Search PubMed⌕ Search

Biomedical subjects

J N Petersen

Publications and source records attributed to J N Petersen.

11 recordsLinked to original sources

Dissimilatory reduction of Cr(VI), Fe(III), and U(VI) by Cellulomonas isolates.

The reduction of Cr(VI), Fe(III), and U(VI) was studied using three recently isolated environmental Cellulomonas sp. (WS01, WS18, and ES5) and a known Cellulomonas strain ( Cellulomonas flavigena ATCC 482) under anaerobic, non-growth conditions. In all cases, these cultures were observed to reduce Cr(VI), Fe(III), and U(VI). In 100 h, with lactate as electron donor, the Cellulomonas isolates (500 mg/l total cell protein) reduced nitrilotriacetic acid chelated Fe(III) [Fe(III)-NTA] from 5 mM to less than 2.2 mM, Cr(VI) from 0.2 mM to less than 0.001 mM, and U(VI) from 0.2 mM to less than 0.12 mM. All Cellulomonas isolates also reduced Cr(VI), Fe(III), and U(VI) in the absence of lactate, while no metal reduction was observed in either the cell-free or heat-killed cell controls. This is the first report of Cellulomonas sp. reducing Fe(III) and U(VI). Further, this is the first report of Cellulomonas spp. coupling the oxidation of lactate, or other unknown electron donors in the absence of lactate, to the reduction of Cr(VI), Fe(III), and U(VI).

Anaerobiosis↗

Cytotoxic potential of industrial strains of Bacillus sp.

The cytotoxic potential of selected strains of Bacillus licheniformis, Bacillus amyloliquefaciens, and Bacillus subtilis, used in the production of industrial enzyme products, has been assessed. Cytotoxicity was determined in Chinese hamster ovary (CHO-K1) cells by measuring total cellular metabolic activity using the tetrazolium salt 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). Initially the MTT assay was validated against toxigenic strains of Bacillus cereus, to define the exact criteria for a toxigenic versus a nontoxigenic response. The assay proved sensitive to culture broths of both a diarrheagenic strain and an emetic strain of B. cereus. The enzyme-producing strains tested were nontoxic to CHO-K1 cells. Additionally it was demonstrated that our industrial strains did not react with antibodies against B. cereus enterotoxins by use of commercial antibody-based kits from Oxoid and Tecra. A short survey of the literature concerning the toxigenic potential of species within the subtilis group is included, as is a database search of known B. cereus enterotoxins against B. subtilis and B. licheniformis DNA sequences.

Animals↗

Nitrate reduction with Halomonas campisalis. Kinetics of denitrification at pH 9 and 12.5% NaCl.

Regeneration of ion exchange resins with NaCl produces brine containing high concentrations of nitrate that can be difficult to remove using standard biological, physical, or chemical technologies. In this study. Halomonas campisalis (ATCC #700597) (Mormile et al., 1999) was shown to completely reduce nitrate at 125 g/L NaCl and pH 9. This organism was also used in experiments to determine nitrate-reduction rates and biomass yields. Kinetic parameters were measured separately with glycerol, lactate. acetate, ethanol, and methanol. The specific nitrate-reduction rate coefficient was highest in cultures amended with acetate, while lactate and glycerol (a natural osmoticum in hypersaline environments) had lower reduction rates. No evidence of nitrate reduction was observed when ethanol or methanol was provided as an electron donor. Kinetic modeling provided values for nitrate and nitrite-reduction rate coefficients and for biomass yields. Measured rates and yields were similar to reported parameters obtained from non-halophilic nitrate-reducing cultures under low salt concentrations. Therefore, for highly saline solutions, the use of halophiles to selectively remove nitrate from these brines may represent a viable treatment option.

Halomonas↗

Successive identification of biodegradation rates for multiple sequentially reactive contaminants in groundwater.

At the field scale, the biodegradation rate is usually estimated from analytical solutions to single species transport with first-order reactions, using measured data as input. Because many contaminants, e.g., chlorinated solvents, are degraded in a sequential pattern, with degradation products further reacting to produce new species, it is of great interest to quantify the transformation rate of every reaction. The conventional inverse solutions for identifying the transformation rates are limited to single species problems. In the present study, we propose a successive optimization approach to identify the biodegradation rate for each species by using a previously developed analytical solution to multi-species first-order reactive transport using data obtained at the field scale. By specifying a link between analytical solutions to sequentially reactive transport problems and optimization methods and assuming constant transport parameters (velocity, dispersivities, and retardation factors), the first-order transformation rates are optimized successively from parent species to its daughter species.

Biodegradation, Environmental↗

Control and optimization of apheresis procedures in a COBE 2997 cell separator.

To obtain more efficient operation of a COBE Model 2997 clinical cell separator using either a Single Stage II (SS II) or a Dual Stage separation chamber, modifications were made to allow complete computer control. Product cell density was detected using an optical sensor and controlled by automatic feedback through a microcomputer interface. Control was accomplished by automatically adjusting the red blood cell (RBC) and plasma product flow rates using a proportional-integral (PI) algorithm. Results show that, using either chamber, the product cell density can be maintained at a preselected value for extended periods of time without operator intervention. This system allowed investigation of optimal operating regions for plateletpheresis and leukapheresis procedures. The effects of centrifuge rpm and controller set point on centrifuge operation were investigated using a second order factorial experimental design. Theoretical significance of model parameters was assessed with the aid of a hindered settling model and simple reasoning about the interface position relative to the collection port. The results suggest that, in either chamber, the optimum operating region for plateletpheresis procedures occurs at moderate controller set points and high centrifuge rpm. The resultant operating efficiency and product purity values are approximately 63 percent and 0.65 respectively in the SS II chamber and approximately 70 percent and 0.70 respectively in the Dual Chamber. In the SS II, the optimum operating region for leukapheresis procedures occurred at high controller set point values for any centrifuge rpm above 1200 with an operating efficiency near 100 percent. However, in the Dual Chamber, the optimum operating region for leukapheresis procedures occurred at high controller set points and high centrifuge rpm's, again providing an operating efficiency near 100 percent.

Animals↗

The effects of RPM and recycle on separation efficiency in a clinical blood cell centrifuge.

A COBE blood cell centrifuge, model 2997 with a single stage channel, was modified to allow computer controlled sampling, and to allow recycle of red blood cells (RBCs) and plasma streams using bovine whole blood. The effects of recycle of the packed RBC and plasma product streams, and of the centrifuge RPM on platelet and white blood cell (WBC) separation efficiencies were quantified using a central composite factorial experimental design. These data were then fit using second order models. Both the model for the WBC separation efficiency and the model for the platelet separation efficiency predict that RPM has the greatest effect on separation efficiency and that RBC and plasma recycle have detrimental effects at moderate to low RPM, but have negligible impact on separation efficiency at high RPM.

Animals↗

Interface dynamics in a centrifugal cell separator.

Experiments were performed with bovine blood to study the response of the plasma/cell interface position to pumping rate adjustments in two single-stage (SS I and SS II) cell separation chambers. Standard clinical instrumentation and equipment and on-line computer interfacing were used to monitor and control the interface position. The data provided a quantitative description of its dynamics in the SS I and the SS II chambers. In the SS I chamber, adjustments in the flow rate caused the interface to move very slowly and in a complex manner from one steady-state operation position to another. Such behavior made both manual and computer-controlled operation very difficult. By contrast, the SS II chamber was inherently unstable for most operating conditions. We demonstrated, however, that a feedback controller could be used easily to adjust or maintain the interface position, and this system moved from one steady-state operating condition to another 10 times as fast as the system using the SS I chamber. Also, the manner in which the controller allowed the system to respond to operator requests was much simplier than that for the SS I system.

Animals↗