Search PubMed⌕ Search

Biomedical subjects

J P Wikswo

Publications and source records attributed to J P Wikswo.

At least 19 recordsLinked to original sources

Engineering challenges of BioNEMS: the integration of microfluidics, micro- and nanodevices, models and external control for systems biology.

Systems biology, i.e. quantitative, postgenomic, postproteomic, dynamic, multiscale physiology, addresses in an integrative, quantitative manner the shockwave of genetic and proteomic information using computer models that may eventually have 10(6) dynamic variables with non-linear interactions. Historically, single biological measurements are made over minutes, suggesting the challenge of specifying 10(6) model parameters. Except for fluorescence and micro-electrode recordings, most cellular measurements have inadequate bandwidth to discern the time course of critical intracellular biochemical events. Micro-array expression profiles of thousands of genes cannot determine quantitative dynamic cellular signalling and metabolic variables. Major gaps must be bridged between the computational vision and experimental reality. The analysis of cellular signalling dynamics and control requires, first, micro- and nano-instruments that measure simultaneously multiple extracellular and intracellular variables with sufficient bandwidth; secondly, the ability to open existing internal control and signalling loops; thirdly, external BioMEMS micro-actuators that provide high bandwidth feedback and externally addressable intracellular nano-actuators; and, fourthly, real-time, closed-loop, single-cell control algorithms. The unravelling of the nested and coupled nature of cellular control loops requires simultaneous recording of multiple single-cell signatures. Externally controlled nano-actuators, needed to effect changes in the biochemical, mechanical and electrical environment both outside and inside the cell, will provide a major impetus for nanoscience.

Animals↗

Vector projection of biomagnetic fields.

Biomagnetic measurements are increasingly popular as functional imaging techniques for the non-invasive assessment of electrically active tissue. Although most currently available magnetometers utilise only one component of the vector magnetic field, some studies have suggested the possibility of obtaining additional information from recordings of the full magnetic field vector. Three projection techniques were applied to different biomagnetic signals for analysis of the three orthogonal components of the vector magnetic field. Vector magnetic fields obtained from fetal cardiac activity were projected into evenly spaced directions around a unit sphere. The vector magnetic field recorded from multiple intestinal current sources with independent temporal frequencies was then projected. Finally, an external reference signal from an invasive electrode was used to project the recorded vector magnetic fields due to gastric electrical activity. In each case, it was found that the information obtained by examination of the projected magnetic field vectors gave superior clinical insight to that obtained by analysis of any single magnetic field component.

Animals↗

Biomagnetic detection of gastric electrical activity in normal and vagotomized rabbits.

We recorded the vector magnetogastrogram (MGG) due to gastric electrical activity (GEA) in normal rabbits using a Superconducting QUantum Interference Device (SQUID) magnetometer and measured the degree of correlation of the MGG with 24 channels of serosal electrodes. The vector magnetometer allows us to non-invasively record three orthogonal magnetic field components and project the recorded magnetic field vector into arbitrary directions. We optimized the magnetic field vector direction to obtain the highest possible correlation with each serosal electrode recording. We performed a vagotomy and examined spatial and temporal changes in the serosal potential and in the transabdominal magnetic field. We obtained spatial information by mapping the recorded signals to the electrode positions in the gastric musculature. Temporal evidence of uncoupling was observed in spectral analyses of both serosal electrode and SQUID magnetometer recordings. We conclude that non-invasive recordings of the vector magnetogastrogram reflect underlying serosal potentials as well as pathophysiological changes following vagotomy.

Animals↗

The effects of tubulin-binding agents on stretch-induced ventricular arrhythmias.

Stretch-activated ion channels have been identified as transducers of mechanoelectric coupling in the heart, where they may play a role in arrhythmogenesis. The role of the cytoskeleton in ion channel control has been a topic of recent study and the transmission of mechanical stresses to stretch-activated channels by cytoskeletal attachment has been hypothesized. We studied the arrhythmogenic effects of stretch in 16 Langendorff-perfused rabbit hearts in which we pharmacologically manipulated the microtubular network of the cardiac myocytes. Group 1 (n=5) was treated with colchicine, which depolymerizes microtubules, and Group 2 (n=6) was treated with taxol, which polymerizes microtubules. Stretch-induced arrhythmias were produced by transiently increasing the volume of a fluid-filled left ventricular balloon with a volume pump driven by a computer-controlled stepper motor. Electrical events were recorded by a contact electrode which provided high-fidelity recordings of monophasic action potentials and stretch-induced depolarizations. The probability of eliciting a stretch-induced arrhythmia increased (0.22+/-0.11 to 0.62+/-0.19, p=0.001) in hearts treated with taxol (5 microM), whereas hearts treated with colchicine (100 microM) showed no statistically significant change. We conclude that proliferation of microtubules increased the arrhythmogenic effect of transient left ventricle diastolic stretch. This result indicates a possible mode of arrhythmogenesis in chemotherapeutic patients and patients exhibiting uncompensated ventricular hypertrophy. The data would indicate that the cytoskeleton represents a possible target for antiarrhythmic therapies.

Animals↗

Volume conductor effects on the spatial resolution of magnetic fields and electric potentials from gastrointestinal electrical activity.

An analysis of the relative capabilities of methods for magnetic and electric detection of gastrointestinal electrical activity is presented. The model employed is the first volume conductor model for magnetic fields from GEA to appear in the literature. A mathematical model is introduced for the electric potential and magnetic field from intestinal electrical activity in terms of the spatial filters that relate the bioelectric sources with the external magnetic fields and potentials. The forward spatial filters are low-pass functions of spatial frequency, so more superficial external fields and potentials contain less spatial information than fields and potentials near the source. Inverse spatial filters, which are reciprocals of the forward filters, are high-pass functions and must be regularised by windowing. Because of the conductivity discontinuities introduced by low-conductivity fat layers in the abdomen, the electric potentials recorded outside these layers required more regularisation than the magnetic fields, and thus, the spatial resolution of the magnetic fields from intestinal electrical activity is higher than the spatial resolution of the external potentials. In this study, two smooth muscle sources separated by 5cm were adequately resolved magnetically, but not resolved electrically. Thus, sources are more accurately localized and imaged using magnetic measurements than using measurements of electric potential.

Digestive System↗

Experimental and theoretical analysis of phase singularity dynamics in cardiac tissue.

INTRODUCTION: Quantitative analysis of complex self-excitatory wave patterns, such as cardiac fibrillation and other high-order reentry, requires the development of new tools for identifying and tracking the most important features of the activation, such as phase singularities. METHODS AND RESULTS: Image processing operations can be used to detect the phase singularity at the tip of a spiral wave. The phase space behavior of a spatiotemporal sequence of data may be reconstructed using time-series analysis. The phase singularities then are localized efficiently by computing the topologic charge density as the curl of the spatial phase gradient. We analyzed the singularity interaction dynamics of both experimentally observed and numerically simulated instances of quatrefoil reentry and found that the singularity behavior in the experimental preparations can be classified into three categories on the basis of how their separation changes with time. CONCLUSION: Topologic charge densities can be calculated easily and efficiently to reveal phase singularity behavior. However, the differences between theoretical and experimental observations of singularity separation distances indicate the need for more sophisticated numerical models.

Action Potentials↗

Spatial filter approach for comparison of the forward and inverse problems of electroencephalography and magnetoencephalography.

We present an analysis of the relative information content of cortical current source reconstructions from electroencephalogram (EEG) and magnetoencephalogram (MEG) forward calculations by examining the spatial filters that relate the internal sources with the externally measured electric potentials and magnetic fields. The forward spatial filters are seen to be low-pass functions of spatial frequency and spatial resolution degrades in external measurements. Inverse spatial filters may be used to reconstruct cortical sources from external data, but since they are high-pass functions of spatial frequency, they must be regularized to avoid instabilities caused by noise at higher spatial frequencies. The regularization process limits the spatial resolution of source reconstructions. EEG forward spatial filters fall off at lower spatial frequencies than MEG filters; hence, there is less information available in higher spatial frequencies resulting in lower spatial resolution in inverse reconstructions. The tangential component of the magnetic field provides even higher spatial resolution than can be obtained using the radial component. An accompanying article examines the surface Laplacian for both the EEG and the MEG.

Electric Conductivity↗

Spatial filter approach for evaluation of the surface Laplacian of the electroencephalogram and magnetoencephalogram.

The surface Laplacian is a technique that has been utilized to improve the spatial resolution of the electroencephalogram (EEG) and the magnetoencephalogram (MEG). We investigate the amount of improvement to the spatial resolution afforded by the surface Laplacian by examining the spatial filters that describe the relationship between cortical current sources and the surface Laplacian. The surface Laplacian spatial filters extend into higher spatial frequencies than do raw signal spatial filters, particularly for EEG Laplacian spatial filters, indicating that substantial improvement in spatial resolution is possible. However, the response of the surface Laplacian operation to the nature and amount of noise in the raw EEG and MEG signals is of paramount importance. Spatially correlated noise, coupled with uncorrelated noise, requires additional regularization of inverse spatial filters resulting in a decrease in spatial resolution. Substantial improvements in spatial resolution may be obtained using the surface Laplacian techniques as long as correlated noise levels are small and raw signals have relatively high signal-to-noise ratios.

Computer Simulation↗

A low temperature transfer of ALH84001 from Mars to Earth.

The ejection of material from Mars is thought to be caused by large impacts that would heat much of the ejecta to high temperatures. Images of the magnetic field of martian meteorite ALH84001 reveal a spatially heterogeneous pattern of magnetization associated with fractures and rock fragments. Heating the meteorite to 40 degrees C reduces the intensity of some magnetic features, indicating that the interior of the rock has not been above this temperature since before its ejection from the surface of Mars. Because this temperature cannot sterilize most bacteria or eukarya, these data support the hypothesis that meteorites could transfer life between planets in the solar system.

Crystallization↗

A simple nonlinear model of electrical activity in the intestine.

We have simulated electrical activity of the intestine in a computer model that describes the coupled layers of longitudinal muscle (LM) and interstitial cells of Cajal (ICC). The model suggests that pacemaker activity is due to the ICC layer, while the pulse propagation involves the LM layer that is in the excitatory state. The model describes well the experimentally observed phenomena: frequency change along the intestine, synchronization along short distances and desynchronization for long distances, and the decrease of propagation distance and propagation time along the intestine. We have observed the occurrence of phase interruptions or breaks, which are responsible for the limited values of propagation distance and time.

Biological Clocks↗

Three-dimensional surface reconstruction and fluorescent visualization of cardiac activation.

Optical imaging of transmembrane potentials in cardiac tissue is a rapidly growing technique in cardiac electrophysiology. Traditional studies typically use a monocular imaging setup, thus limiting investigation to a restricted region of tissue. However, studies of large-scale wavefront dynamics, especially those during fibrillation and defibrillation, would benefit from visualization of the entire epicardial surface. To solve this problem, a panoramic cardiac visualization algorithm was developed which performs the two tasks of reconstruction of the surface geometry of the heart, and representation of the panoramic fluorescence information as a texture mapping onto the geometry that was previously created. This system permits measurement of epicardial electrodynamics over a geometrically realistic representation of the actual heart being studied. To verify the accuracy of the algorithm, the procedure was applied to synthetic images of a patterned ball; further verification was provided by application of the algorithm to a model heart placed in the experimental setup. Both sets of images produced mean registration image errors on the order of 2 pixels, corresponding to roughly 3 mm on the geometry. We demonstrate the algorithm by visualizing epicardial wavefronts on an isolated, perfused rabbit heart.

Algorithms↗

Noninvasive detection of ischemic bowel.

PURPOSE: Acute mesenteric arterial occlusion is an abdominal catastrophe that carries high morbidity and mortality rates. Current diagnostic methods, however, lack sensitivity and specificity and do not provide information about the viability of the affected bowel. Early diagnosis and intervention would improve patient outcomes and survival rates. The basic electrical rhythm (BER) is the omnipresent electrical slow wave of the gastrointestinal tract that characterizes the underlying electrical activity of the bowel. BER frequency is known to fall with ischemia. Superconducting quantum interference devices (SQUIDs) can detect BER by measuring the magnetic fields generated by the electrical activity of the smooth muscle of the small bowel. The purpose of this study was to determine the ability of a SQUID to detect mesenteric ischemia in a free-lying section of small bowel in an animal model of acute superior mesenteric artery occlusion. METHODS: Seven adult male rabbits (six experimental and one control) were studied with transabdominal SQUID and electrode recordings during baseline and after the induction of mesenteric ischemia with balloon occlusion of the superior mesenteric artery. Continuous recordings were taken for 120 minutes of ischemia and analyzed with autoregressive spectral analysis to determine the BER frequency during specific time points of the study. Two independent investigators blinded to the experimental preparation examined the results to determine whether there was decreased BER frequency and thus ischemia. The results are expressed as mean +/- SEM, and paired t tests were used to determine statistical significance. RESULTS: BER was detected in all seven animals and fell from 10.7 +/- 0.5 cpm to 7.0 +/- 1.8 cpm after 30 minutes of ischemia in the magnetic channels (P <.05, with t test). The fall in BER was detected by the SQUID in all six experimental animals. The blinded observers correctly identified healthy and ischemic magnetic data recording, with a sensitivity of 94% and specificity of 100%. CONCLUSION: SQUIDs can noninvasively detect bowel ischemia early in a free-lying segment of small bowel in this animal model with a high degree of sensitivity and specificity.

Animals↗

The human vector magnetogastrogram and magnetoenterogram.

Electrical activity in the gastrointestinal system produces magnetic fields that may be measured with superconducting quantum interference device magnetometers. Although typical magnetometers have detection coils that measure a single component of the magnetic field, gastric and intestinal magnetic fields are vector quantities. We recorded gastric and intestinal magnetic fields from nine abdominal sections in nine normal human volunteers using a vector magnetometer that measures all three Cartesian components of the magnetic field vector. A vector projection technique was utilized to separate the magnetic field vectors corresponding to gastric and intestinal activity. The gastric magnetic field vector was oriented in a cephalad direction, consistent with previously observed data, and displayed oscillatory characteristics of gastric electrical activity (f = 3.03 +/- 0.18 cycles/min). Although the small bowel magnetic field vector showed no consistent orientation, the characteristic frequency gradient of the small bowel electrical activity was observed. Gastric and intestinal magnetic field vectors were oriented in different directions and were thus distinguished by the vector projection technique. The observed difference in direction of gastric and intestinal magnetic field vectors indicates that vector recordings dramatically increase the ability to separate physiological signal components from nonphysiological components and to distinguish between different physiological components.

Analog-Digital Conversion↗

Quatrefoil reentry in myocardium: an optical imaging study of the induction mechanism.

INTRODUCTION: The "critical point hypothesis" for induction of ventricular fibrillation has previously been extended to infer the coexistence of four critical points, and hence four simultaneous spiral reentries or a quatrefoil reentry, resulting from only one premature stimulus delivered to the same location as the pacing stimulus. An optical imaging technique was used to explore its existence and to study the induction mechanism of this peculiar reentry pattern. METHODS AND RESULTS: In 16 isolated, Langendorff-perfused rabbit hearts, high-speed optical imaging at 133 or 267 frames/sec was performed to observe the induced response with a unipolar point electrode. A novel quatrefoil-shaped reentry pattern consisting of two pairs of opposing rotors was created by delivering long stimuli during the vulnerable phase. Successful induction occurred in a narrow range of coupling intervals. A dogbone pattern of virtual electrodes was established during the premature stimulus. Propagating wavefronts launched from the virtual anodes immediately after the termination of S2. The alternating blocking and conducting effects of the virtual electrodes, as well as the boundary between virtual cathode and virtual anode, provided the necessary pathways for quatrefoil reentry. Propagation directions of the reentrant spiral wavefronts reversed with a reversal in S2 polarity. Quatrefoil reentries were not sustained and lasted 1 to 4 complete cycles. CONCLUSION: The initiation of quatrefoil reentry followed anodal- or cathodal-break stimulation as a result of local symmetrical enhancement of the dispersion of tissue excitability. The "critical point hypothesis" provides the minimum topology required for this type of reentry; the "graded response hypothesis" can be viewed as providing a more detailed explanation of how this topology is actually realized. Triggering mechanisms due to the "break" mode of stimulation also posits a new mechanism for defibrillation.

Animals↗

Superconducting quantum interference device magnetometer for diagnosis of ischemia caused by mesenteric venous thrombosis.

Although mesenteric venous thrombosis carries a better prognosis than arterial thrombosis, mortality and morbidity are still high. Previous studies have shown that the basic electrical rhythm (BER) of the bowel decreases early after induction of arterial ischemia. Furthermore, our studies have shown that these changes occur prior to pathologic changes and that they can be recorded noninvasively using a superconducting quantum interference device (SQUID). SQUIDs measure magnetic fields that are created by the electrical activity of the gastrointestinal smooth muscle and have been used to measure the BER of the small intestine in human volunteers. This study was conducted to determine if a SQUID could be used for early noninvasive detection of mesenteric venous ischemia in an animal model. Simultaneous recordings from serosal electrodes and a SQUID outside the abdomen were taken from anesthetized New Zealand rabbits. Recordings were made for 15 minutes before and 90 minutes after injection of thrombin into the superior mesenteric vein. The basic electrical rhythm of the small bowel dropped from 16.42 +/- 0.69 to 8.80 +/- 0.74 cycles per minute at 30 minutes and to 6.82 +/- 0.722 after 90 minutes (p < 0.0001, paired t-test). The correlation coefficient between the SQUID and electrical recordings was 0.954 (p < 0.0001). These data suggest that the ischemia caused by mesenteric venous thrombosis results in changes in the bioelectrical activity, which can be noninvasively detected using a SQUID.

Animals↗

Effects of bath resistance on action potentials in the squid giant axon: myocardial implications.

This study presents a simplified version of the quasi-one-dimensional theory (Wu, J., E. A. Johnson, and J. M. Kootsey. 1996. A quasi-one-dimensional theory for anisotropic propagation of excitation in cardiac muscle. Biophys. J. 71:2427-2439) with two components of the extracellular current, along and perpendicular to the axis, and a simulation and its experimental confirmation for the giant axon of the squid. By extending the one-dimensional core conductor cable equations, this theory predicts, as confirmed by the experiment, that the shapes of the intracellular and the extracellular action potentials are related to the resistance of the bath. Such a result was previously only expected by the field theories. The correlation between the shapes of the intracellular and the extracellular potentials of the giant axon of the squid resembles that observed during the anisotropic propagation of excitation in cardiac muscle. Therefore, this study not only develops a quasi-one-dimensional theory for a squid axon, but also provides one possible factor contributing to the anisotropic propagation of action potentials in cardiac muscle.

Action Potentials↗