Search PubMed⌕ Search

Biomedical subjects

J P Franke

Publications and source records attributed to J P Franke.

At least 19 recordsLinked to original sources

Feasibility of the direct coupling of solid-phase extraction-pipette tips with a programmed-temperature vaporiser for gas chromatographic analysis of drugs in plasma.

Solid-phase extraction-pipette tips (SPE-PTs) were used for micro solid-phase extraction of lidocaine and diazepam from plasma. Off-line extraction was followed by on-line desorption. On-line desorption was carried out by direct coupling of the SPE-PTs with the liner of the programmed-temperature vaporiser. This coupling only required shortening of the liner by maximally 16 mm, cutting the SPE-PT, and equipping the remaining part with two O-rings. Due to the heating of the injector the SPE-PTs were heated as well, which resulted in a significant amount of impurities. Pre-heating and pre-washing was performed prior to the extraction to reduce the impurity level. The internal coupling device was applied successfully for the analysis of plasma samples with gas chromatography (GC) and mass-selective detection. Detection limits of 0.75 ng/ml and 2.5 ng/ml were obtained for lidocaine and diazepam, respectively, using 200 microl plasma. Recoveries for both compounds were about 80%. Although it is possible, the internal coupling device was not developed to be used as such. The main goal of this coupling was to show the feasibility of the integration of SPE-PTs with GC and to realize an important step to new automated SPE-GC systems.

Chromatography, Gas↗

Screening for the presence of drugs in serum and urine using different separation modes of capillary electrophoresis.

Capillary electrophoresis (CE) is a modern separation technique that has some distinct advantages for toxicological analysis, such as a high efficiency, fast analysis, flexibility, and complementary separation mechanisms to chromatographic methods. CE can be applied in various modes, which each have a different separation mechanism or selectivity. The most common mode is capillary zone electrophoresis (CZE), in which charged analytes migrate in a buffer under the influence of an electric field. In micellar electrokinetic chromatography (MEKC), micelles are added to the buffer which interact with the analytes. MEKC can also be used for the separation of neutral compounds. In non-aqueous CE (NACE), the aqueous buffer is replaced by a background of electrolytes in organic solvents. A sample that needs to be screened can easily be analyzed subsequently by these CE modes using the same instrumentation. The aim of the study was to develop procedures for the analysis of basic and acidic drugs in serum and urine using CZE, MEKC, and NACE. A test mixture that consisted of six basic and six acidic compounds was used to study the separation behavior of five CE methods. The results showed that three methods (based on CZE, MEKC, and NACE) were suitable for the analysis of basic compounds and three methods (based on CZE and MEKC) for the analysis of acidic compounds. For the extraction of analytes from serum and urine, a solid-phase extraction (SPE) and a liquid-liquid extraction (LLE) method were compared. Both SPE and LLE methods provided clean extracts after extraction of the basic compounds from serum and urine. The extracts of acidic compounds contained more matrix interferences, especially for urine. The SPE method had some advantages compared to LLE, as it lead to cleaner extracts and higher peaks, and as it elutes basic and acidic compounds in one fraction. The potentials and pitfalls of the various methods for screening purposes in analytical toxicology are discussed.

Chromatography, Micellar Electrokinetic Capillary↗

Dynamically coated capillaries improve the identification power of capillary zone electrophoresis for basic drugs in toxicological analysis.

In systematic toxicological analysis (STA), analytical methods should have a high identification power. This can be suitably expressed by parameters such as mean list length (MLL) or discriminating power (DP). The reproducibility of a method has a great impact on its identification power, and should be as high as possible. In this study, two separation methods based on capillary zone electrophoresis (CZE) were evaluated towards STA applications. Besides a normal phosphate buffer, the commercially available buffer CElixir was used, which is a double-layer dynamic coating system. The coating stabilizes the endoosmotic flow, is independent of the pH, and is claimed to be more reproducible and faster at low pH than with normal buffers. A test set of 73 basic pharmaceutical compounds was analyzed by the two CZE methods. The total analysis time, including rinsing steps, was 8 min when the coating was used and 18 min without the coating. Effective mobilities were calculated and the reproducibilities were a factor of 2 better when the coating was used (between-days SD 0.020 and 0.040 m2/V s with and without the coating, respectively). MLL and DP were calculated for the two CZE methods and for combinations with standardized liquid and gas chromatography systems. CZE with CElixir coating clearly has a high potential for STA applications, as it was shown to have a higher identification power and shorter analysis times than normal CZE.

Electrophoresis, Capillary↗

Adsorptive voltametry to determine platinum levels in plasma from testicular cancer patients treated with cisplatin.

Patients cured of metastatic testicular cancer with cisplatin chemotherapy may suffer late adverse effects even after 20 years. The cause of these late adverse effects has not been elucidated yet. One cause might be prolonged tissue retention of platinum in these patients. Therefore, an extremely sensitive method for measuring platinum in plasma was used to investigate whether platinum is still detectable in plasma 10 to 20 years after cisplatin chemotherapy. High-pressure decomposition of plasma is followed by adsorptive voltametric determination of platinum, with a limit of quantification of 6 pg/g plasma. This procedure appeared suitable for the measurement of platinum in 44 former patients with platinum levels ranging from 22 to 140 pg/g plasma. This method is approximately 6000 times more sensitive than the standard flameless atomic absorption spectrophotometry (AAS) method. The platinum levels of these 44 patients were significantly elevated when compared with 20 control patients who were cured of testicular cancer but did not receive cisplatin chemotherapy (p < 0.001). There was a significant correlation between plasma platinum concentrations and follow-up time after cisplatin administration (r = -0.658, p < 0.001). This study shows that patients with testicular cancer who were treated with cisplatin can retain platinum in their body for at least 20 years. More data are needed to investigate whether there is a relation between the prolonged retention of platinum and long-term toxicity.

Adolescent↗

How to approach substance identification in qualitative bioanalysis.

The ultimate goal in qualitative analysis in the biosciences is to demonstrate with acceptable probability that for an unknown constituent in a sample only one substance comes into consideration and that all other substances can be rejected. In the biosciences, identification of relevant substances in complex matrices through database retrieval is frequently required. Yet, despite its importance, the subject has not received much attention, so that progress has been limited and relevant literature is scarce. As a result, one can conclude from many publications and reports that qualitative analysis in practice is often not being addressed properly. In this paper, some fundamental aspects of qualitative analysis will be discussed and a general approach is provided for the correct identification of organic substances in complex matrices through database retrieval. Special attention is given to the choice of proper analytical techniques and their inter-laboratory standard deviations, as well as to match factors and decision criteria based on applying multiple analytical techniques, also if the latter have different dimensions (e.g. retention data and spectral data). In addition, the requirements for suitable databases are outlined and the need for inter-laboratory cooperation is emphasized.

Databases, Factual↗

Intra- and interinstrument reproducibility of migration parameters in capillary electrophoresis for substance identification in systematic toxicological analysis.

The intra- and interinstrument reproducibilities of four capillary electrophoresis instruments were studied for identification purposes in systematic toxicological analysis (STA). A test set of 20 acidic test compounds and 5 reference compounds were analyzed for five days on each instrument using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). The buffers consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate and 50 mM sodium dodecyl sulfate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries at an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA. To deal with the poor reproducibility of the migration time, we recently introduced the corrected effective mobility. In this study, we investigated the intra- and interinstrument reproducibility of the migration time, the effective mobility, and the corrected effective mobility. Large differences in intra-instrument reproducibility were found when the migration time was used. The calculation of the effective mobility and the corrected effective mobility diminished these differences and enhanced the interinstrument reproducibility roughly by a factor 3. For (corrected) effective mobilities, intrainstrument reproducibilities were between 0.8-2.6% and interinstrument reproducibilities were between 3.2-3.9%.

Chromatography, Micellar Electrokinetic Capillary↗

SPEC disc solid-phase extraction for rapid broad-spectrum drug screening in urine.

Broad-spectrum drug screening requires that all relevant substances be isolated, detected, and identified, regardless of their structure and/or polarity. To this end, systematic solid-phase extraction (SPE) approaches for drug isolation from biological fluids are required. Because speed and cost effectiveness are key issues in analytical toxicology, we have evaluated a disc-format extraction device for this purpose and compared the latter with an existing packed-bed column-format method. The discs were SPEC.PLUS.C18AR/MP3 cartridges with 10-mL solvent reservoirs, providing hydrophobic and cation exchange interactions. Blank human urine was spiked at 2 microg/mL with a selection of acidic, neutral, and basic drugs representing a variety of relevant drug classes. Urine specimens (2 mL) were diluted with 2 mL 0.1 M phosphate buffer (pH 5.0) and then applied to the preconditioned disc. Washing was done with 1 mL water. Acidic and neutral drugs were eluted with 1 mL ethyl acetate/acetone (1:1), and basic drugs were eluted with 1 mL ammoniated ethyl acetate. The eluates were collected separately, evaporated down to about 0.1 mL, and analyzed by gas chromatography-flame-ionization detection to check cleanliness, recoveries, and reproducibilities. The discs showed good extraction properties for all drugs and were easy to handle. Recoveries were 75-100% with coefficients of variation of around 5%. The resulting eluates showed only a few matrix interferences. As compared to our standard SPE method with packed-bed columns, the disc procedure allowed reductions in elution volumes and total processing time of approximately 60-65%.

Barbiturates↗

Evaluation of the programmed temperature vaporiser for large-volume injection of biological samples in gas chromatography.

The use of a programmed temperature vaporiser (PTV) with a packed liner was evaluated for the injection of large volumes (up to 100 microl) of plasma extracts in a gas chromatograph. Solvent purity, which is essential when large volumes are injected into the GC system, was determined. Special attention was paid to the purity of the solvents used for the solid-phase extraction (SPE) procedure. For this SPE method, ethyl acetate was used as the extraction and reconstitution solvent, and thus the purity of the ethyl acetate was critical, especially when a non-selective GC detector was applied. The liquid capacity and inertness of different packed liners were investigated. The liner packed with ATAS "A" (modified Chromosorb-based material with special treatment) was found to be the most suitable for the analysis of the tested drugs. Good linearity in response for variations in volume and concentration was observed. A comparison was made between the applicability of flame ionisation detection (FID) and mass-selective detection (MSD). When 50-microl volumes of plasma extracts were injected with the PTV, the detection limits for secobarbital, lidocaine, phenobarbital and diazepam were about 50-times lower than when 1-microl volumes were injected. The detection limits of the tested compounds in plasma for injection of 50-100 microl plasma extract are 5-10 ng/ml for GC-FID whereas plasma concentrations of 250 pg/ml can be detected using the selected ion monitoring (SIM) mode of a MSD. For non-selective GC-FID, the background from a 50-microl injection was substantially larger than with 1-microl injection as a result of co-injected plasma matrix components and solvent impurities. These background effects were less with GC-MSD in the total ion current mode and virtually absent with GC-MSD in the SIM mode.

Blood Chemical Analysis↗

Multiresidue analysis of beta2-agonist in human and calf urine using multimodal solid-phase extraction and high-performance liquid chromatography with electrochemical detection.

Various beta2-agonists are used as illegal growth promoters in man and in animals. We developed a multiresidue procedure for the analysis of four beta-agonists in human and calf urine. The sample was pre-extracted with an Extrelut column at alkaline pH. The beta-agonists were eluted with a mixture of tert.-butylmethyl ether and hexane. Then the extract was further cleaned with a mixed mode SPE column, or with a combination of immunoaffinity chromatography (IAC) and the mixed mode SPE column. The IAC column contained antibodies against salbutamol, which were suitable for multiresidue extractions. The extract was then brought onto a mixed mode SPE column at an acidic pH. The column was washed with 70% methanol in water. Thereafter, the beta-agonists were eluted with ammoniated ethanol-hexane. The extract was analysed with an HPLC method with electrochemical detection. The beta-agonists were separated on a reversed-phase column using a mobile phase buffered at pH 5.5 and containing an ion-pair reagent. Recoveries were higher when the IAC procedure was not performed (90-105% vs. 65-75%), but the extracts were cleaner when the latter step was included. Detection limits in human and calf urine were in the low ng/ml range. The study indicated that beta2-agonists can be analysed in human and calf urine without the selectivity of a mass spectrometer, but that comprehensive clean-up is required to avoid the interference of urine matrix components.

Adrenergic beta-2 Receptor Agonists↗

Evaluation of capillary electrophoretic techniques towards systematic toxicological analysis.

Two capillary electrophoresis (CE) methods were evaluated for their suitability in systematic toxicological analysis (STA). A test set of 25 barbiturates was analysed using capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC). Buffers used consisted of 90 mM borate set at pH 8.4 (CZE) and 20 mM phosphate, 50 mM sodium dodecyl sulphate set at pH 7.5 (MEKC). All analyses were carried out using fused silica capillaries using an electric field strength of 52.6 kV/m. The use of a reproducible identification parameter is very important in STA as it influences the identification power (IP). To deal with the poor reproducibility of the migration time, we introduced the corrected effective mobility. Inter-day reproducibilities of the latter parameter were < 0.6% for CZE and < 0.5% for MEKC, using daily prepared buffers. The IP of the methods was expressed by calculation of the discriminating power and the mean list length. Data obtained were compared to gas chromatographic and high-performance liquid chromatographic data, and correlations between all methods were calculated. It was shown that little correlation exists between chromatographic and electrophoretic techniques. The results indicated that CE has a good identification power for the application in STA, especially when a combination of methods having a low correlation is used.

Barbiturates↗

Multi-residue analysis of anabolics in calf urine using high-performance liquid chromatography with diode-array detection.

We describe the development of an HPLC method with diode-array detection (DAD) for the analysis and identification of 20 substances with anabolic properties, that are considered as potential growth promoters, to be used for the analysis of extracts of calf urine samples. The substances are separated on an RP-Select B column using a mobile phase consisting of a mixture of acetonitrile and water. Gradient elution from 43-76% acetonitrile in water with a concave curve was used to achieve a good separation of the compounds with an acceptable analysis time. For the identification, a retention parameter and the UV spectrum were used. The retention parameter was the retention time corrected with a reference mixture. The latter reduced the standard deviations to about 25% of their original values. The limits of detection of the HPLC system ranged from 0.5-5 ng injected amount for the androgens, progestagens, stilbenes and resorcylic acid lactones and to 5-10 ng injected amount for the oestrogens. After extraction from urine the limits of detection were increased by the presence of matrix components, but they were between 5 and 10 ng injected amount for most of the substances.

Anabolic Agents↗

Solid-phase extraction procedures in systematic toxicological analysis.

In systematic toxicological analysis (STA) the substance(s) present is (are) not known at the start of the analysis. In such an undirected search the extraction procedure cannot be directed to a given substance but must be a general procedure where a compromise must be reached in that the substances of interest are isolated at a yield as high as possible and the interfering substances from the biological material are removed. When using solid-phase extraction (SPE) it is desirable to have procedures using just one column. An overview of screening procedures using diatomaceous earth, polystyrene-divinylbenzene copolymer and mixed-mode bonded silica as column material in SPE is given. The latter type of sorbent is most popular at the moment and the critical steps in the procedure are outlined in more detail. Recent developments of SPE disks look very promising for STA.

Adsorption↗

Direct enantiomeric separation of mianserin and 6-azamianserin derivatives using chiral stationary phases.

The direct enantiomeric separation of mianserin and 6-azamianserin and some of their derivatives, respectively, by means of HPLC using two different chiral selectors was investigated. For the cellulose-based Chiralcel OD column, a strong dependence of the lipophilicity of the compounds tested on the retention behaviour was observed. To some extent, this was also found for the enantiomeric separation on the amylose-based Chiralpak AD column. In some cases a complementary behaviour of these two phases was observed: racemic mixtures that could not be separated by one column could be resolved by the other one.

Adrenergic alpha-Antagonists↗

Toxicological analysis of whole blood samples by means of Bond-Elut Certify columns and gas chromatography with nitrogen-phosphorus detection.

The application of Bond-Elut Certify solid-phase extraction columns to the systematic toxicological analysis of whole blood was evaluated. The reproducibility of the extraction was tested with thirteen drugs varying in physico-chemical properties. Analysis was performed with capillary gas chromatography with nitrogen-selective detection. The recoveries were reproducible, as long as other limiting factors, e.g., chromatographic behaviour or volatility, do not play a significant role. The effect of limiting chromatographic behaviour was studied in more detail with the more sensitive mass spectrometry with selected-ion monitoring after converting the extracted morphine into its ditrimethylsilyl derivative.

Blood Chemical Analysis↗

Application of radioreceptor assays for systematic toxicological analysis--1. Procedures for radioreceptor assays for antihistaminics, anticholinergics and benzodiazepines.

Radioreceptor assays can be a useful tool for systematic toxicological analysis in that they can be applied for the detection of an entire pharmacological class of drugs. In the present paper procedures for radioreceptor assays for benzodiazepines, anticholinergics and antihistaminics have been described in detail. The development of the assay for antihistaminics in urine is given in order to illustrate the prerequisites for these types of assays with regard to the incubation conditions. In part 2 the applicability of the three assays for systematic toxicological analysis will be evaluated on the basis of testing a large number of urine samples after administration of a selected number of drugs to healthy volunteers and patients.

Animals↗

Application of radioreceptor assays for systematic toxicological analysis--2. Theoretical considerations and evaluation.

In this paper the applicability of radioreceptor assays for systematic toxicological analysis will be evaluated on a theoretical basis as well as on the basis of the outcomes of the analysis of a large number of urine samples collected after administration of a selected number of drugs to healthy volunteers and patients. Many drugs and other substances of toxicological relevance exert their action through an interaction with one or more receptor (sub)types. Whether the number of persons are using particular drugs intentionally or unintentionally, radioreceptor assays can be a useful tool for systematic toxicological analysis in that they can be applied to the identification of entire pharmacological classes of substances as well as pharmacologically active metabolites. In part 1 of this paper detailed procedures for radioreceptor assays for benzodiazepines, anticholinergics and antihistaminics have been described in detail in order to illustrate not only the potentials but also the limitations of assay conditions. Fifteen drugs were administered to patients and volunteers and urine samples were collected and determined with the three radioreceptor assays. The results of this study underline the theoretical applicability of receptor assays in systematic toxicological analysis though sample pretreatment procedures may contribute to an improvement in sensitivity and applicability to other biofluids.

Benzodiazepines↗

Reusability of Bond Elut Certify columns for the extraction of drugs from plasma.

The reusability of Bond Elut Certify columns for the extraction of toxicologically relevant drugs from plasma has been evaluated. Pentobarbital, hexobarbital, mepivacaine, trimipramine and clonazepam were selected as test drugs to represent various classes of drugs. The columns were regenerated immediately after an extraction by washing with methanol, hydrochloric acid (1%), water and methanol, sequentially. These regenerated columns were found to be reusable for plasma. More than 85% of the test drugs were recovered when the columns were used three times. However, the extraction power of the regenerated columns decreased slightly with the number of reuses, so that a column should not be used more than two or three times.

Animals↗

Study of lot-to-lot reproducibilities of Bond Elut Certify and Clean Screen DAU mixed-mode solid-phase extraction columns in the extraction of drugs from whole blood.

The lot-to-lot reproducibilities of Bond Elut Certify and Clean Screen DAU columns are described. The recoveries of five test drugs obtained from twelve lots of Bond Elut Certify columns ranged from 84 to 104% with standard deviations of less than 9%. The recoveries of five test drugs obtained from six lots of Clean Screen DAU columns ranged from 81 to 103% with standard deviations of less than 7%. The 95% confidence intervals of the means as obtained by ANOVA demonstrate that there are no significant differences between the tested lots of Bond Elut Certify and Clean Screen DAU columns. Comparison of the two brands shows that both Bond Elut Certify and Clean Screen DAU columns are well acceptable for routine drug screening in systematic toxicological analysis, with a slightly higher overall recovery for the former.

Animals↗