Search PubMed⌕ Search

Biomedical subjects

J Pincemail

Publications and source records attributed to J Pincemail.

At least 19 recordsLinked to original sources

Levels of inflammatory markers in the blood processed by autotransfusion devices during cardiac surgery associated with cardiopulmonary bypass circuit.

Intraoperative blood salvage devices allowing a reinfusion of red blood cells (RBCs) after processing of shed blood and stagnant blood in the mediastinal cavity are more and more used to reduce homologous blood requirements in cardiac surgery with cardiopulmonary bypass (CPB). As the proinflammatory activity of the shed blood also contributes to morbidity during CPB, we conducted a prospective study in order to examine the quality of autologous blood before and after processing with five different devices [BRAT2, Sequestra, Compact Advanced, Cell Saver 5 (CS5), Continuous Autologous Transfusion System (CATS)]. All systems resulted in an excellent haemoconcentration, ranging from 53.7% (Compact) to 68.9% (CATS). The concentrations and elimination rates of several inflammatory markers [IL-1beta, IL-2, IL-8, TNFalpha, myeloperoxidase (MPO), elastase] were examined. Except for the Sequestra, an important increase in concentration of IL-1beta (between 30% and 220%) has been observed after processing with each device. In contrast, the attenuation rate of IL-6 and TNFalpha (95%) was optimal for all investigated blood salvages systems. Regarding IL-8, only the CATS and CS5 systems were able to attenuate this biological parameter with an excellent efficacy. The rate of attenuation in MPO and elastase, as markers of leukocyte activation, was higher than 80% for all devices. In conclusion, the different RBC washing systems tested in this study resulted in a significant attenuation of the inflammatory response. Increased levels of IL-1beta after processing remained, however, unclear. According to the type of protocol, based on inlet haematocrit, fill and wash speeds, and wash volumes, small variations in reducing the inflammatory response have been observed from one device to another.

Aged↗

Evaluation of autoantibodies against oxidized LDL and antioxidant status in top soccer and basketball players after 4 months of competition.

Antioxidant status and titers of autoantibodies against oxidized low-density lipoproteins (ox-LDL-Ab) were investigated in top soccer (S; n = 21, age 24.6 +/- 4.3 years) and basketball (B; n 3,000 mIU/ml) in ox-LDL-Ab were found in half the players (12S and 4B) with a maximum reaching 6000 mIU/ml (normal range: 200-600 mIU/ml), showing an in vivo LDL oxidation. There was no correlation between ox-LDL-Ab titers and chlolesterol, LDL cholesterol, or antioxidant levels. Nevertheless, plasma vitamin C concentration was lower in athletes having high levels of ox-LDL-Ab when compared with those with normal levels (8.49 +/- 3.14 mirogram/ml vs. 10.39 +/- 2.55 microgram/ml), but this difference was not statistically significant. In conclusion, our data suggest that potential atherogenic and cardiovascular risks as reflected by high titers in ox-LDL-Ab may exist in some top athletes despite a nonaltered antioxidant status.

Adult↗

Cytokine release and neutrophil activation are not prevented by heparin-coated circuits and aprotinin administration.

BACKGROUND: Cardiopulmonary bypass (CPB) initiates a whole-body inflammatory response where complement and neutrophil activation and cytokine release play an important role. This prospective trial examined the effects of both heparin-coated circuits and aprotinin on the inflammatory processes during CPB, with respect to cytokine release and neutrophil activation. METHODS: Two hundred patients undergoing cardiac surgery were randomized in four groups of 50 patients each: heparin-coated circuit with aprotinin (HCO-A) or without aprotinin (HCO) administration, and uncoated circuit with aprotinin (C-A) or without aprotinin administration (C). In groups receiving aprotinin, a high-dose regimen was given. In all groups, high initial doses of heparin were used (3 mg/kg intravenously). Tumor necrosis factor-alpha (TNF-alpha), interleukin-6 (IL-6) and IL-8, and myeloperoxidase and elastase levels were measured in plasma samples taken before, during, and after CPB. RESULTS: In all groups, the TNF-alpha, IL-6, and IL-8 levels reached a maximum after protamine administration. After 24 hours, they remained significantly elevated (IL-6 and IL-8) or returned to baseline values (TNF-alpha). A similar pattern was observed with myeloperoxidase and elastase levels. No significant intergroup differences were observed. CONCLUSIONS: CPB is associated with cytokine release and neutrophil activation, which are not attenuated by the use of heparin-coated circuits or by the administration of aprotinin. Aprotinin and heparin-coated circuits do not show additive effects.

Aprotinin↗

SMA circuits reduce platelet consumption and platelet factor release during cardiac surgery.

BACKGROUND: Platelet count and function are particularly damaged by cardiopulmonary bypass (CPB). This study evaluated the effects of a novel CPB circuit in terms of platelet count and activation, and postoperative need for blood products. METHODS: One hundred patients undergoing coronary grafting were randomized in two groups: control group (n = 50) and test group (n = 50, surface modifying additives circuit, SMA group). Blood samples were taken before, during, and after CPB. Postoperative blood loss, number of transfused blood products, and postoperative variables were recorded. RESULTS: The platelet count decreased less in the SMA group compared to the control group (end of CPB: respectively, 165 +/- 9 x 10(3)/mm3 vs 137 +/- 8 x 10(3)/mm3; p < 0.01). This was paralleled by a reduction in beta-thromboglobulin plasma levels in the SMA group. There was a trend to decreased blood loss in the SMA group, but the difference was significant only in patients taking aspirin preoperatively (p < 0.05). In the SMA group nearly 50% less fresh frozen plasma and platelet units were administered (p < 0.01). No operative deaths were observed. CONCLUSIONS: The use of circuits with surface additives is clinically safe, preserves platelet levels, and attenuates platelet activation. This may lead to a reduced need for blood products.

Adult↗

Comparative effects of University of Wisconsin and Euro-Collins solutions on pulmonary mitochondrial function after ischemia and reperfusion.

BACKGROUND: The aim of this study was to compare the effects of Euro-Collins and University of Wisconsin solutions on pulmonary mitochondrial function after cold ischemia and subsequent warm reperfusion. METHODS: Seventeen pigs underwent lung harvesting after classical lung flush with either University of Wisconsin or Euro-Collins solutions. The mitochondria were isolated from fresh swine lungs, from swine lungs subjected to 24 hr of cold ischemia, and from swine lungs subjected to 24 hr of ischemia followed by 30 min of subsequent ex vivo reperfusion at 37 degrees C with Krebs-Henseleit buffer solution and air ventilation. Mitochondrial oxidative phosphorylation parameters were determined in isolated mitochondria by in vitro measurement of oxygen consumption rates. During reperfusion, the lung function was assessed by the pulmonary aerodynamic parameters and the pulmonary vascular resistance. RESULTS: Relative to controls, mitochondria submitted to cold ischemia showed an alteration in the oxidoreductase activities of the respiratory chain. However, the yield of oxidative phosphorylation was conserved. After reperfusion, pulmonary mitochondria underwent a significant worsening in the oxidoreductase activities of the respiratory chain, and a decrease in the respiratory control and the efficiency of oxidative phosphorylation. Meanwhile, the reperfused lungs showed evidence of early dysfunction, assessed by the aerodynamic parameters and pulmonary vascular resistance. In this model, there was no advantage of University of Wisconsin solution over Euro-Collins solution. CONCLUSIONS: The mild mitochondrial alterations after cold ischemia were not sufficient to explain the limited tolerance of lung to ischemia. After reperfusion, the mitochondrial damage was more severe and could be involved in the posttransplant lung dysfunction.

Adenosine↗

Local and systemic consequences of severe ischemia and reperfusion of the skeletal muscle. Physiopathology and prevention.

Revascularization of a limb after a severe and prolonged period of ischemia may be associated with high rates of mortality and amputation, because of the development of a postrevascularization syndrome, regardless the cause of occlusion (ischemia, trauma, iatrogenic) or the methods used to achieve reperfusion (fibrinolysis, surgery, resuscitative therapy). This "revascularization" syndrome includes several complications, both local (explosive swelling of the limb, compartment syndrome and skeletal muscle infarction (rhabdomyolysis) and general (acidosis, hypercalcemia, hypovolaemic shock, renal, hepatointestinal and pulmonary failures, arrhythmias and cardiac arrest (multiple organ dysfunction). Current therapies are directed against complications after they occurred, once revascularization is completed: fasciotomy, mannitol and diuretics administration for forced diuresis, fluid administration to correct hypovolaemia, use of resins, insulin and glucose or haemodialysis to deal with hypercalcemia, administration of buffers (THAM, bicarbonate) to correct acidosis, control of hypercalcaemia with orthophosphates and calcitonin.... Nevertheless, a substantial percentage of the injury is generated upon reperfusion and the muscle may remain viable after prolonged period of ischemia. Intra and extraacellular swelling, tissue acidosis, free radical mediated damage, loss of adenine nucleotide precursors, and intracellular calcium overload have been suggested to be the mechanisms responsible for reperfusion injury. Careful control of both the composition and the physical conditions of the initial reperfusion (controlled reperfusion) may result, in selected cases, in improvements in the metabolism, structure and function of the limb after reperfusion.

Acute Kidney Injury↗

Successful controlled limb reperfusion after severe prolonged ischemia.

Controlled limb reperfusion was performed in two patients who were admitted for lower limb-threatening ischemia as a result of embolism. After embolectomy, the inflow blood was drained with a cannula and mixed with a crystalloid solution to obtain an hyperosmolar, hypocalcemic, alkalotic, and substrate-enriched (aspartate, glutamate) reperfusate. This reperfusate was reinjected with a roller pump for 30 minutes through two cannulas inserted in the profunda and superficial femoral arteries. Temperature, intraarterial pressures, and flow were closely controlled. No complications occurred, and complete recovery of motor and sensory functions were observed, with restoration of pedal pulses.

Aged↗

Peroxidase-catalysed oxidation of different dibenzazepine derivatives.

According to a recent hypothesis suggesting the potential role of free radical formation in the clozapine-induced agranulocytosis, we have evaluated the susceptibility to the peroxidase-mediated oxidation of different dibenzazepine analogues. On the one hand, compounds with an arylamine group such as clozapine or isoclozapine present a high reactivity in the horseradish peroxidase or myeloperoxidase systems and, on the other hand, fluperlapine, though known to induce agranulocytosis, and other dibenzothiazepine and dibenzoxazepine derivatives appear insensitive to oxidation. Consequently, among tricyclic derivatives, the way of diaryloxa- and diarylthiazepine compounds could be an alternative for the development of safer drugs such as antipsychotics.

Catalysis↗

Diaspirin crosslinked hemoglobin (DCLHb): absence of increased free radical generation following administration in a rabbit model of renal ischemia and reperfusion.

In control rabbits, a renal ischemia of 60 min followed by 10 min of reperfusion resulted in an enhanced free radical production in cortical tissue, as assessed by a significant decrease of free glutathione (42%), protein-bound GSH (17%), and vitamin E (49%). In contrast, catalase or glutathione peroxidase activities were not affected by these experimental conditions. Free radical production in this model was also measured directly using electron spin resonance (ESR) spectroscopy associated with a PBN (alpha-phenyl N-tert-butyl-nitrone) spin trap agent in the venous blood arising from the ischemic kidney. The signal consisted of a triplet of doublets. In contrast, no signal could be detected in control blood samples taken prior to inducing ischemia. The burst of free radical production occurred in the early phase after restoration of flow in the kidneys rendered ischemic, as evidenced by a signal of weak intensity which generally appeared within the third minute after reperfusion and progressively increased to form a well-defined asymmetric signal following 10 min of reperfusion. The precise nature of free radicals trapped by the PBN agent remains, however, to be elucidated, but analysis of the coupling constants (aN = 14.5-15 G; a beta H = 2.5-3 G) and asymmetry of the central doublets suggests that the ESR signal may arise from a nitorxy-radical adduct resulting from the spin trapping by PBN of both oxygen- or carbon-centered radicals of lipid origin. As evidenced by both direct and indirect measurements, exchange of rabbit blood immediately after inducing renal ischemia with 30 ml/kg of Diaspirin Crosslinked Hemoglobin (7.5 g/dl in lactated electrolyte) or human serum albumin (7.5 g/dl in lactated electrolyte) did not exacerbate free radical production mediated by an ischemia reperfusion phenomenon, a typical situation found in a resuscitation setting.

Animals↗