An algorithm for real-time dosimetry in intensity-modulated radiation therapy using the radioluminescence signal from Al2O3:C.

Although the radioluminescence (RL) signal from optical fibre Al(2)O(3):C dosemeters used in medical applications is essentially proportional to dose rate, the crystals used so far are imperfect in the sense that their RL sensitivity changes with accumulated dose. A computational algorithm has been developed that corrects for these sensitivity changes. We further report on a new system that effectively separates the RL signal generated in the crystal from fluorescence and Cerenkov emission generated in the optical fibre cable using a gating technique in connection with pulsed linear accelerator radiation beams. The dosimetry system has been used for dose measurements in a phantom during an intensity-modulated radiation therapy (IMRT) treatment with 6 MV photons. The RL measurement results are in excellent agreement (i.e. within 1%) with both the OSL results and the dose delivered according to the treatment planning system. RL signals from Al(2)O(3):C can be used for real-time dose rate measurements with a time resolution of approximately 0.1 s and a spatial resolution only limited by the size of the detector (<0.5 mm).

Algorithms↗

The influence of RBE variations in a clinical proton treatment plan for a hypopharynx cancer.

Currently, most clinical range-modulated proton beams are assumed to have a fixed overall relative biological effectiveness (RBE) of 1.1. However, it is well known that the RBE increases with depth in the spread-out Bragg peak (SOBP) and becomes about 10% higher than mid-SOBP RBE at 2 mm from the distal edge (Paganetti 2003 Technol. Cancer Res. Treat. 2 413-26) and can reach values of 1.3-1.4 in vitro at the distal edge (Robertson et al 1975 Cancer 35 1664-77, Courdi et al 1994 Br. J. Radiol. 67 800-4). We present a fast method for applying a variable RBE correction with linear energy transfer (LET) dependent tissue-specific parameters based on the alpharef/betaref ratios suitable for implementation in a treatment planning system. The influence of applying this variable RBE correction on a clinical multiple beam proton dose plan is presented here. The treatment plan is evaluated by RBE weighted dose volume histograms (DVHs) and the calculation of tumour control probability (TCP) and normal tissue complication probability (NTCP) values. The variable RBE correction yields DVHs for the clinical target volumes (CTVs), a primary advanced hypopharynx cancer and subclinical disease in the lymph nodes, that are slightly higher than those achieved by multiplying the absorbed dose with RBE=1.1. Although, more importantly, the RBE weighted DVH for an organ at risk, the spinal cord is considerably increased for the variable RBE. As the spinal cord in this particular case is located 8 mm behind the planning target volume (PTV) and hence receives only low total doses, the NTCP values are zero in spite of the significant increase in the RBE weighted DVHs for the variable RBE. However, high NTCP values for the non-target normal tissue were obtained when applying the variable RBE correction. As RBE variations tend to be smaller for in vivo systems, this study-based on in vitro data since human tissue RBE values are scarce and have large uncertainties-can be interpreted as showing the upper limits of the possible effects of utilizing a variable RBE correction. In conclusion, the results obtained here still indicate a significant difference in introducing a variable RBE compared to applying a generic RBE of 1.1, suggesting it is worth considering such a correction in clinical proton therapy planning, especially when risk organs are located immediately behind the target volume.

Carcinoma, Squamous Cell↗

Can the average glandular dose in routine digital mammography screening be reduced? A pilot study using revised image quality criteria.

There is a need for tools that in a simple way can be used for the evaluation of image quality related to clinical requirements in mammography. The aim of this work was to adjust the present European image quality criteria to be relevant also for digital mammography images, and to use as simple and as few criteria as possible. A pilot evaluation of the new set of criteria was made with mammograms of 28 women from a General Electric Senographe 2000D full-field digital mammography system. One breast was exposed using the standard automatic exposure mode, the other using about half of that absorbed dose. Three experienced radiologists evaluated the images using visual grading analysis technique. The results indicate that the new quality criteria can be used for the evaluation of image quality related to clinical requirements in digital mammography in a simple way. The results also suggest that absorbed doses for the mammography system used may be substantially reduced.

Aged↗

A Monte Carlo study of the energy dependence of Al2O3:C crystals for real-time in vivo dosimetry in mammography.

In a previous experimental study, a novel method for in vivo dosimetry has been investigated, based on radioluminescence (RL) and optically stimulated luminescence (OSL). However, because of the large difference in atomic composition between the detector material and the breast tissue, relatively large energy dependence in low-energy X-ray beams can be expected. In the present work, the energy dependence of Al2O3:C crystals was modelled with the Monte Carlo code EGSnrc using three types of X-ray spectra. The results obtained (5.6-7.3%) agree with a previously determined experimental result (9%) within the combined standard uncertainty of the two methods. The influence of the size of the crystal on the energy dependence was investigated together with the effect of varying the thickness of the surrounding light-protective material. The results obtained indicate a minor effect owing to the thickness of the light-protective material, and a somewhat larger effect from reducing the diameter of the crystal. The outcome of this study can be used to improve the future design of the RL/OSL dosimetry system for use in mammography.

Air↗

Clinical evaluation of a new set of image quality criteria for mammography.

The European Commission (EC) quality criteria for screen-film mammography are used as a tool to assess image quality. A new set of criteria was developed and initially tested in a previous study. In the present study, these criteria are further evaluated using screen-film mammograms that have been digitised, manipulated to simulate different image quality levels and reprinted on film. Expert radiologists have evaluated these manipulated images using both the original (EC) and the new criteria. A comparison of three different simulated dose levels reveals that the new criteria yield a larger separation of image criteria scores than the old ones. These results indicate that the new set of image quality criteria has a higher discriminative power than the old set and thus seems to be more suitable for evaluation of image quality in mammography.

Europe↗

In vivo absorbed dose measurements in mammography using a new real-time luminescence technique.

A dosimetry system based on radioluminescence (RL) and optically stimulated luminescence (OSL) from carbon doped aluminium oxide (Al2O3:C) crystals was developed for in vivo absorbed dose measurements in mammography. A small cylindrical crystal of Al2O3:C (diameter 0.48 mm and length 2 mm) was coupled to the end of a 1 mm diameter optical fibre cable. Owing to their small size and characteristic shape, these probes can be placed on the body surface in the field of view during the examination, without compromising the reading of the mammogram. Our new technique was tested with a mammography unit (Siemens Mammomat 3000) and screen-film technique over a range of clinically relevant X-ray energies. The results were compared with those obtained from an ionization chamber usually used for the determination of absorbed dose in mammography. The reproducibility of measurements was around 3% (1 standard deviation) at 4.5 mGy for both RL and OSL data. The dose response was found to be linear between 4.5 mGy and 30 mGy. The energy dependence of the system is around 18% between 23 kV and 35 kV. In vivo measurements were performed during three patient examinations. It was shown that entrance and exit doses could be measured. The presence of the small probes did not significantly interfere with the diagnostic quality of the images. Entrance doses estimated by RL/OSL results agreed within 3% with entrance surface dose values calculated from the ionization chamber measurements. These results indicate a considerable potential for use in routine control and in vivo dose measurements in mammography.

Aluminum Oxide↗

Commissioning of an NRC-type sealed water calorimeter at METAS using 60Co gamma-rays.

As part of a collaborative project between the National Research Council of Canada (NRC) and the Swiss Federal Office of Metrology and Accreditation (METAS), a sealed water calorimeter was built at NRC and transferred to METAS. The calorimeter is operated at 4 degrees C and uses two thermistor probes in a sealed glass vessel containing high-purity water to measure the radiation-induced temperature rise. The various correction factors have been evaluated and the estimated standard uncertainty on the absorbed dose to water is 0.41%. An extensive set of measurements using 60Co gamma-rays was carried out at NRC and two ionization chambers were calibrated against the absorbed dose determined calorimetrically. The chambers were also calibrated against the NRC standard for absorbed dose. After transferring the calorimeter to METAS, a similar set of measurements was carried out using their 60Co beam and the same two ionization chambers were calibrated against the absorbed dose to water established at METAS. The discrepancy between the three sets of calibration coefficients was smaller than the estimated standard uncertainty of 0.47% on the ratio of any pair of calibration coefficients.

Calibration↗

Increasing stroke incidence in Sweden between 1989 and 2000 among persons aged 30 to 65 years: evidence from the Swedish Hospital Discharge Register.

BACKGROUND AND PURPOSE: Stroke mortality is decreasing in Sweden, as is the case in other Western European countries. However, both decreases and increases have been reported in Sweden for persons younger than age 65 years. The aim of this study was to compare the incidence of stroke in Sweden between the periods 1989 and 1991 and 1998 and 2000 in persons aged 30 to 65 years. METHODS: All first-ever stroke patients aged 30 to 65 years in the Swedish Hospital Discharge Register between 1989 and 2000 were included. RESULTS: The age-standardized, 3-year average incidence increased by 19%, from 98.9 to 118.0 per 100 000 among men, and by 33%, from 48.4 to 64.4 among women, between 1989 and 1991 and 1998 and 2000. The largest increase was seen among those younger than 60 years. On a county level, the change in age-standardized stroke incidence varied from small decreases (-3%) to large increases (82%). CONCLUSIONS: Stroke incidence increased in Sweden for both men and women between 1989 and 2000. The increase was larger among women. This calls for action when it comes to studying risk factors and planning for prevention and health promotion and indicates the need for gender-specific studies.

Adult↗

Health promotion and rehabilitation: a case study.

BACKGROUND: Since the number of people in Sweden on long-term sick leave has rapidly increased since 1996, new non-biomedical models of occupational rehabilitation are at stake. A group of seven women who had finished medical treatment and rehabilitation but were still on sick leave or temporary disability pension for several years, worked in a problem-based rehabilitation group for 6 months. Focus for the group was on a process of change towards health and work ability. PURPOSE: The aim of this case study was to improve understanding of effects of a problem-based rehabilitation model (PBR) on health promoting processes amongst a group of women on long-term sick leave. METHOD: Data source was a focus group interview. The analysis follows the guidelines of qualitative analysis that emerges from grounded theory. RESULTS: The pedagogical model of PBR enhanced the participant's internal resources such as self-confidence and ability to act in a social setting. External resources such as social support were improved. An individual follow-up was conducted 2 years after the rehabilitation process and four out of seven women had returned to work. CONCLUSION: Among this group of women PBR launched health-promoting processes. When the more medically oriented treatment is finished or is not able to contribute further to the individual's recovery, other aspects of the individuals abilities and health resources will be focused upon.

Adult↗

Comparison of dosimetry recommendations for clinical proton beams.

The formalism and data in the two most recent dosimetry recommendations for clinical proton beams, ICRU Report 59 and the forthcoming IAEA Code of Practice, are compared. Chamber calibrations in terms of air kerma and absorbed dose to water are considered, including five different cylindrical ionization chamber types commonly used in proton beam dosimetry. The methodology for both types of calibration for ionization chambers is described in ICRU Report 59. The procedure based on air kerma calibrations is compared with an alternative formalism based on IAEA Codes of Practice (TRS-277, TRS-381), modified for proton beams. The new IAEA Code of Practice is exclusively based on calibrations in terms of absorbed dose to water and a direct comparison with ICRU Report 59 recommendations is made. Common to the two formalisms are the fundamental quantities Wair and w(air) and their atmospheric conditions of applicability. The difference in the recommended values of the ratio w(air)/Wair (protons to 60Co) is as large as 2.3%. The use of Wair and w(air) values for dry air (IAEA) and for ambient air (ICRU) is a contribution to the discrepancy, and the ICRU usage is questioned. For air kerma based chamber calibrations, ICRU Report 59 does not take into account the effect of different compositions of the build-up cap and chamber wall on the calibration beam quality. For the chamber types included in the study, this introduces discrepancies of up to 1.1%. Combined with differences in the recommended basic data, discrepancies in absorbed dose determination in proton beams of up to 2.1% are found. For the absorbed dose to water based formalism, differences in the formalism, notably the omission of perturbation factors for 60Co in ICRU 59, and data yield discrepancies in calculated kQ factors, and in absorbed dose determinations, between -1.5% and +2.6%, depending on the chamber type and the proton beam quality.

Air↗

Development of a compact proton scanning system in Uppsala with a moveable second magnet.

A scanned proton beam yields dose distributions that in most cases are superior to passively scattered proton beams and to other external radiation treatment modalities. The present paper gives a description of the scanning system that has been developed at the Svedberg Laboratory (TSL) in Uppsala. The scanning technique and the technical design are described. The solution with a small pole gap of the magnets and a moveable second magnet results in a very compact scanning head, which can therefore be incorporated in a gantry of relatively limited size. A prototype was constructed that has been used to realize various dose distributions with a scanned beam of 180 MeV protons at TSL.

Biophysical Phenomena↗

General characteristics of the use of silicon diode detectors for clinical dosimetry in proton beams.

The properties of silicon diode detectors, used for dosimetry in clinical proton beams, were investigated with special regard to the measurement of relative dose distributions in water. Different types of silicon diode detector were studied, and the resulting distributions of detector signal versus depth in the water phantom were compared with the corresponding distributions obtained with a plane-parallel NACP ionization chamber. The measurements were performed in a proton beam with an initial energy of 173 MeV. It is shown that the Hi-p silicon detector gives a signal which is proportional to the ionization density in the silicon crystal in all parts of the Bragg curve, and for all levels of accumulated dose to the detector. This is in contrast to detectors based on n-type silicon, or on low resistivity p-type silicon. After pre-irradiation, these latter detectors show a stopping-power dependent recombination, yielding an increase in the detector signal per unit dose with increasing LET. This effect leads to an over-response in the Bragg peak, which increases gradually with the accumulated detector dose. Using the Hi-p silicon diode detector, the depth ionization distribution was found to be equal to the distribution obtained with the plane-parallel NACP ionization chamber at all pre-irradiation levels, within the experimental accuracy. This implies that the quotient between the ionization in the detector and the absorbed dose to the surrounding water is equal for these detectors.

Calibration↗

Ferrous sulphate gel dosimetry and MRI for proton beam dose measurements.

Ferrous sulphate gel dosimetry has the potential for measurement of absorbed dose distributions in proton therapy. The chemical properties of the gel are altered according to the radiation dose and these changes can be evaluated in three dimensions using MRI. The purpose of this work was to investigate the properties of a ferrous gel used with clinical proton beams. The gel was irradiated with both monoenergetic and range-modulated proton beams. It was then evaluated using MRI. The depth dose by means of the 1/T1 distribution was studied and compared with data from a plane-parallel plate ionization chamber. 1/T1 was shown to be proportional to the dose at a mean proton energy of approximately 90 MeV. The dose response was no different from that obtained using photon beams. However, on normalization at the entrance, the relative 1/T1 at the Bragg peak was 15-20% lower than the corresponding ionization chamber data for the monoenergetic proton beam. Better agreement was found for the modulated beam, but with significant differences close to the distal edge of the 1/T1 distribution. The change in sensitivity with depth was explained by means of a linear energy transfer dependence. This property was further studied using Monte Carlo methods.

Calibration↗

Fast 2D phantom dosimetry for scanning proton beams.

A quality control system especially designed for dosimetry in scanning proton beams has been designed and tested. The system consists of a scintillating screen (Gd2O2S:Tb), mounted at the beam-exit side of a phantom, and observed by a low noise CCD camera with a long integration time. The purpose of the instrument is to make a fast and accurate two-dimensional image of the dose distribution at the screen position in the phantom. The linearity of the signal with the dose, the noise in the signal, the influence of the ionization density on the signal, and the influence of the field size on the signal have been investigated. The spatial resolution is 1.3 mm (1 s.d.), which is sufficiently smaller than typical penumbras in dose distributions. The measured yield depends linearly on the dose and agrees within 5% with the calculations. In the images a signal to noise ration (signal/1 s.d.) of 10(2) has been found, which is in the same order of magnitude as expected from the calculations. At locations in the dose distribution possessing a strong contribution of high ionization densities (i.e., in the Bragg peak), we found some quenching of the light output, which can be described well by existing models if the beam characteristics are known. For clinically used beam characteristics such as a Spread Out Bragg peak, there is at most 8% deviation from the NACP ionization chamber measurements. The conclusion is that this instrument is a useful tool for quick and reliable quality control of proton beams. The long integration-time capabilities of the system make it worthwhile to investigate its applicability in scanning proton beams and other dynamic treatment modalities.

Brachytherapy↗

Monte Carlo calculated stopping-power ratios, water/air, for clinical proton dosimetry (50-250 MeV).

Calculations of stopping power ratios, water to air, for the determination of absorbed dose to water in clinical proton beams using ionization chamber measurements have been undertaken using the Monte Carlo method. A computer code to simulate the transport of protons in water (PETRA) has been used to calculate sw.air-data under different degrees of complexity, ranging from values based on primary protons only to data including secondary electrons and high-energy secondary protons produced in nonelastic nuclear collisions. All numerical data are based on ICRU 49 proton stopping powers. Calculations using primary protons have been compared to the simple continuous slowing-down approximation (c.s.d.a.) analytical technique used in proton dosimetry protocols, not finding significant differences that justify elaborate Monte Carlo simulations except beyond the mean range of the protons (the far side of the Bragg peak). The influence of nuclear nonelastic processes, through the detailed generation and transport of secondary protons, on the calculated stopping-power ratios has been found to be negligible. The effect of alpha particles has also been analysed, finding differences smaller than 0.1% from the results excluding them. Discrepancies of up to 0.6% in the plateau region have been found, however, when the production and transport of secondary electrons are taken into account. The large influence of nonelastic nuclear interactions on proton depth-dose distributions shows that the removal of primary protons from the incident beam decreases the peak-to-plateau ratio by a large factor, up to 40% at 250 MeV. It is therefore emphasized that nonelastic nuclear reactions should be included in Monte Carlo simulations of proton beam depth-dose distributions.

Air↗

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration↗

Phantom study of chest radiography with storage phosphor, selenium, and film-screen systems.

PURPOSE: Chest radiographs from 3 digital systems--2 based on luminescent phosphors and one on selenium--and a conventional film-screen system were evaluated and compared. MATERIAL AND METHODS: Computed radiography (CR) has for the past years been dominated by a single manufacturer, but now several systems have been marketed. Using a chest phantom and, as test objects, 2 simulated tumours for the lung and mediastinum, respectively, and one object simulating pulmonary lines, a total of 400 exposures were made, 100 on each system. The test objects were placed randomly with a ratio of presence/absence of each object of about 50. Six radiologists participated, 2 residents and 4 staff members. A receiver operating characteristics (ROC) analysis was performed with construction of curves, and the difference between the curves was estimated with a 2-tailed paired t-test. RESULTS AND CONCLUSION: The selenium-based system performed significantly better for pulmonary line detection than all the other systems, and better than one storage phosphor system for the lung "tumour" (p < 0.05), while one storage phosphor system was slightly better than the other in diagnosing all 3 test objects. The score for the film-screen system was only average.

Humans↗