Effect of demineralized bone matrix on bone growth within a porous HA material: a histologic and histometric study.

Coralline hydroxyapatite (cHA) is an osteoconductive material currently being used as a bone graft substitute. Created by the hydrothermal conversion of the calcium carbonate skeleton of coral to hydroxyapatite, this material has a porous structure similar to cancellous bone. Addition of demineralized bone matrix (DBM) would conceivably create a composite with both osteoconductive and osteoinductive properties. This pilot study evaluated the healing of rabbit cranial defects that had been filled with cHA or cHA augmented with a DBM gel formed by adding glycerol to the DBM particulate. Data from these were then compared to unfilled defects from a previous study. Results indicated enhancement of new bone formation and an increase in the rate of healing in the defects filled with the cHA-DBM gel composite. Further studies are warranted.

Animals↗

The porous-coated anatomic (PCA) total hip arthroplasty: a review of 73 uncemented cases with 2-year follow up.

A total of 73 hips in 62 patients who underwent non-cemented total hip arthroplasties (THA) with porous-coated anatomic (PCA, Howmedica) prostheses have been reviewed. A complete evaluation including preoperative and postoperative Harris hip scores (HHSs), a complete radiographic study, and complication determination has been completed with greater than 2-year follow up. Diagnoses included osteoarthritis (74.0%), rheumatoid arthritis (4.1%), avascular necrosis (15.1%), and posttraumatic arthritis following fracture (6.8%). The complication rate was 10.9% (8 complications/73 arthroplasties); 20 patients (35.6%) received bilateral implants. The mean preoperative HHS for the entire group was 38.7, and the mean postoperative score, irrespective of postoperative time, was 93.6. Key findings regarding the consecutive radiographic review of each arthroplasty included: 9.6% lucencies, 43.8% stress shielding, stable fibrous ingrowth in 74.0%, tip sclerosis in 19.2%, and cortical widening in 4.1%. The finding of loose beads from the pore ingrowth area of the prosthesis was minimal (7 beads in 6 patients). These results demonstrate the efficacy of the PCA prosthesis.

Activities of Daily Living↗

Materials and design concepts for an intervertebral disc spacer. I. fiber-reinforced composite design.

The intervertebral disc is a complex joint anatomically and functionally. It may be displaced or damaged due to trauma or a disease process. To alleviate this condition, it may be necessary to remove the involved disc surgically and fuse the two adjacent vertebrae. Fusion is one option; however, replacing the damaged disc (or part thereof) with a suitable synthetic equivalent to allow near normal joint motion is more desirable. Unfortunately, the complex mechanical properties of the lumbar disc cannot be duplicated with homogeneous synthetic materials (polymers). To overcome this fundamental problem we have developed rational designs utilizing biocompatible thermoplastic elastomers of various stiffnesses (durometers) with and without fiber reinforcements. Our design consisted of three components analogous to the natural end plates, annulus, and nucleus. In this study only the fiber-reinforced design is considered. The variables examined in the present study included orientation of the fiber layers, number of fiber layers, and order of the reinforcing layers. The results of mechanical testing of the fiber reinforced disc spacer indicate that the range of compressive and torsional properties can be achieved. The results further demonstrate that properly developed, this design results in properties similar to the natural disc. Designs developed provided adequate compression and compression torsion properties for a synthetic spine disc spacer.

Biocompatible Materials↗

Investigation of an organic delivery system for demineralized bone matrix in a delayed-healing cranial defect model.

The osteogenic potential of demineralized bone matrix (DBM) has been demonstrated in multiple animal models and clinical applications. A particulate form of DBM is generally used to fill defects because it is easily packed into a defect site without operative planning or shaping. One potential disadvantage in the use of a particulate is the migration of particles from the defect site. To stem this, glycerol was added to DBM to improve handling properties. A study was undertaken to compare two forms of DBM with glycerol, with DBM particulate and autograft in a bony defect site. The model chosen consisted of bilateral 8-mm trephine defects created in the parietal skull of 40 rabbits. Animals were sacrificed at 2 and 8 weeks. Results demonstrated both cartilage and bone induction with the three forms of DBM, with 75-90% of the linear width of the defect filled with new bone by 2 weeks. This was similar to the autograft (86%) and significantly greater than the unfilled defects (26%) at 2 weeks. The addition of glycerol to the DBM did not affect the inductive capacity, and produced a response similar to that of DBM particulate alone or autogenous bone.

Animals↗

Mechanical evaluation of a canine intervertebral disc spacer: in situ and in vivo studies.

An elastomeric intervertebral disc spacer with hydroxyapatite ingrowth surfaces was implanted in a canine model. We studied (a) the mechanical behavior of motion segments at time 0 and at 3, 6, and 12 months and (b) the effect of the interface between the spacer and vertebral bone on implant stability and bone ingrowth. A polymeric spacer was designed with compressive and torsional properties similar to those of the isolated canine lumbar disc. Implantation of the spacer in canine cadaver motion segments permitted in situ biomechanical evaluation at time 0. An in vivo study permitted continuous neurological monitoring of animals, with evaluation of mechanical behavior, stability, and ingrowth at 3, 6, and 12 months. Mechanical testing of cadaver motion segments with the spacer in situ resulted in decreased compressive and torsional stiffnesses, averaging 25 and 42%, respectively. This decrease was due to a combination of the surgical insult to the annulus and decortication of adjacent vertebral endplates. In the in vivo study, all 12 animals tolerated the surgery well and none had permanent neurological impairment. The measured parameters indicated that behavior of the spacer-motion segment composite appeared to return to normal within 3-6 months. However, despite use of a porous hydroxyapatite on the implant surface, there was no significant bone ingrowth. Instead, a layer of dense fibrous connective tissue was formed at the spacer-vertebral bone interface. Early migration of five of the 12 spacers resulted in eccentric loading patterns with consistent reactive osteophyte formation.

Animals↗

Mechanics of interbody spinal fusion. Analysis of critical bone graft area.

Bone graft subsidence is a serious complication of interbody spinal fusion. In this study, 66 mechanical tests were performed on 35 thoracic vertebral bodies to investigate the in situ mechanics of interbody spinal fusion. The relationships among trabecular bone density, bone strength, and size of bone graft area were analyzed. All vertebral bodies were scanned by quantitative computer tomography (QCT) to determine their bone density before mechanical testing. The decorticated trabecular beds of the vertebral bodies, void of all posterior elements, were loaded in a manner similar to that which occurs after surgical interbody fusion. That is, rectangular blocks of polymethylmethacrylate, representing bone grafts, were used to transfer controlled compressive loads to the decorticated vertebral trabecular surface. Both destructive and nondestructive tests were performed. The relationship between QCT bone density and trabecular bone strength was related by a power function, and, on average, the bone density and trabecular bone strength were 0.137 g/cm3 and 3.97 MPa, respectively. Eighty percent of the vertebral bodies with graft covering 25% of the total end plate area or less failed at loads less than 600 N, while 88% of the vertebral bodies with 30% or greater covered were able to carry a load greater than 600 N. The results suggest that the intrinsic behavior of trabecular bone loaded within the vertebral body is little different from the behavior of the whole body, that QCT bone density is indicative of bone strength, and that interbody graft area should be significantly greater than 30% of the total end plate area to provide a margin of safety.(ABSTRACT TRUNCATED AT 250 WORDS)

Biomechanical Phenomena↗

The mechanical properties of the canine lumbar disc and motion segment.

A study was initiated to measure the mechanical properties of the canine lumbar spine disc and motion segment at two specific levels. Compressive stiffness was determined to be 717.8 N/mm at L2-3 and 949.0 N/mm at L5-6. Torsional stiffness was found to be 1.04 Nm/deg at L2-3 and 1.72 Nm/deg at L5-6. These data were then compared to human lumbar spine disc and motion segment properties that have been reported in the literature. After normalizing for size differences, the canine lumbar disc showed a similar axial modulus (14.03 MPa for L2-3 and 16.30 MPa for L5-6) and a significantly higher torsional modulus (30.80 MPa for L2-3 and 26.17 MPa for L5-6) when compared to human values. The relative contributions of ligaments, posterior elements, and intervertebral disc to overall stability of the motion segment was found to be similar in canines and humans. As has been shown in human spine research, the posterior elements including the facet joints were found to be significant structures in providing torsional rigidity of the canine spine.

Animals↗

Shear stability of an elastomeric disk spacer within an intervertebral joint: a parametric study.

A parametric study was conducted to compare the resistance to shear force provided by three surgical implantation techniques and three endplate designs for use with a polymeric lumbar intervertebral disk spacer. While under an axial load, the implant was pushed out laterally through the surgical window created for implantation. Force at 0.3 mm displacement, slope of the initial portion of the force-displacement graph, and maximum force were measured. The results indicate that implants with pegs, inclined planes, or domes on the surfaces of the disk will add significantly to the shear stability of the implant while maintaining the simplicity of a single part device.

Animals↗

Bone graft and bone graft substitutes: a review of current technology and applications.

The morbidity associated with autogenous bone graft harvest and the recent concern regarding the transmission of live virus through use of allografts, have been the impetus for research into a variety of materials that could take the place of these standard materials for bone grafting. The positive results reported with various ceramics and/or bone derivatives suggest the possibility of a material with osteoconductive and/or osteoinductive properties for use with or in place of bone graft. This review discusses a variety of bone graft and bone graft substitute materials. Among the osteoconductive materials outlined are the hydroxyapatite and tricalcium phosphate ceramics as well as some reportedly osteoactive polymers. While osteoconduction is a favorable quality, much interest has focussed on the use of osteoinductive or osteogenic materials such as demineralized bone matrix or bone derivatives, that is, BMP, osteogenin, etc. It is increasingly apparent that these materials require a carrier vehicle for optimal expression of osteoactivity. Therefore, the review finishes with a comparison of the various materials suggested for use as carriers.

Bone Transplantation↗

Enhanced osseointegration of hydroxylapatite implant material.

This study was undertaken to determine whether the addition of calcium sulfate to hydroxylapatite (HA) implant material would improve its working properties without adversely affecting its osseointegration. The clinical and histologic examinations of bone response of three implant materials, hard tissue replacement (HTR), HA, and HA composite (HA plus calcium sulfate), were performed after 2-, 4-, and 6-week implantation in tibia and mandible of rabbits. No sign of extensive chronic inflammatory response was detected. The highest rate of bone ingrowth occurred with the HA composite, followed by HA, with HTR showing the least ingrowth. Bone was deposited directly on the surface of HA and HA composite implant materials. In contrast, HTR particles had a thin layer of fibrous tissue encapsulation with the normal bony investment.

Analysis of Variance↗

QSARs and PARs for biodegradation of PCBs.

Relationships between the biodegradation rate constants of a number of polychlorinated biphenyls (PCBs) and hydrophobic and electronic structural parameters are compared. There is no simple relationship with octanol-water partition coefficients, indicating that the biodegradation rates of PCBs are probably not determined by their rates of permeation through the bacterial membranes. Biodegradation rate constants correlated much better with both the electronic and hydrophobic properties of the chlorine substituents, which suggests that the reactivity and possibly enzyme binding of PCBs control their biodegradation rates.

Acinetobacter↗

Effects of environmental exposure on carbon polysulphone composites.

In vivo and in vitro studies were designed to characterize the material degradation associated with implantation of carbon fibre-reinforced polysulphone (C/PS). Composite plates were compression moulded for both studies, and a fibre orientation of 0 degrees with the long axis and a fibre volume fraction of approximately 55% were used. The in vitro experiment involved soaking three groups of four plates each at 4, 12 and 26 wk in 0.9% saline solution at 37 degrees C. The plates were measured for weight gain after each time period and mechanically tested non-destructively in four-point bending to determine modulus. The in vivo experiment involved implanting three groups of eight composite plates (24 total) subcutaneously in the abdomens of 12 rabbits (two implants/animal). Implants were harvested at 4, 12 and 26 wk after implantation and evaluated for changes in weight or modulus of elasticity. In vitro results showed a statistically significant (P less than 0.05 paired t-test) increase in weight for all time periods: 0.41, 1.25 and 0.93% weight gain for the 4, 12 and 26 wk periods respectively. In vivo results were similar to those in vitro: 0.66, 1.06 and 1.15% weight gain for the 4, 12 and 26 wk periods respectively (P less than 0.05 paired t-test). There was no statistically significant difference between the pre- and post-implantation modulus of elasticity for any time period in vivo or in vitro. However, in both studies, on average, the modulus tended to increase with environmental exposure.

Animals↗

Biomechanical comparison of fixation devices in experimental scaphoid osteotomies.

This study determined the force, bending rigidity, and bending moment at failure of three types of internal fixation systems for the scaphoid bone. A pair of parallel, 0.045-inch Kirschner wires were compared on a paired, bilateral basis with either a Herbert screw or a 3.5 millimeter cannulated screw in repairing a transverse waist osteotomy in cadaver scaphoids. The mean values at failure of the Herbert screw and the cannulated screw versus the paired, parallel Kirschner wires for force (65 N and 77 N versus 23.7 N), rigidity (0.47 Nm2 and 0.54 Nm2 versus 0.16 Nm2) and bending (0.98 Nm and 1.15 Nm versus 0.36 Nm) were approximately three times greater. These differences were statistically significant when compared on a paired basis. This experiment demonstrates that the Herbert screw and cannulated screw are significantly stronger in resisting bending forces than paired, parallel Kirschner wires.

Biomechanical Phenomena↗

A preliminary study of mechanically stress-induced changes in the extracellular matrix of the canine intervertebral disc.

The intervertebral discs of a young (age, 3 years) and an old (age, 8 years) dog were isolated as motion segments and cyclically stressed in physiologic nondestructive axial compression loads. Chemical analysis of the matrix of the annulus fibrosus revealed a shift in proteoglycan molecular size from larger to smaller moieties for the older dog but not for the younger. These preliminary results may indicate an age-related inability of the disc to tolerate cyclic stress.

Aging↗

Development of a prosthetic intervertebral disc.

This article is a preliminary report of a 10-year investigation of the development of an intervertebral disc prosthesis. Spinal fusion is a method for the treatment of chronic, disabling low-back pain that does not respond to nonoperative treatments. Spinal fusion, however, has various adverse effects, and the results of spinal fusion are often unpredictable. The goal of this research project was to develop disc prostheses that have mechanical properties very similar to those of natural, normal discs. Two types of disc prosthesis, one with fiber-reinforced polyurethane and the other with multicomponent, non-fiber-reinforced polymers (C-Flex), have been designed and manufactured. The fiber-reinforced disc was made of polyurethane end-plates with A100 hardness, a homogenous nucleus with A40, and 12 layers of multidirectional (0, +45 degrees), fiber-reinforced anulus with A40 polyurethane. The design and modeling of the multicomponent polymers (non-fiber-reinforced) was made of C-Flex endplates with A90 hardness, a nucleus with A35 occupying 35% of the volume, and an anulus with 70A. Mechanical testing of these disc prostheses demonstrated similar mechanical properties to those of natural, normal discs.

Biocompatible Materials↗

Gunshot wounds to the extremities. Experience of a level I trauma center.

Gunshot wounds to the extremities are more common today, largely because civilian handgun injuries have increased. Such injuries, which are usually caused by low-velocity missiles, should be treated differently from those caused by high-velocity (military) missiles. Bone involvement, including fractures and joint injuries, necessitates orthopaedic management. At the University of Medicine and Dentistry of New Jersey-New Jersey Medical School's (UMDNJ-NJMS) University Hospital, a level I trauma center, 44 gunshot wounds (32 lower-extremity and 12 upper-extremity) with orthopaedic complications were treated between January 1986 and December 1988. The protocol/questionnaire used by the UMDNJ-NJMS is presented here to assist the orthopaedic surgeon in the evaluation and treatment of these problematic injuries.

Adolescent↗

Comparison of bovine collagen xenografts to autografts in the rabbit.

The use of bovine tendon as a xenograft material in humans is attractive because of its ready availability and favorable mechanical characteristics. Previous research has shown that the fibroblasts and some extracellular proteoglycans and glycoproteins, not the collagen matrix itself, in bovine tendon are primarily responsible for its antigenicity. Various attempts have been made to decrease the antigenicity of these grafts. A chloroform/methanol (CM) extraction procedure has been developed that selectively removes the fibroblasts from bovine tendon without destroying the collagen matrix. The mechanical, immunologic, and local host tissue responses to these grafts were compared to autografts and to untreated and glutaraldehyde-treated bovine tendon xenografts. The humoral immune response to a purified bovine Type I collagen product was also studied. The central two-thirds of a rabbit Achilles tendon were replaced with a reversed autograft or an experimental graft. Histologic examination of one- and two- week specimens showed an acute inflammatory response to all grafts. Untreated grafts stimulated a severe inflammatory response and were almost completely resorbed by two weeks. Glutaraldehyde-treated grafts were encapsulated. Cellular repopulation was minimal and inflammatory response was more persistent than in the autograft and CM groups. Inflammatory response to CM-treated grafts was similar to that of autografts. The CM grafts repopulated rapidly with host cells. The mechanical strength of CM grafts was equal to autograft controls at 12 weeks. The mechanical strength of untreated and glutaraldehyde-treated grafts was significantly lower. Measurement of the humoral immune response to these grafts was conducted in an independent group of animals using an enzyme-linked immunosorbent assay. A significant antibody response to untreated, glutaraldehyde-fixed, and CM-treated grafts was detected at 30 days. Antibody titers to glutaraldehyde-fixed and untreated grafts remained elevated at 60 and 90 days. In the CM group, antibody titers decreased to the level of autograft controls by 90 days. No significant antibody response was detected toward purified bovine Type I collagen.