Determination of the mean cross-sectional area of the thoracic aorta using a double indicator dilution technique.

A double indicator dilution technique for determining the mean cross-sectional area (CSA) of a blood vessel in vivo is presented. Analogous to the thermodilution method, dilution of hypertonic saline was measured by an electrical conductance technique. Because the change in conductance rather than absolute conductance was used to calculate CSA, pulsatile changes in shear rate of blood and conductance of surrounding tissues had no effect on the data. To calculate CSA from an ion mass balance, cardiac output was needed and estimated from the thermodilution curve using the same "cold" (hypertonic) saline injection. The mean CSA, obtained from this double indicator dilution method (CSAGD), was compared with the CSA obtained from the intravascular ultrasound method (IVUS) in 44 paired observations in six piglets. The regression line is close to the line of identity (CSAGD = -1.83 + 1.06 . CSAIVUS, r = 0.96). The difference between both CSAs was independent of the diameter of the vessel, on average -0.99 mm2 +/- 2.64 mm2 (mean CSAGD = 46.84 +/- 8.21 mm2, mean CSAIVUS = 47.82 +/- 9.08 mm2) and not significant. The results show that the double indicator dilution method is a reliable technique for estimating the CSA of blood vessels in vivo.

Anatomy, Cross-Sectional↗

Single injection thermodilution. A flow-corrected method.

BACKGROUND: Application of the Stewart-Hamilton equation in the thermodilution technique requires flow to be constant. In patients in whom ventilation of the lungs is controlled, flow modulations may occur leading to large errors in the estimation of mean cardiac output. METHODS: To eliminate these errors, a modified equation was developed. The resulting flow-corrected equation needs an additional measure of the relative changes of blood flow during the period of the dilution curve. Relative flow was computed from the pulmonary artery pressure with use of the pulse contour method. Measurements were obtained in 16 patients undergoing elective coronary artery bypass surgery. In 11 patients (group A), pulmonary artery pressure was measured with a catheter tip transducer, in a partially overlapping group of 11 patients (group B), it was measured with a fluid-filled system. For reference cardiac output we used the proven method of four uncorrected thermodilution estimates equally spread over the ventilatory cycle. RESULTS: A total of 208 cardiac output estimates was obtained in group A, and 228 in group B. In group B, 48 estimates could not be corrected because of insufficient pulmonary artery pressure waveform quality from the fluid-filled system. Individual uncorrected Stewart-Hamilton estimates showed a large variability with respect to their mean. In group A, mean cardiac output was 5.01 l/min with a standard deviation of 0.53 l/min, or 10.6%. After flow correction, this scatter decreased to 5.0% (P < 0.0001). With no bias, the corresponding limits of agreement decreased from +/- 1.06 to +/- 0.5 l/min after flow correction. In group B, the scatter decreased similarly and the limits of agreement also became +/- 0.5 l/min after flow correction. CONCLUSION: It was concluded that a single thermodilution cardiac output estimate using the flow-corrected equation is clinically feasible. This is obtained at the cost of a more complex computation and an extra pressure measurement, which often is already available. With this technique it is possible to reduce the fluid load to the patient considerably.

Adult↗

Transfer of carbon monoxide during an inspiratory pause procedure in mechanically ventilated pigs.

We studied the effect of forced inflation at different alveolar volumes (VA) on carbon monoxide diffusing capacity (DLCO) in anaesthetized, paralysed and mechanically ventilated healthy pigs. An inspiratory pause procedure (equivalent of the single-breath technique) consisting of a pause between an inflation and expiration, both at a constant flow rate, was used. The procedure was computer-controlled and could easily be standardized. In five pigs, VA was varied at constant inflation volume by increasing positive end-expiratory pressure (PEEP) from 2 to 10 cmH2O. Inspiratory pause time was varied from 1 to 8 s to verify whether the decay of CO was exponential. In nine pigs, DLCO was estimated at four different VA values by inflating with 15-30 ml kg-1 at 2 cmH2O PEEP. An exponential decay of CO was always obtained. With increasing VA by either an increase in PEEP or inflation volume, DLCO remained constant. Since the diffusing capacity of the pulmonary membrane is expected to increase with increasing VA, the constant DLCO may be attributed to a decrease in capillary blood volume.

Animals↗

Beat-to-beat analysis of left ventricular pressure-volume relation and stroke volume by conductance catheter and aortic Modelflow in cardiomyoplasty patients.

BACKGROUND: Since the clinical introduction of dynamic cardiomyoplasty, a discrepancy has been observed between unchanged measurements of cardiac function and improved clinical outcome. METHODS AND RESULTS: We performed a beat-to-beat analysis of cardiac performance at rest in nine cardiomyoplasty patients 6 to 24 months after operation. Conductance and micromanometer catheters were placed in left ventricle and aorta and used for measurements over a 15-second period, during which the wrapped latissimus dorsi (LD) muscle was stimulated for 10 seconds in a 1:2 synchronization mode followed by a 5-second period without LD stimulation. The synchronization delay between start of the QRS complex and the LD contraction was changed from 4 up to 125 ms at the patient's clinical stimulation strength and at an increased supramaximal amplitude. Comparing the LD assisted period to the unassisted period, at the clinical settings no significant changes in stroke volume (SV) as measured by the conductance technique and the aortic Modelflow technique were observed. A significant (P < .05) rise in left ventricular end-diastolic pressure (LVEDP) was observed directly after the assisted 10-second period. The peak ejection rate (PER) of left ventricular volume increased (P < .05), with a mean of 28 +/- 23% during the LD stimulated beats. At the patient's individual best setting, SV of the stimulated beats increased (P < .01) by a mean of 20 +/- 15%. Systolic aortic pressure increased (P < .01) by a mean of 7 mm Hg, peak negative dP/dt increased (P < .01), and PER increased, with a mean of 68 +/- 24% (P < .01). LVEDP was similar in stimulated and unstimulated beats and increased (P < .05) in the nonpaced 5-second period. The delay for the best setting ranged from 25 to 125 ms; the stimulus strength was 1.5 to 3 V higher than the clinical setting. At the patient's individual worst setting, SV remained unchanged and PER was higher, with a mean of 30 +/- 25% (P < .05). The worst setting was observed at the 1.5- to 3-V-higher stimulus strength; in six patients, it was at a short delay (4 to 25 ms) and in three patients, at the longest delay (100 to 125 ms). CONCLUSIONS: By the left ventricular conductance catheter and aortic Modelflow methods, improvement in cardiac function by dynamic cardiomyoplasty was demonstrated in this patient group. The synchronization interval, stimulus strength, and stimulus duration appeared to be critical for obtaining optimal improvement.

Aged↗

Alternating versus synchronous ventilation of left and right lungs in piglets.

OBJECTIVE: We tested whether alternating ventilation (AV) of each lung (i.e. with a phase difference of half a ventilatory cycle) would decrease central venous pressure and so increase cardiac output when compared with simultaneous ventilation (SV) of both lungs. THEORY: If, during AV, the inflated lung expands partly via compression of the opposite lung, mean lung volume will be smaller during AV than SV. As a consequence, mean intrathoracic pressure (as cited in the literature), and therefore, central venous pressure will be smaller. DESIGN: The experiments were performed in seven anaesthetized and paralyzed piglets using a double-piston ventilator. Minute ventilation was the same during AV and SV. Starting at SV, we alternated three times between AV and SV for periods of 10 min. RESULTS: During AV, central venous pressure was decreased by 0.7 mmHg and cardiac output was increased by 10 +/- 4.4% (mean, +/-SD) compared with SV. AV also resulted in increased arterial pressure. During one-sided inflation with closed outlet of the opposite lung, a pressure rise occurred in the opposite lung, indicating compression. CONCLUSION: The higher cardiac output during AV than SV can be explained by the fact that central venous pressure is lower during AV. This lower central venous pressure is very probably due to the lower mean intrathoracic pressure caused by compression of the opposite lung during unilateral inflation.

Animals↗

Systemic filling pressure in intact circulation determined on basis of aortic vs. central venous pressure relationships.

In the intact circulation, mean systemic filling pressure (Psf) is determined by applying a series of inspiratory pause procedures (IPPs) and using Guyton's equation of venous return (Qv) and central venous pressure (Pcv): Qv = a - b x Pcv. During an IPP series, different tidal volumes are applied to set Pcv at different values. From the linear regression between Qv and Pcv, Psf can be calculated as Psf = a/b. Guyton's equation can also be written as Qv = (Psf - Pcv)/Rsd, where Rsd is the flow resistance downstream of the places where blood pressure is equal to Psf. During an IPP, a steady state is observed. Therefore, we can also formulate the following equation for flow: Qs = (Pao - Psf)/Rsu, where Qs is systemic flow, Rsu is the systemic flow resistance upstream to Psf, and Pao is aortic pressure. Because both flows (Qs and Qv) are equal, it follows that Pao = Psf(1 + Rsu/Rsd) - Rsu/Rsd x Pcv. This equation implies a method to determine mean systemic filling pressure on the basis of Pao measurements instead of flow determinations. Using 22 IPPs in 10 piglets, we determined the mean systemic filling pressure, and we compared the values obtained from the flow curves with those obtained from the aortic pressure curves. The mean difference between the two methods was 0.03 +/- 1.16 mmHg. With the use of Pao measurements, the Psf can be estimated as accurately as in using flow determinations. The advantage of the new method is that estimation of cardiac output is not required.

Animals↗

Tidal variation of pulmonary blood flow and blood volume in piglets during mechanical ventilation during hyper-, normo- and hypovolaemia.

Effects of changes in blood volume on changes in pulmonary blood flow and pulmonary blood volume during the ventilatory cycle during mechanical ventilation with a positive end-expiratory pressure of 2 cm H2O were determined in six pentobarbital anaesthetized, curarized pigs weighing about 10 kg. Haemodynamic variables were analysed for each cardiac cycle in eight ventilatory cycles in four consecutive series under hyper-, normo- and hypovolaemic conditions. Cardiac output was highest in hypervolaemia. Compared with normo- and hypovolaemia, it decreased less during inflation, due to a smaller rise in central venous pressure and presumably a larger filling state of the venous system. The smaller decrease in right ventricular output in hypervolaemia coincided with a larger fall in transmural central venous pressure (right ventricular filling pressure), due to right ventricular action at a higher, less steep part of its function curve. The difference between right ventricular-output (electromagnetic flow measurement) and left ventricular-output (pulse contour) indicated changes in pulmonary blood volume. In hypervolaemia less blood shifted from the pulmonary circulation into the systemic system during inflation than in normo- and hypovolaemia. This difference can be explained by two mechanisms namely, the smaller fall in input into the pulmonary vascular beds and a smaller pulmonary vascular volume decrease as a result of transmural pressure fall at a steeper part of the pressure-volume curve.

Animals↗

Computation of aortic flow from pressure in humans using a nonlinear, three-element model.

We computed aortic flow pulsations from arterial pressure by simulating a nonlinear, time-varying three-element model of aortic input impedance. The model elements represent aortic characteristic impedance, arterial compliance, and systemic vascular resistance. Parameter values for the first two elements were computed from a published, age-dependent, aortic pressure-area relationship (G. J. Langewouters et al. J. Biomech. 17:425-435, 1984). Peripheral resistance was predicted from mean pressure and model mean flow. Model flow pulsations from aortic pressure showed the visual aspects of an aortic flow curve. For evaluation we compared model mean flow from radial arterial pressure with thermodilution cardiac output estimations, 76 times, in eight open heart surgical patients. The pooled mean difference was +7%, the SD 22%. After using one comparison per patient to calibrate the model, however, we followed quantitative changes in cardiac output that occurred either during changes in the state of the patient or subsequent to vasoactive drugs. The mean deviation from thermodilution cardiac output was +2%, the SD 8%. Given these small errors the method could monitor cardiac output continuously.

Aged↗

PDPS: a pulmonary data processing system for assessment of gas exchange properties by multiple gas wash-out.

A data acquisition and processing system for the analysis of inert gas wash-out tests is described. The described system is in clinical use on spontaneously breathing patients as well as on mechanically ventilated Intensive Care patients. It combines several analysis techniques with an aim to provide a deeper insight into the nature of existing ventilation inhomogeneity than the individual techniques alone can provide. The signals measured are the respiratory flow, the fractions of one or two indicator gases washing out and the fractions of the metabolic gases oxygen and carbon dioxide. Analysis of these signals provides information concerning the end-expiratory lung-volume, distribution of ventilation and perfusion in the lung, the role of diffusion in the ventilation process and the metabolic oxygen uptake and CO2 release. This article describes the algorithms used and the results that are presented.

Algorithms↗

Alveolar pressure during high-frequency jet ventilation.

We studied the influence of ventilatory frequency (1-5 Hz), tidal volume, lung volume and body position on the end-expiratory alveolar-to-tracheal pressure difference during high-frequency jet ventilation (HFJV) in Yorkshire piglets. The animals were anesthetized and paralysed. Alveolar pressure was estimated with the clamp off method, which was performed by a computer controlled ventilator and which had been extensively tested on its feasibility. The alveolar-to-tracheal pressure difference increased with increasing frequency and with increasing tidal volume, the common determinant appearing to be the mean expiratory flow. The effects in prone and in supine position were similar. Increasing thoracic volume decreased the alveolar-to-tracheal pressure difference indicating a dependence of this pressure difference on airway resistance. We concluded that the main factors determining the alveolar-to-tracheal pressure difference (delta P) during HFJV are expiratory flow (V'E) and airway resistance (R), delta P congruent to V'E x R.

Airway Resistance↗

An adequate strategy for the thermodilution technique in patients during mechanical ventilation.

The application of the thermodilution method in conditions associated with variations in blood flow implies a misuse of the Stewart Hamilton equation. Therefore, we studied the reliability of the thermodilution method for the estimation of mean cardiac output (CO) during mechanical ventilation in patients (n = 9). Variation of the injection moment in the ventilatory cycle elicited a cyclic variation of CO estimates. This variation was not the same for all patients neither in phase nor in amplitude. Therefore, no specific phase in the ventilatory cycle could be selected for an accurate estimation of mean CO. Averaging CO estimates randomly distributed in the ventilatory cycle led to an improvement of accuracy with the square root of the number of observations. The averaging of CO estimates spread equally over the ventilatory cycle led to a much better result, e.g., the variation in the average of two estimates equally spread in the ventilatory cycle was similar to the variation in the average of four random estimates. We conclude that averaging of 3 or 4 estimates spread equally over the ventilatory cycle is an adequate strategy to estimate mean cardiac output in patients reliably.

Aged↗

Continuous cardiac output monitoring by pulse contour during cardiac surgery.

Most pulse contour methods are unreliable under changing haemodynamic conditions, because no corrections are made for pressure-dependent compliance and reflections of pressure waves. The pulse contour method of Wesseling includes such corrections. Four thermodilution measurements equally spread over the ventilatory cycle were used to calibrate and evaluate this pulse contour method. We designed a prototype incorporating a combination of the thermodilution method and pulse contour method and evaluated its potential for monitoring patients undergoing coronary bypass graft operation. Eight to 12 times during the operation, cardiac output was estimated by pulse contour and by thermodilution. The results were compared: the linear regression between the methods was COpc = 0.3 + 0.94. COth, (r = 0.94). The standard deviation for the difference between the methods against the mean of the methods was 10.6%. We concluded that the corrected pulse contour method estimates cardiac output accurately, even when heart rate, blood pressure, and total peripheral resistance change substantially.

Blood Pressure↗

Negative effect of insufflation on cardiac output and pulmonary blood volume.

In 14 anaesthetized young pigs the changes in pulmonary blood flow and pulmonary blood volume (Qp) during mechanical ventilation were quantified. Ventilation was performed at 10 cycles per min and tidal volume (VT) was adjusted to an arterial PCO2 of about 40 mmHg (5.3 kPa). In 4 animals, 7 ventilatory cycles with an inspiratory pause (IP) of 7.2 s but different tidal volumes were inserted at intervals of 5 min to determine the decrease in Qp (delta Qp) from the differences between right ventricular (Qs,rv) and left ventricular (Qs,lv) stroke volume, and to relate delta Qp to VT. We measured pressure in the aorta (Pao), central veins (Pcv), right and left ventricles (Prv, Plv) pericardium (Pit), and trachea (PT). Blood flow was measured electromagnetically (EM) in the pulmonary artery (Q'pa) and aorta (Q'ao). Stroke volumes were derived from the EM-flow curves. In the other 10 experiments, Qs,lv was derived from the aortic pulse contour. Beat-to-beat analyses of Qs,rv and Qs,lv and blood pressures during the normal ventilatory cycles and those with an IP revealed the following: 1) The end-expiratory RV output and LV output were constant and were defined as baseline values. 2) The accumulated decrease in Qs,rv during insufflation caused a mean deficit in cardiac output of 10.3 +/- 3.2% (s.d.), n = 135; the same was found for Qs,lv, indicating the pulse contour as a useful method to estimate the variations in cardiac output during a ventilatory cycle.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

A computerized respiratory system including test functions of lung and circulation.

The design of a microcomputer-controlled ventilator for automatic performance of lung function and circulatory tests has been described. It incorporates the characteristics of normal mechanical ventilation and also allows one to perform a multitude of test procedures for lung function and circulatory studies in paralyzed animals. The major components of the setup are a pump assembly with solenoid valves to direct gas flow, an electromechanical servo system, and a MS-DOS microcomputer system. The pump assembly has been constructed as a relatively simple device. Great versatility is created by the use of a microcomputer for the control of the ventilator. The software can be easily adapted to several other types of experimental studies. Besides the keyboard input the ventilator can be controlled by a remote computer system. This allows one to run an experimental protocol automatically and to use it in closed-loop servo ventilation. The flexibility in the choice of the respiratory parameters makes the ventilator suitable for lung function and circulatory studies during artificial ventilation. The ventilator has been successfully used in different animal studies during the last 6 yr.

Animals↗

Suppression of spontaneous breathing during high-frequency jet ventilation. Separate effects of lung volume and jet frequency.

The effect of ventilatory frequency of high-frequency jet ventilation (HFJV) from 1 to 5 Hz, apart from changes in thoracic volume, on spontaneous breathing activity was studied in Yorkshire piglets under pentobarbital anesthesia. The highest PaCO2 at which the animals did not breathe against the ventilator (apnea point) was established either by changing minute volume of ventilation or by adding CO2 to the respiratory gas. The higher the apnea point, the higher the suppression of spontaneous breathing activity was assumed to be. If the apnea point was searched for by changing minute volume a progressive increase of suppression of spontaneous respiratory activity was found at ventilatory rates of 3 Hz or more, concomitantly with a rise in end-expiratory pressure (PEE). In case the tidal volume was kept constant, increase of ventilatory rate resulted in a tremendous increase of lung volume, together with considerably higher levels of PEE. When under these conditions the apnea point was searched for by adding CO2 to the respiratory gas a much higher CO2-drive was needed for spontaneous breathing and therefore a much stronger inhibition of spontaneous breathing was concluded. By placing the animals in a body box in which pressure could be varied, thoracic volume could be kept constant during HFJV. When thoracic volume was kept constant in this way a constant tidal volume at increasing jet frequencies resulted in only a slight increase in suppression of spontaneous breathing. We conclude that the increase in lung volume is a major factor in suppressing central respiratory activity during HFJV. Jet frequency by itself might be an additional suppressive factor.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Extrapolation of thermodilution curves obtained during a pause in artificial ventilation.

The feasibility of three mathematical models to extrapolate the tail of thermodilution curves, when flectures are present in the descending limb, was tested in anesthetized pigs. The models were a local random walk model (LDRW), a log-normal distribution, and a two-compartment model. First, the accuracy of the extrapolation of the tail by each model was tested on two undisturbed curves by taking the truncation at five different points on the descending limb. The extrapolated curve area obtained from each model was compared with total area of the undisturbed curve. Next, dilution curves obtained during inspiratory hold maneuvers and characterized by deflection points were analyzed, taking the truncation just before deflection. The estimates of cardiac output by the models were compared with electromagnetically measured flow in the pulmonary artery. The area of the dilution curve was estimated more accurately when more information on the descending limb was available. The LDRW model and the log-normal distribution were superior to the two-compartment model regarding accuracy of cardiac output estimation and root-mean-square errors of the fit. Both models estimated curve area with an error less than 5% when truncation of the descending limb occurred below 60% of the peak value. In circumstances of mechanical ventilation, where only short periods of constant flow will be present, analyses of dilution curves based on the LDRW model or the log-normal distribution are recommended.

Animals↗