Non-invasive observation of acetyl-group buffering by 1H-MR spectroscopy in exercising human muscle.

The observation of a previously unidentified peak in localized 1H magnetic resonance (MR) spectra of human muscle during and after a work load is reported. Basic NMR properties of this resonance, as well as physiologic circumstances of its observation, suggest that it is due to the acetyl group of acetylcarnitine. The relatively large pool of muscular carnitine acts as a buffering system stabilizing the ratio of acetylated to free coenzyme A. Free carnitine can be acetylated to a large extent whenever a mismatch occurs between the fluxes through pyruvate dehydrogenase and the TCA cycle. Results of initial applications of 1H MR spectroscopy in several muscles and under different exercise regimens are in agreement with earlier invasive measurements of acetylcarnitine. It is demonstrated that the detailed dynamics of acetyl group formation are now likely to be observable non-invasively in humans by localized 1H magnetic resonance spectroscopy on standard MR imaging systems, and that acetylcarnitine buffering as a function of exercise type, oxygenation states, diet and pathology could thus be studied repeatedly and in various muscle groups with much improved temporal resolution.

Acetylation↗

Restoration of electrophysiological signals distorted by inductive effects of magnetic field gradients during MR sequences.

A generally applicable method for almost complete suppression of signal artifacts on electrophysiological signals caused by B0-gradient switching (gradient noise) is presented. The method is demonstrated for electrocardiograms (ECGs) but can also be used for other electrophysiological signals. It takes advantage of the fact that under certain conditions, the effect of switching the B0-field gradient upon an electrophysiological signal can be modeled as a linear time-invariant system and fully characterized by pulse response functions. It is shown how the system's pulse response functions of the X, Y, and Z gradients can be determined and how gradient noise can be eliminated efficiently. The elimination of gradient noise by the proposed method causes in the current arrangement a constant delay of 128 msec, which is acceptable for patient monitoring and magnetic resonance sequence triggering.

Artifacts↗

Methods and reproducibility of cardiac/respiratory double-triggered (1)H-MR spectroscopy of the human heart.

Localized (1)H-MR spectroscopy is sensitive to motion and has mostly been applied to the brain. For the human heart, cardiac and respiratory motion lead to displacements on the order of the localized voxel and lead to substantial variations of voxel content, lineshape, water suppression, and signal phase and amplitude. Combined respiratory and cardiac double triggering can avoid these complications to a large extent. Three methods of double triggering are evaluated, with reproducibility established in nine subjects for a method based on respiratory modulation of the ECG amplitude and a visual feedback mechanism. Quantitated with respect to water, within-subject reproducibilities for this setup were 9% for trimethylammonium compounds, 10% for creatine/phosphocreatine, and 13% for lipids. ANOVA showed significant differences between subjects which may relate to natural variability between subjects or exact location within the heart. Unresolved issues for this technique are its susceptibility to precise placement of ECG electrodes and the reasons for failure in 20% of examination. With this technique it is possible to investigate open questions in cardiac pathophysiology, such as the creatine content in chronic heart disease. Variants of this triggering method may also improve cardiovascular MRI methods relying on data acquired in several heartbeats. Magn Reson Med 42:903-910, 1999.

Adult↗

Effect of exercise on the creatine resonances in 1H MR spectra of human skeletal muscle.

1H MR spectra of human muscles were recorded before, during, and after fatiguing exercise. In contrast to expectations, it was found that the spectral contributions of creatine/phosphocreatine (Cr/PCr) were subject to change as a function of exercise. In particular, the dipolar-coupled methylene protons of Cr/PCr were found to be reduced in intensity in proportion to the co-registered PCr levels. Recovery after exercise and behavior under ischemic conditions provide further evidence to suggest that the contributions of the CH2 protons of Cr/PCr to 1H MR spectra of human muscle in vivo reflect PCr rather than Cr levels. Variation of experimental parameters showed that this effect is not due to a trivial change in relaxation times. At present it can only be speculated about why the Cr resonances have reduced NMR visibility. If temporary binding to macromolecules should be involved, the free Cr concentration-important for equilibrium calculations of the creatine kinase reaction-might be different from what was previously assumed.

Adult↗

Observation of intramyocellular lipids by means of 1H magnetic resonance spectroscopy.

Magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) are being increasingly used for investigations of human muscle physiology. While MRI reveals the morphology of muscles in great detail (e.g. for the determination of muscle volumes), MRS provides information on the chemical composition of the tissue. Depending on the observed nucleus, MRS allows the monitoring of high-energy phosphates (31P MRS), glycogen (13C MRS), or intramyocellular lipids (1H MRS), to give only a few examples. The observation of intramyocellular lipids (IMCL) by means of 1H MRS is non-invasive and, therefore, can be repeated many times and with a high temporal resolution. MRS has the potential to replace the biopsy for the monitoring of IMCL levels; however, the biopsy still has the advantage that other methods such as those used in molecular biology can be applied to the sample. The present study describes variations in the IMCL levels (expressed in mmol/kg wet weight and ml/100 ml) in three different muscles before and after (0, 1, 2, and 5 d) marathon runs for a well-trained individual who followed two different recovery protocols varying mainly in the diet. It was shown that the repletion of IMCL levels is strongly dependent on the diet post exercise. The monitoring of IMCL levels by means of 1H MRS is extremely promising, but several methodological limitations and pitfalls need to be considered, and these are addressed in the present review.

Diet↗

Creatine supplementation--part II: in vivo magnetic resonance spectroscopy.

PURPOSE: Our purpose was to study effects of creatine (Cr) supplementation on muscle metabolites noninvasively by means of magnetic resonance spectroscopy (MRS) before and after supplementation with Cr or placebo. METHODS: 1H-MRS was used in a comprehensive, double-blind, cross-over study in 10 volunteers to measure Cr in m. tibialis anterior and m. rectus femoris at rest. PCr/ATP was observed in m. quadriceps femoris by 31P-MRS at rest and after exercise. RESULTS: A significant increase in total Cr was observed with Cr intake in m. tibialis anterior (+9.6 +/- 1.7%, P = 0.001) and in m. rectus femoris (+18.0 +/- 1.8%, P < 0.001). PCr/ATP showed a significant increase (+23.9 +/- 2.3%, P < 0.001) in m. quadriceps femoris at rest with Cr supplementation. Post-Cr supplementation recovery rates from exercise were significantly lower (k = 0.029 s(-1), P < 0.01) compared with postplacebo consumption (k = 0.034 s(-1)) and presupplementation (k = 0.037 s(-1)). However, higher levels of PCr/ATP at rest compensate for this reduction of the recovery rate after Cr supplementation. The increase of PCr/ATP determined by 31P-MRS correlates with the increase of Cr observed by 1H-MRS (r = 0.824, P < 0.001). CONCLUSION: Noninvasive observation of Cr and PCr after Cr supplementation shows an increase in a muscle specific manner. Higher preexercise levels of PCr/ATP at rest compensate for significantly slower recovery rates of PCr/ATP after Cr supplementation.

Adenosine Triphosphate↗

Neonatal body composition: dual-energy X-ray absorptiometry, magnetic resonance imaging, and three-dimensional chemical shift imaging versus chemical analysis in piglets.

An animal study to evaluate dual-energy x-ray absorptiometry (DXA) and magnetic resonance (MR) imaging and spectroscopy for measurement of neonatal body composition was performed. Twenty-three piglets with body weights ranging from 848 to 7550 g were used. After measuring total body water, animals were killed and body composition was assessed using DXA and MR (1.5 T; MR imaging, T1-weighted sagittal spin-echo sequence; MR spectroscopy, three-dimensional chemical shift imaging) as well as chemical carcass analysis (standard methods) after homogenization. Body composition by chemical analysis (percent of body weight, mean +/- SD) was as follows: body water, 75.3 +/- 3.9%; total protein, 13.9 +/- 8.8%; and total fat, 6.5 +/- 3.7%. Absolute content of fat and total ash was 7-674 and 35-237 g, respectively. Mean hydration of fat-free mass was 0.804 +/- 0.011 g/kg and decreased with increasing body weight (r2 = 0.419) independent of age. Using DXA, bone mineral content was highly correlated with calcium content (r2 = 0.992), and calcium per bone mineral content was 44.1 +/- 4.2%. DXA fat mass correlated with total fat (r2 = 0.961). Using MR, spectroscopy and chemical analysis were highly correlated with fat-to-water ratio (r2 = 0.984) and absolute fat content (r2 = 0.988). Total fat by MR imaging volumetry showed a lower correlation (r2 = 0.913) and overestimated total fat by a factor of 2.46. Conversion equations for DXA were developed (total fat = 1.31 x fat mass measured by DXA--68.8; calcium = 0.402 x bone mineral content + 1.7), which improved precision and accuracy of DXA measurements. In conclusion, both DXA and MR spectroscopy give accurate and precise estimates of neonatal body composition and may become valuable tools for the noninvasive assessment of neonatal growth and nutritional status.

Absorptiometry, Photon↗

Versatile frequency domain fitting using time domain models and prior knowledge.

An iterative nonlinear least-squares fitting algorithm in the frequency domain using time domain models for quantification of complex frequency domain MR spectra is presented. The algorithm allows incorporation of prior knowledge and has both the advantage of time-domain fitting with respect to handling the problem of missing data points and truncated data sets and of frequency-domain fitting with respect to multiple frequency-selective fitting. The described algorithm can handle, in addition to Lorentzian and Gaussian lineshapes, Voigt and nonanalytic lineshapes. The program allows the user the design of his own fitting strategy to optimize the probability of reaching the global least-squares minimum. The application of the fitting program is illustrated with examples from in vivo 1H-, 31P-, and 13C-MR spectroscopy.

Algorithms↗

Absolute metabolite quantification by in vivo NMR spectroscopy: IV. Multicentre trial on MRSI localisation tests.

The difference between the experimental and theoretical spatial response function (SRF) of a narrow tube with water is used for a localization test for magnetic resonance spectroscopic imaging (MRSI). From this difference a quantitative performance parameter is derived for the relative amount of signal within a limited region in the field of view. The total signal loss by the MRSI experiment and eddy currents is described by a parameter SL derived from the signal intensities of two echoes. Results of a European multi-centre trial show that this approach is suited for assessment of MRSI localization performance.

Animals↗

In vivo determination of intra-myocellular lipids in human muscle by means of localized 1H-MR-spectroscopy.

Intra-myocellular lipids (IMCL) are stored in droplets in the cytoplasm of muscle cells and are an energy storage form readily accessed during long-term exercise. 1H-MR spectroscopy methods are presented for noninvasive determination of IMCL in human muscle. This is based on (a) the separation of two resonances in the lipid-CH2-region, with the one assigned to IMCL being independent of muscle orientation relative to the magnetic field and (b) the fact that IMCL resonances scale along with signal amplitudes of metabolites in the muscle cell (e.g., creatine) when voxel size is increased, while lipid signals of bulk fat show a disproportionate growth. Inter-individual and intra-individual reproducibility studies indicate that the error of the method is about 6% and that IMCL levels differ significantly between identical muscles in different subjects, as well as intra-individually when measured at 1 week intervals. IMCL determinations in a single subject before and after strenuous exercise indicate that lipid stores recover with a t1/2 of about 1 day.

Adult↗

Quality assessment in in vivo NMR spectroscopy: V. Multicentre evaluation of prototype test objects and protocols for performance assessment in small bore MRS equipment.

This paper reports the results of multicentre studies aimed at designing, constructing, and evaluating prototype test objects for performance assessment in small-bore MRS systems, by utilizing the test protocols already proposed by the EEC COMAC-BME Concerted Action for clinical MRS equipment. Three classes of test objects were considered: (1) a multicompartment test object for 31P MRS measurements performed with slice-selective sequences; (2) a two-compartment test object for volume-selection 1H MRS; and (3) two-compartment test objects for assessing the performance of experimental systems using ISIS as volume localization sequence in 31P MRS. The results suggested the interest of adopting some of these prototypes for improving the comparison of spectroscopy data obtained from different sites, for providing useful means of quality assurance in experimental MRS, and facilitating the validation of new localization sequences.

Magnetic Resonance Spectroscopy↗

Spatially selective RF pulses and the effects of digitization on their performance.

Spectrometers make use of D/A converters to generate RF and gradient shapes. This paper examines by exact simulations the time and amplitude digitization effects, inherent to the use of D/A converters, on the performance of amplitude modulated (AM) frequency selective RF pulses. By making use of Fourier theory and the small tip angle approximation, an approximate model of these effects on the magnetization slice profiles is derived and verified for several pulse types by computer simulations. This approximate model will be used to derive requirements for D/A converters with respect to spatial localization. The dynamics of the spin system allows pulse width modulation (PWM) as an alternative to AM for pulse envelope encoding. The effects of PWM on the slice profile are examined and compared with conventional AM pulses. It is shown by simulation and measurement that adiabatic PWM pulses can be found. In contrast to AM modulated adiabatic pulses, adiabatic PWM pulses have side bands with the same slice quality as the main slice and might therefore be useful as multislice selective pulses.

Magnetic Resonance Spectroscopy↗