Search PubMed⌕ Search

Biomedical subjects

J N Lucas

Publications and source records attributed to J N Lucas.

47 records · Page 3Linked to original sources

Rapid translocation frequency analysis in humans decades after exposure to ionizing radiation.

This paper presents an analysis of the utility of fluorescence in situ hybridization (FISH) with whole-chromosome probes for measurement of the genomic frequency of translocations found in the peripheral blood of individuals exposed to ionizing radiation. First, we derive the equation: Fp = 2.05fp(1-fp)FG, relating the translocation frequency, Fp, measured using FISH to the genomic translocation frequency, FG, where fp is the fraction of the genome covered by the composite probe. We demonstrate the validity of this equation by showing that: (a) translocation detection efficiency predicted by the equation is consistent with experimental data as fp is changed; (b) translocation frequency dose-response curves measured in vitro using FISH agree well with dicentric frequency dose-response curves measured in vitro using conventional cytogenetic procedures; and (c) the genomic translocation frequencies estimated from FISH measurements for 20 Hiroshima A-bomb survivors and four workers exposed to ionizing radiation during the Y-12 criticality accident are approximately the same as the translocation frequencies measured using G-banding. We also show that translocation frequency dose response curves estimated using FISH are similar for Hiroshima A-bomb survivors and for first division lymphocytes irradiated in vitro. We conclude with a discussion of the potential utility of translocation frequency analysis for assessment of the level of acute radiation exposure independent of the time between analysis and exposure.

Accidents↗

Biodosimetry for a radiation worker using multiple assays.

Four state-of-the-art biodosimeters--GPA mutations, chromosome translocations, micronuclei, and dicentrics--were used to evaluate a radiation worker who believed that the official dosimetry records substantially underestimated his actual dose. Dosimetry records indicated that the worker received 0.56 Sv during a 36-y employment history, always within the dose limits. In contrast, the worker believed that his dose equivalent may have been more than 2.5 Sv because much of the exposure was received during the early days of health physics when dosimetry capabilities and practices were not as good as they are today. Because there are no biodosimetric assays that have been fully validated for the long-term low-level exposures received by the worker, we did not expect to obtain particularly useful point-estimates of dose. However, because the discrepancy between the dosimetry records and the worker's belief was so large, we believed that biodosimetry using multiple assays together with probabilistic assessment of the uncertainties would provide useful insight. Results showed that the frequencies of chromosome translocations and GPA mutations (stable biodosimeters) were significantly elevated when compared with those for unexposed controls. Our analysis suggests that dose-equivalent estimates in the approximately 0.4 to approximately 2 Sv range (which include the value in the dosimetry records) cannot be confidently excluded at this time based on biodosimetry; however, a value greater than 2.5 Sv appears unlikely. Important new information on the temporal stability of chromosome translocations is also presented.

Chromosome Aberrations↗

Dicentric chromosome frequency analysis using slit-scan flow cytometry.

Slit-scan flow cytometry (SSFCM) was used to quantify the frequency of dicentric chromosomes in human lymphoblastoid cells following gamma irradiation. In this study, cultured human cells were irradiated with 0, 0.25, 0.5, 1.0, and 2.0 Gy of 0.66 MeV gamma-rays, cultured for an additional 11 h, and treated for 5 h with colcemid. Chromosomes were then isolated, stained with propidium iodide, and analyzed using SSFCM for total fluorescence and slit-scan profile. The frequency of chromosomes having DNA contents greater than once and less than twice the DNA content of the number 1 chromosome and producing trimodal profiles was determined at each dose. This frequency was used as an estimate of the relative dicentric chromosome frequency at that dose. The estimated dicentric chromosome frequency per cell, f(D), increased with dose, D, in a linear-quadratic manner according to the relation f(D) = 4.52 x 10(-5) + 5.72 x 10(-5) D + 1.19 x 10(-4) D2.

Algorithms↗

Two-color hybridization with high complexity chromosome-specific probes and a degenerate alpha satellite probe DNA allows unambiguous discrimination between symmetrical and asymmetrical translocations.

This report describes a fluorescence in situ hybridization approach to chromosome staining that facilitates detection of structural aberrations and allows discrimination between dicentric chromosomes and symmetrically translocated chromosomes. In this approach, selected whole chromosomes are stained in one color by hybridization with composite probes whose elements have DNA sequence homology along the length of the target chromosomes. In addition, all chromosomes are counterstained with a DNA specific dye so that structural aberrations between target and non-target chromosomes are clearly visible. Discrimination between dicentric chromosomes and symmetrical translocations is accomplished by hybridization with a second probe that is homologous to DNA sequences found in the centromeric region of all chromosomes. The centromeric marker is visualized in a different color, so that the number of centromeres per aberrant chromosome can be rapidly determined in the microscope by changing excitation and fluorescence filters.

Base Sequence↗

Serious leg injuries in motorcycle despatch riders. An unacceptable occupational hazard?

In the 3 years up to the end of 1988, 18 of the 46 patients admitted with lower limb fractures following a motorcycle accident were despatch riders. Ten of the despatch riders were injured in the final year of the study. The nature of the injuries sustained, the reasons for their apparent frequent incidence and possible preventive measures are discussed.

Accidents, Traffic↗

Rapid human chromosome aberration analysis using fluorescence in situ hybridization.

We have used in situ hybridization of repeat-sequence DNA probes, specific to the paracentromric locus 1q12 and the telomeric locus 1p36, to fluorescently stain regions that flank human chromosome 1p. This procedure was used for fast detection of structural aberrations involving human chromosome 1p in two separate experiments. In one, human lymphocytes were irradiated with 0, 0.8, 1.6, 2.4 and 3.2 Gy of 137Cs gamma-rays. In the other, human lymphocytes were irradiated with 0, 0.09, 0.18, 2.0, 3.1 and 4.1 Gy of 60Co gamma-rays. The frequencies (per cell) of translocations and dicentrics with one breakpoint in 1p and one elsewhere in the genome were determined for cells irradiated at each dose point. These frequencies both increased with dose, D, in a linear-quadratic manner. The delta, alpha, and beta coefficients resulting from a fit of the equation f(D)=delta + alphaD + betaD2 to the translocation frequency dose-response data were 0.0025, 0.0027 and 0.0037 for 137Cs gamma-rays, and 0.0010, 0.0041, and 0.0057 for 60Co gamma-rays. The delta, alpha, and beta coefficients resulting from a fit to the dicentric frequency dose-response data were 0.0005, 0.0010 and 0.0028 for 137Cs gamma-rays and 0.0001, 0.0002 and 0.0035, for 60Co gamma-rays. Approximately 32,000 metaphase spreads were scored in this study. The average analysis rate was over two metaphase spreads per minute. However, an experienced analyst was able to find and score one metaphase spread every 10s. The importance of this new cytogenetic analysis technique for biological dosimetry and in vivo risk assessment is discussed.

Cesium Radioisotopes↗

Centromeric index versus DNA content flow karyotypes of human chromosomes measured by means of slit-scan flow cytometry.

We have applied slit-scan flow cytometry (SSFCM) to classify human chromosomes according to their centromeric index (CI) and relative DNA content. The resulting bivariate--CI vs. DNA content--distributions shows 14 peaks for normal human chromosomes. Distinct peaks are produced by chromosomes 1, 2, 3, 4 + 5, 6 + 7 + X, 8, 13 + 14 + 15, 16, 17 + 18, 19 + 20, and 21 + 22 + Y. In addition, chromosomes 9 through 12 are resolved into three peaks. The identity of the chromosomes comprising each peak was determined by comparing CI vs. DNA content distributions measured for normal human chromosomes by means of SSFCM with CI and DNA content values measured for human chromosomes with image analysis. The accuracy of CI measurement by SSFCM was verified by measuring CIs for human chromosomes isolated from human/rodent hybrid cell lines containing only a few known human chromosomes. These studies showed CIs measured for human chromosomes 1-19 and 21 to be in close agreement with the CIs calculated by means of image analysis. We further confirmed the chromosome assignments for each peak by showing that the relative volumes of the peaks in the CI vs. DNA content distributions for chromosomes from normal cells are similar to the relative frequencies of chromosomes expected for these peaks based on the peak assignments.

Animals↗

Orientation measurements of microsphere doublets and metaphase chromosomes in flow.

Obtaining information about the shape of particles from slit-scan profiles is facilitated if the particles are oriented. Elongated particles orient in the nozzle of flow cytometers, but orientation may be disrupted before the particles get to the point of measurement. We have used our slit-scan flow cytometer to investigate the orientation of microsphere doublets in a liquid jet in air, in flow across a glass surface, and in a 200-microns-square capillary tube as a function of distance from the flow chamber nozzle. Particles were classified as being oriented if there was a centrally located dip in the slit-scan profile. Essentially all the doublets in the jet were oriented, and no disorientation was noted over the distances measured (up to 10 mm from the nozzle). Particle orientation was maintained for 80 microns in flow across a glass surface. In the capillary-type flow chamber, essentially all of the particles were oriented at the tube entrance and for several millimeters into the tube. There then occurred a region where particle tumbling started and progressively fewer doublets met the orientation criteria. The distance to where tumbling began could be estimated by calculating the length required to establish the parabolic flow profile in the tube. Finally, the fraction of oriented particles reached a constant value that did not change with increased distance into the tube. When sample was injected off axis (i.e., halfway between the chamber center and the chamber walls), particle tumbling began closer to the tube entrance.(ABSTRACT TRUNCATED AT 250 WORDS)

Cell Line↗

Centromeric index measurement by slit-scan flow cytometry.

We report here the application of slit-scan flow cytometry (SSFCM) in the classification of muntjac, Chinese hamster, and human chromosomes according to centromeric index (CI) and total fluorescence. Chromosomes were isolated from mitotic cells, stained with propidium iodide and processed through the SSFCM where fluorescence profiles were measured. The centromere for each profile was taken as the point of maximum difference between the measured profile and a standard profile having no centromeric dip. The areas under the profile on either side of the centromere were then calculated and the CI was calculated as the ratio of the larger area to the total area under the profile. Relative DNA contents for each chromosome were taken to be proportional to the total fluorescence. Mean CI's for muntjac chromosomes 1, 2, and X + 3 were 0.52, 0.88, and 0.73, respectively; CI's for Chinese hamster M3-1 chromosomes 1, 2, 5, 8, and M2 were 0.53, 0.55, 0.57, 0.77, and 0.86, respectively; and average CI's for chromosome groups 4 + t (X;5), 6 + 7 + Y, 9 + M1, and 10 + 11 were 0.56, 0.82, 0.58, and 0.60, respectively. These results were, on average, within 4.4% of CI measurements made by image cytometry. CI's measured for human chromosomes 9 through 12, were, on average, within 2.0% of those made by image cytometry.

Animals↗