Shear strain estimation and lesion mobility assessment in elastography.

Elastography typically measures and images the normal strain component along the insonification/compression axis, i.e., in the axial direction. We have recently shown that, by using interpolation and cross-correlation methods of transversely displaced RF echo segments, it is possible to measure and image displacement and strain transversely to the beam with good precision. This enables the estimation and imaging of all three principal normal strain components. Generally, motion in a direction other than that in which strain is estimated may result in decorrelation noise, severely corrupting the estimates. Therefore, a correction method is applied to correct the displacement and strain estimates for decorrelating motion. In this paper, we show how corrected displacement estimates can also be used to estimate and image the shear strain components. This may allow us to identify regions of decorrelation noise in the normal strain measurement that are due to shear strain. Shear strain estimates provide supplementary information, which can characterize different tissue elements based on their mobility. In the case of breast lesions, low mobility is related to malignancy. Following an in vivo case, we show with 2D simulations how assessment of tumor mobility can be achieved with shear strain estimation.

Breast Neoplasms↗

Nonlinear stress-strain relationships in tissue and their effect on the contrast-to-noise ratio in elastograms.

The practice of elastography is generally limited to small applied compressions (typically 1%), under the assumption of a linear stress-strain relationship in biological tissue. However, the recent reports of larger applied compressions and precompression levels to increase the strain contrast violate the above assumption. The nonlinear stress-strain relationships in different breast tissue types significantly alter the contrast in elastography, especially for large applied compression. The moduli of normal fibrous and glandular breast tissue (along with cancerous lesions) are strain-dependent, with tissue stiffness increasing with applied compression. In this paper, we illustrate that the strain-dependence of the modulus has a significant impact on the elastographic contrast and on the contrast-to-noise ratio, and may even cause a reversal of the contrast in certain situations. This paper also emphasizes the effect of the precompression strain level on the strain contrast.

Breast↗

Direct strain estimation in elastography using spectral cross-correlation.

Spectral estimation of tissue strain has been performed previously by using the centroid shift of the power spectrum or by estimating the variation in the mean scatterer spacing in the spectral domain. The centroid shift method illustrates the robustness of the direct, incoherent strain estimator. In this paper, we present a strain estimator that uses spectral cross-correlation of the pre- and postcompression power spectrum. The centroid shift estimator estimates strain from the mean center frequency shift, while the spectral cross-correlation estimates the shift over the entire spectrum. Spectral cross-correlation is shown to be more sensitive to small shifts in the power spectrum and, thus, provides better estimation for smaller strains when compared to the spectral centroid shift. Spectral cross-correlation shares all the advantages gained using the spectral centroid shift, in addition to providing accurate and precise strain estimation for small strains. The variance and noise properties of the spectral strain estimators quantified by their respective strain filters are also presented.

Acoustics↗

Precision estimation and imaging of normal and shear components of the 3D strain tensor in elastography.

In elastography we have previously developed a tracking and correction method that estimates the axial and lateral strain components along and perpendicular to the compressor/scanning axis following an externally applied compression. However, the resulting motion is a three-dimensional problem. Therefore, in order to fully describe this motion we need to consider a 3D model and estimate all three principal strain components, i.e. axial, lateral and elevational (out-of-plane), for a full 3D tensor description. Since motion is coupled in all three dimensions, the three motion components have to be decoupled prior to their estimation. In this paper, we describe a method that estimates and corrects motion in three dimensions, which is an extension of the 2D motion tracking and correction method discussed before. In a similar way as in the 2D motion estimation, and by assuming that ultrasonic frames are available in more than one parallel elevational plane, we used methods of interpolation and cross-correlation between elevationally displaced RF echo segments to estimate the elevational displacement and strain. In addition, the axial, lateral and elevational displacements were used to estimate all three shear strain components that, together with the normal strain estimates, fully describe the full 3D normal strain tensor resulting from the uniform compression. Results of this method from three-dimensional finite-element simulations are shown.

Computer Simulation↗

Theoretical bounds on the estimation of transverse displacement, transverse strain and Poisson's ratio in elastography.

The Cramér-Rao Lower Bounds (CRLB) are derived for the displacement and strain estimation in directions orthogonal to the ultrasonic beam axis, using a previously-described recorrelation method of axial, lateral and elevational motion estimation. We also compare it to the lateral tracking method that involves the sole use of the axial signal in the transverse direction. Our theoretical results, verified with simulations and phantom experiments, show that elastography is capable of measuring axial and transverse strain at up to 10% axially applied compression. Finally, we predict the performance of the estimation of the Poisson's ratio using decoupled axial and lateral estimates that result from the recorrelation method.

Computer Simulation↗

The feasibility of elastographic visualization of HIFU-induced thermal lesions in soft tissues. Image-guided high-intensity focused ultrasound.

The potential for visualizing high-intensity focused ultrasound (HIFU)-induced thermal lesions in biological soft tissues in vitro using elastography was investigated. Thermal lesions were created in rabbit paraspinal skeletal muscle in vivo. The rabbits were sacrificed 60 h following the treatment and lesioned tissues were excised. The tissues were cast in a block of clear gel and elastographic images of the lesions were acquired. Gross pathology of the tissue samples confirmed the characteristics of the lesions.

Animals↗

Elastographic characterization of HIFU-induced lesions in canine livers.

The elastographic visualization and evaluation of high-intensity focused ultrasound (HIFU)-induced lesions were investigated. The lesions were induced in vitro in freshly excised canine livers. The use of different treatment intensity levels and exposure times resulted in lesions of different sizes. Each lesion was clearly depicted by the corresponding elastogram as being an area harder than the background. The strain contrast of the lesion/background was found to be dependent on the level of energy deposition. A lesion/background strain contrast between -2.5 dB and -3.5 dB was found to completely define the entire zone of tissue damage. The area of tissue damage was automatically estimated from the elastograms by evaluating the number of pixels enclosed inside the isointensity contour lines corresponding to a strain contrast of -2.5, -3 and -3.5 dB. The area of the lesion was measured from a tissue photograph obtained at approximately the same plane where elastographic data were collected. The estimated lesion areas ranged between approximately 10 mm2 and 110 mm2. A high correlation between the damaged areas as depicted by the elastograms and the corresponding areas as measured from the gross pathology photographs was found (r2 = 0.93, p value < 0.0004, n = 16). This statistically significant high correlation demonstrates that elastography has the potential to become a reliable and accurate modality for HIFU therapy monitoring.

Animals↗

Power spectral strain estimators in elastography.

Elastography can produce quality strain images in vitro and in vivo. Standard elastography uses a coherent cross-correlation technique to estimate tissue displacement and tissue strain using a subsequent gradient operator. Although coherent estimation methods generally have the advantage of being highly accurate and precise, even relatively small undesired motions are likely to cause enough signal decorrelation to produce significant degradation of the elastogram. For elastography to become more universally practical in such applications as hand-held, intravascular and abdominal imaging, the limitations associated with coherent strain estimation methods that require tissue and system stability, must be overcome. In this paper, we propose the use of a spectral-shift method that uses a centroid shift estimate to measure local strain directly. Furthermore, we also show theoretically that a spectral bandwidth method can also provide a direct strain estimation. We demonstrate that strain estimation using the spectral-shift technique is moderately less precise, but far more robust than the cross-correlation method. A theoretical analysis, simulations and experimental results are used to illustrate the properties associated with this method.

Elasticity↗

A method for experimental characterization of the noise performance of elastographic systems.

Characterization of the noise performance of the elastographic system is necessary to evaluate the accuracy and precision of the estimated strain. The elastographic system includes the ultrasonic scanner, the computer controlled compression device and the strain estimation algorithm. In this paper, we present a method of characterizing the elastographic system experimentally using a uniformly elastic homogenous tissue-mimicking phantom. The strain response of the elastographic system is evaluated by characterizing the accuracy and precision of the strain estimates for a large range of input strains. The experimental results obtained follow the theoretical predictions obtained using the Strain Filter (SF) concept for the cross-correlation based strain estimator. In this paper, we illustrate the application of the Experimental Strain Response (ESR) to characterize strain estimation at the focus of the transducer and the axis of symmetry of the phantom.

Elasticity↗

Elastographic imaging of the normal canine prostate in vitro.

Elastography has been shown to be successful in mapping the relative mechanical attributes of normal as well as abnormal tissues. In this study, the histological characteristics of freshly excised normal canine prostates were used to explain consistently depicted elastographic features. The elastograms of the transverse cross-sections across the urethra demonstrated a consistent symmetry of the gland as well as clear anatomic structures. These include a central portion of the gland surrounding the urethra and a peripheral gland. The central gland was consistently softer than the peripheral gland. At the level of the verumontanum, depicted as a small stiff ridge, the lumen of the urethra was consistently demonstrated as an inverted soft 'u' or 'v' shaped area. The network of branching-fibrous connective tissue septa was depicted by the elastogram as linear features, which converged on the urethra. In the anterior side of the gland, the fibromuscular stroma was seen as a circumscribed hard tissue. In the sagittal view, the elastogram suggested a stiff peripheral zone surrounding a softer central zone, which is traversed by the urethra depicted as soft tissue.

Animals↗

Elastography: ultrasonic estimation and imaging of the elastic properties of tissues.

The basic principles of using sonographic techniques for imaging the elastic properties of tissues are described, with particular emphasis on elastography. After some preliminaries that describe some basic tissue stiffness measurements and some contrast transfer limitations of strain images are presented, four types of elastograms are described, which include axial strain, lateral strain, modulus and Poisson's ratio elastograms. The strain filter formalism and its utility in understanding the noise performance of the elastographic process is then given, as well as its use for various image improvements. After discussing some main classes of elastographic artefacts, the paper concludes with recent results of tissue elastography in vitro and in vivo.

Animals↗

Elastographic imaging of low-contrast elastic modulus distributions in tissue.

Elastography is a new ultrasonic imaging technique that produces images of the strain distribution in compliant tissues. This strain distribution is derived from ultrasonically estimated longitudinal internal motion induced by an external compression of the tissue. The displayed two-dimensional (2-D) images are called elastograms. In this paper, it is demonstrated that, when signal-to-noise ratio-enhancing techniques are used, elastography is capable of imaging low-contrast elastic modulus tissue structures with high contrast-to-noise ratios. This is demonstrated using both computer simulations and data obtained from 3 days postmortem ovine kidneys in vitro. The elastograms of such organs suggest that the modulus slowly decays from the renal cortex (RC) to the interior of the renal sinus (RS). Such modulus variation is corroborated by independent measurements of the Young's moduli. It is found that the RC is approximately twice as hard as the interior of the RS. We invoke our previous results on elastographic contrast-transfer efficiency to demonstrate that, at low contrast, the elastogram may be interpreted as a quantitative image of the relative Young's modulus distribution.

Animals↗

Characterization of elastographic noise using the envelope of echo signals.

A theoretical formulation characterizing the noise performance of strain estimation using envelope signals is presented for the cross-correlation based strain estimator in elastography, using a modified strain filter approach. The strain filter describes the relationship among the elastographic signal-to-noise ratio (SNRe), sensitivity, contrast-to-noise ratio and dynamic range for a given resolution in the elastogram, as determined by the cross-correlation window length and window overlap. Theoretical results indicate that the envelope strain filter noise performance (SNRe level) is about half that obtained in the ratio frequency (RF) case (fo = 7.5 MHz). Simulation results corroborate the trend predicted using the strain filter. Experimental SNRe vs. strain plots presented in this article illustrate the same trend as the theoretical results. These plots allow a quantitative comparison of the elastograms obtained with RF and envelope signal processing. For small strains, the performance obtained using RF signals is superior to that obtained for envelope signals (since jitter errors are smaller due to the utilization of phase information in RF signals). However, for large tissue strains, envelope analysis provides an accurate estimate of the tissue strain (since envelope signal decorrelation is smaller than RF signal decorrelation at large strains). An algorithm that combines the low-noise characteristics of the cross-correlation analysis using RF signals at small strains and envelope signals for estimation of large tissue strains is proposed to improve the dynamic range in the elastogram.

Algorithms↗

An analysis of elastographic contrast-to-noise ratio.

We present a theoretical formalism and simulation results that allow the incorporation of the elastic contrast properties of tissues with simple geometries into the elastographic noise models developed previously. This analysis results in the computation of the elastographic contrast-to-noise ratio (CNRe). The CNRe in elastography is an important quantity that is related to the detectability of a lesion or inhomogeneity. In this paper, the upper bound on the elastographic CNRe is derived for both a one-dimensional (1-D) and 2-D analytic plane-strain tissue model. The CNRe in the elastogram depends on the contrast-transfer efficiency (CTE) for both the 1-D and 2-D geometries discussed in this paper. The 1-D model is used to characterize layered structures and the 2-D model is derived for circular inclusion within a background of uniform elasticity. A previously derived classical analytic solution of the elasticity equations, for a circular inclusion embedded in an infinite medium and subjected to a uniaxial compression, is used to compute the upper bound of the CNRe. Monte Carlo simulations illustrate the close correspondence between the theoretical and simulation results.

Elasticity↗

Elastographic imaging of thermal lesions in soft tissue: a preliminary study in vitro.

The use of elastography for the visualization of thermal lesions in biological soft tissue in vitro was investigated. Thermal lesions were created in samples of postmortem ovine kidney using a surgical neodymium: YAG (Nd:YAG) laser. The kidney samples were cast in gel, and elastographic images of the lesions were constructed using sonographic information and external markers to locate the region of interest. Gross pathology of the kidney samples confirmed the dimensions of the lesions. Good correlation between the lesion length along the laser fiber axis and maximum diameter measured off of the fiber axis determined from elastographic images and gross pathology photographs was found.

Animals↗

Limits on the contrast of strain concentrations in elastography.

Using an analytic solution of the elasticity equation derived for a cylindrical inclusion, it is shown that the contrast of the strain concentrations is limited for both hard and soft lesions. This means that, beyond a given elastic modulus contrast, the strain concentrations remain virtually constant.

Artifacts↗

A new elastographic method for estimation and imaging of lateral displacements, lateral strains, corrected axial strains and Poisson's ratios in tissues.

A major disadvantage of the current practice of elastography is that only the axial component of the strain is estimated. The lateral and elevational components are basically disregarded, yet they corrupt the axial strain estimation by inducing decorrelation noise. In this paper, we describe a new weighted interpolation method operating between neighboring RF A-lines for high precision tracking of the lateral displacement. Due to this high lateral-tracking precision, quality lateral elastograms are generated that display the lateral component of the strain tensor. These precision lateral-displacement estimates allow a fine correction for the lateral decorrelation that corrupts the axial estimation. Finally, by dividing the lateral elastogram by the axial elastogram, we are able to produce a new image that displays the distribution of Poisson's ratios in the tissue. Results are presented from finite-element simulations and phantoms as well as in vitro and in vivo experiments.

Blood Flow Velocity↗