Search PubMed⌕ Search

Biomedical subjects

J Potratz

Publications and source records attributed to J Potratz.

32 records · Page 2Linked to original sources

Cardiomyopathic lentiginosis/LEOPARD syndrome presenting as sudden cardiac arrest.

A 26-year-old apparently healthy man with numerous pigmented skin lesions collapsed during an evening party and was resuscitated from ventricular fibrillation. Hypertrophic cardiomyopathy and subaortic tunnel were disclosed by angiocardiography. A diagnosis of cardiomyopathic lentiginosis/lentigines (multiple), electrocardiographic abnormalities, ocular hypertelorism, pulmonary stenosis, abnormalities of the genitalia, retardation of growth, and deafness (sensorineural) syndrome was made. The patient then underwent treatment with an implantable pacer-cardioverter-defibrillator device. Further evaluation revealed several well-established features of the disorder. This is the first reported case of survival from ventricular fibrillation associated with this rare and little known multifaceted syndrome. Disseminated lentiginosis must prompt clinicians to evaluate such cases further since underlying disorders may be associated with considerable morbidity and, apparently, sudden death.

Abnormalities, Multiple↗

Priming of neutrophils after elective percutaneous transluminal coronary angioplasty is unrelated to accompanying brief myocardial ischemia.

OBJECTIVE: The purpose of this study was to investigate the effect of brief myocardial ischemia and vascular trauma induced by elective percutaneous transluminal coronary angioplasty on in vivo 'priming' and activation of neutrophils. PATIENTS AND METHODS: We studied 16 patients undergoing elective coronary angioplasty for symptomatic coronary artery disease and a control group of seven patients undergoing diagnostic cardiac catheterization. Free radical production from purified neutrophils (Ficoll-Hypaque density gradient method) was measured indirectly by the chemiluminescence method. Myocardial ischemia during balloon inflation was assessed by serial lactate determinations from coronary sinus and arterial blood. The degree of transient angioplasty-related myocardial ischemia was related to the oxidative response of activated neutrophils. RESULTS: Mean (+/-S.E.M.) oxidative response, i.e. the lucigenin- and luminol-enhanced-chemiluminescence (counts per minute) of neutrophils sampled from the coronary sinus increased significantly after percutaneous transluminal coronary angioplasty (Lucigenin-chemiluminescence: pre-angioplasty 3.69+/-0.64x10(5) vs. post-angioplasty 7.08+/-1.2x10(5), P<0.01; Luminol-chemiluminescence: pre-angioplasty 2.81+/-0.67x10(6) vs. post-angioplasty 5.2+/-0.92x10(6), P<0.01). Twelve of 16 patients developed transient cardiac lactate production (mean coronary sinus lactate excess: +0.12 mmol/l) and three disclosed a lactate extraction ratio <10%, both suggestive of myocardial ischemia. However, there was no correlation between the cardiac lactate production and the increased oxidative response after coronary angioplasty (r2 (Lucigenin-chemiluminescence)=0.02, n.s.; r2 (Luminol-chemiluminescence)=0.06, n.s.). CONCLUSION: 'Priming' of neutrophils, as reflected by increased oxidative response, is likely to occur after coronary angioplasty, but not after the angiographic procedure itself. However, 'priming' seems to be unrelated to the transient brief period of myocardial ischemia and rather depends on an alternative mechanism.

Adult↗

[Atrial sensing and atrioventricular synchrony in single lead VDD pacemakers. Can the appearance of atrial undersensing be predicted?].

Single-lead VDD-pacing is an alternative to DDD-systems in patients with AV-block and normal sinus node function. Atrial sensing plays a central role in these pacemakers. AV-synchrony, incidence of atrial arrhythmias and the occurrence of sinus node disease were investigated in 108 patients with VDD-pacemakers followed over a mean period of 24.8 months after implantation. Determinants influencing the occurrence of atrial undersensing were especially focused on. Mean atrial potential and sensing threshold were reduced within the first 2 weeks after implantation (p < 0.01). Intermittent atrial undersensing occurred in 25.9% of patients and was observed in 82.1% of these patients within the first 2 weeks after implantation. Positioning the atrial dipole in the low right atrium showed a significantly higher incidence of atrial undersensing (42% in comparison to 24% in the other positions). In a multivariate analysis including intra- and postoperative measurements as well as characteristics of the pacemakers and leads, it was the only parameter significantly (p < 0.02) correlated to the occurrence of atrial undersensing. Atrial fibrillation was observed in 4.6% of patients, a sinus node disease became evident in 2.7% of patients; 92.6% of patients remained in the AV-synchronous mode. Intermittent atrial undersensing is common in single-lead VDD-pacemakers and difficult to provide during implantation. The atrial dipole should not be positioned in the low right atrium and highest atrial sensitivity should generally be programmed. Nevertheless, VDD-pacing achieves an AV-synchrony comparable to DDD-pacemakers.

Aged↗

Impact of early accelerated dose tissue plasminogen activator on in-hospital patency of the infarcted vessel in patients with acute right ventricular infarction.

OBJECTIVE: To assess the efficacy of early accelerated dose tissue plasminogen activator on in-hospital patency of the infarct related artery in patients with inferior myocardial infarction with and without right ventricular involvement. DESIGN: Single centre prospective assessment before discharge of infarct related vessel patency after early thrombolysis. SETTING: Tertiary cardiac referral centre at a university hospital. PATIENTS AND METHODS: 90 consecutive unselected patients with acute myocardial infarction, of whom 35 (39%) had electro-cardiographic evidence of right ventricular involvement (ST segment elevation greater than 0.1 mV in right precordial lead V4R), were studied. All patients received accelerated dose tissue plasminogen activator 100 mg within six hours from the onset of symptoms and had control angiography before discharge. MAIN OUTCOME MEASURES: Infarct related coronary artery patency using the Thrombolysis in Myocardial Infarction (TIMI) grading system before discharge. Incidence of prolonged systemic hypotension, sinus bradycardia, complete atrioventricular block, and ventricular tachyarrhythmia during early hospitalisation. RESULTS: Despite aspirin and bolus heparinisation before thrombolysis and high dose heparinisation thereafter for at least 48 hours the infarct related artery was more likely to be occluded (TIMI 0 or 1 flow) in patients with right ventricular involvement than in those without (69 v 29%, P < 0.001), as shown by control angiography performed a mean of 12.8 days after thrombolysis. These findings may be explained, at least in part, by predominant involvement of the proximal right coronary artery (66 v 31%, P < 0.05) and a low cardiac output syndrome, being indirectly reflected by a high incidence of prolonged hypotension (26 v 7%, P = 0.02), bradycardia (34 v 14%, P = 0.03), and complete atrioventricular block (37 v 5%, P = 0.0001). CONCLUSION: Primary angioplasty should be considered as the treatment of choice in patients with acute inferior infarction with right ventricular involvement because of the high failure rate of thrombolysis.

Coronary Angiography↗

Electrophysiological characteristics of bipolar membrane carbon leads with and without steroid elution compared with a conventional carbon and a steroid-eluting platinum lead.

In a controlled study, the following four bipolar leads with passive fixation were implanted in 46 patients with the Siemens-Multilog-VVI or Sensolog-VVIR-pacemakers: membrane covered activated porous carbon with steroid elution (Siemens 1402 T, 11 patients) and without (Siemens 1403 T, 15 patients); activated carbon (Siemens 1010 T, 10 patients); and platinum with steroid elution (Medtronic Cap-Sure 5026, 10 patients). Stimulation threshold (STH) (assessed by a vario-test), impedance (IMP), and the intracardial R wave potential (IRW) (both gauged by a telemetric method) were measured 1, 5, and 10 days as well as 3 and 6 months after implantation during unipolar and bipolar stimulation, chronaxie rheobase product (CRP) and energy consumption (EC) were systematically determined. Differing insignificantly at the first day after implantation, STH is significantly lower for the 1402 T and CapSure 5026 leads at the tenth day. However, the 1402 T lead shows a significant increase of STH in the follow-up, in contrast to the other leads. The lowest chronic STH was found in the CapSure 5026 lead (CRP is significantly lower in all other leads, too). IMP is significantly lower in the CapSure 5026 lead compared to 1010 T lead. EC does not differ significantly during chronic stimulation in spite of the best possible programming of pulse amplitude and duration. No significant changes of IRW were observed. Unipolar versus bipolar stimulation shows significantly lower STH, CRP, and IMP, differences of EC and IRW were insignificant. In conclusion, the addition of steroid in membrane covered carbon leads protracts the increase of STH, but does not prevent it. The CapSure 5026 lead shows advantageous stimulation characteristics, but energy consumption is not significantly reduced because of low impedance and impossibility of programming an appropriate low output in Multilog pacemakers.

Aged↗

Accelerated ST-segment reduction after thrombolytic therapy with recombinant tissue plasminogen activator (rtPA) compared to urokinase.

Effects of therapy with urokinase (UK) and with recombinant tissue plasminogen activator (rtPA) were compared in patients with acute myocardial infarction (AMI). To achieve homogenous therapeutic conditions the comparison was restricted to patients having their first AMI and to cases of clinically successful thrombolytic therapy (defined by non-invasive criteria, such as a 50% decrease in elevated ST-segment in the worst load of a 12 lead ECG within 300 min after onset of thrombolytic therapy, complete pain resolution during thrombolytic therapy, and later confirmed by angiography 10 days after AMI). Effects of UK and rtPA on continuous multilead ST-segment analysis and cardiac proteins (creatine kinase and its isoenzyme CK-MB, aspartate transaminase and hydroxybutyrate dehydrogenase) were analyzed during 24 hours following onset of therapy. Continuous ST analysis showed a faster resolution of the elevated ST-segments after thrombolytic therapy with rtPA than with UK(p < 0.01). Accelerated idioventricular rhythms (p < 0.05) occurred sooner following rtPA than UK treatment. The wash-out of creatine kinase was increased (p < 0.01) after rtPA. Although both drugs induced comparable, angiographically controlled reperfusion, the results suggest that the process of reperfusion was accelerated during thrombolysis with rtPA compared to UK. Thrombolytic therapy of AMI with rtPA may hence improve myocardial salvage.

Adult↗

[Detection of stress-induced myocardial ischemia in isolated coronary ectasia and aneurysm (dilatative coronaropathy)].

Forty eight patients with bilateral isolated non-stenotic coronary artery ectasia or aneurysm without associated cardiac defects ("dilated coronaropathy") were identified in consecutive diagnostic cardiac catheterizations between 1986-6/1994 (angiographic incidence 0.44%). Ectasia was defined as a luminal dilatation of the 1.5-2-fold, aneurysm of more than double the normal limits. In 16 patients a myocardial infarction (5 non-q-infarctions/11 q-wave-infarctions) was the indication for coronary angiography, a thrombotic occlusion of the infarct vessel was documented in 8/16 patients. In patients without myocardial infarction (study group) an evaluation of exercise-induced myocardial ischemia was performed by means of a coronary sinus lactate study, treadmill ergometry and Thallium-201-scintigraphy. A corresponding coronary insufficiency was objective in all tests in the study group. An exercise-induced myocardial ischemia was found in 21/31 in the coronary sinus study, 19/29 in the treadmill ergometry and 13/26 patients in the scintigraphy; significant differences were found in comparison to the results of a control group of patients without heart disease (n = 29, p < 0.001). After administration of 0.8 mg nitroglycerin (NTG) a further significant deterioration of myocardial ischemia was measured in the 21 patients with pathologic lactate metabolism developing a frank cardiac lactate production (p < 0.03). The extent of myocardial ischemia in the coronary sinus study was significantly correlated to the coronary diameters of the proximal and middle segments of the Ramus interventricularis anterior and the middle segment of the Ramus circumflexus (r = 0.87, p < 0.02). A differentiation between ectasia and aneurysm therefore seems to be of functional relevance. Angiographic stigmata of an impaired coronary blood flow such as a segmental to and from movement and a local deposition of dye were found significantly more often with increasing coronary diameters (p < 0.04). "Dilated coronaropathy" is an entity of non-stenotic, ischemic coronary artery disease. NTG was of no therapeutic benefit or led to an aggravation of the exercise-induced myocardial ischemia. Because of this potential adverse effect the administration of NTG should be avoided in "dilated coronaropathy".

Adult↗

Adverse pacemaker hemodynamics evaluated by pulmonary venous flow monitoring.

The pacemaker syndrome refers to symptoms and signs in the pacemaker patient caused by an inadequate timing of atrial and ventricular contractions. The lack of normal atrioventricular synchrony may result in a decreased cardiac output and venous cannon A waves. The objective of this study was to define the left atrial and pulmonary venous flow response to ventricular pacing in a group of 14 unselected consecutive patients with total heart block and sinus rhythm. Pulmonary venous flow was assessed by transesophageal pulsed Doppler echocardiography in the VVI and DDD pacing modes. An inappropriate atrial timing caused a marked augmentation of the normally small pulmonary venous z wave in all patients ("negative atrial kick," peak z wave in DDD pacing 14.5 +/- 4.6 cm/s, VVI pacing 51.8 +/- 15.0 cm/s). Restoration of AV synchrony (DDD pacing, AV interval 100 ms) abolished these "cannon z waves" in all patients, and a normal pattern of pulmonary venous flow was achieved. Abnormal pulmonary venous flow characteristics were observed in 2 of 14 patients during DDD pacing with short AV intervals (100 ms). The Doppler pattern was similar to the findings seen in VVI pacing. Assessment of pulmonary venous flow by transesophageal pulsed Doppler echocardiography may provide a simple, sensitive, and relatively noninvasive technique to evaluate patients with suspected pacing induced adverse hemodynamics.

Aged↗

[Determinants of arterial embolism with special reference to atheromatous changes of the thoracic aorta].

Potential sources of arterial embolism were evaluated with special emphasis on aortic atheromatosis in patients who underwent transesophageal echocardiography for various clinical reasons. Among 375 patients, 166 had suffered from cerebrovascular disease or peripheral embolism and 209 were free from symptoms of embolism. Univariate analysis revealed that atheromatosis of the aortic arch and descending aorta as well as cardiac thrombi, aneurysms of the interatrial septum and arterial hypertension were significantly more common in patients who had a history of embolism or ischemic stroke. In a stepwise multiple regression analysis, aortic arch atheromatosis (odds ratio 1.7, 95% CI 1.1-2.6), cardiac thrombi (odds ratio 4.1, 95% CI 1.7-9.8), atrial septal aneurysm (odds ratio 3.0, 95% CI 1.2-7.8) and arterial hypertension (odds ratio 1.8, 95% CI 1.1-3.0) were determined as independent predictors of embolic symptoms. We conclude that atheromatous lesions of the aortic arch are an independent risk factor for arterial embolism and ischemic stroke among other well known sources of embolism.

Aged↗

[Bilateral coronary-pulmonary artery fistula and accessory vascular connection of the thoracic aorta to the right lower pulmonary artery].

A 41-year-old man presenting with atypical chest pain was admitted to hospital with suspected pericarditis after a common cold disease. A complex risk profile for arteriosclerotic coronary artery disease was taken into account in differential diagnosis. Cardiac catheterization revealed large bilateral coronary artery-pulmonary artery fistulas as well as an accessory vessel with origin of the thoracic aorta both draining into the lower right pulmonary artery. The vessel anomalies showed a remarkable plexus-like morphology before entering into the pulmonary artery. Arteriosclerotic coronary artery disease was not found. No evidence of myocardial ischemia was found in the furthermore asymptomatic patient, therefore surgical correction of the vessel anomalies was not performed. To our knowledge the present case report represents the first case with bilateral coronary artery-pulmonary artery fistulas and an accessory communication of the thoracic aorta to the pulmonary artery vasculature.

Adult↗

[Pacemaker syndrome with AV-synchronized stimulation of the heart].

Characteristic signs of the pacemaker syndrome occurred in a 69-year-old woman with intermittent 3 degrees atrioventricular (AV) block after implantation of a dual-chamber AV-synchronized pacemaker. Cannon beats due to inappropriate atrial timing were the main haemodynamic finding. Their development and size depended on the programmed AV interval and AV-synchronized mode of stimulation. Very long AV intervals in the DDD mode at a heart rate of 100/min caused very unpleasant palpitations and pulsations in the upper thorax. The symptoms due to the cannon beats were avoided by changing to a short AV interval. The clinical and haemodynamic events were thus the consequence of preserved sinus node function with subsequent atrial triggering.

Aged↗

[Doppler echocardiographic demonstration of ventricular septum rupture in acute myocardial infarct in an intensive care unit].

Rupture of the ventricular septum after acute transmural myocardial infarction occurred in four patients aged between 53 and 79 years. The rupture was verified by means of right-side cardiac catheterization. Only in two cases did two-dimensional echocardiography reveal the rupture; in both cases the rupture site located by echocardiography was confirmed at autopsy. In each of the four patients the left-to-right shunt could be identified by means of pulsed Doppler echocardiography which showed a turbulence in the right ventricle. Furthermore, the combination of two-dimensional echocardiography and Doppler echocardiography allowed a correct localization of the turbulent left-to-right flow in all cases. In view of these findings, the combination of Doppler echocardiography and two-dimensional echocardiography may be regarded as a suitable method for a readily available, non-invasive diagnosis of ventricular septum rupture in patients with acute myocardial infarction in an intensive care unit.

Aged↗

[Right ventricular intracardial recordings of late potentials in patients with acute myocardial infarction and recurrent ventricular tachycardias].

The role of delayed potentials in ventricular arrhythmias occurring in connection with acute myocardial infarction has been of increasing interest in recent years. In order to obtain further information about delayed electrical activity, we studied a group of 51 patients in the acute phase of myocardial infarction, and intracardiac recordings were made using bipolar electrodes. In 31 of the 51 patients we recorded delayed potentials 150-200 ms after the beginning of QRS. 14 patients showed delayed electrical activity in diastole even after the T wave. The same potentials as those obtained by intracardiac recording techniques were also recorded from the body surface using a signal-averaging technique. In several cases we were able to show that these delayed potentials initiated premature ventricular beats. In 1 patient a sustained ventricular tachycardia induced by delayed potentials was recorded. We found that delayed potentials could be abolished by antiarrhythmic drugs. There thus appears to be an important relationship between delayed electrical activity and the occurrence of ventricular arrhythmias.

Acute Disease↗

[Recent aspects of cardiologic therapy in advanced age].

The aging heart differs in several aspects from the heart in younger people: Cardiac muscle mass, systolic and diastolic wall stress increase, the velocity of electrical conduction decreases in different anatomical structures. Supraventricular and ventricular arrhythmias appear more frequently than in younger people. Heart rate and cardiac index tend to diminish, especially under work load. Work capacity is reduced. In the treatment of coronary heart disease drugs are preferred which lead to a reduction of preload. Nitrates and molsidomine are followed by calcium channel blockers and--afterwards--by beta-blockers. Bypass surgery is performed in elderly patients more often for therapeutical than for prognostic reasons, similarly in the case of valvular surgery. Typical tachyarrhythmias are treated only in case of hemodynamic relevance, whereas pacemaker therapy is not limited by greater age. The choice of the most suitable pacemaker model, however, has to be based upon the overall circumstances in each individual case. For the treatment of congestive heart failure, vasodilators, especially angiotensin-converting enzyme inhibitors, seem to be superior, in elderly patients, to diuretics and digitalis glycosides.

Aged↗