[Coronarography].

Explore the source record for details and available documents.

Cardiac Catheterization↗

Biocompatibility of biodegradable and nonbiodegradable polymer-coated stents implanted in porcine peripheral arteries.

PURPOSE: To investigate the neointimal response to poly(organo)phosphazene- and amphiphilic polyurethane-coated, oversized, stainless steel stents implanted in porcine peripheral arteries. METHODS: Nonarticulated, stainless steel, slotted-tube stents were coated with 1) a biodegradable poly-(organo)phosphazene with aminoacid ester side groups and 2) a biostable polyurethane prepared from an amphiphilic polyether, diphenyl methane-4,4'-diisocyanate and butane diol as chain extender. The stents were deployed in porcine peripheral arteries using an oversized balloon. RESULTS: The neonintimal response to amphiphilic polyurethane-coated stents was similar to the uncoated metallic stents. Poly(organo)phosphazene-coated stents, however, induced a severe histiolymphocytic and fibromuscular reaction resembling a foreign body reaction. CONCLUSIONS: Amphiphilic polyurethane is very promising as a biocompatible stent coating. Poly-(organo)phosphazene, however, appears unsuitable for this purpose.

Angioplasty, Balloon↗

Comparison of self-expanding polyethylene terephthalate and metallic stents implanted in porcine iliac arteries.

PURPOSE: Comparison of the biocompatibility of self-expanding polyethylene terephthalate (PET) stents with self-expanding metallic stents (Wallstents). METHODS: Diameter- and length-matched PET stents and Wallstents were symmetrically implanted in the paired iliac arteries of 13 crossbred domestic swine. Stent deployment was studied angiographically and with intravascular ultrasound immediately after stent implantation. The angiographic stented lumen diameter was measured using quantitative vessel analysis before, immediately after stenting, and at 6-week follow-up. Cross-section histopathology and area morphometry were performed. RESULTS: Immediately poststenting, intravascular ultrasound revealed proximal dislocation of 5 of the 13 PET stents, whereas all metal stents were firmly embedded at the implantation site. At 6-week follow-up, three of the remaining PET stents were totally or subtotally occluded by organized thrombus, whereas all metal stents were patent. Compared with immediately poststenting, the angiographic lumen diameter within the five remaining PET stents was reduced by 30%, and that of the metallic stents was virtually unaltered (p < 0.02). This observation was confirmed by postmortem morphometry, wherein the PET-stented vessel segments a diameter stenosis of 40% was measured vs only 9% in the metallic stents (p < 0.0001). CONCLUSION: PET-stent deployment is difficult to control due to the lack of radiopacity of this stent. PET stents seem to be more thrombogenic and lead to significantly more neointimal proliferation than metallic stents.

Animals↗