Search PubMed⌕ Search

Biomedical subjects

J R Ives

Publications and source records attributed to J R Ives.

At least 37 records · Page 2Linked to original sources

High resolution EEG output using a laser printer.

With increasing computerization, digitization and complexity of 64- to 128-channel long-term monitoring (LTM), new problems have arisen with data presentation. We describe customized software that allows for high resolution EEG output on a standard laser printer. This system can display from 1 to 128 channels of EEG on standard or legal size paper with freedom to alter both time and amplitude scales as desired. This technique is inexpensive and provides a high resolution rectilinear paper record of selected EEG events that is convenient for review and storage.

Computers↗

Entry into practice.

Explore the source record for details and available documents.

Education, Nursing, Baccalaureate↗

A 6-pole filter for improving the readability of muscle contaminated EEGs.

A multi-channel switched-capacitor 6-pole filter for significantly reducing the EMG artifact present during seizures recorded by long-term monitoring procedures has been implemented for routine use. This permits repeated replay of the seizures with different filter settings. All of the channels can be simultaneously dialed to any cut-off frequency (3 dB down) between 8 Hz and 70 Hz and the event replayed for filtering and write-out onto any standard EEG machine. The advantage of the 6-pole switched-capacitor filter is that it does not require a complex design with high precision RC components. The cut-off frequency is determined by the frequency of a simple clock that is used to select the same cut-off point for all 16 channels. By changing the clock frequency, the operator moves the cut-off point linearly. The dramatic improvement obtained by off-line digital filtering that was recently reported (Gotman et al. 1981) indicates that more efficient filtering of EMG contaminated seizures is diagnostically significant in selected cases. This approach is limited by the availability and expense of not only the computer's hardware but also the dedicated software. Specially designed 4-pole analog filters (Barlow 1984) are less expensive than digital filtering, but are difficult to design even at specific frequencies and do not allow for a range of frequencies. The switched-capacitor 6-pole filters have all the advantages of the above but are even more efficient in reducing EMG artifact. They also do not have any of the above disadvantages and cost only a few dollars per channel.

Adult↗

Monitoring at the Montreal Neurological Institute.

Long-term monitoring of epileptic patients who are candidates for surgical therapy has developed at the Montreal Neurological Institute and Hospital over the last 15 years. Given the large number of patients being investigated, we had to develop procedures which were not labor-intensive. Our monitoring sessions require only the regular supervision of nursing staff. This allows monitoring to take place 7 days a week and 24 h a day on 2 or 3 patients, with minimal personnel requirement. The work of the EEGer is greatly simplified by the fact that the EEG tracing is reduced to the 'interesting' sections only. This was originally possible because of the concept developed by Ives et al. (1976) of delaying the EEG so that activity prior to perceptible clinical signs were always retained. The automatic detection of interictal spikes and seizures in the EEG complemented very effectively this original method of seizure recording. Video recording plays a critical role in the evaluation of seizure disorders. In order to have the maximum quality of EEG and behavior, we record them on their most appropriate medium, paper and video tape respectively; the two are synchronized by a common clock. EEGs are also recorded on a computer tape or disk and can be further analyzed for clinical and research purposes.

Canada↗

Recording media for the EEG.

Long-term EEG monitoring usually implies the continuous recording (or the continuous monitoring of the EEG coupled with periodic or event recording) of the data on some medium other than paper. This involves a variety of technologies and methodologies and can become fairly complicated depending on the amount of data reduction, data analysis and type of replay used.

Data Display↗

Recording the time of day.

The recording of the time-of-day (TOD) information (e.g., hours, minutes, and seconds) is an important part of a prolonged EEG and video study. The transcribing techniques for this information on paper (chart recorders), video tape, analog tape, and by digital computers are reviewed.

Computers↗

Frequency content of EEG and EMG at seizure onset: possibility of removal of EMG artefact by digital filtering.

EEG recordings of epileptic seizures from scalp and sphenoidal electrodes are frequently obscured by EMG activity from contracting scalp muscles. We have examined the possibility of selectively filtering the EMG artefact in order to make apparent the activity of cerebral origin. It has been shown that, during voluntary contractions of scalp muscles, most of the energy of EMG activity is above 15-20 Hz. We have shown, in recordings from 50 patients, that rhythmic activity at the onset of seizures uncontaminated by artefact had almost always a fundamental frequency lower than 25 Hz. From these two observations, we concluded that total elimination of activity above 25 Hz would eliminate most of the EMG activity, with a minimal risk of eliminating rhythmic cerebral activity. Thirty-one seizure contaminated by EMG activity were analyzed. Spectral analysis was used to assess the presence or absence of rhythmic activity at seizure onset, in the presence of obscuring EMG artefact. The spatial and temporal distribution of such a rhythmic activity was then revealed by a sharp digital filter which did not introduce phase distortions. Seizures recorded on computer tape were played back on paper following filtering. In 16 of the 31 cases it was possible to clarify the originally obscured recordings. In 7 cases, it was found that no rhythmic cerebral activity was hidden by the EMG, a finding which was also important. In the last 8 cases, it was not possible to determine with certainty the origin, cerebral or muscular, of fast rhythmic activity present at seizure onset.

Cerebral Cortex↗

Automatic recognition of inter-ictal epileptic activity in prolonged EEG recordings.

A method of automatic recognition and quantification of inter-ictal epileptic activity in the human EEG had previously been developed and tested using short recordings from awake subjects. This paper describes the adaptation of the method for use during overnight recordings in free-moving unattended patients, in combination with the already existing seizure monitoring system. EEG s were recorded from scalp and sphenoidal electrodes, using cable telemetry and a PDP-12 computer. The spike and sharp wave recognition method allowed the on-line analysis of 16 channels. A section of the 16-channel EEG including 1 sec before and 1 sec after each detected spike was saved on digital magnetic tape. Upon completion of the monitoring session, the tape was played back on the EEG machine, giving a discontinuous tracing of spike sections; this constituted a highly concentrated view of the inter-ictal epileptic activity, in traditional paper form. The spike sections were further analyzed by computer to determine and display on the computer terminal the spatial and temporal distributions of the epileptic activity, providing a complete synopsis of the recording. Several examples of the type of information available from this anslysis are discussed in detail. False detection rates are given for 34 six hour recordings, indicating a high vari ability in the performance, mainly because of artefacts. It is concluded that the final computer displays could only be trusted after visual inspection of the EEG sections provided on paper. The variety of morphologies of artefacts appeared to preclude a total automatic elimination.

Electroencephalography↗

A long term time-lapse video system to document the patients spontaneous clinical seizure synchronized with the EEG.

A long term audio/video clinical seizure monitoring system is described which is complementary to a previously described EEG seizure monitoring system. The video unit is mobile and based on time-lapsed video recording techniques to extend the unattended continuous video recording of the patient to many days if necessary. The simultaneous coverage of the EEG and behavior of the patient particularly during his seizure has been very useful in the workup of intractable epileptic patients being considered for neurosurgical treatment.

Electroencephalography↗

Update: chronic sphenoidal electrodes.

A technical modification in the type of material used in the chronic sphenoidal electrode previously described (Ives and Gloor 1977) has further improved their clinical use and benefit of the EEG work-up of epileptic patients. This procedure has become a routine investigation for all patients with suspected temporal lobe epilepsy at the Montreal Neurological Hospital.

Electrodes, Implanted↗

Automatic noctural sleep sampling: a useful method in clinical electroencephalography.

The clinical usefulness of obtaining a sleep record in epileptic patients is well established. However, in many clinical EEG laboratories, it is difficult to obtain records at night during the patient's natural sleep. Thus, most sleep EEGs are recorded in the EEG laboratory during daytime and are induced by drugs. A 16 channel cable-telemetry system is described which automatically samples throughout the night the EEG of patients while sleeping in their room or ward without the aid of any medication. The electrodes and the cable-telemetry unit are applied to the patient in the afternoon and the system is checked. The patient is then instructed to plug the system into a wall box upon retiring and to disconnect it when he wakes up in the morning. The EEG samples are automatically written out during the night on one of the EEG machines located in the EEG laboratory to which the system is connected via spectral intra-hospital wiring. The duration of the samples and of the intervals separating them can be varied according to the circumstances. We have found this method to be very helpful in the investigation of epileptic patients, especially those considered for surgical treatment.

Electroencephalography↗

New sphenoidal electrode assembly to permit long-term monitoring of the patient's ictal or interictal EEG.

A new sphenoidal wire electrode is described which greatly increases the clinical and diagnostic usefulness of sphenoidal electrode recordings. These very fine wire electrodes are easy to insert; they are comfortable and acceptable to the patient. In contrast to sphenoidal needle electrodes they expose the patient to no risk should he have a seizure during recording. These electrodes also allow one to extend the recording time to several days, thus increasing the chances of recording a spontaneous seizure, for instance while the patient's EEG is being recorded with a telemetry system. The extended recording time also allows for continuous automatic sampling of the interictal EEG over a period of several days. The quality and the reliability of the EEG record are also enhanced. The new sphenoidal electrodes have been used on over 100 patients and are now being used routinely on suspected temporal lobe epileptics recorded with conventional techniques, while 50 of the patients have also been recorded with a cable-telemetry seizure monitoring system which has captured 65 spontaneous seizures.

Electrodes, Implanted↗

Seizure moitoring: a new tool in electroencephalography.

A seizure monitoring system, based on telemetry and computer techniques, has been developed to provide a reliable means of recording the patient's spontaneous seizures. It allows a patient's EEG to be monitored for hours or days with 16 channels of EEG from surface, sphenoidal or stereotaxically implanted depth electrodes, from any ward or room within the hospital. The EGG is delayed in time by up to 4 min by a mini-computer so that either the patient can push a button when he experiences his aura or others can push the button when they observe his seizure. Since the delayed EEG is written out, the preictal, ictal and postictal are recorded on paper, without many pages of uneventful interictal information. During the past 16 months, the seizure monitoring system has been used as a clinical service to examine patients with surface electrodes (42), sphenoidal wires (25) and depth electrodes (7) during 146 recording sessions for over 3200 h of monitoring time while over 200 seizures have been recorded.

Amplifiers, Electronic↗