Search PubMed⌕ Search

Biomedical subjects

J R Rodarte

Publications and source records attributed to J R Rodarte.

At least 109 records · Page 6Linked to original sources

Elastic constants of trapped lung parenchyma.

Isolated dog lobes were maximally trapped with air, and their parenchymal elastic properties were measured at the trapped volume. Indentation tests were performed on the surface of the lobes, followed by uniaxial and torsion tests on excised pieces of parenchyma. Similar values for Young's modulus were obtained from the indentation and uniaxial tests. The values for the shear modulus from the torison tests also were consistent with Young's modulus measured by the other procedures. The indentation test provided an accurate estimate of Young's modulus or the shear modulus for trapped lobes, and the results suggest that it is a valid method for estimating these constants in nontrapped lobes.

Animals↗

Effect of parenchymal shear modulus and lung volume on bronchial pressure-diameter behavior.

A method that interrelates lung pressure-volume behavior, bronchial pressure-diameter behavior, and parenchymal shear modulus is presented. The method was used to predict changes in intraparenchymal bronchial diameter that occurred when lobe pressure-volume behavior and parenchymal shear modulus were markedly changed by inducing air trapping in isolated dog lobes. Predictions agreed with measurements, thereby supporting the general method. Measured values for the shear modulus were approximately 0.7 times the transpulmonary pressure for the control state. Estimated values for the peribronchial pressure difference from pleural pressure during a deflation pressure-volume maneuver for transpulmonary pressures below 12 cmH2O were small, approximately +/- 1 cmH2O, its sign being positive or negative, depending on whether the bronchus was dilated or contricted.

Animals↗

Regional lung expansion at total lung capacity in intact vs. excised canine lungs.

A computer-based biplane videoroentgenographic recording technique that determines the spatial coordinates of radiopaque lung parenchymal markers was used to compare regional lung expansion at total lung capacity (TLC) in the intact dog (prone and supine) and after removal from the chest. The reproducibility of the technique was examined by repeated determinations of intermarker distances at various static lung volumes during stepwise inflation and deflation of the lungs. Most of the variability in repeated determinations of intermarker distances at any lung volume was due to cardiogenic motion. When marker positions were determined repeatedly at the same phase of the cardiac cycle, the maximum coefficient of variation was less than 3% for a marker pair separated by 16.5 mm. At TLC, distances between all intralobar marker pairs in the intact thorax (prone and supine) and excised were highly linearly related (r = 0.96-0.99), whereas distances between interlobar marker pairs did not correlate as well (r = 0.77-0.86). We conclude that at TLC 1) the intact thorax does not distort the shape of the individual lobes from the state of isotropic expansion, and 2) in different body positions, overall lung shape may be different due to displacementof lobes relative to each other, but individual lobes remain uniformly expanded.

Animals↗

Airway closure.

Explore the source record for details and available documents.

Adolescent↗

Regional intrapulmonary gas distribution in awake and anesthetized-paralyzed man.

Intrapulmonary distribution of ventilation/unit lung volume was studied in 28 volunteers in the sitting, supine, or right lateral decubitus position, either awake or anesthetized-paralyzed and mechanically ventilated. We found significant differences between the awake state and anesthesia-paralysis with mechanical ventilation in 1) intrapulmonary gas distribution, and 2) the vertical gradient of regional functional residual capacities for the subjects in the lateral decubitus position, but not for those in the sitting and supine positions. The effect of increasing the tidal volume on distribution of ventilation was significantly different 1) between the three body positions for a given state, and 2) between the two states for a given body position. The data suggest thoracoabdominal mechanics are different in the three body positions and that anesthesia-paralysis and mechanical ventilation may cause a different pattern of expansion of the respiratory system than spontaneous breathing in the awake state.

Adult↗

Effect of breathing helium-oxygen on static lung volumes and lung recoil in normal man.

Static lung volumes and static elastic recoil pressure (Pel) were measured in normal subjects breathing air and 80% helium plus 20% oxygen (He+O2). In 22 subjects, He+O2 produced small but significant increases in total lung capacity (TLC) (mean 0.11 liter, P less than 0.001) and residual volume (mean 0.10 liter, P less than 0.01) without change in vital capacity or functional residual capacity. The mechanisms for this change are obscure. In 10 subjects, breathing He+O2 had no significant effect on Pel (paired t-test) at any lung volume measured (50-80% TLC). In one subject, Pel at 70 and 80% TLC was significantly higher on air than on He+O2 (unpaired t-test, P less than 0.05). Because changes in lung volumes and lung recoil were small, we concluded that these effects do not negate the clinical utility of He+O2 flow-volume curves.

Adult↗

Lung recoil and gas trapping during oxygen breathing at low lung volumes.

If airways are closed at lung volumes less than the closing volume (CV), there should be correlations among 1) the volume of trapped N2 (VTN) during N2-washout performed below CV, 2) the increase in static lung recoil pressure (delta P) while breathing below CV after denitrogenation compared with breathing air (due to absorption atelectasis distal to closed airways), and 3) the CV. Static inspiratory pressure-volume (PV) curves and CV were measured in 18 seated normal volunteers (ages 24-48 yr). Subjects then breathed air for 30 s and O2 for 2.5 min at RV + 0.6 liter (LVB-air), and an inspiratory PV curve and VTN were determined. While still breathing O2, the subjects repeated the 3 min of low-volume breathing (LVB-O2). There was a significant (P less than 0.001) delta P with LVB but no difference between delta P (LVB-air) and delta P (LVB-O2). CV was not related to VTN or to either delta P. VTN was not related to delta P (LVB-O2)--delta P (LVB-air) nor to delta P (LVB-air), but was related to delta P (LVB-O2). Evidence of airway closure could not be demonstrated in all subjects by LVB and when present showed no correlation with CV.

Adult↗

Behavior of artificially produced holes in lung parenchyma.

Spherical and cylindrical holes were cut in the parenchyma of isolated dog lung lobes. The holes were insufflated with tantalum dust and the hole diameters were measured along the deflation limb of the lobe pressure-volume curve from transpulmonary pressures of 20 to 0 cmH2O. Hole volume as a fraction of lobe volume was found to be independent of transpulmonary pressure. The hole volume relative to the amount of tissue removed was used to determine the displacement at the hole boundary. A comparison of this displacement with the displacement predicted by a continuum mechanics analysis provides evidence for the applicability of the methods of continuum mechanics and further evidence that the shear modulus of the parenchyma is relatively small.

Animals↗

New tests for the detection of obstructive pulmonary disease.

Abnormalities in small airways appear to be important in the evolution of chronic obstructive pulmonary disease. Patients with these pathologic lesions may have normal values for airway resistance and forced expiratory volume in one second. Two new tests, the closing volume (CV) and the dependence of maximal flow on density, are believed to be sensitive to abnormalities in the peripheral airways. The CV test detects an increased nonuniformity of changes in volume of pulmonary units. Reduced dependence of flow on density is believed to result from an increase in the peripheral component of the losses of driving pressure which determine maximal expiratory flow. Both tests differentiate smokers with normal conventional spirometric data from age-matched nonsmokers. Although this evidence suggests that these tests can be used to detect abnormalities in small airways, there is very little pathologic confirmation of this belief. The clinical significance of abnormalities in the results of either of these tests in an otherwise normal person has not yet been determined.

Airway Resistance↗

Single-breath oxygen tests for individual lungs in awake man.

Single-breath oxygen (SBO2) tests for individual lungs were performed in five healthy awake volunteers. In the supine position, all subjects consistently showed a closing volume (CV) for both lungs. In the lateral position, CV was demonstrated in all analyzable SBO2 tests for the dependent and in 20 of 28 for the nondependent lung. CV consistently occurred in the dependent before it occurred in the nondependent lung (asynchronous onset of CV). After CV had been reached in the nondependent lung, a mean of 77 ml of gas was still expired from the dependent lung. No changes in CV for individual lungs were demonstrated with changes in body position. Expiratory flow limitation consistently occurred first in the dependent lung (asynchronous onset of flow limitation). In the lateral position, at high lung volumes, the dependent lung achieved higher flow rates; later in expiration, the nondependent lung contributed progressively more gas to the total expirate (asynchronous emptying). In general, our findings are consistent with both the "asynchronous flow limitation" and the "airway closure" interpretations of CV. However, some of the results are not consistent with either theory.

Adult↗

Elastic constants of inflated lobes of dog lungs.

The elastic constants of dog lungs were determined at various degrees of inflation. In one set of experiments, the lobes were subjected to deformations that approximated the conditions of uniaxial loading. These data, together with the bulk modulus data obtained from the local slope of the pressure-volume curve, were used to determine the two elastic moduli that are needed to describe small nonuniform deformations about an initial state of uniform inflation. The bulk modulus was approximately 4 times the inflation pressure, and Young's modulus was approximately 1.5 times the inflation pressure. In a second set of experiments, lobes were subjected to indentation tests using cylindric punches 1-3 cm in diameter. The value for Young's modulus obtained from these data was slightly higher, approximately twice the inflation pressure. These experiments indicate that the lung is much more easily deformable in shear than in dilatation and that the Poisson ratio for the lung is high, approximately 0.43.

Animals↗

Esophageal elastance in awake and anesthetized recumbent dogs.

Esophageal elastance was measured in trained dogs placed in the prone, supine, and left lateral postures before and during sodium thiopental anesthesia. Esophageal elastance was measured from static pressure-volume curves and during spontaneous breathing at functional residual capacity. There was a significant decrease in esophageal elastance, estimated from the pressure-volume curves, during anesthesia in both prone and lateral positions but not in the supine posture. Changes in vagal tone produced by stimulation of the vagal nerves did not alter esophageal elastance. Therefore, underlying mechanisms for these changes in esophageal elastance are not fully understood. There was an increase in esophageal elastance when lung volumes increased from 55 to 80% total lung capacity. However, we did not find a significant change in esophageal elastance between awake and anesthetized conditions or between positions during spontaneous breathing at functional residual capacity.

Anesthesia↗

Effect of posture on the single-breath oxygen test in normal subjects.

The effect of posture on phase III (alveolar nitrogen plateau) and phase IV (closing capacity) of the single-breath oxygen test was examined in 10 normal people. In part 1 of the study, subjects inspired and expired in the standing, supine, prone, and right lateral decubitus positions; there was no effect of posture on phase IV but slopes of phase III were higher when subjects were in the supine and lateral positions. In part 2, subjects inspired in the standing position and expired in one of the recumbent positions. Phase IV occurred infrequently except in the prone position (6 of 10 subj); slopes of phase III in part 2 were not consistently altered by changing posture. It is difficult to explain the failure of posture to alter phase IV solely on a model requiring a linear gradient of pleural pressure. The slope of phase III appears to depend more on the emptying patterns of small regions with widely varying volume-to-ventilation ratios than on gravity-dependent sequences of emptying. Finally, the data suggest a considerable similarity between the upright and prone positions in terms of lung filling and emptying.

Adult↗

Determination of lung volume by single- and multiple-breath nitrogen washout.

In 10 normal volunteers, total lung capacity determined from a single-breath N2 washout was not significantly different from that determined by body plethysmography. However, in patients who underwent clinical pulmonary function tests, total lung capacity was substantially underestimated by the single-breath N2 washout, compared with that determined by either body plethysmography or the 7-min open-circuit N2 washout method. The single-breath N2 washout underestimated total lung capcity in patients who had a normal slope of Phase III, and the error was even greater in patients who had steeper Phase III slopes or low maximal mid-expiratory flow values. Total lung capacity determined by 5 vital capacity breath N2 washout method was comparable to that determined by the 7-min N2 washout method, provided that expired N2 did not exceed 10 per cent during the fifth vital capcity maneuver. By extending the washout beyond 5 vital capacity maneuvers when necessary to achieve a peak expired N2 of less than 10 per cent, a mean total lung capacity within 1 per cent of that determined by the 7-min washout method was obtained. The multiple vital capacity maneuver was well tolerated by patients and saved considerable time.

Humans↗

Lung volumes and closing capacity with continuous positive airway pressure.

Total lung capacity, vital capacity, residual volume, and functional residual capacity were determined by body plethysmography and the single-breath oxygen (SBO2) test was performed at 0, 5, and 11 cm H20 continuous positive airway pressure in healthy, awake, seated, spontaneously breathing subjects. Mean values for the absolute lung volume at which phase IV of the SBO2 test begins (closing capacity) did not change significantly with continous positive airway pressure at 5 or 11 cm H2O. Mean total lung capacity, functional residual capacity, and residual volume increased significantly, and the mean closing volume, the lung volume above residual volume at which phase IV begins, decreased significantly with 11 cm H20 continuous positive airway pressure; differences at 5 cm H20 were not significant. The slope of the alveolar nitrogen plateau (phase III) obtained during the SBO-2 test did not change with continuous positive airway pressure.

Adult↗

Positive airway pressure and vertical transpulmonary pressure gradient in man.

Static transpulmonary pressure (Pao-Pes) and the vertical gradient of transpulmonary pressure were determined in five sitting conscious normal subjects at mean airway pressures of 0 (ambient), 11, and 21 cmH2O. All subjects exhibited a nonuniform transpulmonary pressure gradient down the esophagus. The vertical pressure gradient was consistently larger in the lower (8-20cm below esophageal artifact) than in the middle region (0-8cm) of the esophagus. The gradient was not significantly altered by continuous positive airway pressure (11 and 21 cmH2O) or by changes in lung volume (60, 70, and 80% of total lung capacity (TLC)). Continuous positive airway pressure also did not result in a consistent change of the overall static pressure-volume curve of the lung. There was a small but statistically significant increase in TLC with each increase in airway pressure.

Biomechanical Phenomena↗