Search PubMed⌕ Search

Biomedical subjects

J S Swan

Publications and source records attributed to J S Swan.

At least 37 records · Page 2Linked to original sources

MR angiography of the pelvis with variable velocity encoding and a phased-array coil.

PURPOSE: To evaluate the feasibility of an automated variable velocity-encoding sequence and improve the signal-to-noise ratio (S/N) on magnetic resonance angiograms with use of phase contrast and a pelvic phased-array coil. MATERIALS AND METHODS: Three cardiac-gated, two-dimensional (2D), phase-contrast (PC) sequences were evaluated in 10 healthy subjects. A 2D gated PC sequence with variable velocity encoding (velocity-optimized phase contrast [VOPC]) was compared with gated 2D PC sequences performed with high or low constant velocity encoding. S/Ns in VOPC images obtained with a pelvic phased-array coil were compared with those in VOPC images obtained with a body coil. RESULTS: Two blinded readers preferred VOPC for simultaneous display of large and small blood vessels in one acquisition compared with constant low (P = .0105) and high (P = .0067) velocity encoding and for overall image interpretation. VOPC images obtained with the pelvic coil had a 68%-100% better S/N compared with those obtained with the body coil. CONCLUSION: Use of a phased-array coil and variable velocity encoding improves depiction of segmental vascular anatomic structures of the pelvis.

Blood Flow Velocity↗

MR diagnosis of meniscal tears: analysis of causes of errors.

OBJECTIVE: MR imaging of the knee is an accurate method for diagnosing meniscal tears. However, MR findings do not always agree with surgical findings. In a retrospective study, we analyzed the various causes of incorrect MR diagnoses. MATERIALS AND METHODS: We reviewed a series of 400 MR examinations for suspected meniscal tears in which the diagnostic accuracy was 90%. In this group, we found 70 patients in whom the original MR diagnosis did not agree with the surgical findings. Three musculoskeletal radiologists independently reviewed each of the 70 MR examinations without knowledge of the original interpretation or the surgical findings. Their interpretations and the MR images then were correlated with the surgical findings. The original incorrect diagnoses were categorized as being due to unavoidable errors, errors in interpretation, or errors made because of equivocal MR findings of a tear. Unavoidable errors were defined as false-positive and false-negative diagnoses that could not be avoided, even in retrospect. RESULTS: Of the 83 original diagnostic errors made in the MR evaluation of 800 menisci, 33 (40%) were unavoidable errors, 32 (39%) were due to equivocal MR findings, and 18 (21%) were due to interpretation errors. The unavoidable errors consisted of 21 missed meniscal tears and 12 false-positive MR diagnoses. In the false-positive cases, the menisci were interpreted as torn on MR images by all three observers, but no tear was found at arthroscopy. Subtle MR findings that were equivocal for a tear caused both false-positive and false-negative diagnoses. Seven of the 18 interpretation errors occurred when normal variants were mistaken for a tear. CONCLUSION: Using conventional coronal and sagittal spin-echo MR imaging, we could not identify 21 (6%) of the 333 meniscal tears, even in retrospect. In addition, subtle findings that are equivocal for a tear may still make MR diagnosis of every torn meniscus difficult even for experienced radiologists. Unavoidable false-positive diagnoses due to healed tears or tears missed at arthroscopy are an infrequent problem occurring in only 1.5% of the original 800 menisci evaluated with MR imaging.

Diagnostic Errors↗

Generalized matched filtering for time-resolved MR angiography of pulsatile flow.

Generating flow-specific images (arteriograms, venograms) with optimal signal-to-noise ratios for time-resolved MR angiography is a conditional maximum problem, and its solutions are generalized matched filters. We have investigated six matched filters, corresponding to all possible combinations of three flow suppression conditions and two signal-to-noise ratio maximization procedures. Four of these matched filters correspond to previously described methods: the subtractive matched filter, the standard deviation, the global venous eigenimage and the global arterial eigenimage. The two others are referred to here as the local venous eigenimage and the local arterial eigenimage. These six matched filters have been applied to 2D time-resolved phase contrast angiographic data. The local arterial eigenimage is found to be the most effective in suppressing undesired venous flow and preserving desired arterial flow.

Blood Flow Velocity↗

Case report 803: Gorham's disease (Gorham-Stout syndrome) of scapula.

In summary, a 36-year-old man presented with pain and limited motion in the shoulder. Clinical examination revealed obliteration of normal scapular landmarks in the conspicuous absence of any palpable soft tissue mass. Roentgenograms showed progressive osteolysis of the scapula. Biopsy confirmed the diagnosis of Gorham's disease. MRI played a key role in defining the extent of disease involvement and in displaying the distinct soft tissue anatomy. These MRI features are to our knowledge previously undescribed.

Adult↗

Preoperative evaluation of giant cell tumors of the radius with magnetic resonance angiography.

We report three clinical cases of giant cell tumor of the distal radius in which reconstructions were performed with vascularized fibular grafts. Magnetic resonance angiography, a newer and noninvasive technique, was used in addition to preoperative magnetic resonance imaging. All patients had routine digital subtraction arteriography, with which magnetic resonance angiography compared favorably, demonstrating the carpal arch anatomy and other major vessels at the tumor site. In two patients the trifurcation vessels of both legs were also studied with magnetic resonance angiography before fibular harvest. In one case, the fibula graft was successfully harvested on the basis of the magnetic resonance angiographic findings. In the other case, digital subtraction arteriography had been done to evaluate suspected peripheral vascular disease. In that case magnetic resonance angiography correlated well with the digital subtraction arteriographic study, showing bilateral anterior tibial artery occlusions and patent posterior tibial and peroneal arteries. Magnetic resonance angiography has the potential to replace conventional angiography in preoperative evaluation of upper-extremity tumors.

Adult↗

Two forms of human milk bile-salt-stimulated lipase.

This study provides the first direct evidence for the existence of two active forms of the human milk enzyme bile-salt-stimulated lipase. Heparin-based affinity chromatography and size-exclusion chromatography were used to obtain two active forms of this enzyme with molecular masses of 97 and 120 kDa.

Chromatography, Affinity↗

Dolichol and N-linked oligosaccharide synthesis in the rat testis: interaction between Sertoli and spermatogenic cells, evidence for paracrine effects.

The relative contribution of the Sertoli cell and the pachytene spermatocyte to dolichol and N-linked oligosaccharide biosynthesis within the seminiferous tubule was investigated. Evidence is presented to show that the interaction between these two cell types affects dolichol and N-linked oligosaccharide biosynthesis. Analysis of the dolichol content of Sertoli cultures confirms earlier data suggesting that the Sertoli cell constitutes the major pool of dolichols within the seminiferous tubule. [14C]Acetate incorporation studies suggest that the Sertoli cell in culture synthesizes dolichol much more rapidly than does the isolated pachytene spermatocyte. This information, in addition to previous data in the literature, infers an interactive effect whereby the presence of the spermatogenic cell in the tubule stimulates dolichol synthesis in the Sertoli cell. The absence of normal Sertoli-spermatocyte interactions in in vitro incubations may also limit dolichol synthesis in the pachytene spermatocyte. The distribution of dolichol kinase between the Sertoli and the pachytene spermatocyte was also examined. The concentration of this enzyme in the Sertoli cell suggests the presence of an active salvage pathway within that cell. The correlation between the appearance of the pachytene spermatocyte and the previously described peak of dolichol kinase activity in the seminiferous tubules of the prepubertal animal implies cell-cell interactions. Radiolabelling studies of N-linked oligosaccharides were conducted using [3H]mannose and concanavalin A affinity chromatography to identify multiantennary, biantennary, and high-mannose oligosaccharide pools. An in vitro bicameral coculture system was used to demonstrate that pachytene spermatocytes stimulate incorporation of [3H]mannose into Sertoli cell oligosaccharides.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Peripheral MR angiography with variable velocity encoding. Work in progress.

An electrocardiographically triggered two-dimensional phase-contrast (PC) magnetic resonance angiographic pulse sequence was developed in which velocity encoding (VENC) was varied throughout an acquisition in response to changes in blood velocity during the cardiac cycle. This was done to better capture signal in the peripheral vasculature, where pulsatile flow degrades images. After reconstruction, a matched filter addition technique was applied to the cardiac phase images to obtain a single high-quality static image. Images were obtained of six healthy volunteers--with and without varying VENC--and contrast-to-noise ratio (C/N) calculations were performed for the added images. Varying VENC significantly improved vascular signal from small and large vessels (P less than .02), but it was most helpful for small vessels, for which the C/N increased by as much as 260% (average increase, 149%). These preliminary findings suggest that variable VENC can enhance the signal from the small and large peripheral blood vessels in cardiac-gated PC acquisitions.

Angiography↗

Contrast and nuclear arthrography in loosening of the uncemented hip prosthesis.

The recent popularity of ingrowth or uncemented hip arthroplasties has presented problems in the radiographic diagnosis of loosening because there is no longer a cement interface in which lucencies may be seen. We evaluated a combination of positive contrast and nuclear arthrography to see whether these studies could accurately detect loosening of uncemented femoral components of hip prostheses. We performed routine contrast and nuclear arthrography in 21 patients with ingrowth total hip arthroplasties or bipolar endoprostheses. The results were surgically confirmed in 12 patients. The contrast arthrogram was true positive in 5 and false negative in 5. There were no false positives and 2 true negatives. The nuclear arthrogram was true positive in 7 patients, false negative in 3, and true negative in 2. Taken together, there was only 1 patient in whom both contrast and nuclear arthrography were false negative, and there were no false positives. Thus, when either contrast or nuclear arthrography is positive, the sensitivity of the combined procedures is 90%; when both studies are negative, the specificity is 100%. The combination of contrast and nuclear arthrography is an accurate method of determining loosening of the femoral component of an uncemented hip arthroplasty or bipolar endoprosthesis in the patient with postoperative hip pain.

Adult↗

Evaluation of joint disease in the adult hand and wrist.

The radiographic evaluation of joint diseases in the adult hand and wrist is described in this chapter. The main focus is on the interpretation of plain radiographs of the hands and wrists in patients with joint symptoms. After considering the general approach to the analysis of the radiographs, the findings of the common forms of arthritis are illustrated and the differential diagnoses are discussed.

Adult↗

L-myo-inosose-1 as a probable intermediate in the reaction catalyzed by myo-inositol oxygenase.

In previous investigations, it was necessary to have Fe(II) and cysteine present in order to assay the catalytic activity of purified hog kidney myo-inositol oxygenase. In the present study it was found that, if this purified nonheme iron enzyme is slowly frozen in solution with glutathione and stored at -20 degrees C, it is fully active in the absence of activators if catalase is present to remove adventitious H2O2. With this simpler assay system it was possible to clarify the effects of several variables on the enzymic reaction. Thus, the maximum velocity is pH-dependent with a maximum around pH 9.5, but the apparent Km for myo-inositol (air atmosphere) remains constant at 5.0 mM throughout a broad pH range. The enzyme is quite specific for its substrate myo-inositol, is very sensitive to oxidants and reductants, but is not affected by a variety of complexing agents, nucleotides, sulfhydryl reagents, etc. In other experiments it was found that L-myo-inosose-1, a potential intermediate in the enzymic reaction, is a potent competitive inhibitor (Ki = 62 microM), while other inososes and a solution thought to contain D-glucodialdehyde, another potential intermediate, are weak inhibitors. Also, both a kinetic deuterium isotope effect (kH/kD = 2.1) and a tritium isotope effect (kH/kT = 7.5) are observed for the enzymic reaction when [1-2H]- and [1-3H]-myo-inositol are used as reactants. These latter results are considered strong evidence that the oxygenase reaction proceeds by a pathway involving L-myo-inosose-1 as an intermediate rather than by an alternative pathway that would have D-glucodialdehyde as the intermediate.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Liquid-chromatographic study of fluorescent materials in uremic fluids.

Using reversed-phase "high-performance" liquid chromatography with fluorescence detection, we separated and identified some naturally fluorescent compounds in uremic serum and hemodialysate from patients with chronic renal disease. Several of the naturally fluorescent compounds were identified as indole derivatives by co-chromatography with authentic standards. In one specific case, the identity was confirmed by an enzymic peak-shift method. Compounds identified included indican, kynurenic acid, tryptophan, and 5-hydroxy-indole-3-acetic acid. Comparison of normal and uremic serum showed that the fluorescent materials are present in significantly greater concentrations in samples from uremic patients.

Chromatography, High Pressure Liquid↗

Combined MRI and MRA for limb salvage planning.

Magnetic resonance angiography (MRA) was performed in two patients with primary bone neoplasms being staged for differing types of limb-salvage procedures. A gated two-dimensional (2D) phase contrast MRA sequence that is capable of variable velocity encoding throughout the cardiac cycle was used to acquire the MRA images. The resulting cardiac phase images were added with a matched filter algorithm to create a single high signal-to-noise ratio image. An SE MR image in the same plane and field of view was then added to the MRA image. This displayed the relationship of vascular and stationary tissues within a composite picture: a "2D combined angiographic-stationary tissue" image. The anatomy represented gave information equivalent to conventional angiography. While this technique is not an ideal 3D rendering, it is easier to use. Along with other SE sequences acquired as needed for staging, it provides a complete preoperative evaluation of a tumor bed or donor site for a vascularized graft harvest.

Adolescent↗