Search PubMed⌕ Search

Biomedical subjects

J P Quintana

Publications and source records attributed to J P Quintana.

8 recordsLinked to original sources

Shock temperature measurement using neutron resonance spectroscopy.

We report a direct measurement of temperature in a shocked metal using Doppler broadening of neutron resonances. The 21.1-eV resonance in 182W was used to measure the temperature in molybdenum shocked to approximately 63 GPa. An explosively launched aluminum flyer produced a planar shock in a molybdenum target that contained a 1-mm thick layer doped with 1.7 at. %(182)W. A single neutron pulse, containing resonant neutrons of less than 1 mus duration, probed the shocked material. Fits to the neutron time-of-flight data were used to determine the temperature of the shocked molybdenum.

Journal Article↗

On the structure of aragonite.

High-resolution synchrotron powder diffraction measurements were carried out at the 32-ID beamline of the Advanced Photon Source of Argonne National Laboratory in order to clarify the structure of geological aragonite, a widely abundant polymorph of CaCO(3). The investigated crystals were practically free of impurity atoms, as measured by wavelength-dispersive X-ray spectroscopy in scanning electron microscopy. A superior quality of diffraction data was achieved by using the 11-channel 111 Si multi-analyzer of the diffracted beam. Applying the Rietveld refinement procedure to the high-resolution diffraction spectra, we were able to extract the aragonite lattice parameters with an accuracy of about 20 p.p.m. The data obtained unambiguously confirm that pure aragonite crystals have orthorhombic symmetry.

Journal Article↗

Depth-resolved strain measurements in polycrystalline materials by energy-variable X-ray diffraction.

An energy-variable synchrotron diffraction technique is being established as a novel method for the depth-resolved measurement of residual strains in polycrystalline structures. An analytic expression for the diffraction profile is obtained by taking into account the instrument misalignment, change of the height of an incident X-ray beam with energy, and penetration of X-rays into the sample depth. It is shown that the maximum diffraction intensity recorded in the detector is coming from a certain depth beneath the surface of the sample, the depth being energy-dependent. This finding opens a way for precise strain measurements with high depth resolution by changing the X-ray energy in small enough steps. An experimental example, residual strain measurements across an alumina/zirconia multilayer, demonstrates the capability of the method.

Journal Article↗

Measurement of the speed of X-rays.

X-ray pulses from the Advanced Photon Source at Argonne National Laboratory were used to measure the speed of X-rays in the energy range between 21 and 60 keV. An LiNbO(3)-based 0.58 GHz surface acoustic wave device served as a temporal analyzer in the stroboscopic time-resolved diffraction measurements. By synchronizing the surface acoustic wave excitation and periodic X-ray illumination of the LiNbO(3) crystal, the temporal modifications in the LiNbO(3) diffraction profiles could be followed and the time points of X-ray arrivals at the analyzer position for different analyzer to storage ring distances determined. The speed of the X-rays was determined as the ratio of measured spacings and corresponding delay time intervals. Within the experimental error bars, the obtained X-ray velocities converged to the tabulated constant for the speed of light in a vacuum.

Journal Article↗

Quick X-ray absorption spectroscopy for determining metal speciation in environmental samples.

We present a method for determining the chemical speciation of metals in environmental particles based on Quick-X-ray Absorption Spectroscopy. The approach can be applied to either the extended or the near edge fine structure, and consists in the decomposition of the XAS spectrum of an unknown sample on a reference set of standards' spectra using quadratic linear programming. The analysis accounts for the statistical experimental errors generated during the acquisition of X-ray absorption data, and leads to error estimates on the various fractions determined via a Monte Carlo procedure. An application example is presented for the speciation of inorganic Zn in a contaminated sediment sample.

Geologic Sediments↗

SCIPE - a simple control interface protocol for experimenters.

The simple control interface protocol for experimenters (SCIPE) used at Sector 5 of the Advanced Photon Source is presented. This interface provides a generic method for data-acquisition programs to control generic actuators and detectors on a synchrotron beamline. The implementation used by the DuPont-Northwestern-Dow Collaborative Access Team, based on readily available hardware, is also described.

Journal Article↗

Adaptive silicon monochromators for high-power wigglers; design, finite-element analysis and laboratory tests.

Multipole wigglers in storage rings already produce X-ray power in the range up to a few kilowatts and planned devices at third-generation facilities promise up to 30 kW. Although the power density at the monochromator position is an order of magnitude lower than that from undulators, the thermal strain field in the beam footprint can still cause severe loss of performance in X-ray optical systems. For an optimized adaptive design, the results of finite-element analysis are compared with double-crystal rocking curves obtained with a laboratory X-ray source and, in a second paper [Quintana, Hart, Bilderback, Henderson, Richter, Setterson, White, Hausermann, Krumrey & Schulte-Schrepping (1995). J. Synchotron Rad. 2, 1-5], successful tests at wiggler sources at CHESS and ESRF and in an undulator source at HASYLAB are reported.

Journal Article↗

Adaptive Silicon Monochromators for High-Power Insertion Devices. Tests at CHESS, ESRF and HASYLAB.

X-ray wigglers which produce tens of kilowatts of photon power within the white beam will soon become available at third-generation sources of synchrotron radiation. Insertion devices that produce several kilowatts already exist and we have used those at CHESS, ESRF and HASYLAB to test adaptive 111 silicon water-jet-cooled monochromators at up to 2 kW total incident beam power. This development from earlier work at the Brookhaven National Synchrotron Light Source (NSLS) uses the pressure in the water coolant to provide active compensation of the strain field in the thermal footprint, nulling its effect to within residual variations in Bragg angle of only a few arc s. The design is robust, vacuum compatible and uses no moving mechanical parts.

Journal Article↗