Spiral computed tomography and operative staging of gastric carcinoma: a comparison with histopathological staging.

BACKGROUND: Much controversy exists as to the value of computed tomography (CT) in the preoperative staging of gastric cancer, because of its limited ability to identify correctly lymph node (LN) metastases, invasion of adjacent organs, or hepatic and peritoneal metastases. Spiral CT scanners have a number of potential advantages over conventional scanners, including the absence of respiratory misregistration, image reconstruction smaller than scan collimation permitting overlapping slices and optimisation of intravenous contrast enhancement. AIM: To compare the performance of spiral CT and operative assessment against formal (TNM) pathological staging. PATIENTS AND METHODS: A study of 105 consecutive patients who underwent both spiral CT and operative staging was performed. All CT scans were reviewed by a radiologist who commented on tumour location and size, evidence of adjacent organ invasion, lymph node metastases to both N1 and N2 nodes, and evidence of hepatic and peritoneal metastases. All patients underwent careful operative assessment at the time of surgery, along the lines suggested by Rohde and colleagues. RESULTS: Spiral CT remained poor at identifying LN metastases to both N1 and N2 lymph nodes, with sensitivity ranging from 24 to 43%; specificity, however, was 100%. Operative staging was superior, with sensitivities between 84 and 94%, but specificity was much lower (63-74%). Spiral CT correctly detected 13 of 17 cases of invasion of either the colon or the mesocolon (sensitivity 76%) compared with 16 of 17 cases at operative staging (sensitivity 94%). Spiral CT correctly identified three of six cases with invasion of the pancreas (sensitivity 50%) compared with six of six cases on operative staging (sensitivity 100%). Spiral CT correctly identified 12 of 17 cases of peritoneal metastases (sensitivity 71%) and four of seven cases of hepatic metastases (sensitivity 57%). CONCLUSION: Whilst spiral CT remains poor at identifying lymph node metastases, it correctly identified most cases with invasion of either the colon or the mesocolon and half the cases of pancreatic invasion. It was of value in detecting peritoneal metastases and some cases with hepatic metastases. At present, at Leeds General Infirmary spiral CT is performed routinely on all patients with gastric cancer and a selective staging laparoscopy policy is adopted in those patients in whom the status of the peritoneal cavity and liver is in doubt.

Adult↗

Endoleak as a complication of endoluminal grafting of abdominal aortic aneurysms: classification, incidence, diagnosis, and management.

The inability to obtain or maintain a secure seal between a vessel wall and a transluminally implanted intra-aneurysmal graft is a complication unique to the evolving technique of endovascular aneurysm exclusion. Because the term "leak" has long been associated with aneurysm rupture, the term "endoleak" is proposed as a more definitive description of this phenomenon. Embracing both persistent blood flow into the aneurysmal sac from within or around the graft (graft related) and from patent collateral arteries (nongraft related), endoleak can be classified as primary or secondary depending on the time of occurrence (within 30 days of implantation or following apparent initial seal, respectively). Diagnostic techniques to detect endoleak include arteriography, intraprocedural pressure monitoring, contrast-enhanced computed tomography, abdominal X ray, and duplex scanning. Management strategies for endoleak range from observation with periodic imaging surveillance to correction by additional endoluminal or surgical procedures. Standardization of the terminology describing this important sequela to endovascular aneurysm exclusion should facilitate uniform reporting of clinical trial data vital to the evaluation of this emerging technique.

Aortic Aneurysm, Abdominal↗

Three-year experience with the White-Yu Endovascular GAD Graft for transluminal repair of aortic and iliac aneurysms.

PURPOSE: To report a > 3-year experience with a modular, balloon-expandable endovascular graft used for aneurysm exclusion in the aorta and other arteries. METHODS: The customized White-Yu Endovascular GAD Graft, a woven polyester prosthesis with an intrinsic Elgiloy wire graft attachment system along the body of the graft, is a flexible endograft design available in straight, tapered, and bifurcated versions that can be delivered transluminally through 18F to 24F sheaths. RESULTS: Since July 1993, 93 patients have received the White-Yu endograft for treatment of 76 abdominal aortic, 3 thoracic aortic, 13 iliac, and 1 popliteal aneurysms. Of the 79 aortic procedures, 39 involved straight tube grafts, 20 were tapered aortoiliac models, and 20 were bifurcated devices. Success rates for tube grafts were 81% in the abdominal aorta and 100% for the thoracic aorta; 5 primary endoleaks (14%) and 2 conversions to surgery (5.6%) occurred with this graft type. Aortoiliac grafts were deployed successfully in 95% (19/20) of cases with 1 conversion (5%) due to thrombosis. Seventy-five percent of the bifurcated endograft procedures were successful, with 4 conversions (20%) for technical failures and 1 graft thrombosis. Four additional endografts were deployed to treat two primary and two secondary endoleaks in tube graft patients. Two access-related arterial injuries were treated surgically. There was one case of embolus to the distal femoral artery but no microembolization. Overall perioperative (30-day) mortality was 3.1%. Over a mean 18-month follow-up (range 2 to 39), no late graft thrombosis, stenosis, or graft migration has been seen on CT scans or X ray. Endoleak has not been detected in any aortoiliac or bifurcated graft. Aneurysm size has diminished consistently in successfully treated cases. CONCLUSIONS: The White-Yu endograft appears to offer a safe, efficacious, and minimally invasive means of excluding aneurysms from the circulation. Improvements in patient selection, surgical techniques, and equipment have reduced the incidence of endoleak and conversion to open repair over the course of the evaluation.

Aortic Dissection↗

Endoluminal repair of abdominal aortic aneurysms: strengths and weaknesses of various prostheses observed in a 4.5-year experience.

PURPOSE: To summarize the results of endovascular abdominal aortic aneurysm (AAA) treatment using several endograft designs over a 4.5-year experience and offer comparisons on the various devices. METHODS: From May 1992 to August 1996, 121 AAA patients meeting the criteria for an endoluminal repair were treated with 1 of 5 endograft designs in three configurations. The endografts were implanted in the operating room under fluoroscopic control. Follow-up included contrast-enhanced computed tomography within 10 days of operation, 6 months postoperatively, and annually thereafter. RESULTS: Endografts were successfully deployed in 106 patients (88%). Fifteen cases were converted to open repair. Six procedure-related deaths occurred within 30 days owing to myocardial infarction (3), combined renal failure and septicemia (2), and multisystem failure (1). There were 36 local/vascular complications (30%) and 18 systemic/remote complications (15%). Of the 121 patients undergoing endoluminal AAA repair, 93 (77%) are currently alive and well with their AAAs excluded from the circulation. CONCLUSIONS: Trends in endoluminal AAA repair and prosthetic design point toward simpler devices and earlier treatment of smaller aneurysms once the long-term outcome of aortic endografting has been determined.

Aortic Aneurysm, Abdominal↗

[Real-time ultrasonographic pregnancy diagnosis (B-mode) in sheep. 3. Determination of the number of embryos and fetuses].

Transrectal ultrasound examination was performed once in 1159 German Mutton Merino ewes in a standing position using a 5.0 MHz linear array transducer (group 1), 505 German Mutton Merino ewes were restrained in dorsal recumbency while scanned transrectally using a 7.5 MHz probe (group 2). Referring to actual number of lambs born the prepartal prediction of fetal number was correct in 71.8% (group 1) and 78.6% (group 2) of the ewes from days 17 to 69 p.c. The highest accuracy for determining fetal number (89.1%) was in group 1 at days 35 to 46 of gestation. In group 2 the accuracy was more consistent over the whole period of examinations and reached over 80% from as early as 29 days p.c. As litter size increased, examinations in both groups became increasingly inaccurate in determining correct litter size. A subdivision of living, underdeveloped and dead embryos or foetuses was possible by the presence or the absence of a heartbeat and the crown-rump-length of the embryos or foetuses. The percentage of ewes with embryonic or fetal loss is given.

Animals↗

Repair of abdominal aortic aneurysms by the endoluminal method: outcome in the first 100 patients.

OBJECTIVE: To report the outcome in our first 100 patients with abdominal aortic aneurysms repaired by the endoluminal method. DESIGN: Analysis of concurrently collected data of patients undergoing repair of an aortic aneurysm. The technique involves the delivery of an endograft into the abdominal aorta by means of a sheath inserted through the femoral or iliac artery. Clinical examination and contrast-enhanced computed tomography (CT) were performed within 10 days, at six months and then annually after operation. SETTING: Royal Prince Alfred Hospital, Sydney, a tertiary referral teaching hospital. PATIENTS: 100 patients, seven women and 93 men, with a mean age of 70 years (range, 46-87), treated between May 1992 and December 1995. Because of comorbidities, 43 of the patients had been considered unsuitable for conventional open repair at other medical centres. Our criteria for inclusion were the presence of a 1.5-cm or greater segment of thrombus-free aorta between the lowermost renal artery and the commencement of the aneurysm, and iliac arteries allowing access to the aorta from the groin. OUTCOME MEASURES: (i) Need to convert to open repair; (ii) damage to the arteries from sheath insertion; (iii) communication between the aneurysmal sac and the circulation; (iv) death within 30 days; (v) effect on aneurysmal diameter. RESULTS: Endografts were successfully deployed in 88 patients. In the remaining 12 patients endoluminal repair was converted to open repair. There were five deaths within 30 days of the operation, including three in the failed group. Damage to the femoral or iliac arteries from sheath insertion occurred in five patients. These were repaired without the need to convert to open repair. No patients were lost to follow-up (62 patients have been followed up for at least six months). Contrast-enhanced computed tomography shows progressive diminution in maximal transverse diameter of the aneurysms with time, after successful exclusion of the aneurysmal sac from the general circulation. CONCLUSION: Endoluminal repair of abdominal aortic aneurysms is feasible and this method of repair is durable in mid-term follow-up.

Aged↗

CD45-null transgenic mice reveal a positive regulatory role for CD45 in early thymocyte development, in the selection of CD4+CD8+ thymocytes, and B cell maturation.

The CD45 transmembrane glycoprotein has been shown to be a protein phosphotyrosine phosphatase and to be important in signal transduction in T and B lymphocytes. We have employed gene targeting to create a strain of transgenic mice that completely lacks expression of all isoforms of CD45. The spleens from CD45-null mice contain approximately twice the number of B cells and one fifth the number of T cells found in normal controls. The increase in B cell numbers is due to the specific expansion of two B cell subpopulations that express high levels of immunoglobulin (IgM) staining. T cell development is significantly inhibited in CD45-null animals at two distinct stages. The efficiency of the development of CD4-CD8- thymocytes into CD4+ CD8+ thymocytes is reduced by twofold, subsequently the frequency of successful maturation of the double positive population into mature, single positive thymocytes is reduced by a further four- to fivefold. In addition, we demonstrate that CD45-null thymocytes are severely impaired in their apoptotic response to cross-linking signals via T cell receptor (TCR) in fetal thymic organ culture. In contrast, apoptosis can be induced normally in CD45-null thymocytes by non-TCR-mediated signals. Since both positive and negative selection require signals through the TCR complex, these findings suggest that CD45 is an important regulator of signal transduction via the TCR complex at multiple stages of T cell development. CD45 is absolutely required for the transmission of mitogenic signals via IgM and IgD. By contrast, CD45-null B cells proliferate as well as wild-type cells to CD40-mediated signals. The proliferation of B cells in response to CD38 cross-linking is significantly reduced but not abolished by the CD45-null mutation. We conclude that CD45 is not required at any stage during the generation of mature peripheral B cells, however its loss reveals a previously unrecognized role for CD45 in the regulation of certain subpopulations of B cells.

ADP-ribosyl Cyclase↗

Prospective study of the aetiology of infusion phlebitis and line failure during peripheral parenteral nutrition.

Four techniques of administering peripheral parenteral nutrition (PPN) were examined prospectively to investigate the role of mechanical trauma in the development of infusion phlebitis. Patients in group 1 (n = 15) were fed via a standard 18-G Teflon cannula which was removed on completion of the infusion and was rotated to the contralateral arm every day. Group 2 patients (n = 15) had a similar catheter sited in each forearm simultaneously, with rotation of the side of infusion each day. Patients in group 3 (n = 17) had a 15-cm Silastic rubber catheter inserted into a forearm vein and a standard cannula sited in the contralateral forearm, with alternation of infusion each day. Those in group 4 (n = 13) had a fine-bore 23-G silicone catheter sited in one arm only. Patients in groups 1, 2 and 3 were fed over 12-h cycles and those in group 4 for a 24-h continuous cycle. A total of 408 patient-days of PPN were given. Mean duration of PPN in groups 1-4 was 7.5, 9, 5.5 and 5 days respectively. Infusion phlebitis was not recorded in patients who had a daily change of cannula (group 1), but occurred in four patients in group 2, eight in group 3 and eight in group 4. Phlebitis scores were 0, 9, 15 and 12 for groups 1-4 respectively. Severe phlebitis and line occlusion occurred more frequently in patients with a 15-cm catheter (group 3) and in those fed continuously over 24 h (group 4). These results suggest that mechanical trauma is an important factor in the aetiology of infusion phlebitis. This can be minimized by reducing the time for which the vein wall is exposed to nutrient infusion and by reducing the amount of prosthetic material within the vein.

Adult↗

Results of endoluminal grafting of abdominal aortic aneurysms are dependent on aneurysm morphology.

The aim of this prospective study was to analyze the outcome of elective endoluminal grafting in patients with various morphologies of abdominal aortic aneurysms (AAA). Between May 1992 and May 1994, endoluminal repair of AAA was undertaken in 40 patients. After detailed imaging by means of CT scanning and arteriography, aneurysms were classified into one of two types according to the following criteria: type I (suitable for transfemoral implantation of a straight tube graft), AAA with a proximal neck (2 cm or longer), a distal neck (1.5 cm or longer), and an iliac artery diameter of 8 mm or greater (N = 19); or type II (requiring tapered aortoiliac or bifurcated grafts or access through an iliac approach), AAA that did not fit the type I criteria (N = 21). Radiographic guidance was used to pass the aortic endografts (38 Dacron and 2 PTFE) via a delivery sheath introduced through the femoral or iliac arteries into the aorta. The configuration of the aortic endografts was tubular in 26 patients, tapered aortoiliac in 11, and bifurcated in three. Successful endoluminal repair was achieved in 17 (89%) of 19 patients with type I AAA and in 15 (71%) of 21 patients with type II AAA. All failed endoluminal repairs proceeded to successful open repair, and there were no deaths during the period of hospitalization for the operation. The mean operative time and mean hospital stay were shorter in patients with type I AAA compared to patients with type II AAA. The incidence of postoperative complications was 37% in type I endoluminal repairs compared to 71% in type II endoluminal repairs. There was one cardiac death (procedure related) within 30 days, and there were three late deaths (one cardiac, one from liver failure in a type II AAA repair, and one from a ruptured esophagus in a type I repair). These preliminary results suggest that there is a better outcome in transfemoral endoluminal tube graft repair of aneurysms conforming to type I criteria compared to endoluminal repair of the more complex type II AAA.

Aged↗

Immunogenicity of full length and truncated forms of the human immunodeficiency virus type I envelope glycoprotein.

We have monitored the immunogenicity of a V1V2 sub-fragment of gp 120 in contrast to the full length protein and to a truncated form (PR12) where the V1, V2 and V3 regions were removed. In contrast to previously published work [1] these studies show that monomeric forms of envelope are capable of inducing antibodies specific for both linear and discontinuous epitopes. These antibodies are capable of neutralising HIV infectivity. The majority of neutralising antibodies were specific for epitopes within the V2 and V3 regions demonstrating the immunodominance of these regions in monomeric gp 120. Relatively few of the antibodies were specific for the CD4 binding site, suggesting that this region is poorly immunogenic. Immunisation of rats with the PR12 truncated protein did not significantly enhance the immunogenicity of the CD4 binding site. However, the immune response generated included antibodies capable of binding to diverse primary HIV-1 and HIV-2 envelope glycoproteins. We have shown that up to 30% of sera from HIV-1 infected individuals have antibodies that are capable of recognising conformation-dependent epitopes within the V1V2 region of the clone HXB10, suggesting the presence of conserved cross-reactive epitopes. Furthermore we have shown an association between the presence of V1V2 reactive antibodies and the neutralisation titre of the sera tested suggesting that antibodies to this region contribute to the cross-reactive neutralising response.

AIDS Vaccines↗

Historic control comparison of outcome for matched groups of patients undergoing endoluminal versus open repair of abdominal aortic aneurysms.

PURPOSE: Currently no randomized studies show the relative morbidity and mortality of the open and endoluminal methods of abdominal aortic aneurysm (AAA) repair. The aim of this study was to analyze the outcome of two matched groups of patients with AAA, one undergoing open repair and the other undergoing endoluminal repair. METHODS: Two groups of patients who had undergone repair of AAA by open technique (group 1) or by endoluminal methods (group 2) were compared. A historic control cohort of 27 patients was selected from 56 consecutive patients who underwent open repair of AAA between January 1991 and February 1992. Patients considered unsuitable for the endoluminal method on the basis of computed tomography and aortography were excluded (n=29). Between May 1992 and November 1994 prospective data were recorded for 62 consecutive patients who underwent endoluminal repair by tube or bifurcated endografts. Twenty-eight patients who had been specifically referred for endoluminal AAA repairs because of preexisting severe medical comorbidities were excluded. Six of the endoluminal cases had failure, requiring conversion to open operation, and were excluded for separate analysis, leaving 28 patients in group 2. Patients in both groups were thus fit and suitable for either open or endoluminal repair and were comparable in relation to age, sex, risk factors, dimensions, and form of AAA. RESULTS: The mean values for operation time, blood loss, intensive care stay, and hospital stay for group 1 and group 2 were 2.6 versus 3.1 hours, 1422 versus 873 ml,* 1.8 versus 0.7 days,* and 12.4 versus 11.1 days, respectively (*p<0.05). Local/vascular complications occurred in 15% of patients in group 1 compared with 25% in group 2 (p=0.55), whereas remote/systemic complications occurred in 37% and 29%, respectively (p=0.3). Five of 28 patients in the endoluminal group had complications requiring early operative repair (n=3) or late revision (n=2). When comparison was made on an intention-to-treat basis (with failed procedures included), the incidence of local/vascular complications was significantly greater for endoluminal repair (p=0.047). CONCLUSIONS: The incidence of systemic/remote complications was similar for the two groups in spite of significantly less blood loss and shorter intensive care unit stay with endoluminal repair. The incidence of local/vascular complications had a tendency to be higher for endoluminal compared with standard open method (and was significantly greater if failed procedures were included). In this early experience with prototype devices, patients who were medically suitable for open surgical procedures did not derive benefit from the less invasive endoluminal technique with respect to duration of operation, length of hospital stay, or perioperative morbidity and mortality. On the other hand, because they also did not have worse outcome, a randomized study is now justified in this group.

Age Factors↗

Early experience with transfemoral endovascular aneurysm management (TEAM) in the treatment of aortic aneurysms.

OBJECTIVES: To evaluate the early experience with transfemoral endovascular aortic aneurysm management using the Endovascular Grafting System. DESIGN: Multi-centre prospective evaluation of the implantation procedure and early results (median follow-up 153 days). SETTING: Department of Surgery, University Hospital Utrecht, The Netherlands; Department of Surgery, University of Sydney, Australia; University of Leicester School of Medicine, Leicester, U.K., Department of Surgery, Karolinska Hospital, Stockholm, Sweden and Nuffield Department of Surgery, University of Oxford, John Radcliffe Hospital; Oxford, U.K. MATERIALS: 31 consecutive patients treated in 13 months. CHIEF OUTCOME MEASUREMENTS: Peri and postoperative morbidity and mortality in accordance with the recommendations of the Ad Hoc Committee on Reporting Standards. MAIN RESULTS: Graft placement was initially successful in all 31 patients. In one patient the endograft had to be replaced by a standard aortic tube graft because of extra graft flow in the aneurysm sac, and complaints of back pain. One patient died from multiple organ failure, 11 days after the operation. In three patients five severe adverse events were recorded. Breaks of the attachment system were encountered in two patients. These failures did not have severe clinical consequences for individual patients. CONCLUSIONS: Transfemoral Endovascular Aneurysm Management is a technically demanding procedure that requires special training in both catheter and surgical techniques. The potential for less operative morbidity when compared to conventional surgery and the prospect of technical improvements in graft and introduction system design will make TEAM an important tool in aneurysm management in the near future.

Aged↗

No additional benefit from laser in balloon angioplasty of the superficial femoral artery.

OBJECTIVES: To evaluate the efficacy of the addition of plaque ablation by hot-tip laser to balloon angioplasty. DESIGN: Prospective randomised clinical trial. MATERIALS AND METHODS: Patients with either occlusion orf > 50% diameter stenosis less than 3 cm in length in the superficial femoral artery, and with two or three calf vessel run-off were eligible and randomised to receive either balloon angioplasty alone or with laser assistance. Treatment failure in follow-up was defined as reocclusion or recurrence of greater that 50% stenosis at the site of angioplasty. RESULTS: Ninety limbs (82 patients) were entered into the study. Forty-four patients had mild claudication, 32 more severe symptoms and 6 rest pain or ulceration. More patients with diabetes (5 of 5, p = 0.04, Fisher's exact test) and occlusions (16 of 22, p < 0.05, chi(2)) were randomised to the laser group. Initial technical success was obtained in all lesions. The median duration of follow-up was 1 year. Failure occurred in 40 limbs during follow-up. Three segments, all with initial occlusions and undergoing laser angioplasty re-occluded within 2 days, one requiring immediate thrombectomy. Another 20 limbs underwent further intervention. Overall success (+/- S.D.) (Kaplan-Meier) at 1 year was 67% (+/- 5%) and at 2 years 43% (+/- 7%). Only increased age, initial occlusion, female sex, and not smoking were significantly (p < 0.05, Cox's proportional hazards) associated with failure; on multivariate analysis, age and occlusion were the best independent predictors. There was no significant difference (p > 0.05) in outcome between limbs undergoing laser assisted balloon angioplasty and balloon alone either overall of within the stenosis or occlusion subgroups. CONCLUSIONS: This study found no significant benefit was gained by the addition of laser to balloon angioplasty and that the long term success was modest for lesions considered to be suitable for angioplasty.

Aged↗

A prospective study of anatomico-pathological changes in abdominal aortic aneurysms following endoluminal repair: is the aneurysmal process reversed?

AIM: The aim of this prospective study was to analyse early anatomico-pathological changes in abdominal aortic aneurysms (AAA) following endoluminal repair to determine if the natural history of continued expansion of AAA is reversed. MATERIALS AND METHODS: Sixty-seven of 85 patients undergoing endoluminal AAA repair between May 1992 and August 1995 had their operations prior to the end of February 1995 and were potentially available for follow up at 6 months or longer after operation. Excluded were: patients with failed endoluminal repairs (n = 14), patients who died within 6 months of operation (n = 5), patients with anastomotic AAA (n = 1), leaving 47 patients in the study group. Based on contrast enhanced CT performed preoperatively, within 10 days of operation and 6, 12 and 18 months after operation patients were divided into two groups: those in whom the AAA maximum transverse diameter (MTD) decreased Group I (n = 39) and those in which it increased Group II (n = 8). The following parameters were analysed: diameter of the supra coeliac aorta, MTD and the dimensions of the proximal and distal necks of the AAA plus extravasation ("leak") of contrast into the aneurysmal sac. RESULTS: Leak of contrast was seen in 0 of 39 patients in Gp I and 5 of 8 patients in Gp II. Patients in Group I experienced a progressive diminution in AAA mean MTD. The diameters of the proximal and distal necks increased but there was no shortening of the length of the necks in this group. In Group II the AAA MTD was dependent on whether or not the aneurysmal sac was isolated from the circulation. The diameter of the proximal and distal necks increased irrespective of this fact. CONCLUSION: We conclude that in early follow up AAA which diminish in diameter following endoluminal repair remain isolated from the general circulation. Co-incident with this decrease in AAA diameter, the proximal and distal necks increase in diameter but do not undergo any shortening in length. This paradoxical increase in neck diameter, was not progressive in the period of follow-up.

Aged↗

Hickman catheters: left-sided insertion, male gender, and obesity are associated with an increased risk of complications.

BACKGROUND: Semipermanent tunnelled silicone rubber Hickman catheters are widely used to provide durable central venous access for patients with cancer or haematological disease. AIMS: To document the frequency and severity of Hickman catheter related adverse events and to identify predisposing factors. METHODS: A retrospective review was undertaken of 153 sequential Hickman catheters inserted into patients receiving treatment for cancer or haematological disease. All Hickman catheters were inserted percutaneously in a radiology department under local anaesthesia and fluoroscopic control. The exact position of the catheter tip was determined by reviewing post-insertion radiographs. RESULTS: The median duration of catheter use was 55 days (range one-650). Complications led to the removal of 32% of catheters. Exit site infection complicated 22% of catheters, septicaemia 7%, migration or dislodgment 7%, and venous thrombosis 8%. Complications were more common in male patients (exit site infection and catheter loss), in patients with acute leukaemia (septicaemia) and in obese patients (catheter migration). Left sided catheters caused more venous thrombosis and were more likely to malfunction or block. Left sided catheters required removal more frequently than right sided catheters. Termination of the Hickman catheter within the high superior vena cava (SVC) resulted in loss of function earlier when compared to termination with the low SVC or right atrium (RA). CONCLUSIONS: Right-sided Hickman catheters terminating in the low SVC/RA offer the best chance of durable function. The use of subcutaneously tunnelled catheters in obese patients poses unique problems with catheter migration. Vigilance in the placement and care of Hickman catheters remains essential.

Catheterization, Central Venous↗