Search PubMed⌕ Search

Biomedical subjects

J R Petersen

Publications and source records attributed to J R Petersen.

At least 19 recordsLinked to original sources

Accuracy and precision of point-of-care testing for glucose and prothrombin time at the critical care units.

The use of point-of-care testing (POCT) in critical care patient units has continued to increase since the 1980s. This increase is due to the need for prompt therapeutic interventions that may impact mortality and morbidity, and reduce the overall cost of healthcare for critically ill patients. The diagnostic manufacturing industry has risen to this challenge by introducing portable and/or handheld analyzers for use at the point-of-care. In order to ensure the public safety in the USA, the Food and Drug Administration (FDA) must approve the use of each POCT analyzer. The FDA approval is based on established performance criteria that includes relative accuracy and precision documentation. This study evaluated the precision and accuracy of the POCT prothrombin time and glucose analyzers relative to the manufacturers' specifications, to the internal QC in the main laboratory, and to the results of the external proficiency-testing program. The QC for the prothrombin time had a precision that ranged from 2.84% to 3.45% (POCT) and from 1.27-1.66% (main laboratory). The precision for the glucose QC ranged from 5% to 5.2% (POCT) and 0.9-2.7% (main laboratory). Using the results of the external proficiency testing, the inter-laboratory CV% for the POCT prothrombin time ranged from 3.5% to 5.0% and the main laboratory had a range of 2.5-2.9%. The inter-laboratory CV% ranges for glucose POCT and the main laboratory were 4.9-10.6% and 1.8-3.5%, respectively. The main laboratory analyzers proved to be more accurate than the POCT analyzers as indicated by comparison to the mean prothrombin time and glucose results of all participating laboratories in the proficiency testing program.

Blood Glucose↗

Composite nodular lymphocyte-predominance Hodgkin disease and gamma-heavy-chain disease: a case report and review of the literature.

The association of Hodgkin disease with monoclonal gammopathy has rarely been reported. We present a case of a 48-year-old woman with a history of autoimmune hemolytic anemia and Graves disease who presented with hepatosplenomegaly and a gamma-heavy-chain paraprotein. Histopathology of lymph node and bone marrow revealed nodular lymphocyte-predominance Hodgkin disease, while examination of the spleen revealed plasmacytosis consistent with gamma-heavy-chain disease. Following splenectomy, the patient has remained in complete remission for both conditions with no further treatment. To our knowledge, this is the first report of a patient with both gamma-heavy-chain disease and nodular lymphocyte-predominance Hodgkin disease. Given recent data indicating the B-cell nature of this form of Hodgkin disease, the authors propose that in this unique case there may be a clonal relationship between these 2 concurrent B-cell lymphoproliferative processes.

B-Lymphocytes↗

A randomized and double-blind comparison of isradipine and spirapril as monotherapy and in combination on the decline in renal function in patients with chronic renal failure and hypertension.

AIMS: Treatment of hypertension in patients with chronic renal failure has been shown to postpone the decline in renal function. Treatment with an ACE inhibitor has been shown to be superior to conventional antihypertensive treatment, but it is not known how an ACE inhibitor compares to treatment with a calcium channel blocker or to treatment with a combination of these drugs. The aim of the study was to evaluate the rate of decline in GFR in patients with chronic renal failure and hypertension treated with isradipine and spirapril as monotherapy and in combination. METHODS: Sixty patients with chronic renal failure and hypertension were enrolled in the study. After enrollment, patients were followed prospectively for 6 months in the outpatient clinic on their usual antihypertensive medication, and then randomized to a double-blinded comparison of either spirapril 6 mg daily, isradipine 5 mg daily or spirapril 3 mg and isradipine 2.5 mg daily. After randomization, patients were followed for 21 months or until the need for dialysis. Every 3 months before and 3.5 months after randomization the glomerular filtration rate was measured by 51Cr-EDTA clearance and the effective renal plasma flow evaluated using the renal clearance of paraaminohippuric acid. RESULTS: Blood pressure and the decline in glomerular filtration rate did not differ between the groups before randomization. After randomization, the mean decline in the glomerular filtration rate was -0.32 ml/(min x month x 1.73 m2) in the spirapril group, -0.58 ml/(min x month x 1.73 m2) in the isradipine group and -0.14 ml/(min x month x 1.73 m2) in the combination group (p = 0.38). Twelve patients, 4 in each group, reached end-stage renal failure. No significant difference was found with respect to diastolic (p = 0.10) or systolic blood pressure (p = 0.08) during the treatment period, but a trend towards a better blood pressure control in the combination group was present. During treatment, the rate of decline in renal plasma flow did not differ significantly between the groups (p = 0.09), neither did the changes in filtration fraction (FF) (p = 0.58) nor the mean FF (p = 0.22) during the treatment. CONCLUSIONS: Our study indicated differences between the 3 treatment modalities in favor of combined therapy with respect to both the rate of decline in GFR and blood pressure control, but the differences where insignificant. Thus, the treatments might differ, but we were unable to confirm this because of large variation in GFR and small sample size.

Adolescent↗

Apparatus and method for interfacing capillary electrophoresis and chemiluminescence nitrogen detection for the analysis of nitrogen-containing compounds.

We have developed an interface that allows the specific detection of nitrogen-containing compounds by using a chemiluminescence nitrogen detector. The feasibility of using this interface was demonstrated by separating and detecting two nitrogen-containing compounds, p-aminosalicylic acid and L-phenylalanine. Although baseline separation was achieved, the theoretical plates were lower when compared to UV detection (25000 vs. approximately 85000). A sensitivity of 75 ng (approximately 500 pmol) per injection was achieved with this system which is adequate for pharmaceutical and biotech applications.

Aminosalicylic Acid↗

The possible association of decreased total cholesterol and severity of disease in elderly hospitalized patients.

The object of our study was to determine if any association exists between low serum cholesterol (< 4.14 mmol/l) and adverse outcomes in elderly patients > 60 years. Patients with low serum cholesterol were compared to a patient population with high serum cholesterol (> 6.22 mmol/l) and normal cholesterol (> or = 4.14 to < or = 6.22 mmol/l). Only hospitalized patients > 60 years, who were not on cholesterol lowering drugs, and did not have cardiovascular or liver disease were included in this study. The study group was 157 patients (79 with low, 78 with high, and 23 with normal cholesterol concentrations). Using the Kruskal-Wallis tests, the low cholesterol group was found to have statistically (p < 0.05) longer length of stay (average difference of > 11.1 days), higher hospital re-admission rate over a 1-year period (average difference of > 0.4 re-admissions), greater use of acute care services (average difference of > 0.6 days), and more emergency room (ER) visits over 1 year (average difference of > 0.5 admissions).

Age Factors↗

Stability of prothrombin time and activated partial thromboplastin time tests under different storage conditions.

Prothrombin time (PT) and activated partial thromboplastin time (aPTT) are common laboratory tests that are useful in the diagnosis of coagulation disorders and monitoring anticoagulant therapy. Recent expansions in the outreach laboratory services at our institution prompted us to investigate the shipping limitations for some tests, including PT and aPTT. Although we followed NCCLS guidelines for the collection of blood specimens, we observed falsely elevated PT and aPTT values due to the different storage conditions. The objective of this study is to determine the effect of conditions and duration of storage on PT and aPTT tests using plasma and whole blood samples, respectively. For this study, 36 plasma samples with normal and prolonged PT and aPTT were exposed to different storage conditions. Blood was centrifuged immediately and plasma was stored at room temperature (RT), refrigerated at 4 degrees C, or frozen at -20 degrees C. The samples were analyzed at 0 h and repeated at 6, 12 and 24 h under various conditions. Although statistically significant differences were observed for plasma samples for normal PT tests after 12 h at refrigerated and frozen storage conditions, the differences would not change the clinical interpretation of the results. On the other hand, samples stored refrigerated or at RT showed significant differences for aPTT at 24 h. These differences would change clinical interpretation, especially for samples with normal or near normal aPTT times. Interestingly, aPTT was significantly higher for samples stored frozen when compared to refrigerated and RT conditions at 6 h. Similar patterns were also observed on ten whole blood samples with normal PT and aPTT values. In conclusion, either plasma or whole blood samples can be accepted for PT testing up to 24 h and for aPTT testing up to 12 h only, when transported either at RT or at 4 degrees C.

Humans↗

Prospective study of IgM to Toxoplasma gondii on Beckman Coulter's Access(TM) immunoassay system and comparison with Zeus ELISA and gull IFA assays.

We compared a new assay for Toxoplasma IgM on the Access analyzer (Beckman Coulter, Inc., Chaska, MN, USA), a random access instrument based on the principle of paramagnetic particle enzyme immunoassay with an enzyme-linked immunosorbent assay (ELISA) (Zeus Scientific, Inc., Raritan, NJ, USA) and an immunofluorescent assay (IFA) (Gull Laboratories, Inc., Salt Lake City, UT, USA). Four hundred fresh, unfrozen clinical samples from pregnant women (n = 154), HIV positive patients (n = 41), and patients in whom infection with Toxoplasma gondii was suspected (n = 200) were collected and assayed over a three month period. The specificity of the Access assay was compared to the consensus results. Results that were discrepant between the ELISA and IFA were resolved using a third IFA (Zeus). Once resolved, the specificity for the Access assay, the Zeus ELISA and the Gull IFA were 99.22%, 97.91%, and 99.45%, respectively. We conclude that the Access assay specificity is comparable to consensus results, minimizing false positive results; and because it is a random access instrument, it may be preferable over batch methods.

Adolescent↗

Low-power laser irradiation increases cyclic GMP synthesis in penile smooth muscle cells in vitro.

OBJECTIVE: The objective of the present study was to determine the effect of low-power laser irradiation (LPLI) on cyclic guanosine monophosphate (cGMP) produced by human corpus cavernosum smooth muscle cells (HCC SMC) in vitro. BACKGROUND DATA: Numerous reports suggest that LPLI is capable of affecting cellular processes in the absence of significant thermal effect METHODS: HCC SMC cultures were irradiated with single-dose LPLI using a He-Ne continuous wave laser (632 nm) with different energy densities (0.52-2.1 J/cm2). Assessment of effect on cell viability was performed utilizing Alamar Blue assay. Effect of LPLI on cGMP production was studied by radioimmunoassay. RESULTS: We observed that: (1) LPLI of HCC SMC results in a statistically significant increase of cGMP synthesis in culture and is dose dependent (maximal effect was observed with LPLI irradiance of 1.57 J/cm2. (2) There were no changes in Normalized Viability Index (NVI) immediately after and 24 h following laser irradiation. CONCLUSION: Our studies demonstrate that LPLI irradiation stimulates elevation of cGMP in vitro.

Adult↗

Multiple site analytical evaluation of a portable blood gas/electrolyte analyzer for point of care testing.

OBJECTIVE: To evaluate the analytical performance of the SenDx 100 portable blood gas and electrolyte analyzer (SenDx Medical, Carlsbad, CA). DESIGN: Accuracy was evaluated by correlation of whole blood patient samples with the Nova Stat Profile 5 (Nova Biomedical, Waltham, MA) and the Ciba Corning 865 (Chiron Diagnostics, Medford, MA). Precision was evaluated using quality control materials (RNA Medical, Acton, MA). SETTING: Critical care laboratories and operating rooms in two institutions. MEASUREMENTS AND MAIN RESULTS: Precision studies performed at three different concentration levels for each analyte demonstrated intra-assay precision of < or =2.5% coefficient of variation and interassay precision of < or =4.0% coefficient of variation in all cases. Analysis of patient specimens in general showed good to excellent correlation to reference analyzers. Regression variables are tabulated. CONCLUSIONS: The SenDx 100 portable blood gas and electrolyte analyzer is a simple and easy to use analyzer demonstrating acceptable performance compared with reference methods.

Blood Gas Analysis↗

Photoactivation of vascular iNOS and elevation of cGMP in vivo: possible mechanism for photovasorelaxation and inhibition of restenosis in an atherosclerotic rabbit models.

Recently, intravascular low-power red laser light (LPRLL) therapy has been proposed for the prevention of postangioplasty restenosis due to the observed inhibition of experimental neointimal formation. The objective of this study was to determine the impact of endoluminal LPRLL on vascular levels of inducible nitric oxide synthase (iNOS) and cyclic guanosine monophosphate (cGMP) to help define the mechanism of this effect. Eight atherosclerotic male adult New Zealand White rabbits weighing 4-6 kg were used in these studies. The iliac arteries were treated in separate zones with: (1) balloon inflation only; (2) laser illumination only; and (3) balloon inflation + laser illumination. An uninjured zone of the iliac artery served as a control. Laser irradiation (630 nm) was delivered to the vessel wall via a Cold laser Illuminator (Cook, Inc., Bloomington, IN), with a 3 mm-diameter balloon. Experiments demonstrated that vascular cGMP levels obtained immediately following treatment in the balloon only group was the lowest (0.29 +/- 0.05 pmol/mg protein) and significantly lower compared with the uninjured controls (1.01 +/- 0.07 pmol/ mg protein) (P < 0.001). In the laser only treated group cGMP levels were significantly increased (2.87 +/- 0.12 pmol/mg protein) compared with the uninjured control (P < 0.001) and the balloon only group (P < 0.001). Vascular cGMP levels in the balloon + laser group (2.09 +/0.07 pmol/mg protein) was also increased compared to the balloon only (P < 0.001) and control (P < 0.001) groups. Qualitative analysis of Western blot demonstrated that laser illumination induces iNOS. In contrast balloon dilatation did not induce iNOS. Balloon + laser treatment, however, tended to restore the expression of iNOS. Our study demonstrated that intravascular low dose laser irradiation induces iNOS and elevates vascular cGMP in an in vivo atherosclerotic rabbit model.

Angioplasty, Balloon↗

Development of a urinary free cortisol assay using solid-phase extraction-capillary electrophoresis.

In clinical practice, the measurement of urinary free cortisol (UFC) provides the most sensitive and specific diagnostic information for excess adrenal production of cortisol. The existing methodologies (RIA and HPLC) are time consuming, costly, involve tedious extractions, derivatizations and problems with non-specific interactions with cortisol metabolites in urine. In the present study, we describe the development of an SPE-CE method for the rapid analysis of UFC. UFC was concentrated using SPE C18 cartridges (3M Empore) under a vacuum and eluted with acetonitrile-SDS. The use of 10% acetone to wash cartridges before final elution with acetonitrile-SDS showed significant improvements in the free cortisol recovery. The complete extraction was accomplished in 10-15 min with a recovery of 89-94%. CE analysis was done on a Beckman P/ACE 5010 with detection at 254 nm using a neutral capillary. Detection limits of free cortisol in urine was improved to 10 microg/l with SPE compared to 500 microg/l without SPE. No interferences either from BSA or other urinary cortisol metabolites affected the free cortisol determinations. The results showed the feasibility of a rapid UFC detection with improved sample handling capacity.

Electrophoresis, Capillary↗

The effect of thoracentesis on lung function and transthoracic electrical bioimpedance.

This study aimed to determine the relationship between improvement in lung function and changes in transthoracic electrical bioimpedance (TEB) after thoracentesis in patients with pleural effusions. Fifteen patients with pleural effusions due to either malignant (n = 8) or cardiac (n = 7) diseases were included. Pulmonary function was assessed before and after thoracentesis. During thoracentesis the patients were monitored with TEB. Using linear correlation analysis, the increases for each litre of aspirated thoracic fluid were: forced expiratory volume in 1 s (FEV1) 0.261; forced vital capacity (FVC) 0.331; total lung capacity (TLC) 0.58; and the lung diffusing capacity (DLCO); 2.4 ml min-1 mmHg-1. Baseline impedance increased by 2.3 Ohm l-1 aspirated thoracic fluid. The relative increase in baseline impedance was twice as high for patients with cancer as for patients with heart failure (P < 0.05). We found only minor changes in systolic blood pressure and mean arterial pressure. The improvements in diffusing capacity, airflow, and lung volumes after thoracentesis are correlated to an increase in baseline impedance, but changes are dependent on the primary disease.

Aged↗

Prevalence of cardiovascular risk factors in the Republic of Georgia.

BACKGROUND: Eastern Europe is experiencing an epidemic of deaths from cardiovascular diseases with an increase since the early 1990s approaching 50%. The ability to survey the risk factors associated with this striking rise is severely hampered by the current disarray of the area's public health system. We used a rapid survey method to describe the epidemiology of cardiovascular risk in the capital of the Republic of Georgia, Tbilisi. METHODS: A two-stage cluster design, 'rapid survey method' developed by the Chronic Disease Center was used to estimate the frequency of hypertension, a major cardiovascular risk factor. Local personnel were trained and certified in blood pressure measurement and rapid survey techniques. The training and survey were conducted over a period of 14 days at which time a preliminary report of the survey was presented to the Ministry of Health. RESULTS: A total of 321 subjects were surveyed. The frequency of high blood pressure (>140/>90 mm Hg) at the time of the examination was 58% in men and 56% in women. The major correlates for blood pressure were gender and age. In addition we found that 31% of the population had a total cholesterol > or =220 mg% and a similar number had a low high density lipoprotein < or =35 mg%. Smoking was present in 60% of men and none were taking aspirin daily to prevent premature coronary artery disease. CONCLUSIONS: The rapid survey method is feasible in the former Soviet Union and can quickly provide estimates of the risk factors associated with the epidemic of cardiovascular disease in this area.

Adult↗

Glomerular filtration rate estimated from the uptake phase of 99mTc-DTPA renography in chronic renal failure.

BACKGROUND: The purpose of the study was to compare the estimation of glomerular filtration rate (GFR) from 99mTc-DTPA renography with that estimated from the renal clearance of 51Cr-EDTA, creatinine and urea. METHODS: Fifty patients with reduced renal function (serum creatinine between 150 and 600 micromol/l) were enrolled in the study. GFR was estimated from the uptake phase of 99mTc-DTPA renography (GFR(DTPA)). The renal clearance of 51Cr-EDTA (GFR(EDTA)) was used as the reference method. Creatinine clearance (C(Cr)), urea clearance (C(Ur)) and the mean of urea and creatinine clearance (C(Cr+Ur)/2) were also calculated from urine collected during a period of 24 h. Limits of agreement were used for method comparison. RESULTS: The limit of agreement between GFR(DTPA) and GFR(EDTA) was 2 +/- 17 ml/min. The mean difference did not deviate significantly from zero. The other clearance techniques had larger limits of agreement and a mean difference significantly different from zero. Furthermore, C(Ur) and C(Cr+Ur)/2 had systematic deviations of the differences, indicating that C(Ur) and C(Cr+Ur)/2 are poor estimates of GFR. CONCLUSION: The limit of agreement between GFR(DTPA) and GFR(EDTA) are acceptable and, therefore, GFR estimated from 99mTc-DTPA renography is acceptable for clinical use in patients with reduced renal function. Furthermore, the method is simple and less time consuming compared with renal clearance techniques.

Adult↗

The calcipotriol dose-irritation relationship: 48 hour occlusive testing in healthy volunteers using Finn Chambers.

Calcipotriol is widely used in the treatment of psoriasis. Adverse lesional and perilesional irritation may occur. Allergy may occasionally be suspected. Allergy patch testing with calcipotriol may be difficult or impossible because calcipotriol is a local irritant. The aim of the present study was to assess the calcipotriol dose-irritation relationship, and establish a non-irritant patch test concentration for calcipotriol allergy patch testing. The study was a prospective, double-blind, randomized, dose titration evaluation in 180 healthy volunteers never previously exposed to calcipotriol. All individuals were patch tested with a calcipotriol dilution series (range 0.016-250 micrograms/mL). Clinical reading of test sites and measurement of erythema using a Minolta ChromaMeter were performed on days 2 and 3. Laser Doppler perfusion imaging of cutaneous blood flow was performed on day 3. Doubtful reactions (score 1/2) and weak reactions (score 1) were frequent and observed even at low dose exposure. Reactions declined in strength between the readings on day 2 and day 3. Only score 2 reactions with moderate erythema and some infiltration showed a threshold of no irritation. This threshold was confirmed by colorimetry and flowmetry. Cases of suspected allergy to calcipotriol may to avoid irritant reaction and false positive readings, be patch tested with calcipotriol 2 micrograms/mL citrate-buffered isopropanol solution applied under occlusion for 48 h using small Finn Chambers. Score 1/2 and 1 reactions are likely to reflect irritation. A positive test should be repeated after a minimum period of 3 months to ensure its consistency over time. A repeated open application test may be indicated.

Adolescent↗

[Thyroid stimulating antibodies in pregnant women with Graves' disease and neonatal thyrotoxicosis].

Thyroid stimulating antibodies (TSAb) are thought to be involved in the initiation of Graves' disease, and thyrotoxicosis in the neonatal period is often caused by TSAb passing the placental barrier. We wanted to evaluate measurement of TSAb levels as a possible predictor of neonatal thyrotoxicosis in pregnant patients with Graves' disease. We retrospectively evaluated 18 consecutive pregnant patients with Graves' disease. In 16 patients TSAb were measured in early pregnancy, six had increased values. In 14 of 18 patients normal values were found in late pregnancy and none of the children developed neonatal thyrotoxicosis. Two patients had greatly elevated TSAb values, and their children had neonatal thyrotoxicosis. Two patients had slightly elevated TSAb levels and delivered normal children. We conclude that all pregnant patients with an actual or a history of Graves' disease, should have measured TSAb. High TSAb values in late pregnancy indicate a considerable risk of neonatal thyrotoxicosis.

Adult↗

The pulsatility index and the resistive index in renal arteries. Associations with long-term progression in chronic renal failure.

BACKGROUND: The pulsatility index (PI) and the resistive index (RI) are used as pulsed-wave Doppler measurements of downstream renal artery resistance. PI and RI have been found to correlate with renal vascular resistance, filtration fraction and effective renal plasma flow in chronic renal failure. The aim of the present study was to evaluate the potential relationship between these indices and the rate of decline in renal function, as reflected by changes in different parameters of renal function in patients with chronic renal failure. METHODS: Twenty-one patients (8 females; 13 males, mean age 58 years (36-75)) with chronic renal failure were enrolled in the study. Doppler examinations were performed in the segmental arteries by an Acuson 128XP. The PI and the RI was calculated from the blood flow velocities. Parameters of renal function were measured every 3 1/2 months, and all patients were followed for 18-21 months. Progression of renal dysfunction was estimated by linear regression of parameters of renal function versus time. RESULTS: In a multiple regression analysis both PI and RI correlated significantly to the rate of decline in reciprocal serum creatinine (PI: r = -0.48, P = 0.03; RI: r = -0.52, P = 0.02). Furthermore, when separating the patients in two groups by the median RI value, there was a significant difference between the groups in rate of decline in reciprocal serum creatinine (P = 0.02). For PI this distinction was also present (P = 0.04). CONCLUSION: PI and RI correlated to the severity of the renal disease, as reflected by the rate of decline in reciprocal serum creatinine during antihypertensive treatment. The median RI or PI value could separate the patients into groups one of slow and another of fast progression.

Adult↗