Search PubMed⌕ Search

Biomedical subjects

J Schaub

Publications and source records attributed to J Schaub.

128 records · Page 8Linked to original sources

Rubella embryopathy after previous maternal rubella vaccination.

This report concerns a boy with congenital rubella infection and features of the classical and expanded rubella syndrome who was born to a mother who had been successfully vaccinated with Cendehill vaccine seven years previously. The diagnosis of rubella embryopathy was confirmed by demonstrating rubella-specific serum IgM antibodies using four different methods, by the persistence of rubella HAI and IgG antibodies in serum taken between three and eight months of age and by the isolation of rubella virus from throat secretion, urine and blood mononuclear cells. The child died at eight-and-a-half months of age. This case is discussed in relation to the persistence of vaccine-induced immunity with particular respect to the protective quality of low levels of antibodies against intrauterine infection in the event of re-infection during pregnancy.

Adult↗

Evaluation of transit-time and electromagnetic flow measurement in a chronically instrumented nonhuman primate model.

The Physiology Research Branch at Brooks AFB conducts both human and nonhuman primate experiments to determine the effects of microgravity and hypergravity on the cardiovascular system and to identify the particular mechanisms that invoke these responses. Primary investigative efforts in our nonhuman primate model require the determination of total peripheral resistance, systemic arterial compliance, and pressure-volume loop characteristics. These calculations require beat-to-beat measurement of aortic flow. This study evaluated accuracy, linearity, biocompatability, and anatomical features of commercially available electromagnetic (EMF) and transit-time flow measurement techniques. Five rhesus monkeys were instrumented with either EMF (3 subjects) or transit-time (2 subjects) flow sensors encircling the proximal ascending aorta. Cardiac outputs computed from these transducers taken over ranges of 0.5 to 2.0 L/min were compared to values obtained using thermodilution. In vivo experiments demonstrated that the EMF probe produced an average error of 15% (r = .896) and 8.6% average linearity per reading, and the transit-time flow probe produced an average error of 6% (r = .955) and 5.3% average linearity per reading. Postoperative performance and biocompatability of the probes were maintained throughout the study. The transit-time sensors provided the advantages of greater accuracy, smaller size, and lighter weight than the EMF probes. In conclusion, the characteristic features and performance of the transit-time sensors were superior to those of the EMF sensors in this study.

Animals↗