Evaluation of an automated deformable image matching method for quantifying lung motion in respiration-correlated CT images.

We have evaluated an automated registration procedure for predicting tumor and lung deformation based on CT images of the thorax obtained at different respiration phases. The method uses a viscous fluid model of tissue deformation to map voxels from one CT dataset to another. To validate the deformable matching algorithm we used a respiration-correlated CT protocol to acquire images at different phases of the respiratory cycle for six patients with nonsmall cell lung carcinoma. The position and shape of the deformable gross tumor volumes (GTV) at the end-inhale (EI) phase predicted by the algorithm was compared to those drawn by four observers. To minimize interobserver differences, all observers used the contours drawn by a single observer at end-exhale (EE) phase as a guideline to outline GTV contours at EI. The differences between model-predicted and observer-drawn GTV surfaces at EI, as well as differences between structures delineated by observers at EI (interobserver variations) were evaluated using a contour comparison algorithm written for this purpose, which determined the distance between the two surfaces along different directions. The mean and 90% confidence interval for model-predicted versus observer-drawn GTV surface differences over all patients and all directions were 2.6 and 5.1 mm, respectively, whereas the mean and 90% confidence interval for interobserver differences were 2.1 and 3.7 mm. We have also evaluated the algorithm's ability to predict normal tissue deformations by examining the three-dimensional (3-D) vector displacement of 41 landmarks placed by each observer at bronchial and vascular branch points in the lung between the EE and EI image sets (mean and 90% confidence interval displacements of 11.7 and 25.1 mm, respectively). The mean and 90% confidence interval discrepancy between model-predicted and observer-determined landmark displacements over all patients were 2.9 and 7.3 mm, whereas interobserver discrepancies were 2.8 and 6.0 mm. Paired t tests indicate no significant statistical differences between model predicted and observer drawn structures. We conclude that the accuracy of the algorithm to map lung anatomy in CT images at different respiratory phases is comparable to the variability in manual delineation. This method has therefore the potential for predicting and quantifying respiration-induced tumor motion in the lung.

Algorithms↗

Use of EPID for leaf position accuracy QA of dynamic multi-leaf collimator (DMLC) treatment.

We describe in this paper an alternative method for routine dynamic multi-leaf collimator (DMLC) quality assurance (QA) using an electronic portal imaging device (EPID). Currently, this QA is done at our institution by filming an intensity-modulated radiotherapy (IMRT) test field producing a pattern of five 1-mm bands 2 cm apart and performing a visual spot-check for leaf alignment, motion lags, sticking and any other mechanical problems. In this study, we used an amorphous silicon aS500 EPID and films contemporaneously for the DMLC QA to test the practicality and efficacy of EPID vis-à-vis film. The EPID image was transformed to an integrated dose map by first converting the reading to dose using a calibration curve, and then multiplying by the number of averaged frames. The EPID dose map was then back-projected to the central axis plane and was compared to the film measurements which were scanned and converted to dose using a film dosimetry system. We determined the full-width half-maximum (FWHM) of each band for both images, and evaluated the dose to the valley between two peaks. We also simulated mechanical problems by increasing the band gap to 1.5 mm for some leaf pairs. Our results show that EPID is as good as the film in resolving the band pattern of the IMRT test field. Although the resolution of the EPID is lower than that of the film (0.78 mm/pixel vs 0.36 mm/pixel for the film), it is high enough to faithfully reproduce the band pattern without significant distortion. The FWHM of the EPID is 2.84 mm, slightly higher than the 2.01 mm for the film. The lowest dose to the valley is significantly lower for the EPID (15.5% of the peak value) than for the film (28.6%), indicating that EPID is less energy independent. The simulated leaf problem can be spotted by visual inspection of both images; however, it is more difficult for the film without being scanned and contrast-enhanced. EPID images have the advantage of being already digital and their analysis can easily be automated to flag leaf pairs outside tolerance limits of set parameters such as FWHM, peak dose values, peak location, and distance between peaks. This automation is a new feature that will help preempt MLC motion interlocks and decrease machine downtime during actual IMRT treatment. We conclude that since EPID images can be acquired, analyzed and stored much more conveniently than film, EPID is a good alternative to film for routine DMLC QA.

Equipment Failure Analysis↗

A parameter optimization algorithm for intensity-modulated radiotherapy prostate treatment planning.

An iterative algorithm has been developed to analytically determine patient specific input parameters for intensity-modulated radiotherapy prostate treatment planning. The algorithm starts with a generic set of inverse planning parameters that include dose and volume constraints for the target and surrounding critical structures. The overlap region between the target volume and the rectum is used to determine the optimized target volume coverage goal. Sequential iterations are performed to vary the numerous parameters individually or in sets while other parameters remain fixed. A coarse grid search is first used to avoid convergence on a local maximum. Linear interpolation is then used to define a region for a fine grid search. Selected parameters are also tested for possible improvements in target coverage. In several representative test cases investigated the coverage of the planning target volume improved with the use of the algorithm while still meeting the clinical acceptability criteria for critical structures. The algorithm avoids time-consuming random trial and error variations that are often associated with difficult cases and also eliminates lengthy user learning curves. The methodology described in this paper can be applied to any treatment planning system that requires the user to select the input optimization parameters.

Algorithms↗