Search PubMedSearch

Biomedical subjects

J Skiba

Publications and source records attributed to J Skiba.

6 recordsLinked to original sources

Biocompatibility of extracorporeal circulation with autooxygenation.

Platelet damage, complement activation and neutropenia during cardiopulmonary bypass are the result of blood contact with artificial surfaces, mainly in the oxygenator. To evaluate biocompatibility of this kind of bypass we compared two techniques of extracorporeal circulation in 40 patients undergoing elective coronary bypass operations. In 20, a standard technique with a bubble oxygenator was used (group 1), and in the remaining 20 patients with autooxygenation, the patients' own lungs were included in the perfusion circuit (group 2). Several blood samples were taken before, during and after perfusion to estimate the corrected platelet numbers and pulmonary leucocyte sequestration in all patients, and additionally in 6 patients from each group, complement C3a and C5a anaphylatoxins were measured (radioimmunoassay). At the end of cardiopulmonary bypass, the decline of platelet number corrected to haematocrit platelet number in group 1 was significantly higher than in group 2 (P less than 0.01). There was a significant increase in circulating white blood cells when compared to pre-bypass time in both groups (P less than 0.05). However, comparison of differences between leucocyte counts in the blood of the patients' right and left atria showed enhanced leucocyte sequestration in group 1, 1.46 +/- 0.5 x 10(3)/mm3 vs only 0.34 +/- 0.2 x 10(3)/mm3 in group 2. The C3a rose progressively during extracorporeal circulation: in group 1 from 268 +/- 46 ng/l to 521 +/- 65 ng/l, and in group 2 from 244 +/- 46 ng/l to 418 +/- 34 ng/l (P less than 0.05). No characteristic changes in C5a activation were observed in either group.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood Loss, Surgical

[Use of cardiopulmonary bypass decreases leukocyte count and activation of the complement system].

Platelet damage, complement activation and neutropenia during extracorporeal circulation are the result of blood contact with artificial surfaces, mainly in the oxygenator. To evaluate the biocompatibility of the ++auto-oxygenation technique of cardiopulmonary bypass (CPB) 2 techniques of extracorporeal circulation were compared in 40 patients undergoing elective coronary bypass surgery. Patients were studied in 2 groups, 20 patients in each: I (++auto-oxygenation --patients lungs used in CPB) and II (conventional technique of CPB with bubble oxygenator). Several blood samples were taken before, during and after perfusion to estimate pulmonary leukocytes sequestration in all patients and additionally complement C3a and C5a anaphylatoxins + were measured (radioimmunoassays) in 6 patients of each group. During cardiopulmonary bypass the decline in leukocyte number was observed in both groups, but leukocyte count was higher in group I then II, due to the transpulmonary leukocyte sequestration which was higher in group II. The difference between leukocytes count in group II was 1.46 +/- 0.5 x 10(3)/mm3 vs only 0.34 +/- 0.2 x 10(3)/mm3 in group I, p less than 0.001. In postoperative period an increase in circulating white blood cells was observed in both groups when compared to pre-bypass time, but the difference between groups was non significant. The level of C3a increased in group I from 244 +/- 46 ng/ml to 418 +/- 34 ng/ml, in group II from 268 +/- 46 ng/ml to 521 +/- 65 ng/ml, p less than 0.001, but in group I the levels were significantly lower, p less than 0.001. The current study confirms that cardiopulmonary bypass results in significant leukocyte and complement activation and supports the theoreticaly better biocompatibility of CPB with lung over oxygenator.

Adult

[Personal observations with application of auto-oxygenation techniques in the surgical management of coronary disease].

There were presented operative technique and clinical results of extracorporeal circulation (ECG) with patients lungs utilization, instead of routinely applied artificial blood oxygenators. Auto-oxygenation method was applied in 12 patients with coronary artery disease treated by coronary artery bypass grafting (CABG). Operative procedure differs from the traditional one in two additional cannulations of pulmonary artery and left atrium. Two peristaltic pumps and incorporated in circulation blood reservoirs. Polystan 892910 allows for temporary substitution of cardiac function without lung disconnection. Lungs functioning during surgery do not render it difficult. Hypothermia enables to decrease respiration rate and tidal volume with no effect on physiological blood oxygenation and CO2 exhalation. Method assessment was based on results comparison with those obtained in patients treated by traditional method using bubble oxygenators-Venotherm 5,000. PO2, PCO2, platelets number and hemolysis extent were assessed before, in 10, 30, 60 min of ECG and just after it. Platelets activity and influence of the method on hemostatic disorders were evaluated based on clotting time by Ivy. Additionally hemostatic disorders were assessed by thoracic blood drainage volume calculated from the moment of protamine administration to drainage tubes withdrawal in average 18 hours after surgery. Laboratory parameters characteristically changing during ECG were also estimated. It was proved, that auto-oxygenation diminished negative effects of ECG. Increased platelets number, faster normalization of clotting time and decreased postoperative drainage were stated in the auto-oxygenation group. Postoperative drainage in this group was 260 +/- 60 ml in comparison with 800 +/- 100 ml of the control group. Authors consider that pulmonary function remaining during ECG positively affects on postoperative hemostasis. This method can be helpful in surgical management of coronary artery disease, especially in patients with primary coagulation disorders.

Coronary Artery Bypass