Search PubMed⌕ Search

Biomedical subjects

J Ricke

Publications and source records attributed to J Ricke.

At least 19 recordsLinked to original sources

Standardisation of imaging in neuroendocrine tumours: results of a European delphi process.

In 1998 and 1999, a delphi consensus procedure was performed to establish guidelines for standardised diagnostic imaging of neuroendocrine tumours. The procedure included four consecutive workshops of a European group of experts in neuroendocrine tumours as well as feedback given by specialists from the departments of radiology, nuclear medicine, surgery and internal medicine of the according home institutions. Diverging approaches among the centres, which became apparent during the discussion, reflect a lack of controlled studies specifically for rare subgroups of neuroendocrine tumours. This paper summarises the standards for diagnostic imaging as developed during the delphi process. In particular, the diagnostic workflows as well as the technical properties of different imaging modalities are described in detail.

Delphi Technique↗

CT-guided percutaneous core biopsies of pulmonary lesions. Diagnostic accuracy, complications and therapeutic impact.

PURPOSE: To evaluate the diagnostic accuracy, complications, and therapeutic impact of CT-guided percutaneous core biopsies of pulmonary lesions. MATERIAL AND METHODS: Seventy-nine patients underwent diagnostic CT-guided percutaneous core biopsies of pulmonary lesions between July 1995 and March 1999. Evaluation included corresponding clinical data, pathologic results, and therapeutic consequences. RESULTS: There were 29 benign and 50 malignant lesions. Percutaneous core biopsy had an overall diagnostic accuracy of 95%. For malignant lesions, core biopsy was positive in 48 patients (sensitivity 96%), and for benign lesions, in 27 (sensitivity 93%). There were no false-positive findings. Pneumothoraces were observed in 19 patients (24%) and 4 of them required a chest drain (5%). There were no hematothoraces or major bleeding complications; however, postinterventional local hemorrhages were observed in 23 patients (29%). No hemoptysis was noted. CONCLUSION: Percutaneous core biopsies of pulmonary lesions offer excellent diagnostic accuracy for both benign and malignant pulmonary lesions at a low complication rate.

Adult↗

Telemedicine and its impact on cancer management.

The latest dramatic progress in the technologies of the computer industry is likely to increasingly influence the oncologist's daily routine. Besides well known and established telemedical services such as videoconferencing, the most influential trends are the spread of digital hospital infrastructures with unlimited, secured access to all relevant patient information. This article seeks to summarise the most imminent influences of telemedical developments on the future of the oncologist: the effects of telemedical services and electronic infrastructures on clinical workflow and on medical quality management. In addition, the history of telemedicine, recent technologies and the performance of electronic patient records are described.

Computer Security↗

Assessment of the vascularization of neuroendocrine tumors by stimulated acoustic emission of SH U 508A ultrasound contrast agent and color or power Doppler sonography.

RATIONALE AND OBJECTIVES: To assess the vascularization of neuroendocrine tumors by stimulated acoustic emission (SAE) of SH U 508A during the blood pool phase in comparison with contrast-enhanced Doppler sonography. METHODS: Thirty-six patients with neuroendocrine tumors received contrast-enhanced Doppler sonography and 21, an additional SAE. To classify tumor perfusion on Doppler sonography, a 4-step rating score was introduced: (1) no vessels (hypoperfusion); (2) one feeding or central vessel (hypoperfusion); (3) some vessels (hyperperfusion); and (4) disseminated vessels (hyperperfusion). In 36 patients, 1 pancreatic primary tumor, 33 liver metastases, 1 splenic metastasis, and 1 lymph node metastasis were examined. Results were correlated with biphasic spiral CT (n = 35) and angiography (n = 2). RESULTS: Arterial-phase CT and digital subtraction angiography revealed 18 hyper- and 18 hypoperfused lesions. Contrast-enhanced Doppler correctly classified 15 of 18 patients (83%) with hyperperfused lesions as well as 16 of 18 (89%) hypoperfused tumors by applying the rating score. SAE correctly identified 4 of 9 hyperperfused lesions (44%), 2 were isoperfused compared with normal liver tissue (22%), and 3 were hypoperfused (33%). Of 12 hypoperfused lesions, 11 were classified correctly (92%), and 1 showed isoperfusion. Hence, the positive and negative predictive values for SAE were 80% and 69%, respectively. For contrast-enhanced Doppler sonography, positive and negative predictive values were 88% and 84%, respectively. CONCLUSIONS: Blood pool SAE failed to determine subtle tumor perfusion correctly. The rating score for contrast-enhanced Doppler sonography characterized tumor perfusion with high accuracy. The use of a contrast agent significantly improved perfusion characterization.

Angiography, Digital Subtraction↗

Preoperative contrast-enhanced MRI of the parathyroid glands in hyperparathyroidism.

RATIONALE AND OBJECTIVES: To evaluate the sensitivity of contrast-enhanced MRI in the preoperative detection of abnormal parathyroid glands in patients with clinical evidence of hyperparathyroidism. METHODS: Twenty-eight patients with biochemical evidence of hyperparathyroidism underwent contrast-enhanced preoperative MRI of the parathyroid glands. Two blinded readers assessed the MR images by consensus, and MR results were subsequently correlated with those from surgery (location, diameter, weight) and histopathology. RESULTS: MRI depicted 32 of 39 surgically proved abnormal parathyroid glands (sensitivity 82%; 95% confidence interval, 66%-92%), and 1 of 114 (0.9%) was incorrectly considered abnormal. All ectopic glands were correctly identified (2 mediastinal, 1 submandibular). Sensitivity was superior for adenomas but less for hyperplasia (adenomas 87%; 95% confidence interval, 67%-97%; hyperplasia 75%; 95% confidence interval, 47%-92%). Among all lesions, atypical signal characteristics on MRI were observed in 34% of lesions (9% hyperintense signals on T2- and T1-weighted images; 25% isointense signals on T2- and T1-weighted images), with improved lesion detection after contrast administration in 17% of lesions. CONCLUSIONS: MRI of the parathyroid glands presented a sensitive imaging modality, thus demonstrating its high potential to preoperatively detect abnormal glands. Moreover, in a minor proportion of patients with atypical parathyroid lesion characteristics, contrast administration may increase lesion detectability.

Adenoma↗

Primary mucinous adenocarcinoma of the appendix: a rare entity in the differential diagnosis of ovarian cancer.

We report a 58-year-old female patient with the suspected diagnosis of ovarian cancer. Upon surgical exploration, examination of the appendix revealed the histological diagnosis of primary mucinous adenocarcinoma. This is an unusual consideration in the differential diagnosis of the ovarian cancer. We discuss the diagnosis, classification and treatment of the cancer of the appendix in relation to ovarian cancer.

Adenocarcinoma, Mucinous↗

Imaging procedures in neuroendocrine tumours.

PURPOSE: To give recommendations for diagnostic imaging workflow in suspected neuroendocrine tumours. MATERIALS AND METHODS: Recommendations for imaging workflow were elaborated by consensus of researchers in neuroendocrine tumours. RESULTS: Workflow charts are presented for: (1) nonfunctional and functional endocrine tumours of the pancreas (except insulinoma); (2) insulinoma; (3) ECL cell tumour; (4) assessment of unknown primaries in functional and nonfunctional neuroendocrine tumours of the gut; (5) assessment of metastases in functional and nonfunctional neuroendocrine tumours of the gut. CONCLUSIONS: The workflow charts facilitate diagnosis of neuroendocrine tumours as well as the design of controlled studies.

Diagnostic Imaging↗

A windows based viewing application for image postprocessing in DICOM format.

OBJECTIVE: To design, implement and evaluate a PC-based medical viewing application including image postprocessing for DICOM images for use within an existing hospital infrastructure. MATERIAL AND METHODS: A user-friendly DICOM compliant viewing application including image postprocessing (spatial frequency and contrast enhancement) and HL7 communication ability was designed and implemented on PC basis to run under Windows OS. To assess its quality compared to high-end workstations, an ROC analysis was performed. RESULTS: The use of image postprocessing on a PC significantly improved the perception of low-contrast details in computed radiographs. Review at a radiological workstation was superior to review at a PC with image postprocessing.

Computer Communication Networks↗

[Fat-saturated, contrast-enhanced spin-echo sequences in the magnetic resonance tomographic diagnosis of peritoneal carcinosis].

PURPOSE: To evaluate contrast-enhanced, fat-saturated spin echo sequences for the detection of peritoneal carcinosis with MRI. MATERIALS AND METHODS: 61 patients, 35 with and 26 without peritoneal carcinosis, were examined with abdominal MRI. Fat-saturated, T1-weighted spin echo sequences were performed before and after administration of Gd-DTPA. In addition, 22 patients with peritoneal carcinosis were examined with contrast-enhanced abdominal CT. RESULTS: 32 of 35 patients with peritoneal carcinosis demonstrated contrast enhancement of the visceral and 30 of 35 enhancement of the parietal peritoneum (91 and 86%, respectively). Wall thickening of the intestine or parietal peritoneum were noted in 21 and 20 of 35 patients (60 and 57%, respectively), ascites in 18 of 35 patients (51%). False positive contrast enhancement of the peritoneum was noted in 4 of 26 patients (15%). In the direct comparison of MRI and CT, 22 of 22 patients versus 7 of 22 patients showed contrast enhancement of the visceral peritoneum (100 and 32%, respectively). For other signs of peritoneal carcinosis (e.g., ascites, peritoneal seedings), no differences in diagnostic reliability were demonstrated. CONCLUSIONS: The use of fat-saturated, spin echo sequences facilitates the diagnosis of peritoneal carcinosis by artifact reduction and improved detection of peritoneal contrast enhancement. MRI with fat-saturated sequences was superior to CT.

Adult↗

Staging and monitoring of malignant lymphoma of the bone: comparison of 67Ga scintigraphy and MRI.

UNLABELLED: The aim of this study was two-fold: to compare 67Ga scintigraphy with MRI (a) for the staging of malignant lymphoma of the bone and (b) with regard to accuracy in detecting residual disease after first-line chemotherapy for restaging. METHODS: Twenty-one patients with 36 malignant osseous lesions were examined, including 7 patients with primary or multifocal osseous lymphoma and 14 patients with malignant lymphoma and simultaneous or secondary involvement of the bone. After first-line therapy, MRI and 67Ga scintigraphy were performed on 13 patients. The remission status based on all clinical and radiological findings during the follow-up was used as the gold standard. RESULTS: The osseous lesions were located on the axial skeleton in 64% of patients and on the appendicular skeleton in 36%. 67Ga scintigraphy detected 77% of the osseous lesions examined by MRI. For restaging after first-line therapy, MRI had a sensitivity of 90% and a specificity of 80% when dynamic MRI information was included. There were several false-positive results as a result of the pathologic increase in signal intensity ratios of reactive hematopoietic regions after chemotherapy. For 67Ga scintigraphy, a sensitivity of 70% and a specificity of 93% were calculated. CONCLUSION: These data show that monitoring malignant lymphoma of the bone still presents diagnostic problems. Given the high sensitivity of MRI and the high specificity of 67Ga scintigraphy but the limited specificity of MRI and sensitivity of 67Ga scintigraphy, both methods are valuable but should be used as complementary diagnostic tools.

Adolescent↗

[Comparative findings of digital thoracic images and digital images of statistical phantoms as film copy, a radiological work station and a PC].

INTRODUCTION: An ROC analysis was carried out in order to determine the reliability of digital luminescence radiography review at a PC and this was compared with a radiological work station and with X-ray film on a viewing box. MATERIAL AND METHOD: 54 chest images obtained by digital luminescence radiography were selected, 31 of these contained small pulmonary nodules. In order to evaluate critical detail, five images of a phantom showing round foci were used. Five radiologists examined these, using a Siemens Magic View work station, a PC with proprietary software (ViewMed) and X-ray films on a viewing box. Image processing of the work station used the standard clinical application. ViewMed performs linear scaling of grey levels to 8 Bit. The results were examined statistically by means of a t-test. RESULTS: As far as the chest images were concerned there was no significant difference in the diagnostic value of these methods. There was, however, a highly significant loss of diagnostic information with respect to the round focus phantom when using the PC compared with the other methods. CONCLUSION: In the configuration in which it was used, the PC should not be relied on as a primary means of examination since critical details cannot always be seen. In routine use these play a subordinate role and there was no significant diagnostic loss where the chest images were concerned. We expect that by improvements in the frequency and contrast processing the PC accuracy will be considerably increased.

Humans↗

Wavelet versus JPEG (Joint Photographic Expert Group) and fractal compression. Impact on the detection of low-contrast details in computed radiographs.

RATIONALE AND OBJECTIVES: The aim of this study was to evaluate different lossy image compression algorithms in direct comparison. METHODS: Computed radiographs were reviewed after compression with Wavelet, Fractal, and Joint Photographic Expert Group (JPEG) algorithms. For receiver operating characteristic (ROC) analysis, 54 thoracic computed radiographs (31 showing pulmonary nodules) were compressed with a ratio of 1:60. Five images of a test-phantom were coded at 1:13. All images were reviewed on a PC. Uncompressed images were reviewed at a PC and at a radiologic workstation (with image processing). RESULTS: For thorax images, decrease of diagnostic accuracy was significant with Wavelets. Fractal performed worse than Wavelets. No ROC curve was observed for JPEG due to poor image quality. No diagnostic loss was noted comparing PC and Workstation review. For low-contrast details of the phantom, results of Wavelet compression were equal to uncompressed images. Fewer true positives and increased true negatives were noted with Wavelets though. Wavelets were superior to JPEG, and JPEG images were superior to Fractal. Workstation review was superior to PC review. CONCLUSIONS: Only Wavelets provided accurate review of low-contrast details at a compression of 1:13. Frequency filtering of Wavelets affects contrast even at a low compression ratio. JPEG performed better than Fractal at low and worse at high compression ratio.

Algorithms↗

[How certain is teleradiological telediagnosis for the tomographic procedure?].

PURPOSE: To define the value of teleradiographic studies, a comparison was carried out between digitised copies of CT examinations of the skull with the original images. Differences in image quality obtained from a digital scanner and a camera were quantified. MATERIAL AND METHOD: 56 CT examinations of the skull, 28 of which had discrete abnormalities, were chosen for ROC analysis. The original films were digitised with a Vidar VXR-12 scanner and Panasonic WV-160 and WV-BP 500 cameras. The images were evaluated by five radiologists after image transfer with Video Conference software to a personal computer. RESULTS: For the analysis of the films the area under the ROC curve was 0.91 +/- 0.04, for the digital scanner it was 0.85 +/- 0.04, for camera WV-BP 500 0.89 +/- 0.06 and for camera WE-160 0.87 +/- 0.09. Comparison with the film findings showed. a minimal p-value of 0.17 which indicated that there was no significant reduction in diagnostic value following digitization. CONCLUSION: The probable reason for the slight deterioration using the digital scanner was the reduction to 75 dpi compared with 134 dpi on the CT films. The cameras produce image noise comparable to CT with low window settings and reduced local resolution. We expect similar results for CT with soft tissue windows or for MRT of the skull. Conventional radiographs containing high local resolution, wide grey scale and low image noise would presumably make higher demands on methods of digitization.

Computers↗

[Dynamic computerized tomography of the bone marrow of normal and pathologic vertebrae].

PURPOSE: The contrast medium dynamics of normal and abnormal bone marrow was examined by CT. MATERIAL AND METHOD: Standardised sections of lumbar vertebrae were obtained after intravenous injection of 80 ml Ultravist 370 and time-density curves of the marrow spaces were calculated in 38 patients. RESULTS: Time-density curves of patients with normal bone marrow differed significantly from those with proliferative bone marrow diseases in respect of maximal density and uptake at 120 and 240 seconds. Patients treated by radiation showed reduced uptake. CONCLUSION: Variations in the time-density curves between normal and abnormal bone marrow provided evidence of different perfusion and uptake of the contrast medium in the extracellular space of the bone marrow. Further investigation will be necessary to determine whether dynamic CT is able to document the effect of radiotherapy or chemotherapy on malignant bone marrow infiltration.

Adenocarcinoma↗

[Use of Ga-67 SPECT in patients with malignant lymphoma after primary chemotherapy for further treatment planning: comparison with spiral CT].

PURPOSE: To compare the diagnostic value of gallium scintigraphy using a SPECT technique with spiral CT for evaluating activity following chemotherapy in patients with malignant lymphoma and to determine treatment options. MATERIAL AND METHOD: The results of gallium scintigraphy in 28 patients with malignant lymphoma (19 Hodgkin's disease, 9 high grade non-Hodgkin's lymphoma) following curative treatment were compared with the CT morphology in relation to inactive regions and residual masses. RESULTS: Ga-67-SPECT proved superior to CT for evaluating the activity in 85 initially involved nodes (sensitivity 94.4% against 83.3%; specificity 100% against 92.5%). It was, however, inferior for demonstrating organ involvement in 28 instances. In seven patients with residual masses, Ga-67-SPECT directly affected staging and further therapy. CONCLUSION: The increasing use of secondary treatment schemes for curative purposes makes Ga-67-SPECT a suitable method for the early recognition of residual activity in Hodgkin's disease and high grade non-Hodgkin's lymphoma.

Adult↗

["Second opinion" in online radiology via Internet: report on implementation and analysis of reliability of findings in sectional images].

Numerous medical on-line services have already been established in the world-wide internet. In connection with the Information service TELESCAN, sponsored by the EU, a pilot project has been initiated which offers a radiological "second opinion" via the transmission of radiological findings and images that have been previously rendered anonymous. In addition to a description of the basic implementation, tests of the diagnostic certainty of the transmitted cranial computed tomographs have been performed. The CT images were digitized with a document camera, transmitted over the Internet, and then evaluated on the receiver's monitor. Both the transfer of originally generated digital image files (in ACR-NEMA or DICOM) as well as graphic files after digitization of X-ray films, for example by a document camera, is possible via electronic post (e-mail). Visualization by the receiver requires the use of current proprietary software for special medical image formats, while standard graphic formats such as GIFF or JPEG can be visualized with the usual Internet software. In an ROC analysis, 56 individual images of cranial computed tomographs, half with pathological findings such as space-occupying lesions, infarcts, or brain edema, were tested with regard to the diagnostic certainty after digitization and transmission. In comparison with the original film findings, there was a slight but statistically not significant reduction in diagnostic certainty of the images evaluated on screen after transfer via the Internet. We believe that this result is due to the low local resolution, low dynamic range, the high image noise and of CT arising from the window technique. The same parameters are probably valid for MRI. The result cannot be applied to conventional radiography including mammography because, in comparison to the mentioned image techniques, their local resolution is high and image noise is considerably lower.

Computer Communication Networks↗

Calcified brain metastases from ovarian carcinoma.

A case of calcified brain metastases from ovarian carcinoma is reported. Lesions developing during chemotherapy were thought on Ct to be parasitic and, to avoid dissemination of pathogens, biopsy was postponed. When neurological deficits progressed, MRI showed perifocal oedema and contrast enhancement. It also showed a new noncalcified focus which was biopsied, proving to be a metastasis.

Brain Neoplasms↗