Search PubMed⌕ Search

Biomedical subjects

J R Schmidt

Publications and source records attributed to J R Schmidt.

At least 19 recordsLinked to original sources

Vibrational energy relaxation of azide in water.

Vibrational lifetimes of the asymmetric stretch fundamental of azide anion in normal and heavy water have been measured experimentally, with results in the range of a few picoseconds. This is an interesting problem for theoretical study because of the competition between intramolecular (relaxation to the other excited vibrational states of azide) and purely intermolecular (relaxation to azide's ground vibrational state) pathways. In addition it is important to understand the origin of the solvent isotope effect. Building on the seminal work of Morita and Kato [J. Chem. Phys. 109, 5511 (1998)], the authors develop a simple model based on a two-dimensional description of the azide stretching vibrations. A novel aspect of their theory is the use of an "on-the-fly" optimized quantum mechanical/molecular mechanical approach to calculate the system-bath coupling. Their theoretical lifetimes are in good agreement with experiment for azide in both normal and heavy water. They find that the predominant relaxation pathway is intramolecular. The solvent isotope effect arises from the different librational frequencies in normal and heavy water.

Azides↗

Vibrational spectral diffusion of azide in water.

Vibrational spectral diffusion denotes the time-dependent fluctuations of a solute's vibrational frequencies due to local environmental dynamics. Vibrational line shapes are weakly sensitive to spectral diffusion, whereas three-pulse vibrational echoes are much more sensitive. We report here on theoretical studies of spectral diffusion of the asymmetric stretch of the azide anion in heavy water. We run a classical molecular dynamics simulation of rigid azide in rigid water, and at every time step we calculate the azide's anharmonic asymmetric stretch frequency using an optimized quantum mechanics/molecular mechanics method developed earlier. This generates a frequency trajectory, which we use to calculate the absorption line shape and integrated three-pulse echo intensity. Our results for both the line width and the integrated echo intensity are in excellent agreement with experiment. Our calculated frequency time-correlation function is in excellent agreement with experiment for long times (greater than 250 fs) but differs considerably from experiment at short times; our theoretical correlation function has a very pronounced oscillation, presumably due to intermolecular azide-water hydrogen-bond stretching dynamics.

Anions↗

On the potential of personal networks for hospitals.

OBJECTIVE: Today, there are many barriers that prevent seamless electronic voice and data communication with remote content and services that the user wants to access at a certain time and place. This is especially the case in hospitals, where the communication needs are very complex and context dependent, and where strict privacy and safety conditions apply. Personal network (PN) technology is expected to enable the various private networks of a single person to communicate seamlessly with each other, hiding underlying network complexity from the user. We have analyzed the usefulness of PNs in hospitals. METHODS: We studied the use case of a medical emergency surgery, and built a demonstrator by integrating models of the specialists' personal area networks, home networks, office networks, and a hospital network into a single virtual network. We performed user studies in various hospitals, using a combination of individual context interviews, scenario and requirements verification, guided experimenting with the demonstrator and concluding workshops. RESULTS: We show that, in case of medical emergencies, PNs can provide a means to enlist remote assistance from peers wherever they are in the world at a particular moment. It can also ease the communication between the operating theatre and the outside world, e.g. for educational purposes.

Computer Communication Networks↗

Approaches for the calculation of vibrational frequencies in liquids: comparison to benchmarks for azide/water clusters.

Ultrafast vibrational spectroscopy experiments, together with molecular-level theoretical interpretation, can provide important information about the structure and dynamics of complex condensed phase systems, including liquids. The theoretical challenge is to calculate the instantaneous vibrational frequencies of a molecule in contact with a molecular environment, accurately and quickly, and to this end a number of different methods have been developed. In this paper we critically analyze these different methods by comparing their results to accurate benchmark calculations on azide/water clusters. We also propose an optimized quantum mechanics/molecular mechanics method, which for this problem is superior to the other methods.

Azides↗

Pronounced non-Condon effects in the ultrafast infrared spectroscopy of water.

In the context of vibrational spectroscopy in liquids, non-Condon effects refer to the dependence of the vibrational transition dipole moment of a particular molecule on the rotational and translational coordinates of all the molecules in the liquid. For strongly hydrogen-bonded systems, such as liquid water, non-Condon effects are large. That is, the bond dipole derivative of an OH stretch depends strongly on its hydrogen-bonding environment. Previous calculations of nonlinear vibrational spectroscopy in liquids have not included these non-Condon effects. We find that for water, inclusion of these effects is important for an accurate calculation of, for example, homodyned and heterodyned three-pulse echoes. Such echo experiments have been "inverted" to obtain the OH stretch frequency time-correlation function, but by necessity the Condon and other approximations are made in this inversion procedure. Our conclusion is that for water, primarily because of strong non-Condon effects, this inversion may not lead to the correct frequency time-correlation function. Nevertheless, one can still make comparison between theory and experiment by calculating the experimental echo observables themselves.

Computer Simulation↗

Personal networks enabling remote assistance for medical emergency teams.

Personal Networks provide the technology that is needed to interconnect the various private networks of a single user (home network, car network, office network, Personal Area Network, and others) seamlessly, at any time and at any place. This can be useful in many business sectors. In case of medical emergencies, it can provide a means to enlist remote assistance from peers wherever they are in the world at that particular moment. To illustrate this, we have analyzed the use case of a medical emergency surgery and have built a demonstrator.

Journal Article↗

Ultrafast vibrational spectroscopy of water and aqueous N-methylacetamide: Comparison of different electronic structure/molecular dynamics approaches.

Kwac and Cho [J. Chem. Phys. 119, 2247 (2003)] have recently developed a combined electronic structure/molecular dynamics approach to vibrational spectroscopy in liquids. The method involves fitting ab initio vibrational frequencies for a solute in a cluster of solvent molecules to a linear combination of the electrostatic potentials on the solute atoms due to the charges on the solvent molecules. These authors applied their method to the N-methylacetamide-D/D(2)O system. We (S. A. Corcelli, C. P. Lawrence, and J. L. Skinner, [J. Chem. Phys. 120, 8107 (2004)]) have recently explored a closely related method, where instead of the electrostatic potential, the solute vibrational frequencies are fit to the components of the electric fields on the solute atoms due to the solvent molecules. We applied our method to the HOD/D(2)O and HOD/H(2)O systems. In order to make a direct comparison of these two approaches, in this paper we apply their method to the water system, and our method to the N-methylacetamide system. For the water system we find that the electric field method is superior to the potential approach, as judged by comparison with experiments for the absorption line shape. For the N-methylacetamide system the two methods are comparable.

Journal Article↗

Congruence on medication between patients and physicians involved in patient course.

OBJECTIVE: To analyse congruence on medication throughout patient courses, including an acute admission to a medical department. DESIGN: A prospective, observational study. Data were collected from patient records in primary health care, hospital departments, from the Health Insurance database and through patient interviews. SETTING: Departments of internal medicine, general practice and patients' homes. MAIN OUTCOME MEASURES: Number, type and character of discrepancies between paired sources of information on patient medication at predefined time points throughout the complete patient course. Assessment of likelihood and severity of potential untoward effects of discrepancies. RESULTS: Data were obtained for 75 of 99 consecutive patients included. Patients stated use of four drugs (median, range 0-17) at admission, five (0-16) at discharge and four (0-15) 1 month after discharge. At admission, 11 patients used no drugs. A median of one (0-20) to three (0-16) discrepancies per patient were identified in seven paired source comparisons with no improvement along patient course. Full agreement throughout the course was found in six patients (8%; 95% confidence interval: 3-17%). No association was found among source discrepancies and number of drugs and age. Of discrepancies, 4-13% were considered serious and likely to cause untoward effects. Discrepancies due to synonymous and analogous drugs accounted for 2-7% of the discrepancies. CONCLUSION: Congruence between sources of information on medication throughout patient courses cannot be obtained with separate medication charts. Discrepancies among patient, general practitioner and hospital give rise to a definitive risk of serious untoward effects.

Adult↗

Predictions of county uninsured rates: accuracy and stability.

Uninsured rates of all counties in an area can be predicted by combining survey data from a subset of area counties and secondary data on economic indicators that are available for all counties. The authors present a set of indicators that are related to the uninsured rate and develop prediction models from surveys taken two years apart in the same counties. The accuracy and stability of the prediction models are assessed. Accuracy levels are highest when contemporaneous rates are predicted, but accuracy deteriorates when rates in a later time period are predicted using models from a prior period.

Adult↗

Analysis of p53 mutants for transcriptional activity.

The wild-type p53 protein functions to suppress transformation, but numerous mutant p53 proteins are transformation competent. To examine the role of p53 as a transcription factor, we made fusion proteins containing human or mouse p53 sequences fused to the DNA binding domain of a known transcription factor, GAL4. Human and mouse wild-type p53/GAL4 specifically transactivated expression of a chloramphenicol acetyltransferase reporter in HeLa, CHO, and NIH 3T3 cells. Several mutant p53 proteins, including a mouse p53 mutant which is temperature sensitive for suppression, were also analyzed. A p53/GAL4 fusion protein with this mutation was also transcriptionally active only at the permissive temperature. Another mutant p53/GAL4 fusion protein analyzed mimics the mutation inherited in Li-Fraumeni patients. This fusion protein was as active as wild-type p53/GAL4 in our assay. Two human p53 mutants that arose from alterations of the p53 gene in colorectal carcinomas were 30- to 40-fold less effective at activating transcription than wild-type p53/GAL4 fusion proteins. Thus, functional wild-type p53/GAL4 fusion proteins activate transcription, while several transformation competent mutants do so poorly or not at all. Only one mutant p53/GAL4 fusion protein remained transcriptionally active.

Animals↗

Comparative stress effects of vented and nonvented self-threading retentive pins.

Longitudinally vented self-threading pins do not demonstrate a significant improvement in the complete seating of the pins or a decrease of dentinal crazing. The link series technique does demonstrate a significant improvement in the complete seating of pins and in the prevention of misalignment of the pins with the channels.

Dental Pins↗

Post soldering a telescopic pontic.

A technique has been presented that involves the use of a telescopic ceramometal pontic soldered to a type III alloy substructure (Figs. 4 and 5). This technique eliminates the need for manufactured facings or the use of processed acrylic resin, but it incorporates the advantages of porcelain esthetics and wear with the increased ability to burnish the retainer margins.

Adult↗

A preliminary study of wear of porcelain when subjected to functional movements of retentive clasp arms.

Porcelain-metal crowns simulating abutment retainers for removable partial denture clasping were studied to determine the effects of wear to the porcelain surface and possibilities of fracture. Surface profile recordings at x 1,000 were made on the porcelain surfaces before and after subjecting samples to wear that was equivalent to 2 years of patient use. Little or no change was recorded in these surface profiles, indicating that little or no wear had occurred. None of the samples failed due to porcelain fracture. It appears that well-fabricated, glazed porcelain surfaces can withstand the wear forces of removable partial retentive clasp arms.

Dental Abutments↗