Search PubMedSearch

Biomedical subjects

J S Leigh

Publications and source records attributed to J S Leigh.

At least 19 recordsLinked to original sources

Detection of residual quadrupolar interaction in the human breast in vivo using sodium-23 multiple quantum spectroscopy.

Sodium multiple quantum (MQ) spectroscopy of the human breast in vivo was performed. Double quantum (DQ) filtered spectra were used to demonstrate the existence of a non-vanishing (residual) quadrupolar interaction in the tissue. Triple quantum (TQ) filtered spectra were used to measure the two time constants associated with the biexponential transverse relaxation times of sodium in biological tissues. The two time constants were found to be 0.64 and 26.57 msec. The potential applications of this finding are discussed.

Anisotropy

A novel approach to observing articular cartilage deformation in vitro via magnetic resonance imaging.

The design of a pressure cell that compresses a cartilage specimen in one dimension within an imaging magnet is presented. One-dimensional projection images in a direction perpendicular to the articular surface of the cartilage specimen were used to generate a uniaxial confined deformation creep curve for normal and trypsin-degraded cartilage specimens during a continuous 0.690 MPa (100 psi) pressure application. The resulting curves are shown to fit a two time constant viscoelastic model well and also indicate that the elastic modulus of cartilage decreases and the deformation rate increases upon trypsin proteolysis. Furthermore, cartilage permeability is shown as a function of cartilage strain for both the normal and trypsin-degraded case. Several two-dimensional slice-selective images were collected both before and after 80 minutes of continuous compression. These images were used to evaluate the relative changes in the spin-lattice, T1, and spin-spin, T2, relaxation time constant maps for both normal and degraded cartilage specimens in response to compression. The results of this study demonstrate the utility of a novel, non-magnetic, cartilage compression device and also support the validity of a simple two-component rheological model of articular cartilage.

Animals

Sodium NMR evaluation of articular cartilage degradation.

One of the first effects of degenerative osteoarthritis is the loss of proteoglycans from the matrix of articular cartilage. Using a model of osteoarthritic change where the cartilage has been enzymatically degraded with trypsin, the sodium NMR characteristics of the cartilage were determined as a function of changes in the proteoglycan content. The results demonstrate that the single quantum sodium signal decreases as the proteoglycan content of the cartilage matrix decreases. In addition, the relaxation characteristics of the sodium change such that the T1 is longer, the T2s is longer, and the T2f is shorter. Short echo-time, T1-weighted sodium images are presented which demonstrate that this information may be utilized to detect the loss of proteoglycans from articular cartilage.

Animals

Spectral quantitation by principal component analysis using complex singular value decomposition.

Principal component analysis (PCA) is a powerful method for quantitative analysis of nuclear magnetic resonance spectral data sets. It has the advantage of being model independent, making it well suited for the analysis of spectra with complicated or unknown line shapes. Previous applications of PCA have required that all spectra in a data set be in phase or have implemented iterative methods to analyze spectra that are not perfectly phased. However, improper phasing or imperfect convergence of the iterative methods has resulted in systematic errors in the estimation of peak areas with PCA. Presented here is a modified method of PCA, which utilizes complex singular value decomposition (SVD) to analyze spectral data sets with any amount of variation in spectral phase. The new method is shown to be completely insensitive to spectral phase. In the presence of noise, PCA with complex SVD yields a lower variation in the estimation of peak area than conventional PCA by a factor of approximately 2. The performance of the method is demonstrated with simulated data and in vivo 31P spectra from human skeletal muscle.

Analysis of Variance

An MR imaging method for simultaneous measurement of gaseous diffusion constant and longitudinal relaxation time.

A magnetic resonance imaging method for simultaneous and accurate determination of gaseous diffusion constant and longitudinal relaxation time is presented. The method is based on direct observation of diffusive motion. Initially, a slice-selective saturation of helium-3 (3He) spins was performed on a 3He/O2 phantom (9 atm/2 atm). A time-delay interval was introduced after saturation, allowing spins to diffuse in and out of the labeled slice. Following the delay interval a one-dimensional (1-D) projection image of the phantom was acquired. A series of 21 images was collected, each subsequent image having been acquired with an increased delay interval. Gradual spreading of the slice boundaries due to diffusion was thus observed. The projection profiles were fit to a solution of the Bloch equation corrected for diffusive motion. The fitting procedure yielded a value of D3He = 0.1562+/-0.0013 cm2/s, in good agreement with a measurement obtained with a modified version of the standard pulsed-field gradient technique. The method also enabled us to accurately measure the longitudinal relaxation of 3He spins by fitting the change of the total area under the projection profiles to an exponential. A value of T1 = 1.67 s (2 T field) was recorded, in excellent agreement with an inversion recovery measurement.

Diffusion

MR imaging contrast enhancement based on intermolecular zero quantum coherences.

A new method for magnetic resonance imaging (MRI) based on the detection of relatively strong signal from intermolecular zero-quantum coherences (iZQCs) is reported. Such a signal would not be observable in the conventional framework of magnetic resonance; it originates in long-range dipolar couplings (10 micrometers to 1 millimeter) that are traditionally ignored. Unlike conventional MRI, where image contrast is based on variations in spin density and relaxation times (often with injected contrast agents), contrast with iZQC images comes from variations in the susceptibility over a distance dictated by gradient strength. Phantom and in vivo (rat brain) data confirm that iZQC images give contrast enhancement. This contrast might be useful in the detection of small tumors, in that susceptibility correlates with oxygen concentration and in functional MRI.

Animals

Off-resonance proton T1rho dispersion imaging of 17O-enriched tissue phantoms.

Proton T1rho dispersion imaging is a recently described method for indirect detection of 17O. However, clinical implementation of this technique is hindered by the requirement for a high-amplitude spin-locking field (gammaB1 > 1 kHz) that exceeds current limitations in specific absorption rate (SAR). Here, a strategy is offered for circumventing high SAR in T1rho dispersion imaging of 17O through the use of low-amplitude off-resonance spin-locking pulses (gammaB1 < 300 Hz). Proton spin-lattice relaxation times in the off-resonance rotating frame were measured in H2(17)O-enriched tissue phantoms. On- and off-resonance T1rho dispersion imaging was implemented at 2 T using a spin-locking preparatory pulse cluster appended to a standard spin-echo sequence. On- and off-resonance dispersion images exhibited similar 17O-based image contrast. Magnetization transfer effects did not depend on 17O concentration and had no effect on image contrast. In conclusion, off-resonance proton T1rho dispersion imaging shows promise as a safe, sensitive technique for generating 17O-based T1rho contrast without exceeding SAR limitations.

Absorption

Sodium MRI of human articular cartilage in vivo.

Preliminary results from in vivo sodium MRI of human patellar articular cartilage are presented. Sodium images generated of an in vitro bovine patella clearly distinguish the region of proteoglycan depletion from the region of healthy cartilage. This provides the first evidence that sodium imaging may be used to detect changes due to osteoarthritis in vivo. The process of optimizing imaging time and signal-to-noise ratio, as well as potential implications in the detection of osteoarthritic change, are discussed.

Animals

MRI of hyperpolarized 3He gas in human paranasal sinuses.

In this study, MRI of hyperpolarized 3He gas in human paranasal sinuses is presented. Helium images were obtained at 1.5 T, using a surface coil and a 2D, fast gradient-echo sequence with a nominal constant flip angle of 12 degrees. Coronal images of 20-mm thick slices were generated and compared with proton images of the corresponding sections. The images enable visualization of the paranasal sinuses and the nasal cavity, suggesting a potential use of this method not only in identifying the anatomical configuration of these pneumatic spaces, but also in assessing sinus ventilation.

Adult

Sodium multiple quantum spectroscopy of articular cartilage: effects of mechanical compression.

The effects of mechanical compression on the multiple quantum coherences generated from sodium ions in articular cartilage were investigated. Cartilage samples obtained from bovine patellae were studied during compression at 0.7 MPa (100 psi) for 1 hour. The double quantum filtered spectra showed marked lineshape changes in the compressed samples. Compression did not seem to influence the lineshapes of the single quantum and triple quantum filtered spectra significantly. We found that the residual quadrupolar interaction was reduced in the compressed samples. Changes in the ordering of collagen fibers may be responsible for the observed effect.

Animals

Improved resolution and signal-to-noise ratio in MRI via enhanced signal digitization.

The high frequency k-space data in magnetic resonance imaging is often poorly reproduced due to the finite dynamic range of an analog-to-digital converter. The magnitude of this digitization error can equal and even exceed the magnitude of the thermal noise. Under such conditions, attempts to increase image signal-to-noise ratio via signal averaging meet with diminishing success. Because the relative size of the digitization error increases at higher spatial frequencies, a reduction in image resolution is incurred as well. By adjusting the level of the analog signal sampled by the analog-to-digital converter during the course of an imaging experiment, the magnitude of the digitization artifact can be greatly reduced. The results of simulations and imaging experiments are presented which demonstrate that this strategy improves both the signal-to-noise ratio and resolution of magnetic resonance images.

Artifacts

Generalized reciprocity.

The remarkable theorem of reciprocity as described by D. I. Hoult and R. E. Richards (J. Magn. Reson. 24, 71 (1976)) may be generalized to account for the near, intermediate, and radiation zone fields of a magnetic dipole. This form of reciprocity may be important when the wavelength of the NMR signal is not large compared to the distance scale of the system. In these situations the effects of interference may be significant. In addition, both the frequency dependence and distance dependence of the NMR signal amplitude are altered. In general, the distance dependence of the signal follows a weighted sum of 1/r3, 1/r2, and 1/r dependence. The frequency dependence of the signal amplitude is a function of omega, omega2, and omega3. Finally, the signal reflects the full vector field nature of the magnetic dipole. The mathematical expression of generalized reciprocity is completely equivalent to that of Hoult and Richards if the appropriate retarded potential form of the magnetic field is utilized.

Algorithms

Lactate efflux from exercising human skeletal muscle: role of intracellular PO2.

It remains controversial whether lactate formation during progressive dynamic exercise from submaximal to maximal effort is due to muscle hypoxia. To study this question, we used direct measures of arterial and femoral venous lactate concentration, a thermodilution blood flow technique, phosphorus magnetic resonance spectroscopy (MRS), and myoglobin (Mb) saturation measured by 1H nuclear MRS in six trained subjects performing single-leg quadriceps exercise. We calculated net lactate efflux from the muscle and intracellular PO2 with subjects breathing room air and 12% O2. Data were obtained at 50, 75, 90, and 100% of quadriceps maximal O2 consumption at each fraction of inspired O2. Mb saturation was significantly lower in hypoxia than in normoxia [40 +/- 3 vs. 49 +/- 3% (SE)] throughout incremental exercise to maximal work rate. With the assumption of a PO2 at which 50% of Mb-binding sites are bound with O2 of 3.2 Torr, Mb-associated PO2 averaged 3.1 +/- 0.3 and 2.3 +/- 0.2 Torr in normoxia and hypoxia, respectively. Net blood lactate efflux was unrelated to intracellular PO2 across the range of incremental exercise to maximum (r = 0.03 and 0.07 in normoxia and hypoxia, respectively) but linearly related to O2 consumption (r = 0.97 and 0.99 in normoxia and hypoxia, respectively) with a greater slope in 12% O2. Net lactate efflux was also linearly related to intracellular pH (r = 0.94 and 0.98 in normoxia and hypoxia, respectively). These data suggest that with increasing work rate, at a given fraction of inspired O2, lactate efflux is unrelated to muscle cytoplasmic PO2, yet the efflux is higher in hypoxia. Catecholamine values from comparable studies are included and indicate that lactate efflux in hypoxia may be due to systemic rather than intracellular hypoxia.

Adult

In vivo sodium multiple quantum spectroscopy of human articular cartilage.

The authors report, for the first time, sodium properties of human articular cartilage in vivo using sodium multiple-quantum-filtered methods with a surface coil. A flip angle-independent, phase-cycled pulse sequence was used to obtain triple-quantum-filtered spectra as a function of preparation time. Biexponential relaxation rates were calculated by fitting the triple-quantum-filtered spectral amplitudes to a theoretical expression. Theoretical analysis of the flip angle dependence of even rank two-quantum coherence (T2[2]), odd rank two-quantum coherence (T2[3]), and triple-quantum coherence are presented and verified against experimental results on a cartilage specimen. Sodium multiple-quantum-filtered spectral lineshapes obtained in vivo correlate well with those observed on in vitro specimens. Relaxation rates obtained from asymptomatic volunteers were found to be: T(2rise) = 1.0 + 0.12 ms, T(2decay) = 12.0 +/- 0.75 ms (mean +/- SD). The diagnostic potential of this method in detecting early changes in articular cartilage is described.

Animals

Triple quantum sodium imaging of articular cartilage.

Triple quantum (TQ) sodium imaging of bovine articular cartilage is presented. True triple quantum imaging sequence was modified to incorporate asymmetric echo acquisition. Triple quantum signal expression in the presence of residual quadrupolar interaction is presented. The filtering capability of the sequence is first demonstrated on an agarose phantom. Both single and triple quantum images of articular cartilage are compared. The TQ image shows non-zero signal intensity solely from cartilage, indicating complete suppression of signals from bone marrow and saline. The advantages of TQ imaging of articular cartilage, its feasibility in in vivo situations and further improvements in SNR are described.

Animals

A simplified sequence for observing deoxymyoglobin signals in vivo: myoglobin excitation with dynamic unexcitation and saturation of water and fat (MEDUSA).

This paper describes a new, simplified pulse sequence for observing NMR signals from deoxymyoglobin in vivo. Paramagnetically shifted resonances from deoxymyoglobin can be exploited to noninvasively calculate intracellular oxygen tension in striated muscle. However, special sequences are required to observe these weak signals against the larger water and fat signals encountered in vivo. The pulse sequence described here, which is based on inversion recovery sequences, efficiently suppresses both water and fat resonances and can be implemented with short repetition rates. Moreover, it is perfectly suited for studies with surface coils, where RF inhomogeneities render other popular suppression sequences ineffective.

Humans

T1rho-relaxation in articular cartilage: effects of enzymatic degradation.

Spin-lattice relaxation in the rotating frame (T1rho) dispersion spectroscopy and imaging were used to study normal and enzymatically degraded bovine articular cartilage. Normal specimens demonstrate significant T1rho "dispersion" (approximately 60 to approximately 130 ms) in the 100 Hz to 9 kHz frequency range. Proteoglycan-degraded specimens have 33% greater T1rho values than collagen-degraded or normal samples. T1rho-weighted images reveal structure not found in conventional T1- or T2-weighted images. Our results suggest that T1rho measurements are selectively sensitive to proteoglycan content. The potential of this method in distinguishing the early degenerative changes in cartilage associated with osteoarthritis is discussed.

Animals

17O-decoupled proton MR spectroscopy and imaging in a tissue model.

17O-decoupled proton MR spectroscopy and imaging were implemented at 2 T. Their sensitivity and accuracy in vitro were examined using semisolid tissue phantoms doped with H2(17)O. A double-tuned solenoidal coil was used to irradiate the same volume of 17O and 1H nuclei, as well as to facilitate direct calibration of the decoupling power. Decoupling efficiency was optimized as was 17O detection sensitivity. Decoupling was most efficient at RF amplitudes below 2.5 kHz (expressed as gamma [17O] x H1), which is within the limits of the acceptable specific absorption rate. Propagation of error analysis demonstrated that 17O detection sensitivity is optimal at a TE equal to the T2 of 17O-depleted water protons. Based on Meiboom's work, a simple theory was formulated for estimating the transverse relaxivity of H2(17)O and the proton signal enhancement produced by decoupling. There was excellent agreement between theory and experiment. Overall, 17O-decoupled spectroscopy and imaging were highly sensitive and accurate in quantifying H2(17)O in vitro.

Calibration