building Syndrome (SBS) symptoms, inflammation, infections, asthma, allergy, short-term sick leave], and that an association between ventilation and productivity (performance of office work) is indicated. The group also concluded that increasing outdoor air supply rates in non-industrial environments improves perceived air quality; that outdoor air supply rates below 25 l/s per person increase the risk of SBS symptoms, increase short-term sick leave, and decrease productivity among occupants of office buildings; and that ventilation rates above 0.5 air changes per hour (h-1) in homes reduce infestation of house dust mites in Nordic countries. The group concluded additionally that the literature indicates that in buildings with air-conditioning systems there may be an increased risk of SBS symptoms compared with naturally or mechanically ventilated buildings, and that improper maintenance, design, and functioning of air-conditioning systems contributes to increased prevalence of SBS symptoms.

Air Pollution, Indoor↗

Dampness in buildings and health. Nordic interdisciplinary review of the scientific evidence on associations between exposure to "dampness" in buildings and health effects (NORDDAMP).

Several epidemiological investigations concerning indoor environments have indicated that "dampness" in buildings is associated to health effects such as respiratory symptoms, asthma and allergy. The aim of the present interdisciplinary review is to evaluate this association as shown in the epidemiological literature. A literature search identified 590 peer-reviewed articles of which 61 have been the foundation for this review. The review shows that "dampness" in buildings appears to increase the risk for health effects in the airways, such as cough, wheeze and asthma. Relative risks are in the range of OR 1.4-2.2. There also seems to be an association between "dampness" and other symptoms such as tiredness, headache and airways infections. It is concluded that the evidence for a causal association between "dampness" and health effects is strong. However, the mechanisms are unknown. Several definitions of dampness have been used in the studies, but all seems to be associated with health problems. Sensitisation to mites may be one but obviously not the only mechanism. Even if the mechanisms are unknown, there is sufficient evidence to take preventive measures against dampness in buildings.

Air Pollution, Indoor↗

The effects of outdoor air supply rate in an office on perceived air quality, sick building syndrome (SBS) symptoms and productivity.

Perceived air quality, Sick Building Syndrome (SBS) symptoms and productivity were studied in a normally furnished office space (108 m3) ventilated with an outdoor airflow of 3, 10 or 30 L/s per person, corresponding to an air change rate of 0.6, 2 or 6 h-1. The temperature of 22 degrees C, the relative humidity of 40% and all other environmental parameters remained unchanged. Five groups of six female subjects were each exposed to the three ventilation rates, one group and one ventilation rate at a time. Each exposure lasted 4.6 h and took place in the afternoon. Subjects were unaware of the intervention and remained thermally neutral by adjusting their clothing. They assessed perceived air quality and SBS symptoms at intervals, and performed simulated normal office work. Increasing ventilation decreased the percentage of subjects dissatisfied with the air quality (P < 0.002) and the intensity of odour (P < 0.02), and increased the perceived freshness of air (P < 0.05). It also decreased the sensation of dryness of mouth and throat (P < 0.0006), eased difficulty in thinking clearly (P < 0.001) and made subjects feel generally better (P < 0.0001). The performance of four simulated office tasks improved monotonically with increasing ventilation rates, and the effect reached formal significance in the case of text-typing (P < 0.03). For each two-fold increase in ventilation rate, performance improved on average by 1.7%. This study shows the benefits for health, comfort and productivity of ventilation at rates well above the minimum levels prescribed in existing standards and guidelines. It confirms the results of a previous study in the same office when the indoor air quality was improved by decreasing the pollution load while the ventilation remained unchanged.

Adolescent↗

Cumulative UV radiation dose and outcome in clinical practice: effectiveness of trioxsalen bath PUVA with minimal UVA exposure.

BACKGROUND: The cumulative artificial ultraviolet (UV) exposure dose of dermatological patients was prospectively monitored in clinical conditions for a total of 2 years (August 1997 - July 1999). We focused on whole body UV treatments, i.e. the trioxsalen (TMP) bath PUVA, the broad-band UVB, and the UVA plus UVB phototherapy. METHODS: Irradiance of the UV devices was calibrated with a spectroradiometer. The cumulative UV doses received by the patients were recorded. A visual analog scale scoring system (VAS) was employed to assess the improvement of various skin conditions at the end of the treatment course. RESULTS: The analysis included 265 patients (141 females and 124 males) and a total of 311 UV treatment courses. Treatments consisted of 86 courses of TMP bath PUVA for psoriasis with a mean cumulative UVA dose of 3.54 J/cm2 and an improvement rate of 89%. For other conditions, 30 courses were needed, with a cumulative UVA dose of 1.47 J/cm2 and an improvement rate of 76%. Altogether, 47 UVB courses were undertaken for psoriasis, and the mean cumulative unweighted UV dose was 2.20 J/cm2, equivalent to 85 standard erythema doses (SED), and an improvement rate of 85%. A total of 25 UVB courses was used for other skin conditions with a mean UV dose of 1.05 J/ cm2, equivalent to 40 SED, and an improvement rate of 71%. A total of 123 courses of UVA plus UVB phototherapy were completed, resulting in a mean cumulative dose of 73.01 J/cm2 for UVA and 0.75 J/cm2 for the unweighted UVB, equivalent to 29 SED. The VAS improvement rate was 85%. CONCLUSION: The exceptionally low mean cumulative UVA dose in the TMP bath PUVA, taken together with the previous report showing no increase in the risk of squamous cell carcinoma or cutaneous malignant melanoma after TMP bath PUVA, suggests that TMP bath PUVA is an effective and safe therapeutic option.

Adolescent↗

Lung parasites of least weasels in Finland.

Because of their constant exposure to normal rodent definitive hosts, least weasels (Mustela nivalis) were trapped in southern Finland in late fall 1994 and examined for lung parasites. Histological examination showed that 46% of the weasels (n = 46) were infected with adiaspores identified as Chrysosporium sp. Granulomas surrounding the adiaspores consisted of mostly unorganized layers of mononuclear cells. The adiaspores from least weasels were much smaller than those reported from their prey animals. Infection with Pneumocystis carinii also was found in two weasels.

Animals↗

Prevalence of allergic diseases in schoolchildren in relation to family history, upper respiratory infections, and residential characteristics.

The prevalences of asthma, allergic rhinitis (AR), and eczema were analyzed in relation to retrospective risk factors from birth in a questionnaire study of schoolchildren in two areas covering the whole climatic span of Sweden: the Göteborg area on the southwestern coast (7-year-olds, n = 1649) and Kiruna, a mining town in the northernmost inland mountains (7-9-year-olds, n = 832). The strongest background factor, a family history of the diseases, was more common in children with another strong risk factor, particularly for asthma: high frequency of upper respiratory tract infection (URTI). Other significant risk factors related to high indoor humidity caused an increased prevalence of both allergic diseases and URTI. Active mechanical ventilation of the homes caused a slight reduction of the prevalence of allergic diseases, and repainting or new wallpaper in the bedroom of the child after birth caused a moderately increased risk of allergic disease. This study illustrates the interaction between genetic and environmental risk factors with special emphasis on factors related to an unventilated indoor climate, which may have substantially contributed to the current increase of the diseases in the country.

Child↗

Facial skin symptoms in visual display terminal (VDT) workers. A case-referent study of personal, psychosocial, building- and VDT-related risk indicators.

BACKGROUND: The Office Illness Project in northern Sweden, comprising both a screening questionnaire study of 4943 office workers and a case-referent study of facial skin symptoms in 163 subjects was recently completed. Previously published results from the survey showed that female gender, asthma/rhinitis, high psychosocial work load, visual display terminal (VDT) and paperwork were related to an increased prevalence of facial skin symptoms. METHODS: The case-referent study presented in this paper used data from the questionnaire supplemented by information from a clinical examination, a survey of psychosocial factors at work, building data and VDT-related factors from inspection and measurements taken at the work site. RESULTS: Psychosocial conditions and exposure to electromagnetic fields or conditions associated with such factors were related to an increased occurrence of skin symptoms. The results also indicated that personal factors such as atopic dermatitis and physical exposure factors influencing indoor air quality, such as paper exposure and cleaning frequency were related to an increased prevalence of symptoms. CONCLUSIONS: The results suggest that skin symptoms reported by VDT users have a multifactorial background.

Administrative Personnel↗

Ventilation in homes infested by house-dust mites.

Thirty single-family homes with either high (> or = 2000 ng/g) or low (< or = 1000 ng/g) house-dust mite (HDM) allergen levels in mattress dust were examined for ventilation, thermal climate, and air quality (formaldehyde and total volatile organic compounds (TVOC). Elevated concentrations of HDM allergen in mattress and floor dust were associated with the difference in absolute humidity between indoor and outdoor air, as well as with low air-change rates of the home, particularly the bedroom. No correlation was found between concentration of TVOC or formaldehyde in bedroom air and HDM allergen concentration. In regions with a cold winter climate, the air-change rate of the home and the infiltration of outdoor air into the bedroom appear to be important for the infestation of HDM.

Air Pollution, Indoor↗

The Sick Building Syndrome (SBS) in office workers. A case-referent study of personal, psychosocial and building-related risk indicators.

BACKGROUND: The Office Illness Project in Northern Sweden, comprising both a screening questionnaire study of 4943 office workers and a case-referent study of Sick Building Syndrome (SBS) in 464 subjects was recently completed. Previously published results from the survey showed that female gender asthma/rhinitis, high psychosocial work load, paper and visual display terminal (VDT) work were related to an increased prevalence of SBS symptoms. METHODS: The case-referent study presented in this paper used data from the questionnaire supplemented with information from a clinical examination, a survey of psychosocial factors at work building data from inspection and measurements taken at the work sites. RESULTS: Personal factors such as atopy and photosensitive skin, psychosocial conditions and physical exposure factors influencing indoor air quality (IAQ), such as outdoor air flow rates and the presence of photocopiers were related to an increased prevalence of the reported SBS symptoms. The results were established using multivariate analysis. CONCLUSIONS: The rate response relationship between actually measured ventilation rates and the prevalence of perceived SBS symptoms presents strong evidence for the association between IAQ factors and health.

Adult↗

Mite allergens during 18 months of intervention.

In Stockholm, Sweden, 17 children with newly diagnosed sensitization to house-dust mites (HDM) and 11 children with previously diagnosed HDM-sensitization were included in a study of HDM-allergen avoidance. Mattress dust was collected on repeated occasions during 18 months and assayed for concentration of major HDM allergens. During the first 12 months, the parents of the intervention group were instructed to intensify cleaning and airing of the child's bedroom. During the last 6 months of the study, the mattresses and pillows of seven children in the intervention group and sibling controls were encased in semipermeable polyurethane covers. The homes exhibited a high absolute indoor humidity throughout the year, and even during the winter the mean levels exceeded 7 g/kg. No mite allergen reduction was seen in the intervention group during the first year. However, among the newly diagnosed HDM-sensitized children, there was a mean reduction of the mattress mite allergen concentration of 83% (P = 0.02), and this was most pronounced in the homes with low humidity. At the end of the mattress encasement period, an average difference of 98% (P < 0.001) was found between the vacuumed amount of mite allergen on top of the covers and that underneath.

Adolescent↗

Indoor viable dust-bound microfungi in relation to residential characteristics, living habits, and symptoms in atopic and control children.

Floor dust was collected in the wintertime from the homes of 61 children sensitized to house dust mites, 57 children with sensitization to other aeroallergens, and 57 nonatopic control children. The dust was cultivated and microfungal growth was identified microscopically. Indoor humidity was measured, and condensation on windowpanes was registered during 1 winter week. Housing and sociodemographic and symptom data were obtained by a questionnaire. Penicillium, Alternaria, and Cladosporium were the three most common microfungi. The mean total number of colony-forming units per 30 mg of dust was significantly lower in the homes of the two atopic groups than in homes of the control group, which may be a result of allergen-sanitation measures. High colony-forming unit counts appeared to be related to damp housing. Weak associations were found between the occurrence of viable fungi in dust and allergic symptoms among the house dust mite-sensitized children. However, no consistent association between viable mold growth and sensitization to molds was observed. The health implications of indoor fungal exposure still remain unclear.

Adolescent↗