Search PubMed⌕ Search

Biomedical subjects

J P Carrozza

Publications and source records attributed to J P Carrozza.

64 records · Page 4Linked to original sources

Restenosis after arterial injury caused by coronary stenting in patients with diabetes mellitus.

OBJECTIVE: To determine whether diabetic patients, when compared with nondiabetic patients, have a higher incidence of restenosis after coronary stenting, and, if so, whether restenosis is attributable to lesion or procedural differences or to a greater biologic tendency for late loss of minimum diameter in diabetic patients. DESIGN: Case series. SETTING: Tertiary care referral center. PATIENTS: Two hundred twenty consecutive patients with coronary artery disease who were referred for placement of a Palmaz-Schatz stent in either a native coronary artery or a saphenous vein graft. RESULTS: Based on a traditional dichotomous definition of restenosis (> or = 50% stenosis at follow-up), lesions in diabetic patients had a significantly greater restenosis rate (55%) than lesions in nondiabetic patients (20%; P = 0.001). Vessel size, lesion length, pre-procedure lesion severity, procedural outcome, and acute gain (the difference between minimum lumen diameter before and after the procedure) were similar in the diabetic and nondiabetic groups. However, at follow-up, stents in diabetic patients had a smaller lumen diameter (1.66 +/- 1.18 mm) compared with those in nondiabetic patients (2.24 +/- 0.93 mm; P = 0.004), as well as a greater percent stenosis (49% compared with 32%; P = 0.002). Thus, the increased restenosis rate in stents in diabetic patients (55% compared with 20%; P = 0.001) is secondary to increased late loss of minimum lumen diameter (1.66 +/- 1.28 mm compared with 1.23 +/- 0.97 mm; P = 0.04). CONCLUSIONS: After arterial injury produced by stent placement, diabetic patients have a significantly greater incidence of restenosis because of greater late loss at the treatment site. Because elastic recoil or vasospasm contributes little to stent restenosis, the increased late loss of minimum lumen diameter in diabetic patients suggests that they have a greater predisposition to intimal hyperplasia.

Aged↗

Mechanisms of restenosis and redilation within coronary stents--quantitative angiographic assessment.

OBJECTIVES: This study was designed to assess the relative contributions of intimal hyperplasia and stent compression to the lumen narrowing seen after intracoronary stenting and to determine whether the lumen enlargement produced by angioplasty of in-stent restenosis results primarily from compression or extrusion of intimal hyperplasia through the stent or from additional stent expansion. BACKGROUND: Palmaz-Schatz stent placement outwardly displaces plaque and eliminates elastic vessel recoil to provide a large and smooth lumen. Some degree of late lumen narrowing occurs within each stent and causes significant restenosis (> or = 50% stenosis) in 25% to 30% of treated lesions. It has not been clear, however, whether this narrowing results from stent compression (crush) or from in-stent intimal hyperplasia. Because the Palmaz-Schatz stent has a distinct radiographic shadow, it is possible to determine the late diameter of both the stent and the enclosed vessel lumen to assess the relative contributions of these two processes. METHODS: From cineangiograms, initial (after stenting) and late (follow-up) lumen and stent diameters were examined in 55 patients (59 stents, group I) who had both immediate and 6-month (192 +/- 117 days) angiography. Lumen and stent diameter were also examined before and after dilation in 30 patients (30 stents, group II) who underwent angioplasty of severe in-stent restenosis. RESULTS: Late loss in minimal lumen diameter was 0.99 +/- 0.87 mm for group I despite only a slight (0.03 +/- 0.23-mm) reduction in the corresponding stent diameter. After redilation for in-stent restenosis, the acute gain in minimal lumen diameter was 1.51 +/- 0.82 mm for group II, again without appreciable increase (0.06 +/- 0.20 mm) in stent diameter. CONCLUSIONS: Restenosis after intracoronary Palmaz-Schatz stenting appears to be due predominantly to lumen encroachment by intimal hyperplasia within the stent, with minimal contribution of stent compression. Lumen enlargement after coronary angioplasty of in-stent restenosis appears to be due primarily to compression or extrusion of intimal hyperplasia through the stent, or both, rather than to further stent expansion.

Aged↗

Long-term results of directional coronary atherectomy: predictors of restenosis.

OBJECTIVES: This study was performed to obtain better understanding of the long-term clinical efficacy of directional coronary atherectomy. BACKGROUND: Although this procedure yields favorable acute results, its acceptance has been limited by the perception that late results (that is, freedom from restenosis) are no better than those of conventional angioplasty. METHODS: A total of 225 atherectomies performed in 190 patients between August 1988 and July 1991 were examined. Minimal lumen diameter of the treated segments was measured on angiograms obtained before, after and 6 months after intervention. RESULTS: Although most lesions (97%) had one or more characteristics predictive of unfavorable short- or long-term results after conventional angioplasty, atherectomy was successful in 205 lesions (91%) with a mean residual stenosis of 7 +/- 16%. After subsequent balloon angioplasty in 16 unsuccessful atherectomy attempts, procedural success was 98%. There were no deaths or Q wave myocardial infarctions, and one patient (0.5%) underwent emergency bypass surgery. Six-month angiographic follow-up was obtained in 77% of the eligible patients. The overall angiographic restenosis rate was 32%. Predictors of a lower restenosis rate included a postprocedure lumen diameter > 3 mm (24% vs. 39%, p = 0.047), serum cholesterol < or = 200 mg/dl (18% vs. 40%, p = 0.018) and recent myocardial infarction (16% vs. 37%, p = 0.034). Life-table analysis showed a 2% mortality rate and a 26% incidence of other events (myocardial infarction, repeat revascularization) within the 1st year. The annual 5% mortality rate and 7% incidence of other events during years 2 and 3 were related in large part to the existence or progression of disease at other locations. CONCLUSIONS: Six-month angiographic follow-up of patients who underwent directional coronary atherectomy during the 1st 3 years of our experience shows an overall restenosis rate of 32%, with lower rates in patients with a postatherectomy lumen diameter > or = 3 mm, cholesterol level < or = 200 mg/dl or a recent myocardial infarction. Few if any events relating to the site of atherectomy developed after the 1st year of follow-up.

Atherectomy, Coronary↗

Acute and long-term outcome of narrowed saphenous venous grafts treated by endoluminal stenting and directional atherectomy.

Angioplasty of the narrowed saphenous vein bypass grafts remains a difficult challenge. Over a 37-month period at this institution, 119 of 176 interventions (68%) on saphenous vein grafts (average age 8.3 years from bypass surgery to graft intervention) were performed using either directional coronary atherectomy (n = 35) or Palmaz-Schatz intracoronary stents (n = 84), representing 37% of all stents and 15% of all atherectomies during the study period, respectively. Of the 57 saphenous vein graft lesions treated with conventional balloon angioplasty during this period, 49 (86%) had 1 or more contraindications to stenting or directional atherectomy (thrombus, total occlusion, reference vessel less than 3 mm in diameter). The acute success rate was 99% for stents (1 failure to dilate) and 94% for directional atherectomy (2 failures to cross the lesion with the atherectomy device). Lumen diameter increased from 0.9 to 3.6 mm (reference vessel 3.6) for stents, and from 0.9 to 3.5 mm (reference 3.8) for atherectomy (for all comparisons, p = not significant), with no major complications (abrupt or subabrupt closure, emergent coronary bypass surgery, death, or Q-wave myocardial infarctions). During the same time period 50 of 57 vein grafts (88%) rejected for stenting or atherectomy were dilated successfully by conventional balloon angioplasty, with 3 patients (5%) requiring emergent coronary bypass surgery. Angiographic follow-up was available for 50 of 64 eligible patients (78%).(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

Frequency and outcome of chest pain after two new coronary interventions (atherectomy and stenting).

Between June 1988 and July 1991, 464 new device interventions (Palmaz-Schatz stent or Simpson directional atherectomy) were performed in 410 patients. Chest pain occurred within 72 hours after the procedure in 94 patients (23%). All patients were evaluated with electrocardiograms and cardiac isoenzymes on the day after the procedure, and urgent repeat coronary angiography was performed in 29 chest pain patients (31%). Whereas all 14 patients with abnormal findings on repeat angiography had electrocardiographic changes, 6 of the 20 restudied patients (30%) with electrocardiographic changes had no angiographic explanation for chest pain. Non-Q-wave myocardial infarction occurred in 22 patients (5%) (10 of 35 [29%] with chest pain and electrocardiographic changes, 3 of 44 [7%] with chest pain and no electrocardiographic change, and 9 of 316 [3%] without chest pain). Factors associated with chest pain after new device intervention included a decreased residual percent stenosis (p = 0.05), incomplete revascularization (p = 0.005) and the presence of multivessel disease (p = 0.001). Vessel dissection after stenting but not atherectomy was associated with postprocedure chest pain. Chest pain is common (23%) after new device intervention. Electrocardiographic changes are a sensitive marker of angiographic abnormality and confer a higher risk of non-Q-wave myocardial infarction, but no increase of in-hospital mortality. Determinants of postprocedure chest pain are lower residual percent stenosis, incomplete revascularization and the presence of multivessel disease. Patients with chest pain but no electrocardiographic changes early after successful stent placement or atherectomy need not routinely undergo urgent recatheterization.

Angina Pectoris↗

Angiographic and clinical outcome of intracoronary stenting: immediate and long-term results from a large single-center experience.

OBJECTIVES: The purpose of this study was to determine the immediate and long-term angiographic and clinical results of coronary stenting. BACKGROUND: Although preliminary trials of endovascular stenting have demonstrated promising results, lack of long-term follow-up has limited the critical evaluation of the role of coronary stenting in the treatment of obstructive coronary artery disease. METHODS: A total of 250 procedures using the Palmaz-Schatz stent, performed in 220 patients between June 1988 and July 1991, were examined. Minimal lumen diameter of the treated segments was measured on angiograms obtained before, after and 6 months after intervention. RESULTS: Stent placement was successful in 246 (98%) of 250 lesions, reducing diameter stenosis from 77% to -2.5%. There were no deaths or Q wave myocardial infarctions. One patient (0.4%) required emergency bypass surgery and one (0.4%) developed subacute thrombosis. Femoral vascular complications occurred in 36 patients (16%). Six-month angiographic follow-up was obtained in 91% of eligible patients. The overall angiographic restenosis rate (stenosis greater than or equal to 50%) was 25%. By univariable analysis, the rate of restenosis was significantly higher for stents in the left anterior descending versus the right coronary artery (44% vs. 12%; p = 0.002); in diabetic patients (56% vs. 20%; p = 0.006), and in vessels with post-stent lumen diameter less than 3.31 mm (34% vs. 16%; p = 0.05). Stenting of the left anterior descending artery was the strongest predictor (p = 0.01) of restenosis in a multivariable model. Total survival was 97% and event-free survival (freedom from death, myocardial infarction or revascularization) was 70% at 36 months. CONCLUSIONS: Palmaz-Schatz stents can be placed successfully with a low incidence of major complications. The angiographic restenosis rate was 25%, and 70% of patients remained free of cardiovascular events at 3 years. Diabetes, small postprocedure lumen diameter and stenting of the left anterior descending artery are associated with higher rates of restenosis.

Coronary Angiography↗

The importance of acute luminal diameter in determining restenosis after coronary atherectomy or stenting.

BACKGROUND: We evaluated native coronary arteries treated by directional coronary atherectomy or balloon-expandable stent placement in an effort to derive a quantitative geometric model relating the luminal diameter immediately after intervention to that present 6 months later. The minimal luminal diameter of each lesion was measured before and immediately after intervention in 102 single Palmaz-Schatz stents and 134 directional atherectomies, 192 (81%) of which had repeat angiographic measurement of minimal luminal diameter 6 months after the intervention. The immediate enlargement in luminal diameter produced by the intervention (acute gain) and the subsequent reduction in luminal diameter from the time of intervention to 6 months of follow-up (late loss) were calculated. METHODS AND RESULTS: Luminal diameter increased from 0.69 +/- 0.40 mm to 3.11 +/- 0.64 mm (acute gain, 2.41 +/- 0.64 mm) after intervention, providing an immediate postprocedure residual stenosis of 1 +/- 14% relative to a reference diameter of 3.13 +/- 0.65 mm. At 6-month follow-up, the late luminal diameter was 1.97 +/- 0.92 mm (late loss, 1.13 +/- 0.89 mm), yielding a late diameter stenosis of 36 +/- 26%. The restenosis rate (according to the traditional definition of diameter stenosis > or = 50%) was 30%. Multivariable analysis demonstrated that late luminal diameter (p = 0.02), late percent stenosis (p = 0.04), and restenosis (according to a > 50% definition, p = 0.04) were each strongly associated with the luminal diameter present immediately after the procedure. Whereas late luminal diameter was also influenced by reference artery size and the vessel treated (left anterior descending versus right coronary artery), reference vessel size was rejected by the multivariable models of late percent stenosis and binary restenosis after they were adjusted for the effect of postprocedure luminal diameter. Once adjusted for postprocedure luminal diameter, neither late luminal diameter nor late loss was found to be independently determined by which device was used (atherectomy versus stents). Rather, late loss was determined independently by the immediate postprocedure luminal diameter (p = 0.005) and the postprocedure percent stenosis (p = 0.02). Although late loss thus increased with acute gain, the net beneficial effect of increased acute gain was maintained: Late loss was only a fraction (0.47) of acute gain, so the ability of a larger postprocedure luminal diameter to reduce the probability of subsequent restenosis was preserved. CONCLUSIONS: This quantitative model demonstrates that the late coronary lumen diameter and the probability of restenosis after Palmaz-Schatz stenting or directional atherectomy are influenced strongly by the lumen diameter present immediately after the procedure rather than by the specific device used. Although the influence of a larger acute result on reduced restenosis appears to be well established in this treatment population, the interplay among the multiple other biological influences on restenosis limits the ability to predict the probability of restenosis for the individual patient based on a large acute result alone. Future studies of restenosis, however, can further refine this multivariable quantitative model by adjusting for the effects of other clinical variables, mechanical interventions, or drug therapies in addition to the clear effect of postprocedure luminal diameter.

Atherectomy, Coronary↗

Decreased myofilament responsiveness in myocardial stunning follows transient calcium overload during ischemia and reperfusion.

The purpose of this study was to test the hypothesis that abnormal intracellular calcium handling characterizes myocardial stunning. Isolated, isovolumic, buffer-perfused ferret hearts were loaded with the bioluminescent calcium indicator aequorin for simultaneous measurement of individual calcium transients and left ventricular pressure. After 15 minutes of global ischemia and 20 minutes of reperfusion, left ventricular developed pressure was significantly reduced (75 +/- 7 versus 93 +/- 6 mm Hg, p < 0.05). During ischemia, [Ca2+]i levels were significantly elevated compared with preischemic levels, both during systole (1.38 +/- 0.31 versus 0.88 +/- 0.2 microM, p < 0.05) and end diastole (0.85 +/- 0.16 versus 0.38 +/- 0.13 microM, p < 0.05). Early during reperfusion, [Ca2+]i was also significantly elevated during systole (1.63 +/- 0.44 versus 0.88 +/- 0.20 microM, p < 0.05) and end diastole (0.75 +/- 0.15 versus 0.38 +/- 0.13 microM, p < 0.05). After 20 minutes of reperfusion, myocardial stunning occurred, but [Ca2+]i was not significantly different from preischemic levels. Thus, myocardial stunning does not result from decreased levels of activator calcium. The force-pCa relation generated by the stunned hearts was shifted downward compared with that generated by the control hearts, consistent with a decrease in maximum calcium-activated force (Fmax). At steady state during tetanus, the decrease in Fmax was confirmed, but there was no significant difference in the slope of the force-pCa relation of the stunned hearts versus controls. Thus, we conclude that stunned myocardium is characterized by decreased Fmax without desensitization of the myofilaments to [Ca2+]i.(ABSTRACT TRUNCATED AT 250 WORDS)

Actin Cytoskeleton↗

Excitation-contraction uncoupling during ischemia in the blood perfused dog heart.

The bioluminescent of Ca(2+)-indicator, aequorin, was loaded into the left ventricular apex of blood-perfused hearts from 13 dogs for simultaneous recording of left ventricular pressure and intracellular calcium levels. During a 2 minute period of ischemia, systolic and diastolic pressures significantly decreased. In contrast, these pressure changes were associated with an increase in both systolic and diastolic calcium reaching a maximum diastolic value of 0.59 microM and a systolic value of 1.11 microM. This apparent dissociation between pressure and [Ca2+]i supports the hypothesis that changes in myofilament Ca2+ responsiveness are of major importance in modulating contractility during ischemia in large mammalian hearts.

Aequorin↗