Search PubMed⌕ Search

Biomedical subjects

J Rosell-Ferrer

Publications and source records attributed to J Rosell-Ferrer.

2 recordsLinked to original sources

Thoracic versus whole body bioimpedance measurements: the relation to hydration status and hypertension in peritoneal dialysis patients.

The whole body bioimpedance technique is a highly promising non-invasive, reproducible, fast and inexpensive bed-side method for monitoring hydration status. Using segmental bioimpedance measurements, it is possible to obtain information about the fluid change in each body segment (Song, Lee, Kim and Kim 1999 Perit. Dial. Int. 19 386-90). In this pilot study we have measured 25 male patients (30-65 yr, BMI 20-32 kg m(-2)) undergoing continuous ambulatory peritoneal dialysis (CAPD). Tetrapolar impedance measurements were obtained using the right-side technique (whole body), and a segmental impedance method focused in the thorax region. Blood pressure (BP) measurements were taken manually with a sphygmomanometer. Patients were classified as either stable (group 0) or unstable (group 1) using clinical parameters of overall cardiovascular risk. The Mahalanobis distance (dM2) was calculated for the mean blood pressure (BP(mean)), and the impedance parameter R normalized by body height H for the right-side (R(RS)/H) and the thorax segment (R(TH)/H). Differences between groups were significant (p < 0.0001) for R(TH)/H and for BP(mean), and less significant (p = 0.016) for R(RS)/H. Group 1 patients showed a small dM2 as compared with a reference patient (a critical patient with acute lung edema) with high BP(mean) and low values of R(TH)/H and R(RS)/H. Moreover, Group 0 patients showed a larger dM2 with respect to the reference patient, with lower BP(mean) and higher values of R(TH)/H and R(RS)/H. All patients classified as unstable by clinical assessment were correctly classified using R(TH)/H in conjunction with BP(mean) using dM2. Segmental-monofrequency non-invasive bioimpedance of the thoracic region could provide a simple, objective non-invasive method of support for facilitating the clinical assessment of CAPD patients.

Adult↗

A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration.

We developed a 14-channel multifrequency magnetic induction tomography system (MF-MIT) for biomedical applications. The excitation field is produced by a single coil and 14 planar gradiometers are used for signal detection. The object under measurement was rotated (16 steps per turn) to obtain a full data set for image reconstruction. We make measurements at frequencies from 50 kHz to 1 MHz using a single frequency excitation signal or a multifrequency signal containing several frequencies in this range. We used two acquisition boards giving a total of eight synchronous channels at a sample rate of 5 MS s(-1) per channel. The real and imaginary parts of DeltaB/B(0) were calculated using coherent demodulation at all injected frequencies. Calibration, averaging and drift cancellation techniques were used before image reconstruction. A plastic tank filled with saline (D = 19 cm) and with conductive and/or paramagnetic perturbations was measured for calibration and test purposes. We used a FEM model and an eddy current solver to evaluate the experimental results and to reconstruct the images. Measured equivalent input noise voltage for each channel was 2 nV Hz(-1/2). Using coherent demodulation, with an integration time of 20 ms, the measured STD for the magnitude was 7 nV(rms) (close to the theoretical value only taking into account the amplifier's thermal noise). For long acquisition times the drift in the signal produced a bigger effect than the input noise (typical STD was 10 nV with a maximum of 35 nV at one channel) but this effect was reduced using a drift cancellation technique based on averaging. We were able to image a 2 S m(-1) agar sphere (D = 4 cm) inside the tank filled with saline of 1 S m(-1).

Calibration↗