Search PubMed⌕ Search

Biomedical subjects

J R Glasson

Publications and source records attributed to J R Glasson.

24 records · Page 2Linked to original sources

Three-dimensional dynamics of the canine mitral annulus during ischemic mitral regurgitation.

BACKGROUND: It has been suggested that ischemic mitral regurgitation results, at least in part, from generalized end-systolic mitral annulus (MA) dilatation, but the role of the MA is incompletely understood and the segmental dynamics of the MA during left ventricular ischemia have not been described. METHODS: We used radiopaque markers and simultaneous biplane videofluoroscopy to measure three-dimensional in vivo lengths of eight MA segments in 7 sedated dogs before and after induction of ischemic MR (produced by circumflex coronary artery balloon occlusion and verified by Doppler echocardiography). As viewed from the left atrium, the MA segment between markers 1 and 2 (S12) was defined as starting at the posteromedial commissure, and remaining segments were numbered sequentially clockwise around the MA (ie, the posterior MA encompassed S12, S23, S34, S45,; the anterior MA included S56, S67, S78, S81). Marker images obtained 7 to 12 days after implantation were used to construct x, y, and z coordinates of each marker at end-diastole and end-systole. RESULTS: During regional (posterolateral walls) left ventricular ischemia, the end-systolic MA area increased (4.9 +/- 0.8 cm2 [control] versus 5.9 +/- 0.6 cm2; p = 0.005). End-systolic MA segment lengths were as follows (control, ischemia [mm, mean +/- standard deviation]): S12 = 9 +/- 2, 10 +/- 3; S23 = 10 +/- 2, 12 +/- 3; S34 = 13 +/- 1, 15 +/- 1; S45 = 8 +/- 2, 9 +/- 2; S56 = 11 +/- 2, 11 +/- 2; S67 = 12 +/- 2, 12 +/- 2; S78 = 10 +/- 3, 11 +/- 2; and S81 = 11 +/- 1, 12 +/- 1. Values for S12, S23, S34, and S81 were significant (p < or = 0.05 for control versus ischemia by paired t test). CONCLUSIONS: During ischemic mitral regurgitation, the MA enlarged at end-systole, but in an asymmetric manner; most posterior annular segments lengthened, whereas most anterior annular segment lengths did not change. These data suggest that alterations in regional MA mechanics may be important in the pathogenesis of ischemic mitral regurgitation. Further three-dimensional studies of MA dynamics and shape should be conducted so that new knowledge may result in improved mitral valve surgical techniques.

Animals↗

Three-dimensional regional dynamics of the normal mitral anulus during left ventricular ejection.

The mitral anulus is a dynamic structure that undergoes alterations in size and shape throughout the cardiac cycle, contracting during systole. Numerous reports have shown this systolic orifice reduction to be due chiefly to posterior annular contraction, whereas the anterior perimeter was unchanged. Segmental motion of the mitral anulus from true in vivo three-dimensional data, however, has not been described. We used radiopaque markers and simultaneous biplane videofluoroscopy to measure the lengths of mitral anular segments in seven closed-chest, sedated dogs. Eight markers were placed equidistant from each other around the mitral anulus, As viewed from the left atrium, segment 1 began at the posteromedial commissure, and the remaining segments were numbered sequentially clockwise around the anulus (that is, the posterior mitral anulus encompassed segments 1 to 4 and the anterior anulus encompassed segments 5 to 8). Marker image coordinates obtained from two orthogonal views 7 to 12 days after implantation were merged to construct three-dimensional marker coordinates at end-diastole and end-systole. From end-diastole to end-systole, mean annular area decreased by 11% +/- 8% (5.5 +/- 0.9 cm2 to 4.9 +/- 0.8 cm2, p = 0.005) and perimeter by 5% +/- 4% (8.8 +/- 0.7 cm to 8.3 +/- 0.7 cm, p < 0.01). Mitral annular segmental percent systolic shortening (negative values indicate lengthening) were as follows (mean +/- standard deviation): segment 1, 7% +/- 9%; segment 2, 8% +/- 10%; segment 3, 16% +/- 6%; segment 4, 10% +/- 7%; segment 5, -4% +/- 5%, segment 6, -7% +/-7%; segment 7, 3% +/- 2%; and segment 8, 6% +/- 5%. With the exception of segment 1, all posterior (2 to 4) and two anterior (7 and 8) mitral annular segments contracted significantly (p < or = vs zero, paired t test). Two anterior annular segments (5 and 6, regions overlapping aortic-mitral continuity), however, unexpectedly lengthened during left ventricular systole. We conclude that the anterior mitral anulus may be a much more dynamic component of the mitral apparatus that previously thought. Such heterogeneous dynamic annular motion should be taken into account when various mitral valve reparative techniques are being designed.

Animals↗

Improving methods of chordal-sparing mitral valve replacement--Part II: Optimal tension for chordal resuspension.

BACKGROUND AND AIMS OF THE STUDY: Although chordal-sparing mitral valve replacement (MVR) is popular, the optimal tension for preserved or reattached chordae tendineae (CT) or for synthetic (ePTFE) CT is unknown. METHODS: Changes in left ventricular (LV) systolic and diastolic function in nine dogs with anterior CT preservation with different levels of end-diastolic chordal tension (0, 10, 20, 30, and 40 gm, measured by spring scale) were compared using an isovolumic double-balloon technique. RESULTS: LV function data at each level of tension were compared to control data using 0 gm of tension. Systolic function assessed as Emax (mmHg/ml) at 10, 20, 30, and 40 gm versus control was: 5.7 +/- 2.6/4.9 +/- 2.7, 4.7 +/- 2.2/4.7 +/- 2.7, 4.8 +/- 3.1/4.7 +/- 2.8, and 5.0 +/- 3.5/5.1 +/- 2.9; delta improvement from the control at 10 gm was larger than that at 20 gm (p < 0.05 by paired t-test). Diastolic function assessed as diastolic stiffness (Sd, mmHg/ml) at the same CT tensions versus control was: 0.56 +/- 0.23/0.56 +/- 0.34, 0.53 +/- 0.30/0.57 +/- 0.37, 0.56 +/- 0.39/0.52 +/- 0.38, and 0.60 +/- 0.36/0.58 +/- 0.39; delta Sd was smaller at 20 gm than at 30 gm (p = 0.05 by ANOVA). LV equilibrium volume (Veq, ml) was: 10.7 +/- 3.9/10.1 +/- 3.9, 9.6 +/- 3.4/9.9 +/- 3.8, 10.8 +/- 4.0/10.3 +/- 3.4, and 10.6 +/- 4.0/10.6 +/- 3.5; delta Veq was larger (i.e., more compliant chamber) at 10 gm than at 40 gm (p < 0.05 by rm-ANOVA). Arrhythmias precluding satisfactory measurements occurred in two dogs at 30 or 40 gm CT tension. CONCLUSIONS: With chordal tension exceeding 10 gm, which is barely palpable, there was no additional enhancement in LV systolic function compared to zero CT tension. Veq was largest at the lowest tension; LV diastolic function (assessed as Sd) deteriorated with tensions of 30 gm or higher. The optimal end-diastolic tension of preserved CT should enhance systolic LV performance without adversely affecting diastolic function; in this isovolumic model, minimal CT tension (10 gm) best met these goals. Excessive tension may negate the potential hemodynamic benefits of chordal preservation during mitral valve replacement.

Animals↗

Improving methods of chordal-sparing mitral valve replacement--Part III: Optimal direction for artificial chordae.

BACKGROUND AND AIMS OF THE STUDY: The optimal direction to preserve artificial chordae tendineae (CT) during mitral valve replacement (MVR) is not known, especially in regard to the response to inotropic stimulation which simulates exercise conditions. METHODS: Using a non-distorting isovolumic balloon technique, we compared left ventricular (LV) systolic and diastolic mechanics in 11 dogs in a control state (no chordal sparing) and with four different methods of chordal preservation: posterior, anterior, oblique (anterior papillary muscle chordae directed anteriorly and others posteriorly, the direction which theoretically augments LV systolic twist), and counter-oblique (counter, chordae preserved in directions opposite to oblique). RESULTS: Before dobutamine, delta Emax from the control was: 0.32 +/- 0.82, 0.10 +/- 0.43, 0.64 +/- 1.07, and 0.51 +/- 0.78 (anterior, posterior, oblique, and counter method, respectively). With dobutamine (3 mg/kg/min), delta Emax (mmHg/ml) was: 0.41 +/- 1.21, -0.13 +/- 0.75, 0.59 +/- 0.82*, and -0.34 +/- 0.71. Before dobutamine, delta LV stiffness (Sd, mmHg/ml) was -0.01 +/- 0.09, -0.02 +/- 0.12, 0.02 +/- 0.10, and 0.01 +/- 0.12; with dobutamine it was 0.01 +/- 0.09, 0.00 +/- 0.15, 0.03 +/- 0.15, and -0.06 +/- 0.11. Similarly, before dobutamine delta LV equilibrium volume (Veq) was -1.2 +/- 3.8, -0.3 +/- 3.0, -0.7 +/- 2.7, and -0.2 +/- 3.5, whereas with dobutamine zeta eq was -0.1 +/- 1.1, -0.4 +/- 0.8, 0.6 +/- 1.7, and -0.4 +/- 1.1. (Mean +/- S.D.; *p = 0.005 posterior and counter by ANOVA; p = NS (< 0.06) versus counter and posterior by ANOVA). CONCLUSIONS: The oblique method enhanced systolic LV function both with and without dobutamine, while a tendency towards better diastolic LV function (Veq) was observed with dobutamine. The anterior method was next best in preserving systolic function, both with and without dobutamine. LV diastolic function tended to deteriorate with dobutamine in the posterior group. Systolic function with the counter method deteriorated with dobutamine. These results warrant further study in an ejecting model to investigate LV systolic and diastolic mechanics with the oblique method of CT preservation, including interactions with LV systolic twist and diastolic recoil.

Animals↗

Exploring better methods to preserve the chordae tendineae during mitral valve replacement.

BACKGROUND: It is not known how best to resuspend the mitral chordae tendineae during mitral valve replacement to optimize postoperative left ventricular (LV) systolic and diastolic function. METHODS: Six different techniques to preserve the chordae during mitral valve replacement were compared in 12 dogs using a nondistorting isovolumic technique: conventional, all chordae severed; anterior, all chordae preserved anteriorly; partial, anterior papillary muscle chordae preserved anteriorly; posterior, all chordae preserved posteriorly; oblique, anterior papillary muscle chordae directed anteriorly and posterior papillary muscle chordae posteriorly; and counter, opposite of oblique chordal direction. Control measurements (no chordal tension) were recorded between each experimental condition. RESULTS: The oblique method tended to have the best LV systolic function versus the conventional method (Emax = 4.0 +/- 1.8 versus 3.3 +/- 1.2 mm Hg/mL [mean +/- standard deviation]; p = 0.08 by repeated-measures analysis of variance; physiologic intercept Ees100 = 20.3 +/- 8.6 mL [p < 0.05 versus control]), with no major change in LV diastolic stiffness. The posterior method had a lower Emax (3.3 +/- 1.2 mm Hg/mL) than the oblique method, but a similar Ees100 (20.8 +/-8.1 mL; p < 0.05 versus control) and the best diastolic LV performance (LV diastolic stiffness = 0.46 +/- 0.23 mm Hg/mL). The counter method also had good systolic function (Emax = 3.8 +/- 1.2 mm Hg/mL; Ees100 = 19.7 +/- 7.5 mL; p < 0.05 versus control), but had less favorable diastolic properties (0.65 +/- 0.37 mm Hg/mL; p < 0.05 by repeated-measures analysis of variance versus posterior). CONCLUSIONS: In this isovolumic preparation in normal canine hearts, the oblique method of chordal resuspension was associated with the best LV systolic function, whereas the counter technique impaired LV diastolic function. These preliminary results warrant further study in ejecting and failing hearts to determine conclusively which chordal orientation best preserves LV performance after mitral valve replacement.

Animals↗

Inhibition of accelerated cardiac allograft arteriosclerosis by fish oil.

Accelerated coronary arteriosclerosis remains the most important factor limiting long-term survival of heart transplant recipients, and dietary fish oil supplementation with omega-3 polyunsaturated fatty acids has been suggested to have a protective effect against coronary disease in epidemiologic studies and to inhibit arteriosclerosis in animal experiments. Therefore we tested the hypothesis that fish oil administration inhibits the development of allograft coronary arteriosclerosis by using a heterotopic heart transplant model. Three groups of Lewis rats (n = 10 each) received heterotopic heart transplants from Brown-Norway donors and were treated with cyclosporine intraperitoneally on a tapering schedule. Group 1 received fish oil daily by gavage (2 ml/kg/day; Emulsified Super MaxEpa, Twin Labs, Ronkonkona, N.Y.). Group 2 received an equal amount of safflower oil, as well as aspirin (1 mg/kg/day) and dipyridamole (3 mg/kg/day). Group 3 received safflower oil only. All rats were put to death 110 days later, at which time there was no statistically significant difference in graft function as assessed by palpation (scale 0 to 4, mean = 3.7 +/- 0.5 [+/- standard deviation]; analysis of variance: p = 0.72) or in microscopic grade of rejection (scale, 0 = none to 3 = severe, mean 2.1 +/- 0.6; analysis of variance: p = 0.68) between any of the groups. The coronary arteries were histologically scored for the degree of arteriosclerosis (scale, 0 = normal to 3 = occluded), and a mean grade of coronary disease was calculated for each heart. The fish oil-treated group had significantly less severe allograft coronary arteriosclerosis (analysis of variance: p = 0.005) than did groups 2 and 3 (mean grade 0.23 +/- 0.22 versus 1.04 +/- 0.75 and 0.96 +/- 0.55 (p less than 0.05, Scheffe F test), whereas groups 2 and 3 had similar degrees of coronary disease (p = no significant difference). These data demonstrate that fish oil supplementation inhibited accelerated coronary arteriosclerosis in this cyclosporine-treated heart allograft rat model, whereas antiplatelet agents in these doses were ineffective. Although the mechanism of this protective effect remains incompletely understood, it does not appear to involve enhanced immunosuppression. Fish oil and specific omega-3 polyunsaturated fatty acids should be further investigated as potentially useful agents to ameliorate accelerated allograft coronary arteriosclerosis in other animal species and perhaps eventually in man.

Animals↗