Search PubMed⌕ Search

Biomedical subjects

J Meyer

Publications and source records attributed to J Meyer.

At least 325 records · Page 18Linked to original sources

[Local drug delivery and gene therapy].

One of the most important problems in clinical cardiology is still unresolved, i.e., the development of a restenosis following coronary balloon angioplasty. Our knowledge about the sequelae of pathophysiologic events occurring during neointima formation is still far from complete (Figure 1) and numerous therapeutic trials using systemic administration of drugs with different mechanisms of action have failed. Possible innovative strategies are the local administration of high doses of drugs into the coronary arteries and local gene therapeutic interventions to inhibit neointima formation by reducing the proliferation of vascular smooth muscle cells. Numerous catheter devices were developed (Figure 2) in order to enable the local application of high doses of a drug or DNA. Additionally, galenic techniques are being developed to guarantee a steady release of locally administered drugs, e.g. from drug containing liposomes or microcarriers (Figure 3). There are already several animal models in which the development of a neointima was reduced by injecting antisense oligonucleotides directed towards the RNA encoding cell cycle regulatory proteins or peptides. Alternatively, the transfer of cDNA encoding proteins or protein products which inhibit the cellular proliferation and migration are being tested in vitro and in vivo with the help of reporter genes (Figure 4). Although, gene transfer techniques are believed to offer great therapeutic options for the future, the clinical data available today regarding this method are very limited and are derived from studies in patients with peripheral arterial disease. Thus, it is still questionable if gene transfer techniques will ever be able to become an integral part of our standard treatment for patients with vascular diseases.

Coronary Disease↗

Transduction of antibiotic resistance markers among Actinobacillus actinomycetemcomitans strains by temperate bacteriophages Aa phi 23.

Actinobacillus actinomycetemcomitans (Aa) strain ST1 carries the tetracycline (Tc) resistance transposon Tn916 and the Aa phi ST1 prophage, which is closely related to temperate bacteriophage Aa phi 23. High titre phage preparations were obtained from this strain by mitomycin C induction and were used to transduce the TcR determinant to the TcS recipient strains ZIB1001 and ZIB1015 (MIC 2 micrograms Tc/ml). TcR transductants (MIC > or = 32 micrograms Tc/ml) were detected at frequencies of 3 x 10(-6) to 5 x 10(-8) per pfu. All TcR transductants examined contained the entire Tn916 inserted at several different locations within the Aa genome. They appear to have resulted from generalized transduction. In addition both bacteriophages, Aa phi 23 and Aa phi ST1, were capable of transducing the chloramphenicol (Cm) resistance marker of plasmid pKT210 (transduction frequencies of 2 x 10(-5) to 3 x 10(-7) per pfu) to the recipient strain ZIB1001 (MIC 8 micrograms Cm/ml). Eleven CmR ZIB1001 transductants (MIC > or = 100 micrograms Cm/ml) studied carried a plasmid indistinguishable from pKT210 by restriction analyses. In view of the high prevalence of this phage family, and the increasing use of tetracycline in periodontitis therapy, these findings may have clinical importance.

Aggregatibacter actinomycetemcomitans↗

Nitric oxide synthase inhibition by L-NAME in leukocytopenic patients with severe septic shock.

OBJECTIVES: To investigate the effects of nitric oxide synthase inhibition by NG-nitro-L-arginine methyl ester (L-NAME) on hemodynamics and outcome in leukocytopenic (< 1000/microliter) patients with severe septic shock requiring strong vasopressor support. DESIGN: Prospective clinical study. SETTING: Medical intensive care unit. PATIENTS: 10 patients with hematologic malignancies in chemotherapy-induced leukocytopenia with severe septic shock and high-dose vasopressor requirement. INTERVENTION: Continuous intravenous infusion of L-NAME (0.3 mg/ kg per hour) for a study period of 24 h with prolongation for up to 96 h according to individual requirements. MEASUREMENTS AND RESULTS: Compared to baseline values, an increase in mean arterial pressure (p = 0.0021), systemic vascular resistance (p = 0.0001), and left ventricular stroke work index (p = 0.023) with a concomitant decrease in vasopressor requirement (p < 0.05) was observed during the first 24 h of L-NAME treatment. Cardiac output data were unchanged during the study period (p = 0.49). L-NAME was tapered off in five patients who again became responsive to vasopressor medication. Two patients survived the episode of septic shock and vasoactive medication was stopped. CONCLUSIONS: The data demonstrate that inhibition of nitric oxide synthase may be beneficial for the treatment of severe septic shock in leukocytopenic patients as indicated by an increase in systemic vascular resistance, mean arterial pressure, and left ventricular stroke work index.

Adult↗

[Effect of qualitative stenosis characteristics on the quality of measurements of various QCA systems].

Reproducibility and accuracy of in vitro measurements are very high using recently developed QCA systems. We analyzed the impact of lesion characteristics ad the image quality on the quality of measurements under clinical conditions. For the study we selected 57 coronary artery lesions which had a clinically relevant distribution for stenosis severity, lesion characteristics, and image quality. Every effort was made to eliminate procedural sources of error. Three investigators measured each lesion five times with each of three QCA systems (AWOS, Cardio and CMS). Only the measurements of the minimal stenosis diameter were analyzed. The precision of all the measurements was high with the AWOS (0.04 mm), the Cardio (0.05 mm), and the CMS systems (0.06 mm). Variability of measurements increased for the following criteria: Ambrose-III morphology (CMS 0.082 mm), surface irregularities (Cardio 0.069 mm, CMS 0.073 mm), TIMI I (Cardio 0.084 mm, CMS 0.0121 mm), and moderate image quality (CMS 0.07 mm). There were no differences in the precision of the measurements in the other groups of lesion characteristics. There were no relevant differences in any of the measurements between the systems (AWOS-Cardio -0.07 mm, AWOS-CMS-0.11 mm, Cardio-CMS-0.04 mm). Smaller diameters were measured with the AWOS system than with the CMS and the Cardio systems when the lesion was calcified (AWOS-Cardio-0.109 mm, AWOS-CMS-0.161 mm). This was only a trend, however, and did not reach statistical significance, which was also true for the other differences found between the systems according to various lesion characteristics. In summary, we found that the measurement quality of the QCA systems used in this study is not altered by the underlying lesion characteristics or the image quality.

Coronary Angiography↗

[Intraventricular obstructions in dobutamine stress echocardiography: determinants of their development and clinical sequelae].

UNLABELLED: Dobutamine stress echocardiography (DSE) leads to strong hypercontraction, tachycardia, and peripheral vasodilatation. In previous studies systolic obstruction of the left ventricular outflow tract (LVOT) was observed as a result of these factors. To evaluate left ventricular function and morphology in patients (pts) with induced systolic LVOT obstruction, we used continuous wave (CW) doppler registrations in combination with quantitative 2-D-echocardiography in 100 pts during routinely performed DSE (5-40 micrograms/kg/min). In addition left ventricular wall thickness was measured. Symptoms were registered using a standardised questionnaire and cardiac arrhythmias were counted over a two minute interval at rest and during the maximal heart rate of each patient. During DSE dynamic flow acceleration with late systolic peak velocity above 2 m/second (s) was considered to represent LVOT obstruction in pts with normal flow profiles in the LVOT before infusion of dobutamine. For invasive studies pts were investigated with femoral catheterisation by the method of Judkins. A greater than 50% stenosis was judged to be significant. RESULTS: Examinations in 73 pts provided data of sufficient quality for echocardiographic and Doppler sonographic evaluations. 39 pts, 26 men, 13 women, mean age 64 +/- 8 years, developed late systolic flow velocities above 2 m/s and therefore formed the obstructive group (grp A). Grp B consisted of 34 pts, 26 men and 8 women, mean age 66 +/- 10 years, who showed normal time velocity integrals during DSE. In 41 pts invasive data provided information concerning the existence and severity of coronary artery disease. There were no significant differences in the increase of heart rate, the product of maximal systolic blood pressure and maximal heart rate or the percentage of pts, who reached their age corrected submaximal heart rate during DSE. Obstructive pts (group A) showed late systolic dynamic acceleration of systolic flow with a mean maximal speed of 315.4 +/- 139.8 cm/s, which peaked 0.12 +/- 0.04 s after the R-wave. From the velocities we calculated a mean pressure gradient of 47.5 +/- 39.7 mm Hg using the modified Bernoulli equation. Group B patients showed lower and earlier maximal speeds with a mean value of 158.2 +/- 37.6 cm/s, 0.09 +/- 0.04 s after the R-wave, corresponding to a pressure gradient of 10.6 +/- 4.9 mm Hg (p < 0.001). Ejection fractions were higher (p < 0.001) before the test in grp A: 68.2 +/- 8% compared to 55.7 +/- 10.4% in B. This difference increased during peak stress: 74.1 +/- 7.7% compared to 59.5 +/- 12.8%. End diastolic (EDVI) and end systolic volume indexes (ESVI) were lower in grp A (p < 0.001). During DSE, the decrease in ESVI was somewhat stronger for pts in grp A. Left ventricular hypertrophy was more often seen with obstruction. Septal thickness was increased in A: 1.45 +/- 0.34 cm compared to 1.13 +/- 0.27 cm in B (p < 0.001). Left ventricular posterior wall measured 1.03 +/- 0.28 cm in A and 0.83 +/- 0.23 cm in B (p < 0.01). 27 pts in grp B and only 9 in grp A had a history of previous myocardial infarction. Showing no difference at rest, wall motion score indexes raised under DSE in both groups and developed significantly higher scores in grp B at peak stress: 1.30 (1.0-1.90) compared to 1.18 (1.0-1.75) in A. We observed typical chest pain more often in grp B. Unspecific symptoms and arrhythmogenic complications were not statistically different, with the exception of ventricular bigeminy which was more often observed in grp B. A decline in the diastolic blood pressure was observed in pts with very severe obstruction (> 3.5 m/s, p < 0.05). Sensitivity of DSE was 84%, specificity 79%. No significant differences between pts with and without obstruction were observed. SUMMARY: Intraventricular obstructions during DSE are often observed in pts with normal systolic function at rest and during peak stress, especially in the case of left ventricular hypertrophy. (ABSTRACT TRU

Blood Flow Velocity↗

[Quantitative effect of a standardized pressure bandage on arterial and venous circulation in the lower extremities after heart catheter examination].

AIM: The aim of the study was to evaluate the effect of a conventional pressure dressing on arterial and venous blood flow of the legs after cardiac catheterization. METHODS: Duplexsonographic measurements were performed of both legs in 100 consecutive patients before catheterization and with a pressure dressing after the procedure. The pressure dressing was applied by means of a pressure pad on the punctured leg, so that the ankle-arm-index (blood pressure at the leg/blood pressure at the arm) was not influenced. Arterial and venous blood flow of the superficial femoral artery and vein were registered. We evaluated both legs by means of duplex sonography to detect arterial or venous complications after cardiac catheterization. Statistical evaluation was performed using the 1-sample Wilcoxon test. RESULTS: There was a significant reduction of venous blood flow in the punctured leg from a mean of 119 ml/min before puncture to 84 ml/min during pressure dressing (29% flow reduction, p < 0.01), and a reduction of arterial blood flow from a mean of 132 ml/min before puncture to 84 ml/min during pressure dressing (36% flow reduction, p < 0.01). In the contralateral leg, venous blood flow was reduced from about 118 ml/min to 96 ml/min during pressure dressing (19% flow reduction, p < 0.01), and arterial blood flow was reduced from about 129 ml/min to 93 ml/min during pressure dressing (28% flow reduction, p < 0.01). There were no venous complications, 5 patients suffered false aneurysm (5%), and one patient had an arteriovenous fistula (1%). CONCLUSION: A conventional pressure dressing caused a significant reduction of arterial as well as venous blood flow of both the punctured leg and the contralateral leg. This is of clinical relevance especially in patients with known peripheral arterial disease or patients at risk for deep venous thrombosis.

Adult↗

[Reversibility of changes in left and right ventricular geometry and hemodynamics in pulmonary hypertension. Echocardiographic characteristics before and after pulmonary thromboendarterectomy].

Pulmonary thromboendarterectomy (PTE) leads to an acute decrease of right ventricular (RV) afterload in patients with chronic thromboembolic pulmonary hypertension. We investigated the changes in right and left ventricular (LV) geometry and hemodynamics by means of transthoracic echocardiography. The prospective study was performed in 14 patients (8 female, 6 male; age 55 +/- 20 years) before and 18 +/- 12 days after PTE. Total pulmonary vascular resistance and systolic pulmonary artery pressure were significantly decreased (PVR: preoperative 986 +/- 318, postoperative 323 +/- 280 dyn x s/cm5, p < 0.05; PAP preoperative 71 +/- 40, postoperative 41 +/- 40 mm Hg + right atrial pressure, p < 0.05). End diastolic and end systolic RV area decreased from 33 +/- 12 to 23 +/- 8 cm2, respectively, from 26 +/- 10 to 16 +/- 6 cm2, p < 0.05. There was an increase in systolic RV fractional area change from 20 +/- 12 to 30 +/- 16%, p < 0.05. RV systolic pressure rise remained unchanged (516 +/- 166 vs. 556 +/- 128 mm Hg/sec). LV ejection fraction remained within normal ranges (64 +/- 16 vs. 62 +/- 12%). Echocardiographically determined cardiac index increased from 2.8 +/- 0.74 to 4.1 +/- 1.74 l/min/m2. A decrease in LV excentricity indices (end diastolic: 1.9 +/- 1 vs. 1.1 +/- 0.3, end systolic: 1.7 +/- 0.6 vs. 1.1 +/- 0.4, p < 0.05) proved a normalization of preoperatively altered septum motion. LV diastolic filling returned to normal limits: (E/A ratio: 0.62 +/- 0.34 vs. 1.3 +/- 0.8; p < 0.05); Peak E velocity: 0.51 +/- 0.34 vs. 0.88 +/- 0.28 m/sec, p < 0.05; Peak A velocity: 0.81 +/- 0.36 vs. 0.72 +/- 0.42 m/sec, ns; E deceleration velocity: 299 +/- 328 vs. 582 +/- 294 cm/sec2, p < 0.05; Isovolumic relaxation time: 134 +/- 40 vs. 83 +/- 38 m/sec, p < 0.05). We could show a marked decrease in RV afterload shortly after PTE with a profound recovery of right ventricular systolic function--even in case of severe pulmonary hypertension. A decrease in paradoxic motion of the interventricular septum and normalization of LV diastolic filling pattern resulted in a significant increase of cardiac index.

Aged↗

[Follow-up of patients with chronic aortic valve insufficiency with ACE inhibitor therapy].

Long-term treatment with ACE-inhibitors improves left ventricular function in patients with aortic regurgitation. But how does this advantage influence capacity? Using echocardiography and spiroergometry, we investigated 13 patients before and after a 3 month treatment with cilazapril (2.5-5 mg/d). Ventricular enddiastolic diameter-index decreased from 3.5 to 3.1 cm/m2 (p = 0.005), left ventricular endsystolic diameter-index from 2.3 to 2.0 cm/m2 (p = 0.005), and wallstress from 174 to 150 dyn/cm2 (p = 0.01). Left ventricular mass was reduced by 14% to 488 g (= 253 g/m2, p < 0.05). The regurgitant jet area decreased from 10.1 to 8.1 cm2 (p < 0.05). Wall thickness, workload, and maximal oxygen intake showed no significant difference during follow-up. These results indicate that left ventricular volumes and muscle mass in patients with aortic regurgitation are positively influenced by long term ACE-inhibition, which preserves exercise capacity.

Adolescent↗

Effects of sympathetic nerve blockade on vasoconstrictive properties of nitric oxide synthase inhibition in sheep.

OBJECTIVE: Inhibition of nitric oxide synthase causes intense vasoconstriction. This effect is thought to be dependent on sympathetic nerve activity. Thus, we investigated the vasoconstrictive effects of the nitric oxide synthase inhibitor NG-nitro-L-arginine methyl ester (L-NAME) in sheep, in which a reversible sympathetic block was established by thoracic epidural anesthesia. METHODS: Sheep (n = 11) were surgically prepared for chronic study. After at least 5 days of recovery, L-NAME was continuously administered and hemodynamics were monitored. This was done in sheep with and without sympathetic blockade in randomized order. RESULTS: The vasoconstrictive effects of L-NAME were similar in sheep with and without sympathetic blockade. CONCLUSION: The obtained results suggest that the vasoconstrictive properties of nitric oxide synthase inhibitors are independent of sympathetic tone.

Anesthesia, Epidural↗

Cortisol and estradiol: nongenetic factors for hyperhomocyst(e)inemia.

A low plasma homocyst(e)ine concentration in premenopausal and pregnant women compared with postmenopausal women and men suggests that steroid hormones are nongenetic factors affecting homocysteine metabolism. This hypothesis was tested by determining plasma homocyst(e)ine levels in adult male rats treated with cortisol, estradiol, or a combination of both. Mean plasma homocyst(e)ine concentrations were 3.71 +/- 0.71, 5.26 +/- 1.76, and 4.28 +/- 0.84 nmol/mL in cortisol-treated, estradiol-treated, and cortisol plus estradiol-treated groups, respectively. These values were substantially low compared with the level of 7.32 +/- 0.89 nmol/mL plasma homocyst(e)ine in the control group, indicating a significant effect of steroid hormones on homocysteine metabolism.

Amino Acids↗

Prospective evaluation of fine needle aspiration of small, solid renal masses: accuracy and morbidity.

OBJECTIVES: To determine the accuracy and clinical utility of fine needle aspiration (FNA) of small, solid renal masses. METHODS: A total of 25 patients with small (less than 5.0 cm), solid, clinically localized renal masses were prospectively identified and evaluated with computed tomography guided FNA with analysis for presence of malignant cells and determination of nuclear grade. The final pathologic findings were used for comparison in each case. All patients had renal cell carcinoma and were managed with radical or partial nephrectomy; 3 had low-grade lesions (Fuhrman's grade 1/4), 2 had high-grade lesions (Fuhrman's grade 4/4), and all other patients had intermediate-grade lesions (Fuhrman's grade 2/4 or 3/4) on final histopathologic assessment. RESULTS: Overall, 10 aspirations yielded diagnostic malignant cells, and 9 were read as rare as rare atypical cells suspicious for malignancy. The remainder were negative (n = 6). Correlation with final nuclear grade was observed in eight instances and discordance in two instances. Subcapsular hematomas were observed at the time of surgery in 10 patients, but in no instance was the operation adversely affected. CONCLUSIONS: The diagnostic yield of FNA of small, solid renal masses appears to be too low to justify the potential morbidity of the procedure.

Biopsy, Needle↗

Preliminary immunohistochemical characterization of a monoclonal antibody (PRO:4-216) prepared from human prostate cancer nuclear matrix proteins.

OBJECTIVES: A nuclear matrix protein (PC-1) was previously identified and reported to be present only in human prostate cancer but absent in tissue from the same prostate containing either benign prostatic hyperplasia (BPH) or normal prostate tissue. The PC-1 protein was identified by high resolution two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) and exhibited a molecular mass of 56 kDa and an isoelectric point of 6.58. This work investigates the immunohistochemical characterization of PRO:4-216, a monoclonal antibody to PC-1. METHODS: Areas of the 2D-PAGE gels containing the human prostate cancer nuclear matrix proteins near PC-1 were isolated, eluted, and injected into mice to develop monoclonal antibodies. Antibodies were screened by immunofluorescence for nuclear reactivity to a human prostate cancer cell line (LnCaP) and by 1D and 2D Western blots for reactivity with prostate cancer nuclear matrix proteins. Monoclonal antibodies from the selected clones were affinity purified. The monoclonal antibody PRO:4-216 was used to analyze frozen tissue from 20 cancerous, 22 BPH, and 22 normal regions from fresh human prostate specimens. Tissue sections were analyzed for their immunohistochemical (IHC) (horseradish peroxidase) staining. RESULTS: Using a reference value for positive staining at an IHC score of greater than 50, 85% (17 of 20) of the cancerous, 5% (1 of 22) of the BPH, and 9% (2 of 22) of the normal prostate tissues stained positive. The one BPH and two normal tissues that stained positive were taken from prostates in which the adjacent cancerous tissue also demonstrated high IHC scores (greater than 225). CONCLUSIONS: These data demonstrate nuclear reactivity on fresh frozen human prostate cancer tissue for the monoclonal antibody PRO:4-216. PRO:4-216 may aid in distinguishing normal prostate and BPH from cancerous tissue.

Animals↗

Dobutamine stress Doppler echocardiography: reproducibility and physiologic left ventricular filling patterns.

Qualitatively, dobutamine stress echocardiography has become an established procedure. Quantitative results are in great demand but this is still difficult due to limited endo- and epicardial border definition. Transmitral Doppler variables are strictly quantitative and less subjective. Furthermore, ischemic alterations precede systolic ones (ischemic cascade). There are preliminary reports of the utility of dobutamine stress Doppler echocardiography, but proof of reproducibility and left ventricular filling patterns are still lacking. Fourteen healthy volunteers (10 men, 4 women, median age 25.9 years, range 21-32 years) were investigated according to the usual dobutamine stress echocardiographic protocol (5, 10, 15, 20, 30, 40 and 40 micrograms/kg/min + 0.5 mg atropine). At each titration step a standardized transmitral PW-Doppler recording with the sample volume positioned at the opened mitral leaflet tips was analyzed three times by two independent, experienced investigators. Of the early, late, and mean velocities (VmaxE, VmaxA, Vmean), time integrals (VTI-E, VTI-A, VTI), their ratios (E/A, E/A VTI), and various time intervals (Tacc, Tdec, E- and A-duration, FillT), VmaxE (0.82 to 1.09 m/s; P < 0.0001), VTI-E (16.17 to 17.19 cm; P < 0.0001) and Vmean (0.29 to 0.82 m/s; P < 0.0001) were found to have the greatest discriminatory power, commencing already at a dose of 10-15 micrograms/kg/min dobutamine. VmaxE and VTI-E demonstrated the smallest intra- and interobserver variation without any increase in variability during incremental dose titration. Assessment of the early diastolic filling pattern by Doppler echocardiography is a valuable quantitative and reproducible adjunct to conventional dobutamine stress echocardiography. Further controlled studies in coronary artery disease patients have to confirm, whether lower dobutamine doses could be used in the test and sensitivity increased due to better data acquisition in cases of limited echogenicity, less subjectivity, and earlier onset of ischemic alterations.

Cardiotonic Agents↗

Transthoracic three-dimensional echocardiographic volumetry of distorted left ventricles using rotational scanning.

The purpose of this study was to evaluate the relation of transthoracic three- and two-dimensional echocardiographic left ventricular volumetry to cineventriculographic volumetry. Twenty-five patients with distorted left ventricles were included in the study. To demonstrate the impact of acquiring data by rotational scanning, we performed three- and two-dimensional echocardiography in 36 latex ventricles with data acquisition in different areas of the ultrasound sectors. Interobserver and intraobserver variability were calculated to test for reproducibility. The three-dimensional imaging system consisted of a rotation motor device, a transthoracic 2.5 MHz transducer, a conventional ultrasound unit, and a work-station (TomTec) which provides data acquisition, post-processing, and two- or three-dimensional visualization of digitized data. The transducer moved automatically at 2-degree increments with data acquisition at each tomographic level. The mean investigation time for three-dimensional echocardiography was 21 +/- 6 minutes. In the central near field of the transducer, differences from true volumes in latex ventricles were remarkably smaller for three-dimensional compared with two-dimensional echocardiography (root mean square percent error: three-dimensional echocardiography = 5.3% versus two-dimensional echocardiography = 14.6%). In three-dimensional echocardiography, there was considerable overestimation of volumes in the lateral far field (root mean square percent error = 13.2%) of the ultrasound sector. Differences between two-dimensional echocardiographic human left ventricular volumes and cineventriculography increased with larger volumes. In three-dimensional echocardiography the differences remained constant. Interobserver and intraobserver variability is reduced nearly twofold by three-dimensional echocardiography. Three-dimensional echocardiographic volumetry provides fewer discrepancies to cineventriculography and lesser variability than two-dimensional echocardiography. With the use of rotational scanning, the ventricle has to be positioned in the central near field of the transducer.

Adult↗

Quantitative assessment of aortic stenosis by three-dimensional echocardiography.

The purpose of this study was to assess the feasibility of three-dimensional echocardiography in aortic stenosis. Planimetric determination of valve area and dynamic volume-rendered display were performed. Three-dimensional echocardiography permits display of any desired plane of the cardiac structure. Thus in the case of aortic stenosis, the plane used for planimetric evaluation can be positioned exactly through the valve orifice. Dynamic volume-rendered display may provide a spatial demonstration of the stenotic valve. In 48 patients aortic valve area was measured by planimetry. The three-dimensional data set was acquired by a workstation in the course of a multiplane transesophageal examination. Results were compared with those obtained by multiplane transesophageal two-dimensional planimetric technique and invasive measurement. A dynamic three-dimensional reconstruction was displayed. Planimetric determination of valve area was possible in 42 (88%) of 48 cases. Statistical analysis of the data acquired showed a good agreement between three-dimensional echocardiography and transesophageal echocardiography (mean difference +0.018 cm2; SD = 0.086) and between three-dimensional echocardiography and the invasive technique (mean difference +0.012 cm2; SD = 0.12). Dynamic volume-rendered display was possible in 42 of 48 cases. Three-dimensional echocardiography permits accurate and reliable determination of aortic valve area. Preoperative spatial recognition of the stenotic valve is possible by dynamic volume-rendered display.

Adult↗

Integrating nature and nurture: implications of person-environment correlations and interactions for developmental psychopathology.

The developmental interplay between nature and nurture is discussed, with particular reference to implications for research in developmental psychopathology. The general principles include individual differences in reactivity to the environment, two-way interplay between intraindividual biology and environmental influences, and the need to consider broader social contextual features. Individuals actively process their experiences; they also act on their environment to shape and select their experiences, and individual characteristics change over time. Key findings on genetic effects include their ubiquitous influence, the multifactorial origin of most psychopathology, the involvement of several genes in most mental disorders, some genetic effects operate through dimensional risk features rather than directly on disorder, some genetic effects are dependent on gene-environment correlations and interactions, and genetic effects increase with age. Key findings on environmental effects include their ubiquitous influence, the genetic mediation of some supposed environmental effects, the importance of passive gene-environment correlations, the paucity of evidence regarding environmental effects on lifetime liability to psychopathology, the lack of understanding of environmental effects on the organism, and the importance of nonshared environmental effects. Research strategies to investigate environmental risk mediation include the range of genetically sensitive designs, migration studies, secular trend investigations, studies of nonfamilial environments, and examination of intraindividual change in relation to measured environmental alterations. Proximal processes involved in person-environment interplay are discussed in relation to person-environment interactions and evocative and active person-environment correlations.

Adaptation, Psychological↗

Comparison of QCA systems.

AIMS: Excellent agreement between different 'second generation' systems for quantitative coronary arteriography (QCA) has been found in in vitro measurements. To verify the quality and stability of QCA when used in clinical practice, three QCA systems (AWOS, Cardio, and CMS) were used in a representative set of coronary artery lesions. METHODS AND RESULTS: This set consisted of angiographic stenosis images of 57 patients which varied in stenosis severity and morphology. The process of image acquisition, calibration, and measurement was strictly standardized to eliminate procedural sources of error. Three observers performed QCA five times in each lesion with each QCA system. Interobserver variability was low (Dnorm 0.01-0.05 mm, Dmin 0.01-0.02 mm, %stenosis 0.3-0.7%). Values of system precision were excellent (Dnorm 0.11-0.13 mm, Dmin 0.04-0.06 mm, %stenosis 2.1-2.6%). Comparison of measurements between three QCA systems revealed good agreement (range of mean differences for Dnorm 0.03-0.12 mm, Dmin 0.04-0.11 mm, and %stenosis 0.5-3.6%) and high correlation (corr 0.902-0.977). There was a tendency to measure smaller values for Dmin and consequently to identify more severe stenoses with the AWOS system than with the Cardio and CMS systems. All QCA results were compared to measurements done with the Brown Dodge method to reveal failure of the QCA measurements. These results showed excellent agreement without any systematic deviation (mean differences for Dnorm 0.01-0.08 mm, Dmin 0.02-0.06 mm, and %stenosis 1.3-1.8%). None of the differences were statistically significant. CONCLUSION: We therefore conclude that using the defined version of the AWOS, Cardio, and CMS systems, there is no difference in precision or accuracy when used for QCA of coronary artery lesions.

Algorithms↗